Open Access Article
This Open Access Article is licensed under a
Creative Commons Attribution 3.0 Unported Licence

Correction: Nanosheet-pore topographical titanium substrates: a biophysical regulator of the fate of mesenchymal stem cells

Kui Xu, Xinkun Shen, Weizhen Chen, Caiyun Mu, Chao Jiang, Yongchun Zhao and Kaiyong Cai*
Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, P. R. China. E-mail: kaiyong_cai@cqu.edu.cn; Tel: +86-23-65102507

Received 4th June 2026 , Accepted 4th June 2026

First published on 23rd June 2026


Abstract

Correction for ‘Nanosheet-pore topographical titanium substrates: a biophysical regulator of the fate of mesenchymal stem cells’ by Kui Xu et al., J. Mater. Chem. B, 2016, 4, 1797–1810, https://doi.org/10.1039/C5TB02391B.


The authors regret errors in Fig. 6B, 7A, 8A and 9A in the published article which occurred during the manuscript revision process.

The corrected Fig. 6B, 7A, 8A and 9A are shown here (the captions remain unchanged). The authors declare that these errors do not impact the overall findings and conclusions of the article.


image file: d6tb90086k-f6.tif
Fig. 1 (B) representative fluorescence images of MSCs adhered to different substrates (scale bar is 50 μm for the columns Vinculin, F-Actin, Nuclei and Merge and 20 μm for the enlarged images).

image file: d6tb90086k-f7.tif
Fig. 2 (A) representative fluorescence images of MSCs cultured on different substrates (scale bar, 200 μm).

image file: d6tb90086k-f8.tif
Fig. 3 ALP staining of MSCs cultured on different substrates and TCPS with normal medium (NM) and osteoinductive medium (OM) for 4 and 7 days (scale bar, 1 mm).

image file: d6tb90086k-f9.tif
Fig. 4 (A) Representative images of cells stained with Alizarin Red S (scale bar, 1 mm).

In Fig. 6B the panel for M-TNSs Nuclei was incorrect and has been updated.

In Fig. 7A the panels for 1D L-TNSs, 4D S-TNSs, 7D Ti and 7D M-TNSs were incorrect and have been updated.

In Fig. 8A the panels for 4 days NM TCPS and 7 days NM Ti were incorrect and have been updated.

An impurity is visible on the right-hand side of some of the panels. This was present on the microscope lens when the data was collected and does not affect the results presented in Fig. 8A.

In Fig. 9A the panels for NM S-TNSs and OM S-TNSs were incorrect and have been updated.

An independent expert has viewed the corrected figures and confirmed that they are consistent with the discussions and conclusions presented.

The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.


This journal is © The Royal Society of Chemistry 2026