Correction: Synthesis of anisotropic colloids with concave and convex structures

Longfei Luo, Chengcheng Liang, Hong Zhang, Yiwu Zong* and Kun Zhao
Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China. E-mail: yiwuzong@tju.edu.cn

Received 5th February 2026 , Accepted 5th February 2026

First published on 25th February 2026


Abstract

Correction for ‘Synthesis of anisotropic colloids with concave and convex structures’ by Longfei Luo et al., Soft Matter, 2021, 17, 10696–10702, https://doi.org/10.1039/D1SM01463C.


The authors regret that there was an error in the sentence in lines 41–51 in the left column on page 10697 of the original article. The text originally read: “For the seeds used in the experiments to check the priority of the polymerization reaction on different sites (Section 3.2.2), a premixed solution containing styrene (3.0 g), ethanol (30 mL) and DVB (200 µL) was injected into the flask in a slightly different feeding mode. The premixed solution was injected first at 90.5 µL min−1 for 66 minutes, then the injection was stopped. At 2 h after the first injection started, a second injection with a rate of 400 µL min−1 was started and lasted for 40 minutes before it was stopped. Then at 4 h after the first injection started, a final injection with a rate of 90.5 µL min−1 began and lasted for another 66 minutes.”

This sentence should read: “For the seeds used in the experiments to check the priority of the polymerization reaction on different sites (Section 3.2.2), a premixed solution containing styrene (4.0 g), ethanol (40 mL) and DVB (200 µL) was injected into the flask in a slightly different feeding mode. The premixed solution was injected first at 90.5 µL min−1 for 66 minutes, then the injection was stopped. At 2 h after the first injection started, a second injection with a rate of 400 µL min−1 was started and lasted for 30 minutes before it was stopped. Then at 4 h after the first injection started, a final injection with a rate of 700 µL min−1 began and lasted for another 30 minutes.”

Additionally, in the sentence in lines 10–12 in the right column on page 10697 of the original article, the text originally read: “Next, the mixture was transferred to a three-necked flask and 2.5 wt% AIBN and 0.18 wt% hydroquinone (based on the mass of styrene) were added.”

This sentence should read: “Next, the mixture was transferred to a three-necked flask and 2.5 wt% AIBN and 0.9 wt% hydroquinone (based on the mass of styrene) were added.”

The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.


This journal is © The Royal Society of Chemistry 2026