Issue 5, 2000

Abstract

Five different instruments for the determination of the mass concentration of PM10 in air were compared side-by-side for up to 33 days in an undisturbed indoor environment: a tripod mounted BGI Inc. PQ100 gravimetric sampler with a US EPA certified Graseby Andersen PM10 inlet; an Airmetrics Minivol static gravimetric sampler; a Casella cyclone gravimetric personal sampler; an Institute of Occupational Medicine gravimetric PM10 personal sampler; and two TSI Inc. Dustrak real-time optical scattering personal samplers. For 24 h sampling of ambient PM10 concentrations around 10 µg m−3, the estimated measurement uncertainty for the two gravimetric personal samplers was larger (∼±20%) compared with estimated measurement uncertainty for the PQ100/Graseby Andersen sampler (<±5%). Measurement uncertainty for the Dustraks was lower (∼±15% on average) but calibration of the optical response against a reference PM10 method is essential since the Dustraks systematically over-read PM10 determined gravimetrically by a factor ∼2.2. However, once calibrated, the Dustrak devices demonstrated excellent functionality in terms of ease of portability and real-time data acquisition. Estimated measurement uncertainty for PM10 concentrations determined with the Minivol were ±5%. The Minivol data correlated well with PQ100/Graseby Andersen data (r = 0.97, n = 18) but were, on average, 23% greater. The reason for the systematic discrepancy could not be traced. Intercomparison experiments such as these are essential for assessing measurement error and revealing systematic bias. Application of two Dustraks demonstrated the spatial and temporal variability of exposure to PM10 in different walking and transport microenvironments in the city of Edinburgh, UK. For example, very large exposures to PM10 were identified for the lower deck of a double-decker tour bus compared with the open upper deck of the same vehicle. The variability observed emphasises the need to determine truly personal exposure profiles of PM10 for quantifying exposure–response relationships for epidemiological studies.

Article information

Article type
Paper
Submitted
06 Apr 2000
Accepted
06 Jul 2000
First published
17 Aug 2000

J. Environ. Monit., 2000,2, 455-461

Intercomparison of five PM10 monitoring devices and the implications for exposure measurement in epidemiological research

M. R. Heal, I. J. Beverland, M. McCabe, W. Hepburn and R. M. Agius, J. Environ. Monit., 2000, 2, 455 DOI: 10.1039/B002741N

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements