Issue 4, 2009

Automated molecular formula determination by tandem mass spectrometry (MS/MS)

Abstract

Automated software was developed to analyze the molecular formula of organic molecules and peptides based on high-resolution MS/MS spectroscopic data. The software was validated with 96 compounds including a few small peptides in the mass range of 138–1569 Da containing the elements carbon, hydrogen, nitrogen and oxygen. A Micromass Waters Q-TOF Ultima Global mass spectrometer was used to measure the molecular masses of precursor and fragment ions. Our software assigned correct molecular formulas for 91 compounds, incorrect molecular formulas for 3 compounds, and no molecular formula for 2 compounds. The obtained 95% success rate indicates high reliability of the software. The mass accuracy of the precursor ion and the fragment ions, which is critical for the success of the analysis, was high, i.e. the accuracy and the precision of 850 data were 0.0012 Da and 0.0016 Da, respectively. For the precursor and fragment ions below 500 Da, 60% and 90% of the data showed accuracy within ≤0.001 Da and ≤0.002 Da, respectively. The precursor and fragment ions above 500 Da showed slightly lower accuracy, i.e. 40% and 70% of them showed accuracy within ≤0.001 Da and ≤0.002 Da, respectively. The molecular formulas of the precursor and the fragments were further used to analyze possible mass spectrometric fragmentation pathways, which would be a powerful tool in structural analysis and identification of small molecules. The method is valuable in the rapid screening and identification of small molecules such as the dereplication of natural products, characterization of drug metabolites, and identification of small peptide fragments in proteomics. The analysis was also extended to compounds that contain a chlorine or bromine atom.

Graphical abstract: Automated molecular formula determination by tandem mass spectrometry (MS/MS)

Supplementary files

Article information

Article type
Paper
Submitted
20 Oct 2008
Accepted
12 Jan 2009
First published
05 Feb 2009

Analyst, 2009,134, 690-700

Automated molecular formula determination by tandem mass spectrometry (MS/MS)

S. Jarussophon, S. Acoca, J. Gao, C. Deprez, T. Kiyota, C. Draghici, E. Purisima and Y. Konishi, Analyst, 2009, 134, 690 DOI: 10.1039/B818398H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements