Issue 9, 2005

Quantitative determination of selenium metabolites in human urine by LC-DRC-ICP-MS

Abstract

Two selenium metabolites, Se-methylseleno-N-acetylgalactosamine (SeGal-N-Ac) and Se-methylselenogalactosamine (SeGal-NH2), were quantified in human urine by LC-DRC-ICP-MS. Urine samples were analysed after 1 + 1 dilution in a reversed phase chromatographic system using an eluent consisting of 200 mM ammonium acetate and 5% methanol with a pH of 9.25 and quantified by standard addition. Samples were collected from 8 volunteers before and after 5 days ingestion of 100 μg Se day−1 in form of selenized yeast. The average concentration of (SeGal-NH2) before and after selenium intake was 1.4 and 1.9 μg Se L−1, respectively, while the average concentration of Se-Gal-N-Ac increased from 2.6 to 11.6 μg Se L−1 before and after selenium consumption. Detection limits calculated on basis of three times the standard deviation on peak areas of 2 μg Se L−1 solutions were 0.1 μg Se L−1 for SeGal-NH2 and 0.2 μg Se L−1 for SeGal-N-Ac based on peak areas and monitoring 80Se. The precision expressed as the relative standard deviation (n = 6) at the 2 μg Se L−1 level was 3.1 and 1.7% for SeGal-NH2 and SeGal-N-Ac, respectively, while the corresponding values were 1.0 and 0.7% at the 10 μg Se L−1 level. Linearity in urine matrix was examined in the range 0.5–100 μg Se L−1 and correlation coefficients better than 0.999 were obtained. As the cationic compound SeGal-NH3+ may be confounded with the trimethylselenonium ion (TMSe+), urine samples were also analysed in a cation exchange chromatographic system in which SeGal-NH3+ was separated from the trimethylselenonium ion. None of the samples contained TMSe+ in detectable amounts. Three sample introduction systems were compared—a microconcentric nebuliser in combination with a cyclonic spray chamber (MCN), a direct injection nebuliser (DIN) and an ultrasonic nebuliser (USN). The MCN was most suitable for this purpose.

Graphical abstract: Quantitative determination of selenium metabolites in human urine by LC-DRC-ICP-MS

Article information

Article type
Paper
Submitted
04 Apr 2005
Accepted
02 Jun 2005
First published
23 Jun 2005

J. Anal. At. Spectrom., 2005,20, 889-893

Quantitative determination of selenium metabolites in human urine by LC-DRC-ICP-MS

B. Gammelgaard, L. Bendahl, N. Wessel Jacobsen and S. Stürup, J. Anal. At. Spectrom., 2005, 20, 889 DOI: 10.1039/B504612B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements