A single component ratiometric pH probe with long wavelength excitation of europium emission

Author affiliations

Abstract

Following excitation in the range 370–405 nm, the emission spectrum of a cell permeable macrocyclic Eu(III) complex incorporating an N-methylsulfonamide moiety changes form with pH, allowing ratiometric pH measurements in the range 6 to 8.

Graphical abstract: A single component ratiometric pH probe with long wavelength excitation of europium emission

Back to tab navigation

Supplementary files

Article information


Submitted
15 Nov 2006
Accepted
30 Nov 2006
First published
13 Dec 2006

Chem. Commun., 2007, 474-476
Article type
Communication

A single component ratiometric pH probe with long wavelength excitation of europium emission

R. Pal and D. Parker, Chem. Commun., 2007, 474
DOI: 10.1039/B616665B