Issue 5, 2005

Development of an ambient temperature post-column oxidation system for high-performance liquid chromatography on-line coupled with cold vapor atomic fluorescence spectrometry for mercury speciation in seafood

Abstract

An efficient ambient temperature post-column oxidation system was developed for high-performance liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry for mercury speciation analysis in seafood. The developed system does not require an external heat source, such as a hot water bath, microwave heating or UV irradiation, to decompose organomercury compounds into inorganic mercury ion (Hg(II)). Methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg) and Hg(II) were baseline separated on an RP-C18 column with a mixture of methanol, acetonitrile and water (75 ∶ 5 ∶ 20) containing 0.01% m/v ammonium pyrrolidine dithiocarbamate (APDC) (pH 3.5) as the mobile phase. Online ambient temperature post-column oxidation of organomercury species eluted from the HPLC column was achieved by mixing the effluent with a 3% m/v K2S2O8 in 10% v/v HCl solution in a knotted reactor made of a 0.5 mm id × 200 cm long PTFE tube. The developed oxidation approach enhanced sensitivity for organomercury by a factor of 4 for MeHg, 3 for EtHg and 6 for PhHg, compared with that obtained without post-column oxidation. The detection limits for 100 μl injection were 0.19–0.27 μg l−1 (as Hg) in extract, corresponding to 4.75–6.75 μg kg−1 (as Hg) in fish tissue for a 50 ml final extract of 2 g tissue. The precision (RSD, n = 5) ranged from 1.8 to 2.8% for peak area, and from 1.7% to 2.9% for peak height at the 1 μg l−1 (as Hg) level. The method was validated by determination of methylmercury in a certified reference material (DORM-2, dogfish muscle) and applied to the speciation analysis of mercury in local seafood samples.

Graphical abstract: Development of an ambient temperature post-column oxidation system for high-performance liquid chromatography on-line coupled with cold vapor atomic fluorescence spectrometry for mercury speciation in seafood

Article information

Article type
Paper
Submitted
27 Aug 2004
Accepted
21 Feb 2005
First published
07 Mar 2005

J. Anal. At. Spectrom., 2005,20, 467-472

Development of an ambient temperature post-column oxidation system for high-performance liquid chromatography on-line coupled with cold vapor atomic fluorescence spectrometry for mercury speciation in seafood

Y. Li, X. Yan, L. Dong, S. Wang, Y. Jiang and D. Jiang, J. Anal. At. Spectrom., 2005, 20, 467 DOI: 10.1039/B413206H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements