Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene

Abstract

The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital working environment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3–4.3 ng m−3). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD ≤ 0.1 ng m−3). Negative results detected at filter samples indicate that CP determined at Strata X samples was most probably of gaseous origin. Surface contamination ranged from <2 to 19, <8 to 418 and 133–15 500 pg cm−2 at the storage room, preparation room and outpatient clinic, respectively. The study showed that evaporation of antineoplastic drugs should not be neglected, albeit the concentrations determined in our study are relatively low. Therefore, proper monitoring of airborne contamination should involve simultaneous sampling of both particle-bonded and gaseous phases. In this way, Strata X sorbent tubes seem to be an effective tool for the sampling of gaseous CP in the indoor air.

Graphical abstract: Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene

Article information

Article type
Paper
Submitted
26 Nov 2010
Accepted
08 Mar 2011
First published
06 Apr 2011

J. Environ. Monit., 2011,13, 1480-1487

Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene

P. Odraska, L. Dolezalova, P. Piler, M. Oravec and L. Blaha, J. Environ. Monit., 2011, 13, 1480 DOI: 10.1039/C0EM00660B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements