Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes

Abstract

Relative elemental sensitivities are reported for a number of sample and skimmer cone combinations, with standard and enhanced pumping of the interface region, for the Thermo Scientific Neptune MC-ICP-MS. An approximate two-fold sensitivity enhancement was observed for Sr, Nd, Hf, Pb and U using the Jet sample cone and an enhanced pumping configuration, compared to the standard arrangement. In the case of Li, the standard sample cone and enhanced pumping configuration gave the maximum sensitivity. In addition to improved ion transmission, the X skimmer cone geometry is also associated with additional contributions to the instrumental mass fractionation (at least in the case of Nd) that do not have a simple exponential dependence on the isotope mass. Neodymium isotope ratios measured using the X cone displayed large deviations (up to ∼750 ppm) from the reference (i.e. ‘true’) values. Similar deviations have been reported previously when using high sensitivity skimmer cone geometries on the Nu MC-ICP-MS instruments (K. Newman et al., J. Anal. At. Spectrom., 2009, 24, 742). The reported non-linear contribution to the instrumental mass fractionation with respect to Nd is not specific to a particular MC-ICP-MS instrument; it is associated with an increase in the NdO+/Nd+ ratio, due to either a change in the plasma operating conditions (e.g. an increase in the sample gas flow, absence of a secondary discharge at the interface, change in plasma gas composition) or modification of the cone geometry. The role of secondary discharge formation and the physical and chemical processes occurring in the supersonic expansion with respect to NdO+ formation are discussed.

Graphical abstract: Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes

Article information

Article type
Paper
Submitted
28 Jul 2011
Accepted
31 Oct 2011
First published
18 Nov 2011

J. Anal. At. Spectrom., 2012,27, 63-70

Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes

K. Newman, J. Anal. At. Spectrom., 2012, 27, 63 DOI: 10.1039/C1JA10222B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements