Issue 4, 2010

The effect of electrospray solvent composition on desorption electrospray ionisation (DESI) efficiency and spatial resolution

Abstract

In desorption electrospray ionisation (DESI) the interaction between the electrospray and the surface is key to two important analytical parameters, the spatial resolution and the sensitivity. We evaluate the effect of the electrospray solvent type, organic solvent fraction with water, analyte solubility and substrate wettability on DESI erosion diameter and material transferral into useful ion signal. To do this five amino acids, glycine, alanine, valine, leucine and phenylalanine are prepared as thin films on three substrates, UV/ozone treated glass, glass and polytetrafluoroethylene (PTFE). Four different solvents, acetonitrile (ACN), methanol (MeOH), ethanol (EtOH) and propan-2-ol (IPA), are used with organic solvent fractions with water varying from 0.1 to 1. These model systems allow the solubility or wettability to be kept constant as other parameters are varied. Additionally, comparison with electrospray ionisation (ESI) allows effects of ionisation efficiency to be determined. It is shown that the DESI efficiency is linearly dependent on the solubility (for these materials at least) and for analytes with solubilities below 1.5 g kg−1, additional strategies may be required for DESI to be effective. We show that the DESI erosion diameter improves linearly with organic solvent fraction, with an organic solvent fraction of 0.9 instead of 0.5 leading to a 2 fold improvement. Furthermore, this leads to a 35 fold increase in DESI efficiency, defined as the molecular ion yield per unit area. It is shown that these improvements correlate with smaller droplet sizes rather than surface wetting or ionisation.

Graphical abstract: The effect of electrospray solvent composition on desorption electrospray ionisation (DESI) efficiency and spatial resolution

Supplementary files

Article information

Article type
Paper
Submitted
18 Nov 2009
Accepted
06 Jan 2010
First published
20 Jan 2010

Analyst, 2010,135, 731-737

The effect of electrospray solvent composition on desorption electrospray ionisation (DESI) efficiency and spatial resolution

F. M. Green, T. L. Salter, I. S. Gilmore, P. Stokes and G. O'Connor, Analyst, 2010, 135, 731 DOI: 10.1039/B924208B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements