Several novel W-filament designs are investigated and compared as atomization devices for blood Pb measurements by atomic absorption spectrometry. Two designs (short and long wire filaments) are based on rigidly-wound W-filaments from Osram, while a third (etched filament) is based on lithographic imaging and photoetching technology. The filaments are positioned in an aluminum atomization cell that is mounted in the optical path of a compact AAS instrument. This instrument is designed specifically for blood lead testing using W-filament technology with a Pb hollow cathode lamp and incorporates a self-reversal background correction system. Whole blood is diluted 1 + 4 with a phosphate modifier, Triton X-100 and nitric acid, and 15 µL are deposited on the filament using a micropipette. A simple heating program dries, pyrolyzes and atomizes the sample. Integrated absorbance measurements are used for improved precision and detection limits. Matrix-matched Pb standards are necessary for blood lead calibration. Of the three filaments studied, the long wire filament proved most suitable, with a characteristic mass (m0) of 200 pg, a method detection limit (3σ) of1–2 µg dL−1 (0.05–0.10 µmol L−1), and a lifetime of the order of 60–70 firings. Method accuracy is verified using blood lead reference materials from the National Institute of Standards and Technology (SRM 955a,b), the Centers for Disease Control (BLLRS) and the New York State Department of Health (RMs 028, 040, and 043). For the long wire filament, blood lead results below 40 µg dL−1 were mostly within ±1 µg dL−1 of certified values, and within ±10% above 40 µg dL−1; within-run precision was almost always better than ±10%. Additional validation is reported using proficiency test materials and human blood specimens. All blood lead results were within the acceptable limits established by regulatory authorities in the US.

Article information

Article type
Paper
Submitted
14 Aug 2000
Accepted
01 Nov 2000
First published
13 Dec 2000

J. Anal. At. Spectrom., 2001,16, 82-89

Atomization of lead from whole blood using novel tungsten filaments in electrothermal atomic absorption spectrometry

Y. Zhou, P. J. Parsons, K. M. Aldous, P. Brockman and W. Slavin, J. Anal. At. Spectrom., 2001, 16, 82 DOI: 10.1039/B006644N

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements