Europium nanoparticle label/lateral flow test strip integrated with a 3D-printed fluorescence smartphone reader for detection of melatonin in human blood

Abstract

Melatonin secretion by the pineal gland occurs predominantly at night, although ocular exposure to bright light suppresses its secretion. When measured under dim light conditions, the melatonin concentration in plasma provides a reliable indicator of the state of an individual's central circadian pacemaker in the hypothalamus. Specifically, the onset of melatonin secretion in the evening, conventionally defined as the time when the plasma concentration surpasses a threshold of 10 pg mL−1, serves as a gold-standard measure of the start time of physiological night. Current melatonin detection methods typically require expensive assays and instrumentation as well as trained personnel, or they lack sufficient sensitivity and anti-interference capabilities, which limit their use in point-of-need settings. To address these challenges, we developed a europium nanoparticle-based lateral flow immunoassay (EuNP-LFIA) integrated with a 3D-printed smartphone-based fluorescence reader for on-site melatonin detection in plasma. Six key parameters, namely readout time, EuNP size, antibody conjugation level, Tween-20 concentration, EuNP deposition volume, and the concentration of melatonin–bovine serum albumin on the nitrocellulose membrane, were systematically optimized. Upon optimization, the sensing platform exhibited highly sensitive detection of melatonin in buffer solution and achieved a limit of detection (LOD) of 9.99 pg mL−1. For melatonin-spiked plasma samples, the recovery rates ranged from 82.58% to 114.70%, indicating excellent repeatability and reliability. Overall, the proposed method possesses high sensitivity and accuracy, offering a portable, rapid (<15 min), cost-effective, and user-friendly solution for real-time monitoring of plasma melatonin.

Graphical abstract: Europium nanoparticle label/lateral flow test strip integrated with a 3D-printed fluorescence smartphone reader for detection of melatonin in human blood

Article information

Article type
Communication
Submitted
31 Dec 2025
Accepted
04 Mar 2026
First published
11 Mar 2026

Nanoscale Horiz., 2026, Advance Article

Europium nanoparticle label/lateral flow test strip integrated with a 3D-printed fluorescence smartphone reader for detection of melatonin in human blood

Z. Yang, X. Li, H. P. A. Van Dongen, Y. Lin, Y. Song and D. Du, Nanoscale Horiz., 2026, Advance Article , DOI: 10.1039/D5NH00853K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements