Open Access Article
Alessio Polvani
abc,
Amedeo Boldriniab,
Riccardo Gaetano Cirrone
ce,
Xinyu Liuab,
Luisa Galgani
abc,
Fiona Regan
f,
Abu Bakar Kamarag,
Mohamed Sahr E Juanahg and
Steven A. Loiselle
*abd
aDepartment of Biotechnology, Chemistry and Pharmacy, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy. E-mail: loiselle@unisi.it
bCenters for Colloid and Surface Science, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy
cNational Biodiversity Future Center, Spoke 3, University of Siena, Via Banchi di Sotto 55, 53100 Siena, Italy
dEarthwatch Europe, 102-104 St Aldate’s, Oxford OX1 1BT, UK
eDepartment of Earth and Marine Sciences, University of Palermo, Via Archirafi 22, 90123 Palermo, Italy
fDCU Water Institute and School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, D09 V209, Ireland
gNational Water Resources Management Agency (NWRMA), 29 King Harman Road, Freetown, Sierra Leone
First published on 7th January 2026
Heavy metal (HM) pollution continues to threaten freshwater ecosystems worldwide, disproportionately impacting low-resource communities where routine analytical monitoring is often absent. Despite advances in spectroscopy, electrochemical platforms, and automated sensing networks, regular monitoring of potential pollution events by local agencies remains constrained by high costs, specialised equipment, and the need for trained personnel. As a result, contamination events are frequently detected late—after ecological or public health damage has already occurred. Colourimetric sensing offers a complementary pathway toward decentralised early-warning systems. These sensors translate chemical information into visually interpretable colour changes, enabling rapid, inexpensive screening without laboratory infrastructure. In recent years, the field has seen a rise in bio-based membrane formats—cellulose, biopolymers, protein-derived films, and hybrid natural–synthetic composites—motivated by their sustainability, safety, and tunability. Yet their future impact will depend not only on analytical metrics but also on how well they fit into real-world monitoring ecosystems. This Perspective argues that the next decade of progress should be guided not solely by material innovation and continuously lower detection limits, but by a stronger focus on practical deployability, community integration, and environmental responsibility.
HMs represent one of the most persistent and damaging classes of contaminants, with long-term ecological and human health consequences.1–3 Their prevalence in the Global South is strongly tied to artisanal and small-scale mining (ASM)—a sector that, despite repeated formalisation efforts, continues to operate with minimal oversight. In many regions of Africa, Asia, and South America, artisanal gold mining is still the primary source of mercury entering freshwater systems.4–6 Numerous studies have linked elevated HM concentrations in downstream waters and sediments to these unregulated practices.7–10 Yet monitoring remains limited as those countries most affected by ASM-related pollution often lack the institutional capacity, funding, and infrastructure required for routine surveillance.11
The consequence is that communities are left unaware of the quality of the water they drink, cook with, and bathe in. Chronic and episodic contamination events go undetected.12,13 Without timely information, neither communities nor local agencies can act. From a public health perspective, this represents a preventable exposure crisis. From a monitoring standpoint, it is a systemic failure.
This is precisely where accessible, decentralised sensing technologies could shift the paradigm. Colourimetric sensors—often dismissed as “low-tech”—are, in fact, uniquely positioned to fill the monitoring gaps that high-end instruments cannot. They are low-cost, portable, intuitive, and fast.14,15 More importantly, they can be embedded into community-led monitoring ecosystems, enabling real-time identification of water quality changes without dependence on distant laboratories.16,17
However, not every colourimetric system is appropriate for decentralised use. If these technologies are to have real-world impact, they must satisfy the ASSURED criteria (affordable, sensitive, specific, user-friendly, rapid/robust, equipment-free, deliverable), originally defined by the WHO, but arguably more relevant today for environmental sensing than they ever were for medical diagnostics. The environmental monitoring community has not sufficiently embraced this framework. ASSURED-compliant tools align naturally with participatory monitoring and citizen science, which have already demonstrated their value in increasing data coverage, empowering users, and contributing to SDG tracking.16,18,19
Within colourimetric technologies, solid-supported formats stand out as the most suitable for community deployment. They minimise reagent handling, improve stability, and reduce the risk of user error. Emerging research, such as Silva et al. (2022), underscores growing interest in accessible sensor formats for in situ monitoring,20 while analogous work on emerging contaminants (e.g., PFAS) highlights the universal need for low-barrier analytical tools.21 Among solid supports, bio-based membranes represent one of the most promising yet under-evaluated platforms. They offer multiple functional advantages—immobilisation of chromophores, analyte pre-concentration, enhanced selectivity—and they do so use sustainable, low-cost materials.22,23 Properly immobilised dyes are more stable, less prone to leaching, and better positioned to generate reliable colour transitions even in challenging environments.24 Yet despite these advantages, the field lacks a clear comparative framework for assessing which membrane systems are genuinely fit for purpose.
This Perspective argues that such an evaluation is overdue. The literature has grown rapidly, but it remains fragmented, and the most crucial question—which bio-based colourimetric sensors can actually support community-level heavy metal monitoring? —has not been systematically addressed. Here, we provide the first comparative assessment of bio-derived membrane-based colourimetric sensors and offer a critical viewpoint on their strengths, limitations, and what the field must prioritise to translate laboratory prototypes into meaningful tools for environmental justice.
| Metals/compounds | CAS number | AA-EQS(1) (ppb) inland surface waters (WFD) | MAC-EQS(2) (ppb) inland surface waters (WFD) | WHO drinking water guideline values (ppb) |
|---|---|---|---|---|
| a Concentration limits depend on water hardness | ||||
| Cadmium and its compounds | 7440-43-9 | 0.08–0.25a | 0.45–1.5a | 3 |
| Lead and its compounds | 7439-92-1 | 7.2 | Not reported | 10 |
| Mercury and its compounds | 7439-97-6 | 0.03 | 0.06 | 5 |
| Nickel and its compounds | 7440-02-0 | 20 | Not reported | 70 |
Selectivity remains a persistent weak point. Natural waters contain an abundance of potentially interfering ions, many of which can trigger false positives or alter the intensity of colour transitions. Yet in much of the literature, interference testing is superficial at best, often limited to a handful of ions at unrealistic concentrations. Tailored ligands, metal-selective chelators, or nanoparticle surface modifications offer partial solutions,27–29 but the field has yet to develop a standardised framework to rigorously evaluate selectivity across physiochemical regimes. Until it does, claims of “high specificity” should be treated with caution.
For adoption in low-resource settings, colourimetric sensors must be truly intuitive, safe to handle, and operable without specialised equipment. This requirement is not optional; it is fundamental to closing data gaps in environmental monitoring.30 Smartphone-based platforms such as those demonstrated by Li et al. (2023) show promise,31 but their dependency on consistent lighting, camera quality, and app calibration complicates deployment by non-experts.
Response time is another critical issue. In early-warning contexts, minutes matter. While many sensors claim rapid responses, these metrics rarely account for the realities of field deployment in tropical climates, complex transport times, and poor storage conditions. Studies such as Ateia et al. (2024) highlight the urgent need for robust approaches and extended shelf life,32 yet only a minority of current systems demonstrate meaningful durability. Solid reagents and encapsulation approaches can improve robustness33,34 but these techniques are still under-adopted in membrane-based colourimetric platforms.
Environmental variability further complicates sensor performance. Sensors must contend with turbidity, natural water colour, dissolved organic matter (chromophoric dissolved organic matter), and high background iron common in mining-impacted rivers, which can alter colourimetric responses and reduce sensitivity.31–34 Fluctuations in temperature and sunlight exposure during storage can further challenge robustness.33,34 Inconsistent lighting for visual readouts can compromise reproducibility.17 Successful community monitoring requires sensors that are resilient to complex environmental matrices, simple to use, and compatible with non-specialist deployment. Smartphone-integrated platforms, as demonstrated in other citizen science programs, can partially mitigate these challenges by standardizing colour interpretation and enabling immediate data capture.16,31 Real-world programs, including freshwater watch, show that citizen scientists can collect reliable, spatially and temporally dense datasets when sensors are designed with these constraints in mind.18 Incorporating these considerations into membrane-based HM sensor development will be critical for translating laboratory prototypes into deployable tools for early-warning, community-based monitoring.
Polymer blending attempts to overcome some of these weaknesses. By combining biopolymers with more robust materials, blends such as pectin/PVA membranes show improved mechanical stability, but at the cost of higher fabrication complexity and reduced biodegradability.40,41 Electrospinning, while powerful, suffers from similar contradictions: nanofibre mats provide unparalleled surface area and tunable porosity,42,43 yet electrospinning equipment remains expensive and technically demanding, challenging the very notion of “low-cost sensors”.
These trade-offs underscore a central point: no membrane fabrication method is universally optimal, and material choice should be guided by realistic deployment constraints and addressed explicitly in development perspectives.
Natural dyes offer compelling sustainability benefits but seldom match the robustness of synthetic counterparts. Curcumin's affinity for Fe2+/Fe3+ and its Lewis acid–base coordination behaviour make it attractive, yet its stability is limited.51–53 Anthocyanins, sourced from plant materials, provide striking pH-sensitive colour transitions in relation to their flavylium ring, responsible for their colour-changing properties.54,55 However, they are notoriously susceptible to photodegradation and require careful immobilisation.
Ultimately, there is no universal chromophore “best choice”. The most appropriate chromophore depends on the target metal, environmental conditions, required lifetime, and safety constraints—factors often underreported in sensor publications.
Chemical immobilisation provides superior robustness through covalent attachment, typically using crosslinkers such as glutaraldehyde or carbodiimides.59 However, these agents raise toxicity concerns and require controlled reaction conditions. “Green” crosslinkers like genipin and citric acid represent a promising alternative, though their uptake remains minimal.60,61 The demonstrated improvements in durability for glutaraldehyde-fixed dithizone systems make clear that chemical immobilisation is the more reliable route for long-term use.46,62
Current studies should treat immobilisation as a major experimental focus as, from a practical deployment perspective, it is one of the most decisive factors determining whether a sensor can be used outside the laboratory.
| Biopolymer-based membrane | Chromophore | Target HM ion | Lowest detected concentration (ppb) | Colour change | Ref. |
|---|---|---|---|---|---|
| Cellulose/PAN composite films | PAN | Zn2+ | 100 | Scarlet to lighter red | 39 |
| Cellulose acetate/chitosan | Dithizone | Cu2+ | 200 | Blue-green to brown | 46 |
| Zn2+ | 2000 | Blue-green to red-violet | |||
| Hg2+ | 100 | Blue-green to copper | |||
| Pb2+ | 100 | Blue-green to pink | |||
| PAR | Pb2+ | 3000 | Yellow to pinkish yellow | ||
| Cellulose | VBB | Cd2+ | 10 | Yellow to blue-green | 50 |
| Polyamide-6/nitrocellulose nanofiber/nanonet membrane | Anthocyanin (red cabbage) | Fe3+ | 1000 | Light pink to dark pink | 55 |
| Cellulose acetate | Dithizone | Hg2+ | 3000 | Green to orange | 57 |
| Cellulose acetate/chitosan | Dithizone | Hg2+ | 1000 | Red to pink | 62 |
| Cu2+ | Red to yellow | ||||
| Zn2+ | Red to white | ||||
| Cotton thread modified with a chitosan membrane | PAR | Co3+ | 6.5 | Yellow to red-purple | 63 |
| Cellulose filter paper | Zincon | Ni2+ | 6 | Blue to pink/grey | 64 |
| Cellulose acetate nanofibers | Curcumin | Pb2+ | 4000 | Yellow to orange | 65 |
| Carboxymethyl tamarind gum/polyacrylamide hydrogel matrix | m-BPDM | Hg2+ | 500 | Pinkish red to dark blue | 66 |
| Zn2+ | 1000 | ||||
| Cd2+ | 2000 | ||||
| Chitosan fibers functionalized with porphyrin | TCPP | Hg2+ | 2000 | Brown to yellow-green | 67 |
| Cellulose paper strips impregnated with chitosan nanoparticles | Cyanidin (red cabbage) | Fe3+ | 10 000 |
White to pink | 68 |
| Cellulose | Lysine-bis-Schiff base | Hg2+ | 10 | White to yellow | 69 |
| Curcumin-loaded zein nanofibers | Curcumin | Fe2+ | 400 | Yellow to brown | 70 |
| Starch-amylopectin-polyvinyl alcohol film | Anthocyanin (black rice) | Cu2+ | 1390 | Red to green | 71 |
| Polyaspartic acid electrospun nanofiber hydrogel | PASP | Cu2+ | 300 | White to blue | 72 |
| Fe3+ | 100 | White to yellow | |||
| Bovine serum albumin gold nanoparticles | BSA-Au NPs | Pb2+ | 41 | Pink to clear pink | 73 |
To strengthen transparency, we applied a quantitative rationale to the comparative framework. Thresholds for colour-coded scoring were defined based on internationally recognised standards for heavy metal limits in freshwater (e.g., WHO, EPA) and operational requirements for field monitoring. For sensitivity, “green” was assigned to sensors achieving LODs in the low-ppb range because these values fall below or within the regulatory limits for key metals such as Pb, Cd, and Hg, ensuring that early-warning detection is feasible. “Yellow” corresponds to upper-ppb values that may detect pollution events but would miss sub-acute contamination, while ppm-level LODs were deemed “orange” because they cannot detect environmentally relevant concentrations. A <10 min response-time threshold was used to reflect the operational need for near-real-time decision-making in community-based monitoring, with the trained citizen scientists performing measurements in the field. Sensors requiring >1 h make monitoring for rapid screening less effective. Working pH ranges were benchmarked against the typical range for river environments (pH 6–8), to distinguish between broadly deployable sensors (green) and those requiring narrow or less realistic conditions (orange). Stability categories were set based on realistic storage expectations for low-resource settings where refrigeration is rarely available; only sensors maintaining >40 days of stability at room temperature were considered operationally “mature” (SI S1).
To ensure comparability across heterogeneous studies, we weighted each criterion equally. This choice reflects the absence of consensus regarding which performance dimension is most important for deployment—sensitivity, selectivity, material sustainability, and stability all represent distinct constraints on real-world applicability. Unequal weighting would have risked imposing subjective priorities that do not apply across deployment contexts. Laboratory-only performance metrics were normalised against environmental applicability by explicitly separating “analytical performance” (sensitivity, selectivity) from “applicability” (pH range, response time, stability) and “safety/environmental impact” (chromophore toxicity, membrane biodegradability, immobilisation chemistry). This allowed a sensor to score highly in controlled analytical conditions while still being penalised for instability or narrow operational conditions. By making these quantitative and context-based thresholds explicit, our comparative analysis remains reproducible while we acknowledge that any framework necessarily simplifies a diverse methodological landscape. Nonetheless, this structured approach enables clearer identification of technologies with genuine translational potential for community-based heavy-metal monitoring. Furthermore, these criteria expose the essential trade-off that needs to be acknowledged: the best-performing sensors analytically are not always the safest or most practical, and the most sustainable designs often underperform analytically. This trade-off is the central bottleneck for translating research into practical application.
A dominant weakness across the literature is the use of laboratory-prepared ion solutions to assess selectivity. This practice continues despite the potential for a range of interferents in typically complex natural waters. A sensor that “selectively detects Pb2+” in ultrapure water may behave very differently in water containing natural dissolved organic matter (e.g. humic matter), variable ionic strength, or competing cations at environmentally relevant ratios. Only a minority of studies (e.g., Azmi et al. (2017), Li et al. (2017), Zhang et al. (2021)) tested using field obtained freshwater samples, and even these rarely examined seasonal or geochemical variability.62,64,69
Selectivity challenges were common but often under-acknowledged. For example, El-Naggar et al. (2021) and Khattab et al. (2022) observed strong interference from Al3+ and Cu2+ when targeting Fe3+, while Suarez et al. (2020) mitigated Fe3+ interference only through chemical masking, raising questions about field practicality.55,63,68 These are not minor issues: many of the interferents reported are ubiquitous in ecosystems where mining activities occur.
Finally, few studies addressed the impact of natural organic matter or salinity, despite their ubiquitous presence in riverine, estuarine, and tropical systems. Dissolved organic matter can potentially mask colour changes or, more importantly, compete for binding, yet its effect remains largely unquantified. Salinity is almost entirely ignored, limiting the use of these methods in estuarine or saline intrusion areas.
Response time. Only seven studies achieved rapid responses (<10 min), with a few reporting exceptionally fast sensing (5 seconds in Ma et al. 2024; Khattab et al. 2022; El-Naggar et al. 2021).55,67,68 Several sensors require hours to reach stable signals. Other studies provided no response time data, making it impossible to explore their use with real-world monitoring, where users need timely interpretation, not laboratory-style incubations.
Working pH range. Most freshwater environments range between pH 6–8, while many sensors were shown to operate in narrow or unrealistic pH conditions. Several studies require pH < 3 (e.g., Saithongdee et al. 2014), rendering them unsuitable for direct field use.70 Others fail to report pH tolerance entirely, which is a critical information gap, given that pH shifts can alter both chromophore ionisation and membrane integrity.
Stability and storage. Long-term stability is arguably one of the most important parameters for community-based monitoring in remote areas, yet it is only rarely reported. Sensors with meaningful stability were reported to be 40 days at room temperature (Zhang et al. 2021), 60–90 days under dry conditions (Low et al. 2022; Azmi et al. 2017).46,62,69 Several methods reported requirements of controlled-light or controlled-temperature storage, while others simply provided no stability assessment at all.
Affordability and scalability. Cost pathways are conspicuously absent from reporting despite being a decisive factor for adoption in low-resource settings. Material costs range from negligible (cotton linters, recycled cellulose) to prohibitive (electrospun nanofibers requiring specialized equipment). For instance, Suarez et al., 2020 outlined that their chitosan-modifeid cotton threads systems costs less than 0.01€ per device.63 Chromophore expenses vary similarly: commercial dyes like PAN are widely available and inexpensive, while custom-synthesized ligands may cost orders of magnitude more. Fabrication requirements further impact scalability. None of the reviewed studies provided cost-per-test estimates or manufacturing cost breakdowns, which made it impossible to compare economic viability.
If colourimetric membrane sensors are to have any community-level impact, stability, operability, scalability and flexibility must be viewed as primary design goals, not accessories.
Chromophores: performance vs. eco-friendliness. Natural chromophores (anthocyanins, curcumin) appear attractive from a sustainability standpoint but consistently fail to reach useful LoDs. Conversely, widely used synthetic dyes (PAN, TAN, dithizone) provide excellent performance but can introduce toxicity or persistence concerns. The exception is 4-(2-pyridylazo) resorcinol (PAR), a widely used chromophore that forms coloured chelates with metal ions and is used in both UV-vis and titration methods. PAR combines good performance with relatively low toxicity but remains surprisingly underused relative to alternatives.
Membranes: bio-based vs. biodegradable. Some membranes are fully biopolymeric (cellulose acetate, chitosan, zein), yet many “bio-based” sensors incorporate synthetic co-polymers or stabilisers that reduce biodegradability. Membranes composed entirely of biodegradable and eco-friendly materials would be most appropriate. For example, Raj & Shankran (2016) used curcumin-loaded cellulose acetate nanofibers, while Azmi et al. (2017) utilized a cellulose acetate/chitosan blend membrane.62,65 Saithongdee et al. (2014) employed electrospun curcumin-loaded zein nanofibers derived from maize.70 Other membranes used a combination of bio-based and synthetic materials, which strengthened membrane properties but reducing their biodegradable potential. This reflects a common design paradox: improving mechanical robustness often makes the material less sustainable.
Immobilisation: robustness vs. environmentally safety. Chemical immobilisation frequently relies on aldehydes, carbodiimides, or other reactive crosslinkers. While robust, these approaches often introduce toxic reagents. For instance, Ma et al. (2024) employed carbodiimide hydrochloride and N-hydroxysuccinimide to graft a porphyrin-based chromophore onto a chitosan structure.67 Yadav et al. (2025) used m-BPDM as a cross-linking agent, while Zhang et al. (2019) immobilised PASP through hydrolysis and cross-linking of poly(succinimide).66,72 These techniques, while effective, raise concerns about environmental and user safety. Only a few studies explored greener alternatives (e.g., genipin, citric acid). Physical immobilisation methods, which generally require fewer toxic reagents, provide an eco-friendly alternative but result in less stable interactions between the chromophore and the membrane. Zhang et al. (2020) immobilised a chromophore onto regenerated cellulose films via a physical soaking process in an ethanol-dye solution, forming dye/cellulose composite films.39 Low et al. (2022) avoided toxic reagents by using a membrane-dipping technique to immobilise dithizone.46 Physical immobilisation methods align better with the principles of green chemistry but remain vulnerable to dye leaching. Robust immobilisation without toxic reagents is currently an unsolved challenge, yet it is crucial for sensors intended for widespread field use and environmentally safe disposal.
A central finding of this perspective is that current research overwhelmingly optimises some key aspects while overlooking others. Sensors that achieve outstanding ppb-level detection limits often rely on synthetic chromophores, toxic cross-linkers, or narrow working pH windows that limit real-world applicability. Conversely, sensors using eco-compatible materials, natural dyes, and physical immobilisation methods demonstrate improved sustainability but frequently suffer from poor stability, suboptimal LoDs, and limited selectivity. This persistent trade-off between performance and eco-friendliness is the core barrier preventing translation from laboratory to actual real-world applications.
Our analysis also highlights an important information gap, typically ignored in the literature: cost. Only one of the studies reviewed provide costed pathways for manufacturing, distribution, or maintenance. This omission is particularly problematic because sensors are most urgently needed in regions where financial constraints dictate the feasibility of adoption. Without cost transparency, even technically promising sensors risk becoming academic artefacts rather than usable technologies.
Despite this, several studies demonstrate the potential for colourimetric membrane sensors to achieve measurement accuracy, with detection limits suitable for early-warning applications. Sensors with fast response times, broad pH operability, and long-term dry storage stability represent credible candidates for community-based monitoring programmes. However, these strengths remain uneven across the literature, and real-water validation remains the exception rather than the norm. The path from promising prototypes to globally deployable tools is best understood through the lens of the ASSURED framework. Colourimetric membrane sensors inherently satisfy some of these criteria: they are equipment-free, visually interpretable, and potentially low-cost at scale. Yet our comparative analysis shows that full ASSURED compliance remains elusive. Affordability and user-friendliness remain unknown due to unquantified production costs; sensitivity and specificity are often not tested outside controlled laboratory conditions; robustness is undermined by limited shelf-life and vulnerability to pH, turbidity, and temperature swings; and deliverability is constrained by chemical immobilisation and non-biodegradable substrates. Embedding the ASSURED criteria directly into the design and evaluation of next-generation sensors would therefore shift the field away from narrow optimisation toward solutions genuinely usable by communities and water authorities in low-resource, mining-affected regions.
To move beyond incremental advances, the field must redefine what constitutes “performance”. Deployability, robustness, environmental safety, and affordability must be treated as primary design criteria, not secondary considerations to sensitivity. Real progress will only occur when sensors are tested in complex natural waters that reflect characteristic of tropical and mining-impacted systems, where dissolved organic matter, salinity, turbidity, and competing ions routinely challenge sensor reliability. We identified three priorities that will determine whether colourimetric membrane sensors remain promising prototypes or become reliable tools for community-based water monitoring:
1. Validation in real freshwater environments, including field trials in diverse and challenging environments where sensors must perform without idealised laboratory conditions.
2. Integration of bio-based materials to enhance sustainability, reduce toxicity, and support safe end-of-life disposal.
3. Development of green, non-toxic immobilisation chemistries that provide stability without relying on hazardous cross-linkers.
Progress along these axes will strengthen sensor maturity, improve readiness for deployment, and support the creation of low-cost, user-friendly early-warning systems. If these challenges are met, colourimetric membrane sensors could play a decisive role in democratising water quality monitoring and empowering communities to detect, mitigate, and prevent heavy-metal pollution in vulnerable freshwater environments.
| HM | Heavy metal |
| LoD | Limit of detection |
| PVA | Polyvinyl alcohol |
| PAN | 1-(2-pyridylazo)-2-naphthol |
| TAN | 1-(2-thiazolylazo)-2-naphthol |
| PAR | 4-(2-pyridylazo)-resorcinol) |
| VBB | Victoria Blue B |
| m-BPDM | N,N′-methylenebisacrylamide |
| TCPP | Tetrakis(4-carboxyphenyl)porphyrin |
| PASP | Poly(aspartic acid) |
| BSA-Au NPs | Bovine serum albumin gold nanoparticles |
Supplementary information (SI) is available. See DOI: https://doi.org/10.1039/d5sd00172b.
Our thanks go to the cooperation partners of the CS4rivers, EU Otters projects and the World Water Quality Alliance. We also thank the collaboration with the DCU Water Institute team from Dublin City University and the scientists in the freshwater team at Earthwatch Europe.
| This journal is © The Royal Society of Chemistry 2026 |