Issue 7, 2006

Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline

Abstract

A molecularly imprinted polymer solid phase extraction (MISPE) method combined with flow-injection chemiluminescence (FI-CL) for the determination of residual tetracycline (TC) in fish samples is presented. The molecularly imprinted polymer (MIP) of TC was synthesized and particles of this MIP were packed into a polytetrafluoroethylene (PTFE) tube, which was connected into the sampling loop of an eight-way injection valve and served as the MISPE column for on-line selective adsorption of TC. The eluent (CH3CN : HNO3 (0.01 mol L−1) = 4 ∶ 1, v ∶ v) was used for extracting the adsorbed TC, which could be detected by its good enhancing effect on the CL reaction between Ce(IV) and rhodamine B. The CL intensity is linear to TC concentration in the range from 4 × 10−9 to 4 × 10−7 g mL−1. The detection limit is 1 × 10−9 g mL−1 (3σ) and the relative standard deviation is 2.4% (n = 9). The conditions of preconcentration, extraction and CL reaction were carefully studied. The selectivity experiment shows that the selectivity and sensitivity of the CL method could be improved greatly when MIP was used as a recognition material in SPE. However, the MISPE column interacted indiscriminately with oxytetracycline (OTC) with a 49 ± 2% binding. An intermediate differential pulsed elution (DPE) step using 3% acetic acid as eluent was employed to remove OTC and other interfering substances. The proposed MISPE-CL method has been applied successfully to the determination of TC in fish samples. At the same time, the binding characteristics of the polymer to tetracycline were evaluated by batch and dynamic methods.

Graphical abstract: Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline

Article information

Article type
Paper
Submitted
14 Oct 2005
Accepted
12 May 2006
First published
06 Jun 2006

Analyst, 2006,131, 829-834

Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline

Y. Xiong, H. Zhou, Z. Zhang, D. He and C. He, Analyst, 2006, 131, 829 DOI: 10.1039/B606779B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements