Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Issue 8, 2011
Previous Article Next Article

Non-invasive measurement of carbon monoxide burden in Guatemalan children and adults following wood-fired temazcal (sauna-bath) use

Author affiliations

Abstract

The use of wood-fired steam baths, or temazcales, is a potentially dangerous source of CO exposure in Guatemalan Highland communities where adults and children use them regularly for bathing, relaxation, and healing purposes. Physical characteristics of children predispose them to absorb CO faster than adults, placing them at greater exposure and health risks. Efforts to quantify temazcal exposures across all age groups, however, have been hampered by the limitations in exposure measurement methods. In this pilot study we measured COHb levels in children and adults following use of the temazcal using three field-based, non-invasive CO measurement methods: CO-oximetry, exhaled breath, and by estimation of COHb using micro-environmental concentrations and time diaries. We then performed a brief comparison of methods. Average CO concentrations measured during temazcal use were 661 ± 503 ppm, approximately 10 times the 15 min WHO guideline. Average COHb levels for all participants ranged from 12–14% (max of 30%, min 2%), depending on the method. COHb levels measured in children were not significantly different from adults despite the fact that they spent 66% less time exposed. COHb measured by CO-oximetry and exhaled breath had good agreement, but precision of the former was affected substantially by random instrument error. The version of the field CO-oximeter device used in this pilot could be useful in screening for acute CO exposure events in children but may lack the precision for monitoring the burden from less extreme, but more day-to-day CO exposures (e.g. indoor solid fuel use). In urban settings, health effects in children and adults have been associated with chronic exposure to ambient CO concentrations much lower than measured in this study. Future research should focus on reducing exposure from temazcales through culturally appropriate modifications to their design and practices, and targeted efforts to educate communities on the health risks they pose and actions they can take to reduce this risk.

Graphical abstract: Non-invasive measurement of carbon monoxide burden in Guatemalan children and adults following wood-fired temazcal (sauna-bath) use

Back to tab navigation

Supplementary files

Additions and corrections

Article information


Submitted
18 Feb 2011
Accepted
12 May 2011
First published
20 Jun 2011

J. Environ. Monit., 2011,13, 2172-2181
Article type
Paper

Non-invasive measurement of carbon monoxide burden in Guatemalan children and adults following wood-fired temazcal (sauna-bath) use

N. Lam, M. Nicas, I. Ruiz-Mercado, L. M. Thompson, C. Romero and K. R. Smith, J. Environ. Monit., 2011, 13, 2172
DOI: 10.1039/C1EM10172B

Search articles by author

Spotlight

Advertisements