Issue 21, 2013

A fast on-line micro-column sample pretreatment with a HPLC column switching technique and large volume sample injection for determination of non-steroidal anti-inflammatory drugs in human serum

Abstract

A fully automated HPLC column-switching method with fast sample pretreatment on a short micro-column was developed for sensitive and quantitative determination of non-steroidal anti-inflammatory drugs (ketoprofen, ibuprofen, sodium diclofenac and flurbiprofen) in human serum with UV detection. The serum samples were diluted 3 : 1, with 2% acetic acid in acetonitrile, and centrifuged at 4200g for 10 min. 200 μL of supernatant was injected directly into the HPLC system. An on-line sample clean-up was achieved on a pretreatment micro-column LiChrospher® RP-18 ADS 25 mm × 2.0 mm, 25 μm (Merck) with a washing mobile phase (acetonitrile : 0.085% phosphoric acid; 10 : 90) at a flow rate of 2.5 mL min−1. The valve switch to an analytical column was set at the 7th min in a back-flush mode. Separation of all antiflogistics and internal standard butylparaben was performed using a Chromolith Performance RP 18e 100 × 4.6 mm column (Merck) and a mobile phase consisting of 0.085% phosphoric acid and acetonitrile in gradient mode. The column temperature was set at 45 °C and a flow rate of 1.0 mL min−1 and a UV detector at 210 nm. Standard and matrix calibrations were carried out under the optimal chromatographic conditions in the linearity range 7–2000 ng mL−1 with good linearity – correlation coefficients for all compounds are in the range 0.9956–0.9999, n ≥ 6. Limits of quantification were in the range 7–56 ng mL−1. The accuracy of the method defined as a mean recovery was in the range 81.97–118.40%. Intra-day method precision was measured at three concentration levels and relative standard deviations were in the range 0.07–1.92%. The developed method showed high sample throughput, fully automated sample clean-up and analysis in time less than 17 min.

Graphical abstract: A fast on-line micro-column sample pretreatment with a HPLC column switching technique and large volume sample injection for determination of non-steroidal anti-inflammatory drugs in human serum

Article information

Article type
Paper
Submitted
26 Mar 2013
Accepted
02 Sep 2013
First published
03 Sep 2013

Anal. Methods, 2013,5, 6153-6159

A fast on-line micro-column sample pretreatment with a HPLC column switching technique and large volume sample injection for determination of non-steroidal anti-inflammatory drugs in human serum

I. Brabcová, D. Šatínský and P. Solich, Anal. Methods, 2013, 5, 6153 DOI: 10.1039/C3AY40505B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements