DOI:
10.1039/D6NJ00535G
(Paper)
New J. Chem., 2026, Advance Article
Tuning metal–ligand crosslinking for shape-stable, self-healing capacitive pressure sensors
Received
10th February 2026
, Accepted 20th May 2026
First published on 21st May 2026
Abstract
Self-healing polymers inspired by biological tissue regeneration pave the way for developing robust, flexible wearable electronic devices. In this work, we report a self-healing capacitive pressure sensor composed of an imine- and metal–ligand crosslinked polymer as the dielectric layer, integrated with carbon nanotube (CNT) electrodes. Through fine-tuning of the dynamic crosslinking ratios, a clear structure–property relationship was established, yielding a dielectric with improved geometric stability, mechanical rigidity, and efficient autonomous self-healing. The fabricated sensor demonstrated stable performance under pressures ranging from 60 kPa to 1 MPa, with minimal hysteresis, high cyclic durability, and good fatigue resistance. The crack width and healing time were quantitatively analysed, and the device showed stable operation after consecutive cut-and-healing cycles, while the CNT electrodes retained conductivity with only minor resistance drift. The optimized material was subsequently incorporated into Mesoamerican pyramidal (MAP) microstructured devices to enhance pressure-sensing performance. This work highlights a scalable, intrinsically self-healing pressure sensor with potential for long-term use in wearable electronics, biomedical devices, and harsh industrial environments.
Introduction
The remarkable ability of human skin to rejuvenate and repair itself is inspiring scientists worldwide to design artificial tissue-like materials that incorporate dynamic covalent bonds and supramolecular interactions capable of autonomous healing.1–3 Self-healing is a particularly fascinating phenomenon because it enables materials to recover functionality after damage, opening the door to devices that are safer, longer lasting, and far more resilient than conventional systems.4,5 These properties are especially promising for applications where mechanical flexibility and durability are critical, including wearable electronics, soft robotics, and biomedical device engineering.6–8 Such polymeric materials with self-healing capabilities could ultimately play a vital role in enabling devices that can autonomously repair damage and sustain prolonged use.9–11 Self-healing materials can be categorized by various characteristics. For instance, self-healing can be intrinsic when it relies on reversible interactions such as hydrogen bonding and metal–ligand coordination to repair damage without external input, or extrinsic, when the materials need healing agents or triggers such as heat or light to achieve healability.12 Furthermore, these systems can also be further described as autonomous or non-autonomous depending on whether external stimulation is necessary.13 Over the years, researchers have explored a wide range of self-healing mechanisms and material architectures. In extrinsic systems, mechanical damage ruptures embedded microcapsules or vascular networks, releasing healing agents that initiate repair.14 Although effective, these systems typically depend on external stimuli and often offer only one-time healing, limiting their long-term applicability.5,15,16 In contrast, intrinsic systems often incorporate reversible interactions directly within the materials matrix, such as hydrogen bonding and metal–ligand coordination, allowing repeated healing cycles without external intervention.17–21 These materials provide high durability and re-processability, making them particularly suitable for flexible electronic devices that inevitably experience mechanical stress.22–24
Recent progress in self-healing polymers has enabled materials with enhanced functionality across multiple fields. Self-healing behaviour has been incorporated into flexible sensors,25–28 pressure and force sensors,29–35 organic field-effect transistors,36–39 dielectric materials40 and stretchable conductors,41–46 where mechanical damage would otherwise compromise electrical performance. For example, self-healing e-skins and tactile sensors can maintain mechanical integrity and stable signals after repeated deformation, supporting their use in (bio)signal monitoring and human–machine interfaces.47–50 Beyond wearable and biomedical systems, self-healing materials are also being explored in industrial and aerospace environments, where they can mitigate mechanical, chemical, and thermal degradation.51,52
Among the various self-healing mechanisms, metal–ligand coordination has emerged as a particularly effective strategy for designing soft, functional materials with tunable mechanical and dynamic properties.53,54 By controlling the density and geometry of coordination bonds within a polymer network, the viscoelastic response can be precisely adjusted to balance efficient healing with sufficient rigidity and structural stability.47,55–57 Within the broad landscape of self-healable polymeric systems, our group has developed a platform based on an aminopropyl-terminated oligosiloxane that, upon reaction with 2-pyridinecarboxaldehyde, yields an N-ligand-terminated prepolymer. Subsequent coordination with selected divalent metal cations (M2+) produces dynamically crosslinked networks with tailorable properties.58,59 Systematic investigation of this material family revealed high stretchability, efficient self-healing behavior, and straightforward fine-tuning of thermomechanical properties through judicious choice of the metal crosslinker.58 In recent years, we have extended this class of materials toward practical applications, including microfluidic components and plastic-based capacitive sensors.59,60 Despite their promising material-level performance, metal–ligand coordinated self-healing polymers remain relatively underexplored for bulk sensing applications. To date, most demonstrations have focused on thin-film or low-pressure sensing configurations, with comparatively few studies addressing shape stability or high-load pressure sensing. This limited adoption largely stems from the intrinsically soft and viscoelastic nature of these materials, which can compromise shape retention and dimensional stability under sustained or repeated mechanical loading. As a result, deformation-induced drift and structural relaxation may lead to inconsistent sensor outputs, posing a significant barrier to their implementation in robust, bulk sensing platforms.
In this work, we addressed these limitations by systematically correlating metal–ligand crosslinking density with geometric stability, self-healing efficiency, and device-level pressure-sensing performance. This structure–property framework enabled the identification of an optimal crosslinking regime that balanced structural rigidity with dynamic bond exchange, yielding shape-stable dielectric networks suitable for capacitive pressure sensing. The optimized self-healing dielectric was subsequently integrated between carbon nanotube (CNT) electrodes to fabricate capacitive sensors capable of repeated cut–heal cycles and reliable operation across a broad pressure range of 60 kPa to approximately 1 MPa. Device-level characterization before damage and after autonomous healing confirmed both mechanical resilience and electrical stability. The sensors retained over 90% of their original performance following damage and repair, with pressure sensitivity reaching 64.1 kPa−1 prior to cutting and remaining at 47.8 kPa−1 after healing. Collectively, these results established a direct link between molecular network design and device functionality, demonstrating a practical pathway for translating soft self-healing polymers into shape-stable, microstructured capacitive pressure sensors capable of durable operation.
Experimental methods
Materials preparation
The prepolymer used to obtain the self-healing dielectric materials was prepared following previously reported procedures.58 Briefly, a 500 ml round bottom flask, equipped with a stir bar, was first purged with nitrogen gas. Subsequently, aminopropyl-terminated siloxane (50 g, 0.01 mmol) and pyridine-2-carboxaldehyde (3.2 g, 0.03 mmol) were added and dissolved in chloroform (20 mL). The solution was stirred for 48 hours at room temperature. Subsequently, the solvent was removed under reduced pressure, resulting in the formation of a gel. The gel was dissolved in hexanes and subjected to three extractions using a mixture of hexane and acetonitrile. The hexane fraction was collected and dried under vacuum, resulting in the formation of a prepolymer as a waxy solid. The molecular weight was determined via DOSY-NMR and found to be MW = 5480 g mol−1. The molecular weight was also measured by high-temperature GPC in 1,2,4-trichlorobenzene (180 °C) and found to be MW = 5994 g mol−1. To crosslink the prepolymer and access the self-healing materials, cobalt(II) tetrafluoroborate hexahydrate (Co(BF4)2·6H2O) was used at a 1
:
1 molar ratio with the pre-polymer, following previously reported procedures.58
Polymer crosslinking and molding
The resulting crosslinked polymer was drop-cast into a PTFE mold and degassed in a vacuum chamber for 2 hours to eliminate trapped air and volatile residues. This step was repeated in layers until the desired film thickness for sensor fabrication was achieved. The mold was then left to dry at room temperature for 3 hours before carefully demolding the self-healing elastomeric film. Similarly, the polymer was cast onto an inverse molding of a PDMS-MAP-Ecoflex mold to fabricate MAP like microstructures following previously reported procedures.61 MAP micropatterns with a height of 1250 µm, a top length of 850 µm, a base length of 2100 µm, and an inter-structural spacing of 400 µm were employed.
Device fabrication
The demoulded crosslinked polymer film, serving as the dielectric layer, was subsequently coated with conductive carbon nanotube (CNT) electrodes on both sides to fabricate a capacitive pressure sensor. CNT dispersion was prepared following a previously reported procedure and spray-coated uniformly onto the polymer surface (both sides) using a precision airbrush system under ambient conditions.62 The coated films were then dried at room temperature for 1 hour to remove residual solvent and stabilize the electrode layers. The fabrication sequence of the self-healing capacitive pressure sensor consisting of a CNT–polymer–CNT structure based on the metal–ligand crosslinked dielectric is ready for electrical and mechanical characterization, as shown in Fig. 1.
 |
| | Fig. 1 Self-healing capacitive pressure sensors based on N-ligand-terminated oligosiloxanes and their crosslinking with Co(II). | |
Results and discussion
Guided by the material design principles outlined previously, we first investigated how metal–ligand crosslinking density governs geometric stability during processing and operation in order to identify formulations that maintain mechanical compliance while preventing brittle failure. Because the metal–ligand to prepolymer ratio directly governs network connectivity and viscoelastic response, it plays a central role in determining device robustness. Initially, crosslinking of the prepolymer with Co2+ cations was investigated (Fig. 1). Cobalt was selected as the metal crosslinker based on previous studies, showing that Co2+-coordinated networks exhibit slightly higher Young's moduli (8.10 MPa) than other crosslinked systems while retaining excellent stretchability and self-healing efficiency (61%), as determined by tensile pull tests.58 Detailed synthetic procedures are provided in the Experimental section and in prior reports.58,59 To achieve an optimal balance between autonomous self-healing and shape stability upon molding, a series of metal–ligand crosslinking ratios were systematically examined, as shown in Fig. S1. At low prepolymer to metal–ligand ratios (1
:
0.5), the polymers, although capable of self-healing, displayed excessive viscoelasticity that led to pronounced deformation over time. Although initially stable, these polymers underwent geometric deformation even at room temperature and, under applied stress, failed to preserve structural consistency, ultimately compromising their functionality as capacitive pressure sensors. Increasing the metal–ligand ratio to 1
:
0.75 resulted in partial deformation (approximately 80%), indicating improved structural integrity while preserving a degree of viscoelastic response. Notably, at a 1
:
1 metal–ligand ratio, the polymer exhibited excellent geometric stability, remaining dimensionally intact after demolding while preserving efficient autonomous self-healing. For this difunctional N-ligand-terminated polymer forming octahedral Co2+ complexes, this stoichiometry best balances coordination saturation and network connectivity. At this stoichiometry, the formation of dynamic coordination crosslinks promotes efficient intermolecular network percolation while limiting intrachain coordination and avoiding excessive network constraint. This balance enables the material to maintain robust shape stability while preserving sufficient segmental mobility for dynamic bond exchange, which is essential for effective self-healing. When the metal–ligand content is increased beyond this ratio (e.g., 1
:
2), the higher density of crosslinks can lead to an over-constrained network. This results in reduced chain mobility, increased stiffness, and a transition toward more brittle mechanical behavior. Under these conditions, the restricted segmental dynamics hinder bond rearrangement across damaged interfaces, leading to incomplete or suppressed self-healing. To further probe for the mechanical properties of the self-healing materials, tensile pull testing by dynamic mechanical analysis (DMA) was performed on the self-healing materials crosslinked at a 1
:
1 metal–ligand ratio, as shown in Fig. S2. A Young's modulus of 0.51 MPa was determined from the initial linear region of the tensile stress–strain curves for the pristine materials. The self-healing efficiency, calculated based on the recovery of strain at break, was found to be approximately 68%.
To assess the autonomous repair capability of the dynamically crosslinked network, the self-healing behavior of the system was evaluated by monitoring the time required to close cracks of varying widths using optical microscopy, as shown in Fig. 2 and Fig. S3. As expected, narrow cracks (between 100 and 300 µm) were found to heal rapidly, typically within a couple of hours at room temperature, whereas wider cracks (around 500 to 600 µm) required 3–4 hours to heal. This trend reflects the increased time needed for polymer chain diffusion and redistribution across larger damaged interfaces. In addition, brittle samples, resulting from an increased crosslinking density due to excessively high metal–ligand content (2
:
1 ratio), displayed minimal or no self-healing, indicating that over-crosslinking severely restricts polymer chain mobility and suppresses the dynamic bond exchange required for healing. These results confirm that self-healing efficiency is governed by a delicate interplay between crosslinking density, crack width, and healing time, underscoring the importance of optimizing network dynamics for practical device applications.
 |
| | Fig. 2 Average crack width upon mechanical damage as a function of time. Insets present photographs of self-healing materials upon damage and after self-healing. | |
To evaluate device-level electrical stability, we investigated the self-healing polymer in conjunction with carbon nanotube (CNT) electrodes. While CNT-based electrodes and conductive networks have been widely used in flexible and self-healing sensors, many reported systems rely on composite-based conductive layers and require external stimuli such as heat, light, or electrical input to restore conductivity.63,64 Moreover, only limited studies have combined CNT electrodes with autonomously self-healing dielectrics for room-temperature, capacitive pressure sensing.65,66 In contrast, the present device was designed to operate with the autonomously self-healing metal–ligand dielectric at room temperature, enabling repeated cut–heal cycles without external activation. CNTs were selected as conductive electrodes here due to their high electrical conductivity, mechanical flexibility, and proven compatibility with soft, deformable substrates. Notably, compared to metallic thin films or brittle conductive fillers, CNT networks can better accommodate large strains and damage events while maintaining conductive pathways, making them particularly well-suited for self-healing and flexible pressure-sensing applications where repeated deformation and cutting are expected.
To confirm the suitability of the CNT electrodes for self-healing pressure sensors, their electrical robustness under repeated damage and repair was first evaluated by monitoring the relative resistance change (ΔR/R0) over 4 cut–heal cycles, as shown in Fig. 3a. Multiple samples were used for the study and underwent subsequent damage–heal cycles, and electrical conductivity was measured at the top and bottom of the polymer to confirm uniformity. After the first damage–healing cycle, the resistance remains close to the initial value. In contrast, a gradual increase in resistance was observed following the second and third cutting–healing events. Importantly, even after four consecutive damage–healing cycles, which cumulatively lead to an increase in overall resistance, the electrodes remain within an operational range suitable for pressure sensing. The observed resistance increase can be attributed to localized defects, junction loss, and slight CNT misalignment induced during repeated damage and repair cycles. Nevertheless, the electrode network retained sufficient connectivity to preserve sensing functionality.
 |
| | Fig. 3 (a) Relative resistance change (ΔR/R0) of the CNT electrode layers for multiple sensors subjected to successive cutting and self-healing cycles; (b) hysteresis behaviour of the capacitive pressure sensor during loading and unloading cycles measured before cutting and after self-healing for pressures less than 1 MPa; and (c) relative capacitance change (ΔC/C0) of the self-healing polymer under cyclic loading at 60 kPa and 840 kPa. | |
In parallel with the evaluation of electrode stability, the pressure-sensing performance of the capacitive devices was assessed through cyclic loading and unloading tests conducted before and after cutting and self-healing. As shown in Fig. 3b, the sensors exhibited a largely comparable capacitive response following damage and repair for pressures less than 1 MPa, indicating that the self-healing process effectively restores both the mechanical integrity of the dielectric layer and the electrical functionality of the device. Notably, a modest increase in the separation between the loading and unloading curves was observed after healing. The difference between the loading and unloading capacitance responses can be attributed to structural and interfacial changes induced by cutting and healing cycles. In addition, the viscoelastic nature of the polymer matrix can introduce a mechanical lag, further contributing to the observed behaviour. Nevertheless, the sensors maintained stable and reproducible responses under applied pressures of up to approximately 1 MPa, demonstrating their suitability for moderate-to-high-pressure sensing applications. Overall, these results confirmed that autonomous self-healing does not significantly compromise sensor performance, reinforcing the potential of self-healing polymer-based capacitive sensors for long-term, durable operation in applications requiring mechanical resilience and reliable pressure detection.
Building on these findings, the capacitive response of the self-healing polymer was evaluated under cyclic loading at low to moderate (60 kPa) and high (840 kPa) pressures, as shown in Fig. 3c and Fig. S4. These regimes were chosen to represent wearable and tactile sensing conditions as well as higher-pressure scenarios such as robotic gripping and industrial handling.67,68 The relative capacitance change (ΔC/C0) showed stable and reproducible behaviour, with consistent pressure sensitivity maintained for up to 2000 cycles. At 60 kPa, the sensor exhibited a largely linear response with minimal hysteresis, indicating excellent mechanical recovery. At 840 kPa, slight deviations from linearity and increased hysteresis were observed, attributed to viscoelastic deformation and minor structural relaxation under repeated stress. Despite this, reliable functionality was retained across the entire pressure range. Sensitivities of 26.4 kPa−1 and 71.3 kPa−1 were obtained in the low- and high-pressure regimes, respectively. Fatigue testing at ∼860 kPa revealed wear and tear beyond 10
000 cycles, indicating the upper operational limits of the device. Prior to failure, ΔC/C0 remained stable and reproducible, confirming reliable performance within the intended pressure range.
To further assess the long-term durability of the self-healing capacitive pressure sensors under realistic operating conditions, fatigue testing was performed before and after self-healing under cyclic loading at 500 kPa for 2000 cycles, as shown in Fig. 4. This pressure level was selected as a representative moderate-to-high load relevant to practical sensing scenarios, while also providing a demanding condition to evaluate the mechanical robustness and stability of the self-healing sensor. Following cutting and autonomous self-healing, the sensor displayed only minor deviations from the pre-damage capacitance response, indicating that the healing process effectively restores device functionality. Quantitatively, the self-healed polymer retained over 90% of its original sensing performance, demonstrating recovery of both structural integrity and electrical characteristics. The pressure sensitivity at moderate-to-high pressures decreased from 64.1 kPa−1 before cutting to 47.8 kPa−1 after healing. However, the healed sensor maintained a stable and repeatable response under identical loading conditions, comparable to its pre-damage behavior. This resilience supports the suitability of the sensor for long-term operation under continuous mechanical stress.
 |
| | Fig. 4 Relative change in capacitance for the self-healing polymer sensor during cyclic response at 500 kPa before cutting (top) and after healing (bottom). | |
For better contextualization, a comparison between the performance of the present sensor and other reported pressure sensors is provided in Table 1, highlighting the competitive balance between sensitivity, durability, and self-healing capability achieved by the current sensing platform. Notably, while Table 1 focuses on piezoresistive and capacitive sensors, which represent the most widely studied and technologically relevant platforms for stretchable and self-healable pressure sensing, other sensing mechanisms have also been explored in this field. These include piezoelectric, triboelectric, and optical (e.g., mechanochromic or photonic) sensors.69–71 Piezoelectric and triboelectric devices can generate self-powered signals and exhibit high sensitivity, particularly under dynamic stimuli.72,73 However, they are generally less effective for static pressure detection and can be more challenging to integrate with self-healing polymer systems. Optical-based sensors offer advantages in terms of signal decoupling and noise, but often require more complex instrumentation and are less compatible with scalable, flexible device architectures.74,75 Given these considerations, piezoresistive and capacitive platforms remain the most practical and widely adopted approaches for self-healable pressure sensors, which motivated their focus in Table 1.
Table 1 Comparison of previously reported self-healing pressure sensors with the current work
| Self-healing material |
Electrode materials |
Sensor type |
Pressure range (kPa) |
Sensitivity (kPa−1) |
Ref. |
| Polystyrene microsphere |
LIG-PU, Cu |
Piezoresistive |
<1 |
7.21 |
35 |
| 1–10 |
130 |
| 10–100 |
157 |
| MXene-based polyurethane composite |
MXene-based |
Piezoresistive |
0.20–1.70 |
281.5 |
29 |
| 1.70–5.70 |
509.8 |
| 5.70–20.3 |
66.7 |
| PHAE |
PET-Cu |
Capacitive |
<0.5 |
2.45 |
30 |
| FPU |
rGO |
Piezoresistive |
0–300 |
9.45 |
34 |
| IPNPUA |
— |
Capacitive |
700 |
0.125 |
76 |
| Disulfide-crosslinked polyurethane |
PI-Ag |
Piezoresistive |
100 Pa–50 kPa |
197 |
32 |
| Imine-based PDMS |
CNTs |
Capacitive |
<1 MPa |
71 |
This work |
In order to further increase the performance of the capacitive sensors, the self-healing behaviour and sensing performance of microstructured dielectric sensors were then investigated. Notably, our initial focus on unstructured self-healing polymer dielectrics was intended to establish baseline material performance and healing efficiency in capacitive pressure sensors. Building on this foundation, we introduced microstructured architectures to enhance pressure sensitivity, particularly in the low-pressure regime relevant to wearable and human-interfacing applications.77 Among the available micro-structuring strategies to improve device sensitivity to pressure change, mesoamerican pyramidal (MAP) geometries were selected due to their well-established ability to amplify pressure-induced deformation through progressive collapse mechanisms, thereby increasing effective dielectric compressibility.61,78 A detailed analysis of MAP geometrical parameters, their impact on device performance, and comparisons with alternative microstructures (e.g., micropillars) can be found in our previous work.61 Integrating MAP structures into a dynamic, self-healing dielectric further enabled us to assess whether such sensitivity enhancing architectures remain compatible with reversible metal–ligand networks. To this end, the MAP-based sensors were systematically evaluated under controlled loading conditions to probe pressure sensitivity, mechanical stability, and structural durability. The MAP structures were subjected to a cut and heal cycle to analyse the self-healing capacity without deformation of microstructures, as shown in Fig. S5, and the relative change in capacitance response was also studied before cut and after healing for a 20 g weight, as depicted in Fig. S6.
Incorporation of MAP markedly increased the effective compressibility of the dielectric layer, resulting in a pronounced enhancement of the pressure capacitance response. Stepwise loading experiments were first conducted using incrementally increasing weights (Fig. 5a and c). The MAP-based sensor exhibited a clear and reproducible stepwise increase in the normalized capacitance change (ΔC/C0) with increasing applied load, confirming stable and reliable electromechanical coupling. When compared to the pristine (flat) self-healing sensor, the MAP device consistently displayed a larger capacitance change at equivalent pressures, directly demonstrating the pressure-amplification effect imparted by the microstructured architecture. This enhancement is particularly evident in the low-pressure regime (Fig. 5b), where the MAP sensor achieved a sensitivity of 0.135 kPa−1, nearly twice that of the pristine device (0.07 kPa−1). The sensitivity enhancement arises from the progressive deformation of the micro-pyramids, which increases the effective electrode contact area while simultaneously reducing the dielectric thickness under small, applied loads. To assess durability and operational stability, cyclic loading tests were performed under a constant load of 20 g (≈ 0.4 kPa), for 20 consecutive cycles (Fig. 5d). The MAP sensor maintained a repeatable and reversible capacitance response throughout cycling, indicating robust electromechanical behavior. However, slightly increased signal fluctuations were observed relative to the pristine sensor. These variations can be attributed to microstructural deformation and partial viscoelastic relaxation of the self-healing polymer's MAP features under repeated compression. MAP structures remain stable during single loading and unloading (<10 kPa), as shown in Fig. 5c, but under repeated cycling, they permanently deformed. Notably, the magnitude of signal variation increased with applied pressure. At pressures at higher loading of weights (≈ 0.6 kPa), permanent deformation of the micro-pyramids was observed (Fig. S7), signalling the onset of structural collapse. Beyond this threshold, the MAP dielectric layer effectively transitions toward a flattened, pristine- like configuration, thereby diminishing the microstructure-induced sensitivity enhancement. Overall, these results demonstrate that MAP micro-structuring is an effective strategy for significantly improving low-pressure sensitivity in self-healing capacitive sensors, while also defining a clear upper operating pressure limit governed by microstructural mechanical stability. This balance between enhanced sensitivity and structural robustness provides important design guidelines for integrating dynamic, self-healing polymers into pressure amplifying microarchitectures.
 |
| | Fig. 5 (a) Relative change of pressure of the pristine pressure sensor for pressures less than 10 kPa; (b) pressure response comparison between MAP and pristine sensors in the low-pressure range; (c) relative change of capacitance of the microstructured MAP at pressures below 10 kPa (using weights); (d) cyclic response under 20 g loading for 20 cycles for MAP microstructures. | |
Conclusions
In summary, this work establishes a structure–property relationship for capacitive pressure sensors based on metal–ligand coordinated self-healing polymers. By correlating metal–ligand crosslinking density with viscoelastic behavior, geometric stability, and healing efficiency, an optimal 1
:
1 metal–ligand ratio was identified. These conditions afforded shape-stable dielectrics that remained dimensionally intact after molding while preserving rapid, room-temperature autonomous self-healing. The optimized material was successfully integrated into MAP microstructured capacitive sensors with compliant CNT electrodes, enabling repeated cut and heal cycles and stable operation across a wide pressure range of approximately 60 kPa to 1 MPa. At the device level, this structure exhibited robust electrical and mechanical performance, retaining over 90% of its original sensing performance after healing. Pressure sensitivities of 64.1 kPa−1 before damage and 47.8 kPa−1 after healing were measured, with stable and repeatable responses under identical loading conditions. Fatigue testing at 500 kPa over 2000 cycles further confirmed long-term durability. Collectively, these results establish a clear structure and property performance relationship, where insufficient crosslinking leads to excessive viscoelastic flow and poor shape retention, while over-crosslinking suppresses chain mobility and healing efficiency. The optimized self-healing materials enabled a unique combination of mechanical resilience, autonomous healing, and device-level reliability, advancing metal–ligand based self-healing polymers from material level demonstrations to practical capacitive pressure sensors.
Author contributions
All authors contributed to the manuscript. All authors have given approval to the final version of the manuscript.
Conflicts of interest
The authors declare no competing financial interest.
Data availability
The data supporting this article have been included as part of the supplementary information (SI). Supplementary information is available. See DOI: https://doi.org/10.1039/d6nj00535g.
Acknowledgements
This work was funded by the Natural Sciences and Engineering Research Council of Canada (NSERC) through a Discovery Grant (RGPIN-2022-04428). N. V. thanks NSERC for financial support through an Undergraduate Student Research Award.
References
- N. T. P. Vo, T. U. Nam, M. W. Jeong, J. S. Kim, K. H. Jung, Y. Lee, G. Ma, X. Gu, J. B.-H. Tok, T. Il Lee, Z. Bao and J. Y. Oh, Autonomous self-healing supramolecular polymer transistors for skin electronics, Nat. Commun., 2024, 15, 3433 CrossRef CAS PubMed.
- Y. Zhou, X. Jiang, X. Yang, H. Liang, X. Xie and W. Fu, Self-Lubricating and Self-Healing Polyurethane Elastomer as a Meniscal Prosthesis to Delay Osteoarthritis Progression, Adv. Funct. Mater., 2025, 38, 2420344 CrossRef.
- W. Li, J. Guo and W. Tian, Polyurea/hydrogen-bonded reduced graphene oxide composite coating with self-repairing functions for applications of anti-cavitation and anti-corrosion, Prog. Org. Coat., 2025, 200, 108979 CrossRef CAS.
- S. Wang and M. W. Urban, Self-healing polymers, Nat. Rev. Mater., 2020, 5, 562–583 CrossRef CAS.
- S. Jadoun, Synthesis, Mechanism, and Applications of Self-healing Materials, Biomater. Devices, 2024, 2, 225–240 Search PubMed.
- C. Liu, S. O. Kelley and Z. Wang, Self-Healing Materials for Bioelectronic Devices, Adv. Mater., 2024, 36, 2401219 CrossRef CAS PubMed.
- S. Chen, S. Fan, Z. Qiao, Z. Wu, B. Lin, Z. Li, M. A. Riegler, M. Y. H. Wong, A. Opheim, O. Korostynska, K. M. Nielsen, T. Glott, A. C. T. Martinsen, V. H. Telle-Hansen and C. T. Lim, Transforming Healthcare: Intelligent Wearable Sensors Empowered by Smart Materials and Artificial Intelligence, Adv. Mater., 2025, 37, 2500412 CrossRef CAS PubMed.
- Z. Li, J. Lu, T. Ji, Y. Xue, L. Zhao, K. Zhao, B. Jia, B. Wang, J. Wang, S. Zhang and Z. Jiang, Self-Healing Hydrogel Bioelectronics, Adv. Mater., 2024, 36, 2306350 CrossRef CAS PubMed.
- J. Jung, S. Lee, H. Kim, W. Lee, J. Chong, I. You and J. Kang, Self-healing electronic skin with high fracture strength and toughness, Nat. Commun., 2024, 15, 9763 CrossRef CAS PubMed.
- C. Jiao, J. Liu, S. Yan, Z. Xu, Z. Hou and W. Xu, Hydrogel-based soft bioelectronic interfaces and their applications, J. Mater. Chem. C, 2025, 13, 2620–2645 RSC.
- S. Bin Choi, J. S. Meena, J. Joo and J.-W. Kim, Autonomous self-healing wearable flexible heaters enabled by innovative MXene/polycaprolactone composite fibrous networks and silver nanowires, Adv. Compos. Hybrid Mater., 2023, 6, 227 CrossRef.
- R. S. Srivastav and A. P. More, A Comprehensive Review of Self-Healing Polymers: Mechanisms, Types, and Industry Implications, Polym. Adv. Technol., 2025, 36, e70092 CrossRef CAS.
- J. Kang, J. B.-H. Tok and Z. Bao, Self-Healing Soft Electronics, Nat. Electron., 2019, 2, 144–150 CrossRef.
- S. An, M. W. Lee, A. L. Yarin and S. S. Yoon, A review on corrosion-protective extrinsic self-healing: Comparison of microcapsule-based systems and those based on core-shell vascular networks, Chem. Eng. J., 2018, 344, 206–220 CrossRef CAS.
- P. Wan, S. Wu, Q. Liu, H. Wang, X. Gong, Z. Zhao, S. Xu, J. Jiang, L. Fan and L. Tu, Extrinsic self-healing asphalt materials: A mini review, J. Cleaner Prod., 2023, 425, 138910 CrossRef CAS.
- A. Verma, K. Bhushan and H. Singh, Nanocomposites for extrinsic self-healing polymer Materials: A comprehensive review of their repair behaviour, Results Chem., 2025, 13, 101973 CrossRef CAS.
- S.-M. Yang, S. Zhou and J.-Y. Yuan, Self-Healing Elastomers and Coatings via Metal Coordination Bonds, Chem. – Eur. J., 2025, 31, e202404038 CrossRef CAS PubMed.
- C. Chen, T. Shen, J. Yang, W. Cao, J. Wei and W. Li, Room-Temperature Intrinsic Self-Healing Materials: A review, Chem. Eng. J., 2024, 498, 155158 CrossRef CAS.
- S. Zhou, N. Qi, Z. Zhang, P. Jiang, A. Li, Y. Lu and X. Su, Recent progress in intrinsic self-healing polymer materials: Mechanisms, challenges and potential applications in oil and gas development, Chem. Eng. J., 2025, 511, 161906 CrossRef CAS.
- Z. Xie, B.-L. Hu, R.-W. Li and Q. Zhang, Hydrogen Bonding in Self-Healing Elastomers, ACS Omega, 2021, 6, 9319–9333 CrossRef CAS PubMed.
- C. Wang, N. Liu, R. Allen, J. B.-H. Tok, Y. Wu, F. Zhang, Y. Chen and Z. Bao, A Rapid and Efficient Self-Healing Thermo-Reversible Elastomer Crosslinked with Graphene Oxide, Adv. Mater., 2013, 25, 5785–5790 CrossRef CAS PubMed.
- H. Park, T. Kang, H. Kim, J.-C. Kim, Z. Bao and J. Kang, Toughening self-healing elastomer crosslinked by metal–ligand coordination through mixed counter anion dynamics, Nat. Commun., 2023, 14, 5026 CrossRef CAS PubMed.
- L. Cao, Z. Gong, C. Liu, J. Fan and Y. Chen, Design and fabrication of mechanically strong and self-healing rubbers via metal-ligand coordination bonds as dynamic crosslinks, Compos. Sci. Technol., 2021, 207, 108750 CrossRef CAS.
- X. You, H. Xu, C. Li, J. Wei, N. Liu and D. Fang, Synthesis of room-temperature self-healing network polymers based on multiple metal–ligand coordination interactions, J. Polym. Res., 2025, 32, 24 CrossRef CAS.
- H. Zheng, N. Lin, Y. He and B. Zuo, Self-Healing, Self-Adhesive Silk Fibroin Conductive Hydrogel as a Flexible Strain Sensor, ACS Appl. Mater. Interfaces, 2021, 13, 40013–40031 Search PubMed.
- Y. Liu, F. Wang, Z. Hu, M. Li, S. Ouyang, Y. Wu, S. Wang, Z. Li, J. Qian, L. Wang and S. Ma, Applications of cellulose-based flexible self-healing sensors for human health monitoring, Nano Energy, 2024, 127, 109790 CrossRef CAS.
- Y. Zhang, Q. Lei, R. Liu, L. Zhang, B. Lyu, L. Liu and J. Ma, Self-healing cellulose-based flexible sensor: A review, Ind. Crops Prod., 2023, 206, 117724 CrossRef CAS.
- R. Abouzeid, M. Shayan, T. Wu, J. Gwon, T. A. Kärki and Q. Wu, Highly Flexible, Self-Bonding, Self-Healing, and Conductive Soft Pressure Sensors Based on Dicarboxylic Cellulose Nanofiber Hydrogels, ACS Appl. Polym. Mater., 2023, 5, 7009–7021 CrossRef CAS PubMed.
- M. Yang, Y. Cheng, Y. Yue, Y. Chen, H. Gao, L. Li, B. Cai, W. Liu, Z. Wang, H. Guo, N. Liu and Y. Gao, High-Performance Flexible Pressure Sensor with a Self-Healing Function for Tactile Feedback, Adv. Sci., 2022, 9, 2200507 CrossRef CAS PubMed.
- G. Ma, F. Guo, Y. Li, X. Luo, C. Luo, Q. Jin, H. Wu, J. Fu, M. Zhang and Y. Long, A novel 3D-Printed self-healing, touchless, and tactile multifunctional flexible sensor inspired by cutaneous sensory organs, Compos. Commun., 2025, 54, 102287 CrossRef.
- S. Bin Choi and J.-W. Kim, Dual-responsive fully self-healing triboelectric pressure sensor: Integrating truncated sphere morphology with deep learning-enhanced signal, Nano Energy, 2024, 128, 109833 CrossRef CAS.
- X. Sun, Q. He, Y. Hou, X. Zheng, P. Bi, Y. Xu, X. Zhang, Y. Liu, R. Xiong, Y. Yang and Z. Wang, Self-Healing Flexible Pressure Sensor for Human Motion Detection Based on Silver-Nanoparticle-Modified Polyimide Membranes, ACS Appl. Polym. Mater., 2023, 5, 5951–5960 CrossRef CAS.
- Y. Li, D. Yang, Z. Wu, F.-L. Gao, X.-Z. Gao, H.-Y. Zhao, X. Li and Z.-Z. Yu, Self-adhesive, self-healing, biocompatible and conductive polyacrylamide nanocomposite hydrogels for reliable strain and pressure sensors, Nano Energy, 2023, 109, 108324 CrossRef CAS.
- H. Zhu, D. Dong, Y. Wei, H. Lu, Y. Zhong, M. Wei, X. Lai, H. Li and X. Zeng, Self-Healing, Degradable, and Biobased Polyurethane Elastomer for High-Performance Piezoresistive Pressure Sensors with a Hump-like Microstructure, Langmuir, 2025, 41, 5603–5613 Search PubMed.
- Q. Tian, W. Yan, Y. Li and D. Ho, Bean Pod-Inspired Ultrasensitive and Self-Healing Pressure Sensor Based on Laser-Induced Graphene and Polystyrene Microsphere Sandwiched Structure, ACS Appl. Mater. Interfaces, 2020, 12, 9710–9717 CrossRef CAS PubMed.
- S. J. Benight, C. Wang, J. B. H. Tok and Z. Bao, Stretchable and self-healing polymers and devices for electronic skin, Prog. Polym. Sci., 2013, 38, 1961–1977 CrossRef CAS.
- H. Yue, Z. Wang and Y. Zhen, Recent Advances of Self-Healing Electronic Materials Applied in Organic Field-Effect Transistors, ACS Omega, 2022, 7, 18197–18205 CrossRef CAS PubMed.
- K. Liu, B. Ouyang, X. Guo, Y. Guo and Y. Liu, Advances in flexible organic field-effect transistors and their applications for flexible electronics, npj Flexible Electron., 2022, 6, 1 CrossRef CAS.
- W. Wang, Z. He, C. Di and D. Zhu, Advances in organic transistors for artificial perception applications, Mater. Today Electron., 2023, 3, 100028 CrossRef.
- N. A. Andreeva and V. V. Chaban, Self-healing in dielectric capacitors: a universal method to computationally rate newly introduced energy storage designs, Phys. Chem. Chem. Phys., 2024, 26, 29393–29405 RSC.
- K. Li, Z. Xu, S. Zhao, X. Meng, R. Zhang, J. Li, J. Leng, G. Zhang, D. Cao and R. Sun, Biomimetic, recyclable, highly stretchable and self-healing conductors enabled by dual reversible bonds, Chem. Eng. J., 2019, 371, 203–212 CrossRef CAS.
- H. Gao, J. Xu, S. Liu, Z. Song, M. Zhou, S. Liu, F. Li, F. Li, X. Wang, Z. Wang and Q. Zhang, Stretchable, self-healable integrated conductor based on mechanical reinforced graphene/polyurethane composites, J. Colloid Interface Sci., 2021, 597, 393–400 CrossRef CAS PubMed.
- T.-M. Jang, W. B. Han, S. Han, A. Dutta, J. H. Lim, T. Kim, B. H. Lim, G.-J. Ko, J.-W. Shin, R. Kaveti, H. Kang, C.-H. Eom, S. J. Choi, A. J. Bandodkar, K.-S. Lee, E. Park, H. Cheng, W.-H. Yeo and S.-W. Hwang, Stretchable and biodegradable self-healing conductors for multifunctional electronics, Sci. Adv., 2024, 10, eadp9818 Search PubMed.
- Y. Lin, T. Fang, C. Bai, Y. Sun, C. Yang, G. Hu, H. Guo, W. Qiu, W. Huang, L. Wang, Z. Tao, Y. Lu and D. Kong, Ultrastretchable Electrically Self-Healing Conductors Based on Silver Nanowire/Liquid Metal Microcapsule Nanocomposites, Nano Lett., 2023, 23, 11174–11183 Search PubMed.
- T. D. Khanh, J. Joo and J.-W. Kim, Autonomous self-healing in a stretchable polybutadiene-based urethane and eutectic gallium indium conductive composite, npj Flexible Electron., 2024, 8, 79 CrossRef CAS.
- K. Parida, G. Thangavel, G. Cai, X. Zhou, S. Park, J. Xiong and P. S. Lee, Extremely stretchable and self-healing conductor based on thermoplastic elastomer for all-three-dimensional printed triboelectric nanogenerator, Nat. Commun., 2019, 10, 2158 CrossRef PubMed.
- Y. Lee, X. Tian, J. Park, D. H. Nam, Z. Wu, H. Choi, J. Kim, D.-W. Park, K. Zhou, S. W. Lee, T. A. Tabish, X. Cheng, S. Emaminejad, T.-W. Lee, H. Kim, A. Khademhosseini and Y. Zhu, Rapidly self-healing electronic skin for machine learning–assisted physiological and movement evaluation, Sci. Adv., 2025, 11, eads1301 CrossRef CAS PubMed.
- X. Dai, Q. Liang, Z.-H. Zhao, Y. Wu, J. Yang, J. Han, Y. Cao, Y. Wang, C.-H. Li, A. Zhong and L.-B. Huang, Self-powered sensors for flexible electronic skins capable of self-healing under multiple extreme environments, Nano Energy, 2024, 121, 109239 CrossRef CAS.
- J.-S. Benas, F.-C. Liang, M. Venkatesan, Z.-L. Yan, W.-C. Chen, S.-T. Han, Y. Zhou and C.-C. Kuo, Recent development of sustainable self-healable electronic skin applications, a review with insight, Chem. Eng. J., 2023, 466, 142945 CrossRef CAS.
- Z. Lu, W. Li, L. Zhu, Y. Zhang, Z. Ming, Y. Zhang, X. Zhou and J. Xiong, Self-healing electro-optical skin for dual-mode human-machine interaction, Nano Energy, 2025, 135, 110617 CrossRef CAS.
- A. Kausar, I. Ahmad, M. Maaza and P. Bocchetta, Self-Healing Nanocomposites—Advancements and Aerospace Applications, J. Compos. Sci., 2023, 7, 148 CrossRef CAS.
- L. Pernigoni, U. Lafont and A. M. Grande, Self-healing polymers for space: A study on autonomous repair performance and response to space radiation, Acta Astronaut., 2023, 210, 627–634 CrossRef CAS.
- N. Sun, X. Ma, B. Wang, J. Zheng, X. Wang, Z. Li, Z. Chen and Y. Liu, A novel strategy for designing high-performance self-healing polysiloxane-polyurea composites enhanced by dopamine-grafted cellulose nanofibers and Zn2+, Compos. Sci. Technol., 2025, 266, 111159 CrossRef CAS.
- G. Thangavel, M. W. M. Tan and P. S. Lee, Advances in self-healing supramolecular soft materials and nanocomposites, Nano Convergence, 2019, 6, 29 CrossRef PubMed.
- H. Wen, J. Sun, K. Yu, X. Yang, X. Dai and Z. Zhang, A self-healing and energy-dissipating impact-hardening polymer based on a variety of reversible dynamic bonds, Mater. Des., 2023, 231, 112057 CrossRef CAS.
- T. Hayashi and A. Shimojima, Self-healing materials based on dynamic properties of siloxane networks, J. Sol-Gel Sci. Technol., 2025, 116, 1995–2009 CrossRef CAS.
- M. Ahmadi, G. Pareras, M. Bin Yeamin, K. Amann-Winkel, A. Rimola, A. Poater and S. Seiffert, Coordination Geometry and Mineralization in Self-Healing Mussel-Inspired Hydrogels, Chem. Mater., 2024, 36, 3345–3358 CrossRef CAS.
- J. Pignanelli, Z. Qian, X. Gu, M. J. Ahamed and S. Rondeau-Gagné, Modulating the thermomechanical properties and self-healing efficiency of siloxane-based soft polymers through metal–ligand coordination, New J. Chem., 2020, 44, 8977–8985 RSC.
- J. Pignanelli, B. Billet, M. Straeten, M. Prado, K. Schlingman, M. J. Ahamed and S. Rondeau-Gagné, Imine and metal–ligand dynamic bonds in soft polymers for autonomous self-healing capacitive-based pressure sensors, Soft Matter, 2019, 15, 7654–7662 RSC.
- S. Vu, G. Nagesh, N. Yousefi, J. F. Trant, D. S.-K. Ting, M. J. Ahamed and S. Rondeau-Gagné, Fabrication of an autonomously self-healing flexible thin-film capacitor by slot-die coating, Mater. Adv., 2021, 2, 6676–6683 RSC.
- L. Rose, G. Nagesh, P. Das, D. Skaf, F. Motaghedi, S. Rondeau-Gagné and M. J. Ahamed, Exploring mesoamerican pyramidal micro-structures in soft capacitors for positive and negative pressure sensing, Flex. Print. Electron., 2025, 10, 25003 CrossRef.
- Z. Li, F. Sun, L. Rose, G. Nagesh, N. K. Shekar, P. R. Pedapati, A. Ansar, R. Kumar, V. Damodaran, D. Skaf, S. Rondeau-Gagné and M. J. Ahamed, Multilayered Single-Walled Carbon Nanotube-Based Flexible Temperature Sensor, IEEE Sens. J., 2025, 25, 193–204 CAS.
- X. Meng, H. Tang, X. Lü, J. Zhang, Y. Shi, Y. He and W. Bao, Biomimetic cell in-situ self-healing PCL/CNT conductive composites for flexible pressure sensors with high sensitivity and wide linear measurement range, Sci. China Inf. Sci., 2026, 69, 122404 CrossRef.
- L. Kong, Y. Yang, Z. Lin, B. Huang, L. Liao, Y. Wang and C. Xu, A ENR-based conductive film integrating electricity-triggered self-healing, damage detection and high sensitivity for flexible sensors, Chem. Eng. J., 2024, 479, 147624 CrossRef CAS.
- Y. Chen, X. Pu, M. Liu, S. Kuang, P. Zhang, Q. Hua, Z. Cong, W. Guo, W. Hu and Z. L. Wang, Shape-Adaptive, Self-Healable Triboelectric Nanogenerator with Enhanced Performances by Soft Solid–Solid Contact Electrification, ACS Nano, 2019, 13, 8936–8945 CrossRef CAS PubMed.
- A. Narayanan, T. M. Bhagyasree, A. Torris and S. S. Babu, A functionalized CNT-azobenzene-PVA-based self-healing aqueous gel as a conductive photo-responsive actuator, J. Mater. Chem. C, 2023, 11, 16571–16577 RSC.
- X. Wang, Y. Li, Y. Wang, W. Huang, X. Zhao, K. Chen, F. Luo and Y. Qin, Fabrication method and various application scenarios of flexible capacitive pressure sensor based on direct formation of conical structure, Chem. Eng. J., 2024, 496, 153957 CrossRef CAS.
- Z. Zhan, Y. Yang, W. Zuo, M. Xie and M. Ning, Recent advances and challenges of tactile sensing for robotics: from fundamentals to applications, Mater. Today Phys., 2025, 54, 101740 CrossRef.
- B. Cheng, C. Li, T. Ji, Y. Zhao, K. Gao, J. Hao and W. Xu, A triboelectric sensing array integrating material identification and self-healing enabled by a healable polyamide-based device unit, Nano Energy, 2024, 127, 109718 CrossRef CAS.
- Y. Jeong, C. Majidi and S. H. Ko, Self-Healing Soft Robots: Materials, Sensors and Integrated Systems, Int. J. Precis. Eng. Manuf., 2025, 26, 2781–2801 CrossRef.
- H. Bai, Y. S. Kim and R. F. Shepherd, Autonomous self-healing optical sensors for damage intelligent soft-bodied systems, Sci. Adv., 2026, 8, eabq2104 CrossRef PubMed.
- X. Dai, Q. Liang, Z.-H. Zhao, Y. Wu, J. Yang, J. Han, Y. Cao, Y. Wang, C.-H. Li, A. Zhong and L.-B. Huang, Self-powered sensors for flexible electronic skins capable of self-healing under multiple extreme environments, Nano Energy, 2024, 121, 109239 CrossRef CAS.
- G. Chen, Y. Zhu, D. Huang and S. Zhou, Self-powered and self-sensing devices based on piezoelectric energy harvesting, Sci. China: Technol. Sci., 2024, 67, 1631–1667 CrossRef CAS.
- X. Wang, G. Chen, K. Zhang, R. Li, Z. Jiang, H. Zhou, J. Gan and M. He, Self-Healing Multimodal Flexible Optoelectronic Fiber Sensors, Chem. Mater., 2023, 35, 1345–1354 Search PubMed.
- J. Zheng, Z. Wang, G. Chen, K. Hou and M. Zhu, Self-healing hydrogel optical fibers with programmable functions for multi-signal sensing and decoupling, Sci. China Mater., 2025, 68, 4107–4114 CrossRef.
- H. Wu, X. Luo, C. Wang, Q. Jin, Y. Li, F. Guo, W. Guo and Y. Long, 3D printing of robust, self-healing, and highly sensitive pressure sensor based on an interpenetrating polymer network elastomer, Colloids Surf., A, 2024, 685, 133248 CrossRef CAS.
- S. R. A. Ruth, L. Beker, H. Tran, V. R. Feig, N. Matsuhisa and Z. Bao, Rational Design of Capacitive Pressure Sensors Based on Pyramidal Microstructures for Specialized Monitoring of Biosignals, Adv. Funct. Mater., 2020, 30, 1903100 CrossRef CAS.
- F. Motaghedi, L. Rose, M. J. Ahamed, T. B. Carmichael and S. Rondeau-Gagné, A multifunctional thermochromic–elastomeric composite for integrated pressure and temperature sensing, RSC Appl. Polym., 2026, 4, 422–431 Search PubMed.
Footnote |
| † These authors contributed equally to this work. |
|
| This journal is © The Royal Society of Chemistry and the Centre National de la Recherche Scientifique 2026 |
Click here to see how this site uses Cookies. View our privacy policy here.