Chemically modified flexible strips as electrochemical biosensors

Abstract

A flexible and disposable strip sensor for non-enzymatic glucose detection is demonstrated in this work. The strips are prepared by using chemical modification processes followed by a simple electroless deposition of copper. Essentially, polyester overhead projector (OHP) transparent films are modified with a monolayer of 3-aminopropyltrimethoxysilane (APTMS) and polyaniline (PANI) conducting polymer. Later, nanostructured copper is deposited onto this modified film. Scanning electron microscope (SEM) and X-ray diffraction (XRD) studies are used for the structural, morphological and crystallinity characterization of the modified films. Electrochemical techniques, namely cyclic voltammetry (CV) and chronoamperometry (CA), are employed for the non-enzymatic detection of glucose. These studies clearly reveal the formation of homogeneous, close-packed spherical Cu particles converged into uniform film that exhibits a good catalytic activity towards the oxidation of glucose. The Cu/PANI/APTMS/OHP sensor displays a remarkable enhancement in the oxidation current density, a very high sensitivity value of 2.8456 mA cm−2 per mM, and a linear concentration range from 100 μM to 6.5 mM associated with glucose detection. Detection limit is estimated to be 5 μM and the response time of the sensor is determined to be less than 5 s. For comparison, similar studies are performed without PANI, namely Cu/APTMS/OHP films for glucose detection. In this case, a sensitivity value of 2.4457 mA cm−2 per mM and a linear concentration range of 100 μM–3 mM are estimated. The higher performance characteristics observed in the case of Cu/PANI/APTMS/OHP are attributed to the synergistic effects of the conducting polymer acting as an electron facilitator and the nanostructured Cu films. These disposable, flexible and low-cost strip sensors have also been applied to the detection of glucose in clinical blood serum samples and the results obtained agree very well with the actual glucose level.

Graphical abstract: Chemically modified flexible strips as electrochemical biosensors

Supplementary files

Article information

Article type
Paper
Submitted
10 Apr 2014
Accepted
11 Jun 2014
First published
11 Jun 2014

Analyst, 2014,139, 4661-4672

Chemically modified flexible strips as electrochemical biosensors

R. Thota and V. Ganesh, Analyst, 2014, 139, 4661 DOI: 10.1039/C4AN00646A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements