Jump to main content
Jump to site search

Issue 6, 2004
Previous Article Next Article

Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sector inductively coupled plasma mass spectrometry with a desolvating introduction system

Author affiliations

Abstract

The Centers for Disease Control and Prevention has a mission to protect and promote public health, which includes investigation of environmental exposures to toxic substances that could threaten health. Plutonium is an environmentally available substance that is chemically and radiologically toxic and represents a potential health threat from excessive exposure. Inductively coupled plasma mass spectrometry (ICP-MS) is a sensitive method for assessing environmental or unintentional exposure to these and other actinides. We report here a magnetic sector instrument method in which a desolvating introduction system is used to provide rapid, sensitive emergency response analysis for 239Pu in only 1 mL of urine without digestion or coprecipitation. 239Pu was separated from U and interfering urine organic substances by solid phase extraction. The within run limit of detection (LOD) was 0.16 fg mL−1 for 1 mL of urine even though originally spiked to 1018 ng L−1 of depleted U. A more rigorous LOD of 1.4 fg mL−1239Pu was based on 3 “total” standard deviations in the presence of the same U concentration. At below 106 atoms of 239Pu detectable in 1 mL of urine, this method is sufficiently sensitive for elevated emergency exposure assessment with high throughput. The precision for 10 duplicate samples was within 3.7% relative “total” standard deviation (RSD, within and between run) for a 9.96 fg mL−1239Pu-spiked urine sample and within 2.2% for a 99.6 fg mL−1239Pu-spiked urine sample. The method was demonstrated to be accurate within 2.6% of the Los Alamos National Laboratories target value at 99.6 fg mL−1, to within 1.0% of target value at 9.96 fg mL−1 and within 1.2% at 0.996 fg mL−1, just below the method LOD.

Back to tab navigation

Publication details

The article was received on 23 Dec 2003, accepted on 12 Mar 2004 and first published on 20 May 2004


Article type: Paper
DOI: 10.1039/B316851D
Citation: J. Anal. At. Spectrom., 2004,19, 762-766

  •   Request permissions

    Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sector inductively coupled plasma mass spectrometry with a desolvating introduction system

    R. S. Pappas, B. G. Ting and D. C. Paschal, J. Anal. At. Spectrom., 2004, 19, 762
    DOI: 10.1039/B316851D

Search articles by author

Spotlight

Advertisements