Issue 8, 2003

Development of adenosine sensor: effect of physiological buffers on activity and sensitivity in adenosine determinations by fast scan voltammetry

Abstract

A new fast scan voltammetry (FSV) method was tested in the determinations of adenosine in physiological buffers at pH 7.4. The buffers can be used in the determinations of adenosine in vivo and include 7 × 10−2 M phosphate, Krebs–Henseleit (K-H) and Hanks' Balanced Salts (HBSS). A new method of fabrication of carbon fiber electrodes (CFEs) by polishing, followed by electrochemical pretreatment (ECP) was developed for the determination. After the ECP of CFE, CFE background current was stable in FSV determinations even though an increase in the background current was observed after the ECP in the buffers at pH 7.4. The sensitivity in FSV determinations of adenosine at the pretreated electrodes was tested in the physiological buffers at the potential scan rate of 500 V s−1 at pH 7.4. Buffer composition and pH was the same during the ECP of CFE and in the FSV determinations. The sensitivity in the FSV determinations of adenosine at the new CFEs was high, compared to that previously reported at CFEs prepared by other methods, and showed a limited dependence on buffer composition. However, a small increase in buffer pH above 7.4 resulted in a decrease in sensitivity in the determinations of adenosine. The decrease in sensitivity was associated with an additional increase in CFE background current at pH > 7.4. At pH 7.4 best sensitivity and limit of detection was obtained in 7 × 10−2 M phosphate buffer, where the background current was lowest. The sensitivity was half that in K-H and HBSS. Standard deviation of measurements was ca. 1%. The results demonstrate the feasibility of sensitive FSV determinations of adenosine in physiological buffers at pH 7.4 at CFEs.

Article information

Article type
Paper
Submitted
07 Mar 2003
Accepted
30 May 2003
First published
25 Jun 2003

Analyst, 2003,128, 1056-1061

Development of adenosine sensor: effect of physiological buffers on activity and sensitivity in adenosine determinations by fast scan voltammetry

K. A. El-Nour and A. Brajter-Toth, Analyst, 2003, 128, 1056 DOI: 10.1039/B302672H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements