Jump to main content
Jump to site search
PLANNED MAINTENANCE Close the message box

Scheduled maintenance work on Wednesday 22nd May 2019 from 11:00 AM to 1:00 PM (GMT).

During this time our website performance may be temporarily affected. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 10, 2014
Previous Article Next Article

The applicability of proton transfer reaction-mass spectrometry (PTR-MS) for determination of isocyanic acid (ICA) in work room atmospheres

Author affiliations

Abstract

A method is presented for the real-time quantitative determination of isocyanic acid (ICA) in air using proton transfer reaction-mass spectrometry (PTR-MS). Quantum mechanical calculations were performed to establish the ion-polar molecule reaction rate of ICA and other isocyanates. The PTR-MS was calibrated against different ICA air concentrations and humidity conditions using Fourier transform-infrared spectroscopy (FT-IR) as quantitative reference. Based on these experiments a simple humidity dependant model was derived for correction of the PTR-MS response for ICA. The corrected PTR-MS data was linearly correlated (R2 > 0.99) with the data acquired by FT-IR. The PTR-MS instrumental limit of detection (LOD) for ICA was 2.3 ppb. Humid atmospheres resulted in LODs of 3.4 and 7.8 ppb, at an absolute humidity (AH) of 4.0 and 15.5 g m−3, respectively. Furthermore, off-line sampling using denuder and impinger samplers using di-n-butylamine (DBA) as derivatization reagent was compared with PTR-MS measurements in a dynamically generated standard ICA atmosphere. Denuder (n = 4) and impinger (n = 4) sampling subsequent to liquid chromatography mass spectrometry (LC-MS) determination compared to corrected PTR-MS data resulted in recoveries of 79.6 (8.1% RSD) and 99.9 (9.3% RSD) %, respectively. Measurements of ICA from thermally decomposed cured 1,6-hexamethylene diisocyanate (HDI)-paint was performed using PTR-MS and denuder (n = 3) sampling. The relation between the average ICA responses using denuders (34.4 ppb) and PTR-MS (42.6 ppb) was 80.6%, which coincided well with the relative recovery obtained from the controlled laboratory experiments using dynamically generated ICA atmospheres (79.6%). The variability in ICA air concentration during the welding process (170% RSDPTR-MS) illustrated the need for real-time measurements.

Graphical abstract: The applicability of proton transfer reaction-mass spectrometry (PTR-MS) for determination of isocyanic acid (ICA) in work room atmospheres

Back to tab navigation

Publication details

The article was received on 30 Jun 2014, accepted on 18 Aug 2014 and first published on 19 Aug 2014


Article type: Paper
DOI: 10.1039/C4EM00363B
Environ. Sci.: Processes Impacts, 2014,16, 2423-2431

  •   Request permissions

    The applicability of proton transfer reaction-mass spectrometry (PTR-MS) for determination of isocyanic acid (ICA) in work room atmospheres

    M. J. Jankowski, R. Olsen, C. J. Nielsen, Y. Thomassen and P. Molander, Environ. Sci.: Processes Impacts, 2014, 16, 2423