μFlow-injection–ICP collision cell MS determination of molybdenum, nickel and vanadium in petroleum samples using a modified total consumption micronebulizer

Abstract

An interface based on a total consumption micronebulizer was developed for the introduction of xylene solutions into ICP MS. The increase in the nebulizer capillary diameter and the elimination of the internal connections reduced the problem of clogging, pressure instability and memory effects. The xylene carrier could be introduced for several hours at a rate of 30 μl min−1. The sample (2.5 μl) was injected into the carrier flow to produce peaks of 5 s at half-height (20 s at the base) which allowed a throughput of ca. 100 h−1 for the simultaneous determination of Mo, Ni and V. Calibration curves with good linearity (R2 > 0.999) over at least three orders of magnitude and detection limits at the sub-ng ml−1 levels were obtained. The method was validated by the analysis of a sample by an independent (ICP AES) method and by the analysis of a NIST CRM 1085c lubricating oil material. The use of a helium-pressurized collision cell was essential to obtain good accuracy for Ni and V but was not required for Mo.

Graphical abstract: μFlow-injection–ICP collision cell MS determination of molybdenum, nickel and vanadium in petroleum samples using a modified total consumption micronebulizer

Supplementary files

Article information

Article type
Technical Note
Submitted
09 Aug 2006
Accepted
12 Sep 2006
First published
05 Oct 2006

J. Anal. At. Spectrom., 2007,22, 88-92

μFlow-injection–ICP collision cell MS determination of molybdenum, nickel and vanadium in petroleum samples using a modified total consumption micronebulizer

P. Giusti, Y. Nuevo Ordóñez, C. Philippe Lienemann, D. Schaumlöffel, B. Bouyssiere and R. Łobiński, J. Anal. At. Spectrom., 2007, 22, 88 DOI: 10.1039/B611542J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements