Issue 2, 2013

Single shot laser flash photolysis with a fibre-coupled reference beam monitor

Abstract

In the standard nanosecond laser photolysis method for kinetic studies, a Q-switched laser generates transient species, and absorption spectrophotometry provides a measure of their concentrations. The sample is placed between the monitoring source (a pulsed xenon arc or a flash lamp) and a monochromator, and a photomultiplier tube (PMT) is used for measuring the intensity of the light leaving the exit slit of the monochromator. With this (single-beam) arrangement, the laser-induced change in the absorbance of the sample, ΔA, can be calculated only if the intensity of the monitoring beam remains constant during the time interval of interest. When this condition is not fulfilled, a second measurement of the PMT output is made after blocking the path of the laser beam, but shot-to-shot variations in the output of the monitoring source vitiate the analysis when ΔA is small. To overcome this problem, double-beam versions were developed in the last century, but the single-beam version still enjoys greater popularity. With a view to making the double-beam method easily implementable, some simple modifications are introduced, which permit the conversion of an existing laser kinetic spectrometer into a double-beam variant (with one or two monochromators).

Graphical abstract: Single shot laser flash photolysis with a fibre-coupled reference beam monitor

Supplementary files

Article information

Article type
Technical Note
Submitted
01 Jun 2012
Accepted
14 Aug 2012
First published
21 Aug 2012

Photochem. Photobiol. Sci., 2013,12, 404-406

Single shot laser flash photolysis with a fibre-coupled reference beam monitor

H. Li, L. van 't Hag, Y. A. Yousef, T. B. Melø and K. Razi Naqvi, Photochem. Photobiol. Sci., 2013, 12, 404 DOI: 10.1039/C2PP25170A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements