Issue 8, 2008

Precise measurement of 228Ra/226Ra for 226Ra determination employing total integration and simultaneous 228Th correction by multicollector ICP-MS using multiple ion counters

Abstract

A precise method of measuring 228Ra/226Ra for 226Ra determination used in U-series disequilibrium studies has been developed using the total integration method with simultaneous 228Th isobaric interference correction by multicollector ICP-MS with multiple ion counters (MIC). A sample solution of 0.2 ml was separately taken into a test tube, and all 226Ra+ and 228Ra+ signals as well as 229Th+ and 228Th16O+ from beginning to end were integrated simultaneously using four channeltrons, IC1, IC3, IC4 and IC5, respectively. Gains between IC1 and IC3 and the mass discrimination factor for 228Ra/226Ra determination were canceled out by measurement of a Ra spike solution with an accurately known Ra isotope ratio determined by TIMS, with which samples were bracketed. The isobaric interferences of 228Th+ were simultaneously corrected from the signal of 228Th16O+ and the oxide forming ratio of 228Th, which was separately determined by simultaneous measurements of 229Th+ and 229Th16O+ by IC3 and IC5. The gains between IC3 and IC5 for the Th correction were also canceled out. The ion yield of Ra in MIC-ICP-MS was ∼1.5%. The intermediate precision using 6.6, 3.3, 1.7, 0.83 and 0.41 fg of 226Ra with 228Ra/226Ra = ∼5 was 0.33, 0.93, 0.76, 1.6 and 1.5%, respectively. The 228Ra/226Ra ratio showed no systematic change dependent on 228Th/228Ra up to 0.25, indicating the validity of the 228Th correction. At similar amounts of Ra, our method gives intermediate precision values similar to or better than previous MC-ICP-MS and TIMS studies. The precision of the method was verified using another Ra spike with 228Ra/226Ra = ∼1 determined by TIMS. The analytical performance of the method was further investigated using the silicate samples JB-2 and JB-3 basalts issued by GSJ.

Graphical abstract: Precise measurement of 228Ra/226Ra for 226Ra determination employing total integration and simultaneous 228Th correction by multicollector ICP-MS using multiple ion counters

Article information

Article type
Paper
Submitted
01 May 2008
Accepted
10 Jun 2008
First published
27 Jun 2008

J. Anal. At. Spectrom., 2008,23, 1102-1107

Precise measurement of 228Ra/226Ra for 226Ra determination employing total integration and simultaneous 228Th correction by multicollector ICP-MS using multiple ion counters

A. Makishima, T. A. Chekol and E. Nakamura, J. Anal. At. Spectrom., 2008, 23, 1102 DOI: 10.1039/B807431C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements