Issue 7, 2005

Quantitative trace-element analysis of diamond by laser ablation inductively coupled plasma mass spectrometry

Abstract

Laser ablation microprobe ICP-MS has been used to determine quantitatively the trace-element composition of diamond. Experiments with different synthetic multi-element carbon-based standards, various lasers and a range of instrument conditions have shown that a 266 nm UV laser at 10 Hz provided the best sensitivity, and synthetic oil and a doped cellulose proved most suitable as external standards; 13C was used as the internal standard. The precision and accuracy of the method, and the homogeneity of the cellulose multi-element standard, were tested by multiple analyses. Artefacts resulting from polyatomic interferences were quantified by analysis of a pure synthetic diamond. Concentrations of 41 elements were determined for two fibrous diamonds from Jwaneng in Botswana (JWA 110 and JWA 115), which have been analysed previously by instrumental neutron-activation analysis (INAA) and proton microprobe (PIXE). A comparison of these three analytical techniques shows that the use of the cellulose standard produces accurate and precise data for most elements. Typical detection limits for the rare earth elements are 5–20 ppb, and for transition elements <500 ppb. Sodium and Fe have higher detection limits (2–3 ppm). The precision (expressed as % rsd) ranges through ∼10% for concentrations between 1–100 ppm, ∼15% for values between 0.1–1 ppm, ∼30% for 0.01–0.1 ppm and ∼25% for values <0.01 ppm, with the accuracy lying in the same range. The trace-element patterns obtained by this technique may be used for the characterisation of diamond in genetic studies. Further analyses are required to test whether reliable identification of the source locality of the diamonds is possible; if so this may have important forensic applications.

Graphical abstract: Quantitative trace-element analysis of diamond by laser ablation inductively coupled plasma mass spectrometry

Article information

Article type
Paper
Submitted
27 Jan 2005
Accepted
25 Apr 2005
First published
13 May 2005

J. Anal. At. Spectrom., 2005,20, 601-611

Quantitative trace-element analysis of diamond by laser ablation inductively coupled plasma mass spectrometry

S. Rege, S. Jackson, W. L. Griffin, R. M. Davies, N. J. Pearson and S. Y. O’Reilly, J. Anal. At. Spectrom., 2005, 20, 601 DOI: 10.1039/B501374G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements