Incremental capacity analysis (ICA) is widely used to probe lithium-ion battery degradation because it preserves material-related information in the voltage response. Its mechanistic value, however, depends on whether the measured voltage trajectory provides a comparable projection of electrode phase responses, polarization, and transport limitations. Here, we show that insufficient pre-charge relaxation introduces a relaxation-induced kinetic masking that can distort ICA fingerprints before material-related interpretation. A controlled-aging dataset of 12 commercial NMC-type 21
700 cells and 166 reference performance tests was used, in which four ICA-related charges with 60, 30, 10, and 0 min of pre-charge relaxation were repeatedly conducted under otherwise identical conditions within each test. Short relaxation first shifts the charging-voltage trajectory and then amplifies this deviation in the dQ/dU domain, producing peak displacement, centroid drift, and area redistribution within reproducible fingerprint windows. The distortion depends systematically on charge rate, depth of discharge, state of health, and voltage window, indicating that it is a structured non-equilibrium projection. To mitigate this protocol-induced masking, we developed a voltage-domain relaxation lens based on an effective voltage-dependent relaxation timescale, τ(U), a compact, effective descriptor of the transferable relaxation-induced voltage bias in the voltage domain. The framework does not aim to recover an ideal equilibrium curve; instead, it moves short-relaxation charges toward the corresponding 60-min long-rest reference before recalculating ICA. Under strict cross-cell validation, the framework improves the comparability of the P2–P4 fingerprint windows within clear boundaries: 40% depth of discharge is a stable success region, 70% is condition-dependent, and 100% remains the most challenging scenario. A temperature-aware extension provides only localized additional benefit, mainly in the hardest cases. Overall, these results show that part of the apparent evolution of ICA fingerprints under practical testing can arise from relaxation-induced kinetic masking rather than irreversible material change, and highlight relaxation standardization as a protocol-aware route toward more reliable ICA fingerprint interpretation from cycler-accessible signals. The standardized fingerprints should therefore be interpreted as long-rest-referenced responses with improved comparability.
This consideration is particularly significant for commercial layered-oxide/graphite LIB cells, where the IC response represents a superposition of positive- and negative-electrode processes.7 Graphite staging transitions, cathode phase changes, lithium redistribution, impedance growth, and variations in electrode utilization all influence the measured dQ/dU response.8–10 Under well-controlled, low-rate, or extended-rest conditions, these fingerprints can facilitate the interpretation of degradation. In practical diagnostic scenarios, however, the voltage trajectory often includes a substantial non-equilibrium component.11 Increases in current, changes in prior usage, or reduced relaxation time before charging can intensify residual polarization and concentration gradients. As a result, apparent changes in IC features should not be directly attributed to loss of lithium inventory, loss of active material, impedance growth, or phase-response evolution without accounting for protocol-induced components of the voltage response.12
Numerous efforts to enhance the practicality of ICA have focused on extracting meaningful descriptors from non-ideal charging data, such as partial charging segments, varying charge initiation states, and different charging rates.13–15 Recent studies have further advanced this direction toward minute-level ICA reconstruction from sparse charging segments, few-point electrode-level diagnosis, cloud-based IC-feature SOH estimation, and physics-informed, transferable degradation modeling.16–19 While these studies are valuable for engineering applications, they do not fully address a fundamental materials question: when the cell state and diagnostic charge conditions are otherwise constant, to what extent is observed IC variation attributable solely to the relaxation history preceding charge? Pre-charge relaxation is a critical procedural factor, as it determines the level of residual polarization and concentration imbalance present at the onset of the next diagnostic charge.20,21 If this residual non-equilibrium state persists in the voltage trajectory, it can obscure the material-specific fingerprint that ICA aims to reveal.22
This phenomenon is termed relaxation-induced kinetic masking. When relaxation is brief, the diagnostic charge arises from an altered electrochemical background that can persist during charging and modify the voltage profile of local electrode processes. After transformation into dQ/dU, even moderate voltage deviations may manifest as peak displacement, centroid drift, or area redistribution within an ICA fingerprint window.6 Apparent peak evolution can thus result from protocol-induced masking. This issue is particularly significant when ICA descriptors are used to interpret degradation mechanisms, as interpretations related to loss of active material, loss of lithium inventory, impedance, or phase response may be confounded by recent relaxation history.23
To isolate this effect, a controlled full-lifetime aging dataset comprising 12 commercial NMC-type 21
700 LIB cells was utilized. For each reference performance test, four ICA-related diagnostic charges were performed at identical charge rates and depth of discharge (DoD), with only the pre-charge relaxation duration varied among 60, 30, 10, and 0 minutes. The 60-min case serves as a practical long-rest reference, while the shorter-rest cases demonstrate how insufficient relaxation distorts the voltage trajectory and the resulting IC fingerprints. By comparing within the same cell and at the same test checkpoint, relaxation-induced masking can be more effectively distinguished from variations in cell identity, aging trajectory, diagnostic current, or DoD.
The primary objective of this study is to establish relaxation-induced ICA distortion as a structured electrochemical projection. Both the voltage domain and the dQ/dU domain are analyzed using reproducible fingerprint windows P1–P4. These windows are not interpreted as strict single-phase assignments, but rather as experimentally reproducible voltage regions encompassing overlapping contributions from electrode phase responses, thermodynamic slope changes, polarization, and lithium redistribution. The secondary objective is to determine whether a portion of this kinetic masking can be mitigated prior to material-related interpretation. To this end, a voltage-domain relaxation lens is developed, based on an effective voltage bias descriptor, τ(U). This lens is applied to the voltage trajectory before ICA recalculation, as the distortion originates in the voltage response and is subsequently amplified in dQ/dU.24
The results indicate that relaxation-induced masking is systematic, window-dependent, and condition-dependent. The τ(U)-based relaxation lens can partially align short-rest IC fingerprints with the corresponding 60-min long-rest reference, but only within defined boundaries. The 40% depth-of-discharge condition represents a stable region of success, 70% exhibits mixed outcomes, and 100% remains the most challenging regime. Descriptor-level analysis reveals that the correction is more effective for centroid- and area-related metrics than for fine peak-height geometry. These findings reinterpret short-relaxation ICA distortion as a protocol-induced contribution that can generate pseudo-evolution in material-related fingerprints. Therefore, accounting for this contribution is essential before using ICA to infer degradation mechanisms from cycler-accessible signals.
700-format cells with a nominal capacity of 4.9 Ah, were aged under a common cycling protocol and characterized using a repeated reference performance test (RPT) template. All measurements used in this work were conducted at 25 °C. A total of 166 complete RPTs were available across the 12 cells; the cell-level aging coverage and diagnostic-condition matrix are provided in Table S1, SI. The central comparison in this work is not a cross-cell aging-trajectory comparison, but a within-RPT relaxation comparison: for each complete RPT, short-rest diagnostic charges are compared with the corresponding 60-min charge from the same cell, the same aging checkpoint, and the same diagnostic condition.
Fig. 1 summarizes the repeated RPT sequence. Each RPT included a capacity measurement, a low-rate C/25 reference charge, four ICA-related diagnostic charges, and current-interrupt tests. The four ICA-related charges form the controlled relaxation set used in this study. Within the same cell and RPT, these charges were conducted at identical diagnostic C-rate and DoD, while only the pre-charge relaxation duration was varied to 60, 30, 10, and 0 minutes. The 60-min case is used as the practical long-rest reference; the 30- and 10-min cases are the main short-rest standardization targets; and the 0-min case is retained primarily to characterize the extreme non-relaxed distortion. The 60-min duration was selected as a practical upper-bound relaxation period in the repeated RPT design: it provides a substantially relaxed diagnostic condition while keeping the total RPT duration compatible with repeated full-lifetime aging characterization. Longer rest periods could further reduce residual non-equilibrium contributions, but would substantially increase the time cost of each repeated diagnostic checkpoint. Therefore, the 60-min case is treated as a practical long-rest condition. Detailed charge-case definitions are provided in Table S2, SI.
To examine the condition dependence of relaxation-induced kinetic masking, the cells covered four diagnostic charge rates, 0.1C, 0.3C, 0.7C, and 1.0C, and three DoD levels, 40, 70, and 100%. Each cell retained one assigned diagnostic C-rate–DoD combination throughout aging. This design provides two levels of information: within each complete RPT, the relaxation-duration effect can be isolated under a fixed cell state and diagnostic condition; across the available C-rate–DoD matrix, the dependence of RSI and standardization response on diagnostic condition can be evaluated. Since each C-rate–DoD combination was represented by one cell, the condition-resolved results are interpreted as structured trends across the available cell-condition matrix rather than as fully replicated factorial effects. The focused comparison in this study remains the within-RPT relaxation-duration comparison. The C/25 charge and current-interrupt measurements were used only as supporting measurements. The C/25 charge provides a low-polarization reference landscape but is not used as the standardization target, because doing so would mix relaxation effects with changes in current, polarization background, and charge path. The current-interrupt tests help contextualize local short-time polarization but are not direct inputs to the voltage-domain standardization framework.
Changing only the pre-charge relaxation duration already produces a systematic difference in the charging–voltage trajectory (Fig. 2b). This voltage-domain difference appears moderate in the U–Q representation, but it becomes more pronounced after differentiation. The corresponding IC curves show peak displacement and intensity changes within the same fingerprint windows (Fig. 2c). This behavior reflects the differential nature of ICA: a protocol-induced voltage shift can be amplified in the dQ/dU domain, especially in voltage regions with plateau-like responses. The observed IC variation should therefore not be treated as a numerical artifact or a smoothing issue; it is the differential expression of a modified voltage projection.
The projection originates from the electrochemical background retained after short relaxation. Residual polarization and concentration imbalance from the previous state remain at the beginning of the subsequent diagnostic charge and continue to evolve during charging.25,26 The resulting distortion is voltage-window-dependent, because ohmic, kinetic, and diffusion-related overpotentials vary with current, the voltage region, and the local electrode state. In graphite-based LIBs, this state dependence is further strengthened by SOC-dependent lithium redistribution and equilibration kinetics.27 The same material state can therefore be projected onto different voltage trajectories depending on the relaxation history.
From a material interpretation perspective, this behavior constitutes relaxation-induced kinetic masking. The material-related fingerprint remains present, but it is observed through an additional non-equilibrium layer introduced by the test protocol. A fingerprint window may shift, change its local center, or redistribute its area because of residual relaxation history. This distinction is essential when ICA descriptors are used to discuss degradation-related chemistry: without accounting for relaxation history, protocol-induced changes may be overassigned to LAM-, LLI-, impedance-, or phase-response-related evolution.
To quantify this effect across the full dataset, we employed a relaxation sensitivity index (RSI), defined in Section S2 of the SI. The global RSI measures the deviation of a short-rest IC curve from the corresponding 60-min reference, whereas the window RSI evaluates this deviation within a predefined fingerprint window. As shown in Fig. 3a, the global distortion decreases with increasing relaxation duration. Across all 166 RPTs, the median global RSI decreases from 7.87% at 0 min to 5.92% at 10 min and 3.62% at 30 min. This monotonic trend indicates that short relaxation introduces a structured protocol-dependent contribution.
Global RSI alone, however, does not fully describe the masking effect. Fig. 3b shows that DoD determines which fingerprint windows are sampled during the diagnostic charge. P4 is covered across all DoD levels, whereas P3 is only partially covered at 40% DoD, P2 is nearly absent at 40% DoD and only partly covered at 70% DoD, and P1 is fully accessible only at 100% DoD. Thus, DoD affects not only the magnitude of the measured distortion, but also the observable part of the fingerprint. Full C-rate × DoD distortion maps for the 30-, 10-, and 0-min cases are provided in Fig. S1, SI.
The local descriptors further show that relaxation-induced masking is not uniformly distributed across the voltage range. Fig. 3c–e summarize representative 10-min window-level results, while the complete window-RSI maps and SOH–correlation analysis are provided in Fig. S2 and S3, SI. In many cases, the distortion appears not as a simple peak-height change, but as a shift in the local response center and a redistribution of the response area within a fingerprint window. For example, P3 at 40% DoD shows a median centroid shift of approximately 7.36 mV and a relative area under the IC curve (AUC) distortion of 8.27%. For P2 at 70% DoD, the corresponding values are approximately 8.98 mV and 12.79%. These descriptors are less dependent on robust single-peak detection and better capture how a local fingerprint is displaced or reweighted by relaxation history.
The dependence on SOH is also condition-specific. The window RSI does not follow a single monotonic trend with aging across all DoD–window combinations, indicating that aging modifies the sensitivity of local voltage regions to insufficient relaxation in a window- and condition-dependent manner. In this study, SOH is therefore treated as a stratifying dimension together with charge rate, DoD, and fingerprint-window location.
Overall, Fig. 2 and 3 establish insufficient pre-charge relaxation as a structured kinetic masking effect in ICA. The masking originates in the voltage trajectory, is amplified in the differential domain, and appears as peak displacement, centroid drift, and area redistribution within material-related fingerprint windows. These findings motivate a voltage-domain standardization strategy: before ICA fingerprints are interpreted as material-related signatures, the short-rest voltage trajectory should first be referenced to the corresponding long-rest condition.
The 60 min relaxation charge is used as the practical long-rest reference for each RPT. This reference is not assumed to represent an ideal equilibrium state;28 rather, it preserves the controlled-variable logic of the experiment by sharing the same diagnostic C-rate and DoD as the short-rest charges. Within the available relaxation-controlled sequence, it is the longest and most relaxed diagnostic charge measured under otherwise identical conditions. It was therefore selected as the internal reference for RSI calculation and voltage-domain standardization. The 30- and 10-min relaxation charges are treated as the primary standardization targets, whereas the 0 min case is retained primarily for distortion characterization. The subsequent evaluation focuses on the P2–P4 fingerprint windows, because P1 is more sensitive to low-voltage boundary effects and incomplete coverage.
The framework is built around τ(U), which is defined here as a compact effective descriptor of the transferable relaxation-induced voltage bias in the voltage domain. This quantity is not interpreted as a unique microscopic time constant of a single electrode process.29 Instead, it is used as a compact descriptor of how the transferable part of the relaxation-induced voltage offset decays across voltage regions.30 This restrained interpretation is important because the terminal voltage of a commercial battery contains overlapping contributions from electrode thermodynamics, charge-transfer kinetics, ohmic resistance, concentration polarization, and lithium redistribution.8 The role of τ(U) is therefore not to separate these processes, but to provide a voltage-domain lens for attenuating the dominant short-rest masking contribution using only cycler-accessible signals.
The construction of τ(U) follows the controlled relaxation design. Within each RPT, charges with different relaxation durations are aligned and compared with the 60-min reference to estimate how the voltage offset depends on relaxation time and voltage region. The resulting fitted τ-function is mapped to the voltage domain so that it can be applied along the measured charging trajectory. To improve cross-cell transferability, the implementation combines a global relaxation function with a C-rate-stratified function through a shrinkage strategy. This retains the observed rate dependence of relaxation-induced masking while reducing overfitting to sparse condition-specific data. Details of charge-progress alignment, τ(U) identification, voltage-domain mapping, cell-level aggregation, and shrinkage are provided in Section S4 of the SI.
For each short-rest charge, the immediately preceding relaxation segment is employed to estimate the residual non-equilibrium contribution retained at the beginning of the diagnostic charge. This contribution is then propagated along the subsequent charging trajectory using τ(U), giving a voltage-domain offset that is subtracted from the measured short-rest voltage. The standardized voltage trajectory is then interpolated onto the common voltage grid, and ICA is recalculated using the same processing workflow as for the raw fingerprints. Low-voltage region gating and amplitude clipping are applied as stabilization constraints to reduce overcorrection near boundary-sensitive regions and to keep the propagated correction within the range supported by the measured relaxation signal; their implementation is described in Section S4 of the SI.
The workflow is summarized in Fig. 4. In this study, the τ(U)-based framework is best viewed as a voltage-domain relaxation lens. It estimates and attenuates the transferable component of the short-rest kinetic masking layer before differentiation, thereby recalculating the IC fingerprint on a more comparable long-rest-referenced voltage background. The model does not claim to recover an equilibrium voltage curve or to identify microscopic relaxation processes. Its purpose is to test whether part of the apparent ICA fingerprint evolution is a removable protocol-induced contribution. The success and failure patterns of this lens are examined in the next section.
Fig. 5 summarizes the baseline standardization results in the P2–P4 fingerprint windows. For each test cell, all model parameters are estimated from the remaining cells using the leave-one-cell-out protocol described in Section S4 of the SI.
Across the target cases, the standardized fingerprints shift toward the positive-gain side (Fig. 5a), indicating that short-rest distortion contains a transferable component. For the 30-min cases, the mean and median reductions in P2–P4 RSI are 0.59% and 0.45%, respectively. For the 10-min cases, the corresponding values are 0.51% and 0.44%. Full statistics, including positive-improvement fractions and Wilcoxon signed–rank test results, are provided in Table S3, SI.
The comparison between 30- and 10 min-relaxation reflects the expected difficulty of the standardization task (Fig. 5b). The 30-min case is closer to the 60-min reference and requires a smaller extrapolation of the residual voltage contribution. The 10-min case starts from a stronger non-equilibrium background, so the propagated correction is larger and less certain. Nevertheless, both subsets show positive median gain, supporting the interpretation that the short-rest bias contains a first-order component that can be transferred across cells.
Within the available cell-condition matrix, the more informative boundary is set by DoD (Fig. 5c and d). At 40% DoD, the baseline lens shows stable improvement, with mean and median P2–P4 RSI reductions of 1.70% and 1.14%, and a positive-improvement fraction of 97.6%. At 70% DoD, the response becomes condition-dependent, with mean and median reductions of 0.48% and 0.74%. At 100% DoD, the limitation becomes clear: the mean gain is negative, the median remains close to zero, and only 24.0% of cases improve. These results define a three-level correctability boundary: 40% DoD is a stable success region, 70% DoD is a mixed region, and 100% DoD is the hardest scenario. DoD-stratified statistics are summarized in Table S4, SI.
This boundary is not only a statistical partition. It reflects the distribution of relaxation-induced masking along the diagnostic charge path. At shallow or moderate DoD, the short-rest bias is sampled over a more limited portion of the voltage trajectory and is more often approximated as a removable voltage-domain contribution. At 100% DoD, however, the diagnostic charge starts from a deeper low-SOC state and spans the full operational voltage range. The preceding deep-discharge preparation can leave a more spatially and electrochemically distributed non-equilibrium background, including steep residual solid-phase concentration gradients, electrolyte concentration imbalance, and local overpotential components that depend on electrode stoichiometry. During the subsequent charge, these contributions do not simply decay as a single voltage-domain offset. Instead, they can be redistributed as the cell traverses different graphite staging regions and positive-electrode response regions. The resulting relaxation memory is therefore path-coupled and multi-timescale: the apparent voltage bias at a given voltage is affected not only by the local value of U, but also by the preceding SOC range and by the evolution of residual concentration gradients along the charge path. This behavior violates the central simplification of the baseline lens: that the dominant short-rest contribution can be treated as a transferable voltage-domain bias whose decay is mainly parameterized by the present voltage. In the deep-DoD case, the observed voltage bias is more likely a superposition of several residual contributions with different spatial origins and relaxation rates, including particle-scale diffusion imbalance, electrolyte redistribution, and state-dependent interfacial polarization. A single τ(U)-based descriptor can therefore attenuate only the transferable first-order component, and cannot fully represent this distributed path memory. Complete condition-resolved maps across diagnostic C-rate and DoD are provided in Fig. S4, SI.
The descriptor-level results clarify what type of fingerprint comparability is restored (Fig. S5, SI). The gain is window-dependent. P2 is the most sensitive window when sufficiently covered, while improvements in P3 and P4 are more concentrated at 40% DoD. The relaxation lens preferentially improves position- and area-related descriptors. For P2 at 70% DoD, the median reduction in centroid-error magnitude is approximately 3.18 mV, and the corresponding reduction in relative AUC error is approximately 3.92%. In contrast, peak-height errors show solely limited improvement. This distinction is central to the interpretation of the framework: the voltage-domain lens primarily reduces protocol-induced displacement and area redistribution, but it does not fully reconstruct the fine-peak-height geometry.
Representative curve-level examples are shown in Fig. 6. In the easy case, the standardized voltage trajectory and recalculated IC fingerprint move closer to the 60 min reference (Fig. 6a and d). In the split case, the voltage-domain correction improves part of the local fingerprint while leaving other regions less affected (Fig. 6b and e). In the hard case, the relevant deviation is not effectively reduced, and the standardized IC curve remains poorly aligned with the reference (Fig. 6c and f). These examples make the correctability boundary visible at the curve level: the relaxation lens is effective when the short-rest distortion behaves as a transferable voltage-domain masking layer, but it fails when path history and accumulated non-equilibrium contributions become too distributed or window-coupled.
![]() | ||
| Fig. 6 Representative curve-level standardization examples. (a–c) Voltage trajectories and (d–f) recalculated IC fingerprints for easy, split, and hard scenarios. | ||
Together, Fig. 5 and 6 indicate that the proposed standardization restores fingerprint comparability in a limited but mechanistically interpretable manner. The success cases demonstrate that part of the apparent short-rest fingerprint evolution is protocol-induced and can be attenuated using cycler-accessible voltage signals. The failure cases are equally informative: they mark regimes where a single τ(U)-based lens is insufficient and where additional state variables, multi-timescale relaxation, or more targeted experimental separation may be required.
The temperature-aware extension remains close to the baseline trend and provides only localized additional benefit. At the subset level, it does not introduce a fundamentally different correction pattern. The clearest improvement appears in the hardest regime. In the 100% DoD cases, the mean P2–P4 RSI reduction increases from −0.82% for the baseline model to −0.38%, and the positive-improvement fraction increases from 24.0% to 34.0%. The strongest incremental gain occurs in the 100% DoD/10 min subset, whereas most other conditions show incremental gains close to zero or slightly negative. Complete statistics and case-wise comparisons are provided in Table S5 and Fig. S6, SI.
These results support a restrained interpretation. Thermal-history coupling may contribute to residual distortion when the charge path is deep, and the relaxation duration is short, but it cannot yet be compressed into a robust, globally beneficial correction term under the present data structure. The baseline τ(U) lens therefore remains the main framework for this study. The temperature-aware extension is interpreted as evidence that the hardest cases involve additional state-history variables beyond the dominant voltage-dependent relaxation component, including thermal history, path history, local state dependence, and multi-timescale relaxation.
This distinction is important because common ICA descriptors are often used as indicators of degradation modes. Peak displacement, local area changes, and peak-intensity variation may be associated with loss of lithium inventory, loss of active material, impedance growth, or changes in electrode utilization.7,34 The present results show that the same types of descriptor changes can also be produced by insufficient relaxation alone. Short relaxation retains residual polarization, concentration imbalance, and path memory from the previous state; during the subsequent diagnostic charge, this retained history is projected onto the terminal voltage and amplified in the differential domain. A fingerprint window may therefore shift, broaden, or redistribute its area even when the underlying material state has not changed.
The value of the τ(U)-based standardization is to attenuate this transferable kinetic masking layer before ICA is recalculated. Its role should not be judged only by the absolute reduction in curve error. More importantly, it reduces protocol-induced displacement, centroid drift, and area redistribution within reproducible fingerprint windows. This explains why centroid- and AUC-related descriptors are more effectively restored than peak-height geometry. The framework therefore provides a more comparable long-rest-referenced voltage background for evaluating whether changes in a local fingerprint window are more likely to reflect material-related evolution or relaxation-history variation.
The correctability boundary also carries mechanistic information. In the deep-DoD scenario, especially at 100% DoD, the diagnostic charge spans a broader voltage range and crosses more fingerprint windows. Because the charge starts from a deeper low-SOC state, the retained relaxation history can include more distributed solid-phase concentration gradients, electrolyte imbalance, and local overpotential components inherited from the preceding discharge or rest sequence. Residual non-equilibrium contributions can then propagate, accumulate, and redistribute along the charge path. Under such conditions, short-rest distortion is less likely to be represented by a single first-order voltage-domain bias. Instead, additional state-history variables may be needed to describe how the residual non-equilibrium state evolves across voltage windows. The localized benefit of the temperature-aware extension further suggests that thermal history may contribute to the hardest cases, but that it is entangled with path history, local state dependence, and multi-timescale relaxation. Thus, failure cases do not simply indicate insufficient fitting; they identify scenarios in which additional state-history variables may need to be considered.
This interpretation also defines what the proposed framework does not claim. The standardized IC curve should not be regarded as a true thermodynamic ground-state fingerprint. It remains a protocol-dependent response measured under practical diagnostic conditions. The standardized curve is closer to the corresponding 60-min long-rest reference and therefore improves the comparability of material-related fingerprints. Similarly, the framework reduces the risk of overassigning relaxation-induced IC changes to LAM-, LLI-, impedance-, or phase-response-related degradation modes, but it does not independently identify real LAM, LLI, or specific structural transformations. Such assignments would require additional electrode-level or materials characterization, such as half-cell reconstruction, differential-voltage analysis with electrode support, operando measurements, or post-mortem characterization.35
The present validation was performed on commercial NMC/graphite batteries, and the τ(U)-based lens should therefore be regarded as a chemistry- and protocol-calibrated framework. In flatter voltage–plateau systems, such as LiFePO4-based cells, relaxation-induced kinetic masking may be even more pronounced in the IC domain, because a small residual voltage bias can be strongly amplified when transformed into dQ/dU. In such systems, a short-rest relaxation history may therefore produce a larger redistribution of peak area for the same magnitude of voltage-domain deviation. Extending the present τ(U) framework to LFP cells may be more challenging, as two-phase plateau behavior can make the residual non-equilibrium state less compressible into a single descriptor. Similar caution applies to cells using Si-containing negative electrodes, where hysteresis and stress-coupled lithiation may introduce additional state variables. Therefore, the proposed framework is expected to remain conceptually useful as a protocol-aware standardization strategy, but τ(U) would need to be re-identified, and its correctability boundary revalidated for each material system and diagnostic protocol.
The mechanistic picture is summarized in Fig. 7. Under short relaxation, residual polarization, concentration imbalance, and path memory create a kinetic masking layer that distorts the voltage trajectory and the resulting ICA fingerprint. At the materials level, this retained non-equilibrium state can be understood as the cell manifestation of incomplete relaxation of concentration and chemical-potential gradients within active-material particles and the electrolyte phase, together with ohmic and interfacial polarization. These microscopic and mesoscopic relaxation processes are not directly observed in the present experiment; instead, they appear as a macroscopic voltage-relaxation signature accessible from the cycler. The voltage-dependent relaxation lens uses this cycler-accessible voltage signature as a physical-time-lens analogy, mapping the residual relaxation history onto an effective voltage-domain correction before recalculating the IC curve. In this sense, τ(U) acts as an effective descriptor of the transferable voltage-domain footprint of residual concentration-gradient relaxation and polarization decay. The standardized response is therefore not an equilibrium material fingerprint, but a long-rest-referenced fingerprint with improved comparability. This provides a protocol-aware route to reduce the interpretation of pseudo-degradation while preserving the material relevance of ICA under realistic diagnostic constraints.
To reduce this masking prior to material-related interpretation, a voltage-domain relaxation lens was developed based on a compact effective descriptor of the transferable relaxation-induced voltage bias in the voltage domain, τ(U). This framework aligns practical short-rest charges with their corresponding long-rest references under identical diagnostic conditions, then recalculates the ICA on a more comparable voltage background. Cross-cell validation demonstrates that this long-rest-referenced standardization improves comparability in the P2–P4 windows, but only within defined boundaries: 40% DoD is a stable success region, 70% DoD is condition-dependent, and 100% DoD represents the primary limit of correctability.
Descriptor-level results clarify the specific aspects restored by this standardization. The τ(U) lens reduces centroid- and AUC-related errors more effectively than peak-height errors, indicating that its primary contribution is attenuation of protocol-induced displacement and area redistribution. This approach decreases the risk of misattributing relaxation-induced pseudo-evolution to LAM, LLI, impedance, or phase-response-related material evolution. However, standardized ICA fingerprints cannot independently identify these irreversible mechanisms and should not substitute for electrode-level or materials characterization. The temperature-aware extension further indicates that thermal history may contribute to the most challenging cases, particularly at 100% DoD and 10 minutes relaxation, but its benefit remains localized and cannot currently be represented as a robust global correction term.
Because the present validation is limited to commercial NMC/graphite batteries, extension to other material systems should be treated as a chemistry- and protocol-specific recalibration problem. Flatter–plateau systems such as LiFePO4 may amplify small residual voltage deviations in the dQ/dU domain, whereas two-phase behavior may introduce additional path-dependent state variables. Future use of the framework should therefore re-identify τ(U) and revalidate the correctability boundary for each cell chemistry and diagnostic protocol.
In summary, the findings demonstrate that the testing protocol must be considered an integral component of measurement when ICA is used for degradation interpretation. Long-rest and short-rest IC curves should not be compared as if they originate from the same electrochemical background. A portion of the observed ICA-fingerprint evolution during practical testing arises from relaxation-induced kinetic masking and can be partially attenuated using only cycler-accessible signals. The remaining failure cases highlight situations where path history, thermal history, and multi-timescale relaxation exceed the corrective capacity of a single τ(U)-based lens. Future research should focus on experimental designs and models that explicitly separate these state-history effects. The present framework establishes a protocol-aware approach for more reliable comparison of material-related ICA fingerprints under realistic diagnostic constraints.
Supplementary information (SI): experimental and diagnostic protocol details, IC processing and descriptor definitions, full relaxation-induced distortion maps, the τ(U)-based voltage-domain standardization procedure, cross-cell validation statistics, representative curve-level cases, and the temperature-aware extension. See DOI: https://doi.org/10.1039/d6ta03434a.