Alkylating vaporisation of antimony using tungsten boat furnace-sample cuvette technique for inductively coupled plasma mass spectrometry

Abstract

A fully automated procedure was developed for the determination of (ultra)trace lead in biological materials by on-line coupling flow injection (FI) microcolumn separation and preconcentration with electrothermal atomic absorption spectrometry (ETAAS) using a macrocycle immobilized silica gel sorbent (Pb-02). The analyte was selectively and efficiently collected on a conically shaped column (50 µl) packed with Pb-02 over a wide range of sample acidity (0.08-≥3 mol l –1 HNO 3 ). Quantitative elution of the retained analyte from the column was achieved with 46 µl of 0.03 mol l –1 ethylenediamine tetraacetic acid (EDTA) solution at pH 10.5. The eluate was driven with an air flow into the graphite tube preheated to 110 °C. No precise timing was needed during analyte elution and eluate introduction. When 0.15 mol l –1 HNO 3 was used as the wash medium and the residual solution was removed from the column and connecting tubes by air before elution, the only potential interferents were found to be Ba(II), Sr(II) and K(I) due to their competition for the cavity of the macrocyclic compound because their ionic radii are similar to that of Pb(II). Nevertheless, these potential interferences were eliminated or minimized by a proper increase of eluent volume and/or EDTA concentration. Under the optimized conditions, the tolerated concentrations of Ba(II), Sr(II) and K(I) were at least 10, 100 and 5000 mg l –1 in the digest, respectively. With a sample loading rate of 3 ml min –1 and a 20-s preconcentration time, an enhancement factor of 23 and a sampling frequency of 23 h –1 with a collection efficiency of 70% were obtained. The detection limit (3s) was found to be 2 ng l –1 . The relative standard deviation (n=9) was 2.9% at the 500 ng l –1 Pb level. The results for a number of standard reference materials (rice flour, blood and urine) demonstrated the applicability of the proposed method to the analysis of biological materials with simple aqueous standards for calibration.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1999,14, 1631-1632

Alkylating vaporisation of antimony using tungsten boat furnace-sample cuvette technique for inductively coupled plasma mass spectrometry

Y. Okamoto, J. Anal. At. Spectrom., 1999, 14, 1631 DOI: 10.1039/A905374C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements