Abstract

We present a lateral cavity acoustic transducer (LCAT) capable of pumping and mixing fluids within a microfluidic system using an acoustic energy source from an external piezoelectric buzzer. The device is capable of pumping at flow rates of approximately 250 nl min−1 and real-time mixing in low flow rate (<1 µl min−1) devices typical in microfluidic systems.

Graphical abstract: Lateral cavity acoustic transducer

Supplementary files

Article information

Article type
Communication
Submitted
21 Jul 2008
Accepted
14 Oct 2008
First published
24 Oct 2008

Lab Chip, 2009,9, 41-43

Lateral cavity acoustic transducer

A. R. Tovar and A. P. Lee, Lab Chip, 2009, 9, 41 DOI: 10.1039/B812435C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.