Issue 9, 1998

Vesicle-assisted determination of ultratrace amounts of cadmium in urine by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

Abstract

Two methods for the determination of ultratrace amounts of Cd, based on vesicular hydride generation, includingin situ trapping electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS), are described and compared for Cd determination in urine. The human urine samples are diluted 1+1 with ultrapure water and no other sample pre-treatment is necessary. Thus, the risk of contamination at basal or ‘normal’ metal levels in urine is minimized. Using flow injection hydride generation ICP-MS (FI-HG-ICP-MS), the detection limits observed for Cd in water and urine (50 µl sample volume) were 3.5 and 7 pg, respectively, and the observed relative standard deviation for ten replicate analyses of 50 µl of a 5 µg l–1 aqueous CD solution was ±3.2%. In situtrapping allows preconcentration in the graphite tube; by preconcentrating 1.4 ml of urine the detection limit achieved by ETAAS was 10 ng l–1 (14 pg, absolute). The use of silicone as an antifoam agent for vesicular cadmium hydride generation allowed a throughput of about 20 samples h–1 by FI-HG-ICP-MS detection. The concentration of Cd in human urine was evaluated directly by aqueous standard calibration as no matrix interferences were observed for both methods under study. NIST SRM 2670 Toxic Metals in Freeze-Dried Urine was analysed by the two methods with excellent results. The accuracy of the results was demonstrated in two ways because the reported values for the SRM agreed well with the results obtained using either of the two methods under investigation.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1998,13, 899-903

Vesicle-assisted determination of ultratrace amounts of cadmium in urine by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

H. Goenaga Infante, M. L. Fernández Sánchez and A. Sanz-medel\, J. Anal. At. Spectrom., 1998, 13, 899 DOI: 10.1039/A801610K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements