A wide range of methods currently exist for testing the presence of malaria, each with its own advantages and disadvantages. New technologies are urgently needed to develop more effective diagnosis tools to fight and eradicate malaria. Optical biosensors that employ surface plasmon resonance (SPR) techniques are a promising category of devices for detecting malaria biomarkers. One such biomarker is plasmodium lactate dehydrogenase (pLDH), a protein produced during the life cycle of the malaria parasite, which is a metabolic enzyme found in all plasmodium species, including the most widespread falciparum. This work reports on the design, probing, and experimental performance of an optical biosensor for detecting pLDH based on SPR and extraordinary optical transmission. The biosensor is composed of an aluminum metasurface made from an array of nanoholes. The sensor operates in the visible spectral region and achieves label-free sensing of plasmodium falciparum LDH (pfLDH) spiked in phosphate-buffered saline. The sensor has a spectral sensitivity of 360 nm per RIU and an LOD of 1.3 nM, equivalent to 45.6 ng mL−1 of pfLDH. This type of optical biosensor may offer a cost-effective and high sensitivity method for active infection diagnosis.
000 lives every year.1,2 For example, global malaria deaths in 2022 and 2023 were 600
000 and 597
000, respectively.3,4 Malaria cases and deaths are reducing at a very slow rate. The 2023 mortality rate, for instance, was 13.7 deaths per 100
000 population at risk, which was far higher than the World Health Organization target rate of 5.5. The target rate by 2030 is an optimistic 1.5 deaths per 100
000 population at risk.5 The disease mainly affects tropical African countries, with a four times higher mortality rate than the global average. The highest percentage of malaria cases reside in five countries: Nigeria (26%), the Democratic Republic of Congo (13%), Uganda (5%), Ethiopia (4%) and Mozambique (4%),3,5 where children are a large proportion of those affected. Plasmodium falciparum and vivax are the most widespread and deadly species causing malaria.1–3
Two malaria vaccines, RTS,S/AS01 (Mosquirix)6 and R21/Matrix-M,7 are currently being rolled out in endemic regions through routine childhood immunization.8,9 The aim is to eliminate and eradicate malaria by 2030.10 However, neither vaccine targets parasitic infections with 100% efficacy.11,12 The malaria vaccine RTS,S, for instance, offers only 30–50% protection, which is insufficient to interrupt transmission, and its efficacy diminishes over time.9,13 Due to the high rate of parasite replication, rapid mutation, complex lifecycle, global funding gap and ineffective diagnosis, large-scale vaccination efforts can be expected to meet significant challenges in endemic regions.13
Malaria rapid detection tests (mRDTs) are widely used to diagnose malaria in endemic regions and are aiding the above-mentioned vaccine programs. They are immunochromatographic antigen assays specific to histidine-rich protein-2 (HRP-2). The biomarker HRP-2 is the most abundant malaria antigen in infected blood. However, it is produced only by the plasmodium falciparum (pf) species. Therefore, the prevalence of non-pf species and deletion or mutation of the HRP-2 gene are misdiagnosed by mRDTs as false negative.14,15 Moreover, the sensitivity and specificity of more general pan-mRDTs in diagnosing sub-microscopic pf malaria infections or non-pfHRP-2 antigens are low.16 On the other hand, plasmodium lactate dehydrogenase (pLDH) is an alternative malaria biomarker produced by the active plasmodium parasite.17,18 It is an intracellular protein and final metabolic enzyme of the glycolytic pathway found in all plasmodium species,17,19,20 and therefore its detection avoids the selectivity problem of pfHRP-2.
Furthermore, conventional tools for malaria diagnosis like HRP-2 detecting mRDTs are time-consuming and expensive, requiring trained personnel and centralized laboratory equipment. On the other hand, optical biosensors, especially those operating under surface plasmon resonance (SPR) techniques, are simple to use, offering high sensitivity with a low limit of detection (LOD) and label-free sensing in real time. SPR sensors are commercially available, e.g. BIAcore™, and are used in industry and research laboratories to study chemical and biological interactions, such as antibody–antigen interactions and DNA–drug binding, amongst others.21–24 Therefore, they have the potential to be used as an alternative tool for detecting submicroscopic malaria infections and non-pfHRP-2 antigens (such as pLDH and aldolase).25,26
Plasmonic-based biosensing holds great promise for rapid and sensitive malaria diagnosis – particularly in regions with limited access to advanced diagnostic tools – by enabling early detection and monitoring of malaria infection at the point-of-care. These sensors have experimentally shown evidence for detecting low concentrations of pLDH spiked in a buffer solution or whole blood lysate.27,28 The best achieved LOD so far is 18 fM, based on a plasmon-enhanced fluorescence immunosensor.29 A recent review on optical and other biosensor assays for the diagnosis of malaria can be found in ref. 18 and 30. Despite promising results from the studies covered in the review, the majority of plasmonic-based biosensors have been fabricated using gold. A cost-effective alternative to gold for commercialization is aluminum, which is 10
000 times cheaper and its processing is more mature in semiconductor fabrication plants, making large area fabrication (e.g. films and nanostructured arrays) more accessible.31
Aluminum is both easy to fabricate and functionalize, with material properties that enable plasmon resonances across a broad optical band, in the UV-visible range (200–700 nm), due to its negative real permittivity (−5 to −60) and positive imaginary permittivity (1 to 30).32,33 Compared to gold (which spans the visible-NIR range and has broader SP resonances with a Q-factor ∼10–20) and silver (spans the visible-NIR range, with the sharpest resonances and Q ∼ 50), aluminum with a suitable patterning of nanostructures (such as in a photonic crystal fibre34–37 or nanohole array33), has moderate sharp resonances (Q ∼ 20–30) associated with propagating surface plasmons and localised plasmons. It also has a superior UV extension that can be an advantage when using analytes with UV absorption/fluorescence.
Furthermore, passivated aluminum (e.g., SiO2 coated) is non-toxic like gold, while silver is antibacterial but cytotoxic and has rapid degradation due to bulk oxidation. Aluminum shows no evidence of bulk oxidation – an oxide layer naturally forms on the aluminum surface during air exposure (if not passivated) and remains consistently stable for many days, effectively serving as a natural passivation layer that inhibits further oxidation.33,38–40 Further details on the fundamental plasmonic properties of aluminum and how they compare to other plasmonic materials like gold and silver can be found in recent review articles.41–43
In this work, we report on the design and experimental probing of a plasmonic-based malaria sensor using an aluminum metasurface. The sensor is an array of nanoholes and operates in the visible spectral region. It provides label-free sensing of pLDH, which we test by spiking pLDH into phosphate-buffered saline (PBS). We measure a sensor sensitivity of 360 nm per RIU (refractive index units), an LOD of 1.3 nM and an equilibrium binding affinity of 71 nM for the pfLDH antigen interaction with its IgG antibody. The LOD of 1.3 nM achieved using aluminum nanoholes is better than the LOD of 23.5 nM previously reported using gold nanoholes.28 Our results may therefore open up new possibilities for designing cost-effective and highly sensitive malaria sensors based on plasmonics. As the antibody we use also binds to pLDH from other plasmodium species, the detection of pfLDH and other species pLDH in real blood samples in the form of whole blood lysate would be the next step for the sensor's development.
The paper is structured as follows: in Section 2, we provide the physics of our sensor. In Section 3, we describe the optical setup, the experimental methods used, and the functionalization protocol followed to develop the plasmonic-based malaria sensor. In Section 4, we provide our experimental results and compare them with the calculated results based on a finite element method (FEM) using the software COMSOL. In Section 5, we provide a summary and an outlook on future work.
![]() | (1) |
is the wavenumber (propagation constant) of the incident light in free-space, λ is the free-space wavelength, εm is the permittivity of the metal and εd = nd2 is the permittivity of the dielectric on top of the metal, with nd as the refractive index of the dielectric layer. To satisfy mode-matching conditions between the incident light (k0) and SPs (ksp), a prism is usually used.44
When a plasmonic metal film is perforated with sub-wavelength holes forming a nanohole array (NHA), at a particular wavelength λR, the incident light is extraordinarily transmitted.47 SPs are responsible for this extraordinary optical transmission (EOT).48–53 The transmission is contrary to the classical diffraction law of Bethe for a sub-λ hole in a perfect electric conductor,54 where the transmission efficiency T decreases dramatically according to T ∼ (r/λ)4. For a plasmonic metal, the periodic arrangement of nanoholes provides the necessary momentum to overcome the mismatch between the wavenumber k0 of the incident light and the SP wavenumber ksp given in eqn (1).44,49 The NHA introduces a reciprocal lattice vector that provides the extra momentum
required for phase matching. The phase matching condition for SP excitation in NHAs is given by
,44,49 where k‖ = k0nd
sin
θ is the in-plane (x–y plane) wavevector component of the incident light, and θ is the angle of incidence from the z – axis.
is the reciprocal lattice vector of the NHA and is determined by the lattice constant a0. For a square lattice,
, where m and n are integers representing the diffraction orders in the x and y directions.44,49 At normal incidence, θ = 0, the incident wave can satisfy the condition ksp = Gxy to excite an SP, and an EOT peak occurs at wavelength λR given by44,55
![]() | (2) |
To a first approximation the coupling efficiency of incident light to SPs on the NHA sensor is determined by the grating momentum matching condition ksp = Gxy and how close it is satisfied. When loss and variation in nanohole geometry are included, the condition becomes broadened, with optimal coupling efficiency depending on how close to the plasmonic resonance the wavelength of the incoming light is. The grating momentum matching condition approach is a simple model however. A more rigorous approach is FEM simulation, resulting in a comprehensive spectral profile for the transmission, with peaks roughly at the locations predicted by the simple grating condition approach. A better coupling efficiency makes the transmission peak higher and improves the sensitivity, as the gradient can be larger. This then influences the sensor's LOD (at a fixed amount of noise), as a larger gradient gives a smaller LOD. Further details of this behavior are discussed later.
Since a NHA supports EOT-SPR peaks that shift depending on the local dielectric refractive index, a metasurface made of a NHA can use these peaks for sensing changes in the NHA environment due to antibody-antigen interactions, as discussed in Section 2. This sensing technique essentially monitors the shift of transmission peaks or intensity associated with bound analytes in the close vicinity of the localized SP fields. The approach is different from the conventional Kretschmann SPR sensor.59 EOT sensors exclude the need for a prism and offer comparable high sensitivity with more flexibility, while allowing for better integration and multiplexing.60,61
![]() | ||
| Fig. 1 Experimental setup, surface chemistry protocol, and measurement used for plasmonic biosensing of the malaria biomarker pfLDH. (a) The optical setup used to probe the sensor. It consists of a collimated broadband light source, a polarizing beamsplitter cube, two 10× microscope objectives, a plano-convex lens, and a detector – spectrometer connected to a computer. A nanohole array (NHA) sensor is placed between the two objectives. One objective is used to focus light onto the sensor and the other is used to collect the light transmitted through the sensor. An arrow (solid black line) shows the direction of light propagation. (b) The wet chamber enclosing the sensor. The chamber is filled with analyte solution (buffer + pfLDH) before the sensor is probed. pfLDHs are concentrated closer to the sensor surface as they bind to specific antibodies immobilized on the surface. (c) The atomic force microscope (AFM) image of the Al-NHA. The sensor is made of circular nanoholes in a square lattice, with a period a0 of 450 nm. The sensor thickness is approximately 166 nm. (d) The surface functionalization of the sensor. (i) The SiO2 layer is hydroxylated and coated with (3-glycidoxypropyl)trimethoxy silane (3-GPS), then protein A is anchored to the sensor through amine bonding. The 3-GPS forms a strong Si–O–Si covalent bond with the hydroxyl group on the SiO2 surface. The epoxide group of 3-GPS reacts with amine nucleophiles of protein A, forming a strong covalent bond.45 (ii) Antibodies (p-IgG) were then immobilized on the sensor through protein A.46 (iii) After functionalization, biomarker pLDH binds to the antibody p-IgG. (e) When pfLDH solution is injected into the wet chamber, the pfLDH molecules bind to p-IgG immobilized on the sensor surface causing a shift of the EOT resonance peak. A δλR = 5.5 nm spectral shift from the baseline peak (p-IgG peak) and δT = 0.016 transmission drop at λ = 660 nm (dashed line) is achieved when 250 nM of pfLDH is added. | ||
Our Al-NHA sensor is operated under static conditions, where there is no fluidic motion of the buffer and the binding dynamics have reached equilibrium, see Fig. 1(b). Different concentrations of pfLDH (REC 31737 from the Native Antigen Company) were prepared using PBS (pH 7.4, liquid, sterile-filtered from Merck) and injected into the wet chamber. The wet chamber is a silicone cavity with dimensions 20 × 20 × 1 mm, which encloses the sensing area. pfLDH molecules diffuse from the bulk solution and bind to p-IgG (MAB 12350 from the Native Antigen Company) immobilized on the sensor surface, forming a layer of protein on top of the antibodies. The p-IgG we use has the potential to bind to pLDH produced by all plasmodium species, although in this work, as a first study, we focus on binding and detection of pfLDH. The choice of antibody was motivated by its availability, verified specificity for pfLDH, and relevance for benchmarking against prior work (ref. 27 and 28).
The effective refractive index, naeff, of the protein layer depends on the bulk concentration of pfLDH and the binding affinity of the interaction. When the sensor is probed, it excites SPs at the alumina interfaces. The localized SP fields enclose the adsorbed protein layer, and any small change in naeff of the thin layer due to a change in pfLDH concentration of the bulk solution results in a spectral shift of the EOT peak.27
In Fig. 1(c), we show the topography of our Al-NHA sensor using an atomic force microscope (AFM). The sensor is made up of circular nanoholes in a square lattice. The Al surface is coated with a 5 nm conformal SiO2 layer, added on top of the nanoholes, and a 10 nm TiO2 adhesion layer between the aluminum and the glass substrate. We used the AFM topography and a scanning electron microscope (SEM) image (see Appendix A for details) of the Al-NHA to confirm the geometric parameters. The AFM scan confirms a period of 450 nm and a NHA thickness of 166 nm. The SEM scan confirms that the size of holes within the array has, on average, a hole diameter d = 242 nm. These geometric parameters match closely with those requested (a0 = 450 nm, t = 150 nm, d = 250 nm), which were chosen to give an EOT peak that overlapped with the spectrum of our white light source (600–700 nm).
Our SEM and AFM analysis gives an indication of the consistency of the nanoholes in terms of variations. Furthermore, we measured several different NHA's with the same specification and found similar results for the dimensions. The UV fabrication process used is known to give a high level of repeatability and high yield, as described in more detail in ref. 65 and 66, which our measurements confirm. This is an important aspect for eventual large-scale production and commercialisation of the sensor.
In Fig. 1(d), we show how the Al-NHA is turned into a malaria biosensor by functionalizing the SiO2-coating surface with antibodies that detect pfLDH. The process starts with silanization.45,67,68 The SiO2 passivated Al-NHA was sonicated in isopropanol for 15 minutes and cleaned in toluene, air-dried and hydroxylated through O2 plasma treatment. The NHA was then coated with 3-GPS, a silane coupling agent. The 3-GPS-coated Al-NHA was then heated in the oven at 130 °C and sonicated in toluene for 15 minutes. After washing to remove toluene traces, the NHA was conjugated to 1 mg mL−1 of protein A in PBS at room temperature overnight, then incubated in 50 µg per mL p-IgG solution in PBS for four hours at room temperature. Protein A binds the Fc region of the IgG antibodies,69,70 orienting the Fab region for optimal interaction with a target analyte (e.g. pfLDH).46 More details on the sensor functionalization are given in Appendix B.
To give a uniform spectrum across the wavelength range of interest, 450–900 nm, the measured spectra are normalized to the light source spectrum – light through the optical components of the setup in the absence of the sensor, which we call the reference spectrum, TR. The normalized transmission, T, of the sensor response is then calculated as
![]() | (3) |
In Fig. 1(e), we show one of our pfLDH sensing results, the case of 250 nM pfLDH solution injected into the wet chamber's cavity region. It can be clearly seen that the sensor is able to distinguish the pfLDH solution from the one without pfLDH. A shift in the spectral resonance δλR of 5.5 nm and a transmission drop δT of 0.016 (evaluated at λ = 660 nm) are observed within 5–10 minutes of the injection time.
| Tnorm = T/Tmax, | (4) |
The sensor sensitivity SR (where R represents the sensor response, R = λR or T), and LOD of the two sensing schemes are calculated as21,44,73
![]() | (5) |
![]() | (6) |
In Fig. 3(b), we show a cross-sectional view of the optical field distributions within the Al-NHA. A half of a unit cell is displayed. The electric field enhancement |E|/|E0| of the three simulated peak wavelengths: peak (i) λR = 545 nm, peak (ii) λR = 665 nm, and peak (iii) λ = 763 nm, are shown. E0 is the electric field amplitude of the incident plane wave. A detailed study of peak (i) based on the field distribution confirms that it is made of two plasmonic degenerate modes, one due to SP excitation at the glass/aluminum interface localized at the bottom corner and the other due to SP excitation at the analyte/aluminum interface localized at the top edge corner. In the spectral range of λ = 500–600 nm, the two modes have the same or nearly the same energy (frequency), resulting in a single peak in the transmission spectrum in air (neff = 1.00).
When neff is increased from 1.00 (air) to 1.335 (PBS) in steps of 0.05 RIU, peak (i) decomposes into two modes: as neff increases, the coupling strength between the evanescent NHA modes, SP modes, and directly transmitted modes, is enhanced and the hybrid mode starts to split. One mode remains at the original position, λ ∼ 545 nm, and the other redshifts to a higher wavelength. When neff reaches 1.335 (PBS), the two degenerate modes become completely separate and distinct, one at λ = 555 nm – close to peak (i), and another at λ = 665 nm – away from peak (i). The former is related to SP modes at the glass/aluminum interface, and the latter, at λ = 665 nm, is related to SP modes at the analyte/aluminum interface, and is presented as peak (ii) in Fig. 3(a) and (b).
As a result of the above observation, peak (ii) is identified as the most sensitive to refractive index changes and is the best EOT peak to monitor the NHA sensor behavior when various pfLDH concentrations are added to a suitable buffer like PBS. The fields are more concentrated on the analyte side, and therefore a small perturbation in the analyte layer refractive index, naeff, can be more easily tracked using peak (ii) than any other transmission peak.75 Peak (iii), at λ = 763 nm, is related to the intrinsic property of the aluminum metal. Since most of its near field is concentrated on the glass side, the peak responds less to changes in naeff. This peak is not as optimal for sensing applications and represents the interband transition of surface electrons in aluminum.31,33 Interband transitions in aluminum occur at photon energies greater than 1.5–1.6 eV (corresponding to a wavelength ∼800 nm). They can be characterized by a reduced EOT peak intensity, broader spectral feature and a sharp increase in absorption.
To study the impact of the 5 nm SiO2 passivation layer in the simulations, we modelled the system with and without the layer. We found that it resulted in a <1 nm red shift of the resonance peaks and negligible change in peak height. Thus, the layer protecting the aluminum from oxidation has only a small impact on the sensor's behavior. As the SiO2 layer prevents oxidation we expect little oxidation takes place in the experiment and so we can avoid effects that are usually associated with the build-up of an oxide layer, such as the broadening of the resonances, the lowering of the peak heights and their redshift due to the loss of support of plasmonic excitations. These effects for aluminum are discussed in more detail in ref. 31 and 76. The overall impact of oxidation effects would be a drop in the sensitivity and a subsequent increase in the LOD.
Sensitivity calculations are presented in Fig. 4(b). The sensor has a bulk sensitivity of Sexp = 360 nm per RIU, which is close to the simulated sensitivity of Ssim = 355 nm per RIU. These values are within the range of other aluminum57,58 and gold-based EOT sensors.78 For intensity sensing, we fixed the wavelength at λ0 = 660 nm and plotted the sensor transmittance drop, δTnorm, against the solvent refractive index to obtain the intensity sensitivity, ST. The results are presented in Fig. 4 (c). There is again a close match between the experimental (Sexp = 9.8876 a.u. per RIU) and simulation sensor sensitivity (Ssim = 9.2226 a.u. per RIU).
In a practical clinical setting, bulk calibration would need to be done with whole blood lysate. Blood has a refractive index range that depends on the physiological condition of the patient and the temperature of the experiment. For example, in the different stages of malaria, blood has different refractive index values, from normal stage (no infection) at 1.408, to ring stage at 1.396, trophozoite stage at 1.381, and schizont stage at 1.371.79,80 Once the blood is lysed in preparation for sensing, the values drop closer to that of PBS, in the range 1.335–1.35. The specific refractive index value in this range affects the baseline position of the transmission peak used for sensing. As can be seen from Fig. 4(b) and (c), the sensor response is linear over a wide range of refractive index (1.335–1.38) for both wavelength and intensity sensing. Therefore the use of a blood sample should in principle cause only a small linear shift in the baseline position of either λR or T after the initial deposit of the sample on the sensor surface. If the sensor is functionalized (see next section) the transmission peak will shift further over a short period of time due to binding of pfLDH to the immobilised antibodies on the surface (if the blood is infected). This shift will be relative to the initial one and so the amount will not depend on the initial offset due to the state of the blood.
![]() | ||
| Fig. 6 Surface sensing of pfLDH. (a) The simulated sensor model design. The first and last domains are perfectly matched layers (PML). The bottom PML layer is followed by the glass substrate and an aluminum nanohole (a quarter cell). A TiO2 layer is included as the adhesion layer between glass and aluminum. A 3-GPS layer is added on the SiO2 surface, followed by a protein A layer (pA), the antibody layer (p-IgG), the analyte layer (pfLDH), and the buffer layer. User-controlled meshing was applied and optimized according to the geometrical features of each domain. The permittivity of Al and TiO2 were taken from ref. 77. (b) Experimental spectra when 50 nM and 500 nM pfLDH solutions were added to the sensor. (c) The normalized spectra and a zoomed-in plot shows the spectral shift of pfLDH peaks from the p-IgG peak. The inset shows simulated peaks (Sim) that can be compared to the measured peaks (exp.). The legends in (b) are shared with (c) and the insets in (c). | ||
In Fig. 6(a), we show how the sensor model used in the simulations was designed in COMSOL. The refractive index and thickness of each layer are the key parameters in the sensor design. We used electromagnetic frequency-domain wave analysis in COMSOL to study the optical response of the sensor. A quarter cell was designed due to the rotational invariance of both excitation (plane wave) and material system (circular nanohole) along the wave propagation direction, normal to the sensor surface. Perfect electric conductor (PEC) and perfect magnetic conductor (PMC) boundary conditions were used. The former imposes symmetry for the magnetic fields by setting to zero the tangential component of the electric fields at the boundary. The latter imposes symmetry for the electric fields, prohibiting the electric current from flowing into the boundary. An interior periodic port based on floquet periodicity conditions was used to set up a plane wave excitation at the lower glass boundary. Meshing of the sensor domains was user-controlled. A free triangular fine mesh was assigned to all boundaries, and a free tetrahedral finer mesh was assigned to the Al-NHA, SiO2 and TiO2 domains. The remaining domains were assigned a free tetrahedral fine mesh. The top and bottom domains were terminated by strong absorbing perfectly matched layers. The permittivity of aluminum was taken from ref. 77. Ref. 78 and 81 present a similar design of a quarter-cell model. More details about the sensor design and parameters (e.g. layer thickness and the dependence of the refractive index of the pfLDH layer with its concentration in the bulk analyte) can be found in our theoretical study.82
In Fig. 6(b) and (c), we show two representative experimental spectra of the sensor response. When pfLDH solution is added to the wet chamber, pfLDH molecules bind to the immobilized antibodies and result in a redshift of the p-IgG peak. It can be seen that there is a close match between experiment and simulation. When a pfLDH solution of 50 nM was injected into the wet chamber, a redshift of 2.8 nm from the baseline p-IgG spectrum was observed (i.e. from 668 nm to ∼670 nm). Simulations show a similar trend; a redshift of 2.2 nm is obtained. A similar behavior was observed when a pfLDH solution of 500 nM was added to the wet chamber, as shown in Fig. 6(b) and (c). A regeneration process was performed between each measurement by rinsing the sensor with PBS many times until the p-IgG spectrum was recovered. A 2.5 M sodium chloride (NaCl) solution prepared in PBS was also used to ensure complete regeneration.
![]() | (7) |
![]() | (8) |
In Fig. 7, we plot the sensor responses, δλR and δT against the pfLDH concentration L0. A log scale is used on the x – axis. A Langmuir model is fitted to the measured data, as given in eqn (7) and (8), and the LODs are estimated from the graph based on eqn (6). The intersection of the σR gray region and the Langmuir line fits (solid and dashed lines) determines the value of ΔL0 for a particular sensing scheme, as described in Section 3.3. Comparing Fig. 7 (a) and (b), we see that intensity sensing offers a better LOD of 1.9 nM at λ = 660 nm compared to spectral sensing, which offers an LOD of 7.37 nM. Moreover, the LOD at 1.9 nM, can be improved to 1.3 nM by choosing a suitable fixed wavelength between 650 nm and 660 nm. The optimal wavelength is λ0 = 655 nm. The equilibrium dissociation constant of the pfLDH-(p-IgG) interaction is extracted from the model fitting and we find KDeq = 71 nM. The KDeq value is comparable with those reported in ref. 85. Therefore, KAeq is 1.408 × 107 M−1, which is a good binding affinity for use in the diagnosis of falciparum malaria.
The above analysis suggests that the best LOD is achievable with the Al-NHA in a transmission setup using the intensity sensing scheme. Moreover, spectral sensing is also limited by the spectrometer resolution.86 Our spectrometer was able to resolve δλ ∼ 0.2 nm. To resolve a smaller δλ on the order of 0.01 nm, due to a low pfLDH concentration, e.g. in the pM range, would require a high-resolution spectrometer that would add cost to the sensor, but is possible in principle. The calculated affinity represents a moderate to strong binding affinity, indicating that the pfLDH-(p-IgG) interaction in this study is stable, specific, and biologically relevant. Many natural biological interactions, such as antibody-antigen binding or enzyme–substrate interactions, have KDeq values in the nanomolar range, as discussed in ref. 87. Our measured LOD exceeds a previously reported LOD of an EOT sensor based on gold nanoholes.28
Understanding what the LOD of our sensor means in a real medical diagnostic setting requires clinical data analysis of the pfLDH antigen levels in individuals infected with malaria. Here, to have an idea of this, we focus on the parasite density of individuals attending hospitals (patients) in tropical endemic regions. The reported parasite density ranges from 5000 parasites (0.1% parasitemia) to 50 parasites (0.001% parasitemia) per microliter of blood.88 In malaria-naive individuals, pf infections of 500 to 1000 parasites per µL are taken as the mean parasitemia to show symptoms (fever, chills, headache, etc.).89 For the asexual stage, the relative amount of pfLDH produced by pf parasites at 0.001% parasite density (equivalent to 50 parasites per µL of blood) is estimated to be 1.87 ng mL−1.90 The performance of most rapid pLDH-specific mRDTs is relatively low in measuring such a density. For example, the LOD for the best pLDH-mRDT is reported to be 20–50 ng mL−1.91,92 A comparison of the performance between different malaria diagnosis techniques can be found in ref. 93 and 94. The Al-NHA sensor studied here offers a label-free detection of pfLDH with a modest LOD of 1.30 nM, equivalent to 45.6 ng mL−1, which is comparable to that of mRDTs. The sensor could therefore be used in endemic regions as a stable alternative diagnosis method, with the added potential for detecting different parasite species.
In the first control experiment, labeled C1, and shown in Fig. 8(a), 250 nM pfLDH solution was added to the non-functionalized sensor. The sensor showed a near-zero spectral shift from the baseline. In the second control experiment, labeled C2, and shown in Fig. 8(b), human LDHA and pfLDH of equal concentration (250 nM), were added to a functionalized sensor, one after the other, with regeneration in between. The sensor responded well to pfLDH with a spectral shift of 5.5 nm, while with hLDHA, the sensor showed a low response below σR, as shown in Fig. 8(c) as column C2. A similar behavior for the control experiments was observed for the transmission drop, as shown in Fig. 8(d).
When the sensor is functionalized, the analytes are closer to the metal surface within the probe depth of the localized SP field. The signal response, R, of the sensor upon analyte adsorption to the immobilized receptor can be approximated as82,96
| δR = SR(naeff − nbsoln)(1 − e−2da/δd)e−2dc/δd, | (9) |
Control experiment C2 shows that the immobilized p-IgG antibody is more specific to pfLDH than hLDH. For experiments that involve the detection of pfLDH in infected blood, a highly specific plasmodium antibody is important in order to distinguish between hLDH and pfLDH, and minimize significant interference from hLDH. A low affinity and specificity between pfLDH and the p-IgG antibody can lead to incorrect conclusions about the presence or severity of malaria because an increase in hLDH levels (which could occur due to various physiological conditions) might be mistakenly interpreted as an increase in the pfLDH level in affinity-based immunosensing. Therefore, further work on testing the sensor using whole blood lysate will be needed in this regard.
Other proteins present in blood, such as HRP-2, or human immunoglobulins, such as HSA may also interact with the p-IgG antibodies, causing noise in the signal and impacting the sensor performance. A detailed study of non-specific adsorption and noise is a clear direction for future work. However, we believe the present study is an informative first step in this direction.
Furthermore, interference effects from non-specific proteins can be addressed through surface functionalisation strategies.97 In general, such interference effects would impact the sensor by leading to a larger or smaller shift in the resonance peak position depending on the size and binding affinity of the protein. For instance, there may be a high binding affinity for a large non-specific protein. This would cause a large shift in the resonance peak compared to pfLDH and statistical fluctuations could mask the contribution of pfLDH to the shift. On the other hand, there may be a low binding affinity for a small non-specific protein, which would have only a small impact on the shift of the resonance peak. Various surface functionalisation strategies can be used to minimise false positives from binding of non-specific proteins. For example, one approach is to immobilise highly specific antibodies (or aptamers) on the sensor surface and ensure they have a uniform surface coverage during the immobilisation stage. A carefully deposited protein A/G layer can also help ensure that the antigen-binding sites of the antibody are accessible. One could also apply a blocking/anti-fouling layer to minimise non-specific adsorption, for instance using HSA or casein.
000 parasites per µL), and the concentration of pLDH can increase substantially, reaching 150 ng mL−1 or higher.90,92,100 This escalation occurs as the enzyme is released during the maturation of the parasite and the rupture of schizonts.
Our LOD of 1.3 nM (45.6 ng mL−1) exceeds early-stage thresholds, however it reliably detects symptomatic (1000 parasites per µL) and severe cases (10
000 parasites per µL), potentially supporting clinical use in endemic areas alongside more costly microscope imaging methods and PCR testing (which achieves an LOD of ≤0.1 parasites per µL (ref. 101)). It should be mentioned that many infections (especially in endemic areas) are low-density (<100 parasites per µL) or even sub-microscopic (<10 parasites per µL), and these provide a reservoir for the disease to spread. More work is needed to improve the LOD of our sensor to achieve this level of detection and compete with microscope imaging methods and PCR testing. Furthermore, additional work on testing the sensor using whole blood lysate is needed to assess whether the LOD is sufficient for clinical deployment.
Among the different types of optical biosensors, plasmonic sensors have shown experimentally the possibility of detecting low concentrations of malaria biomarkers, such as pLDH spiked in buffer solution, or whole blood lysate. The best achieved LOD so far ranges from fM to pM based on a plasmon-enhanced fluorescence immunosensor. However, the achieved LOD based on fluorescence requires expensive equipment to detect the low light level of the fluorescence tags. On the other hand, for the SPR setup, the majority of demonstrated malaria plasmonic biosensors have been fabricated using gold and target pfHRP-2 as the malaria biomarker. The excellent plasmonic properties of gold – low optical losses in the visible and near-infrared regions and its high chemical stability are counteracted by its high cost, which limits large-scale commercialization. An attractive alternative to gold is aluminum. Aluminum is easy to fabricate and functionalize, and has properties that enable plasmon resonances in a broad optical band. Nano-engineered aluminum surfaces, such as the one studied in this work, have previously been proposed for use in various other biosensing applications.40,57,58
We have shown that a low LOD is achievable using an aluminum metasurface as a plasmonic malaria sensor. The LOD of 1.3 nM, achieved using the Al-NHA sensor, is better than the previously reported LOD of 23.5 nM achieved using a gold-NHA.28 Our results may encourage the design of cost-effective malaria sensors based on aluminum plasmonics for detecting the pLDH protein in real blood samples.105,106 Due to the similarity in amino acid sequences among plasmodium species, it has been shown that monoclonal antibodies that target pfLDH can also detect P. vivax and P. knowlesi.85 Therefore, the sensor could potentially be used to detect any species' pLDH for biochemical research and point-of-care in the clinical field.
Furthermore, the surface chemistry using an epoxy-silane linking protocol followed in this study is simple and effective. Both the Al-NHA and the surface chemistry developed are stable in liquid environments and can be used for a long time without degradation in sensor properties. Non-specific adsorption noise was minimized via protein A orientation and 3-GPS silanization, reducing false positives compared to direct IgG immobilization.
On one hand, oriented antibody immobilization via protein A can be considered to be undesirable for sensitivity, as it causes an attenuation in the plasmonic field at the location of the biomarker (due to an increase in the distance of the biomarker from the metal surface), however this is balanced by substantial improvements in binding capacity and selectivity. Previous studies have reported over a 50% enhancement in plasmonic sensing performance when using protein A, with net sensitivity improvements and a 1.5-fold increase in the detection limit.107,108 While we did not explicitly check the impact of the protein A layer in our experiment, we expect a similar behavior to these studies. In general, the orientation of antibodies via an intermediate layer, such as protein A, is of crucial importance in many diagnostic devices for reducing the LOD and improving specificity. We evaluated the specificity of the IgG antibody using human LDH in our control experiments. Control experiment C2 shows that the immobilized p-IgG antibody is far more specific to pfLDH than hLDH (non-specific adsorption noise).
For clinical validation, further tests are needed for studying other proteins present in blood that might also interact with the immobilized IgG antibodies, including a detailed study of non-specific adsorption in a real blood sample. The best case scenario is to use a low KD (high binding affinity) antibody,85,109 aptamer29,104,110 or other biorecognition chemistry to minimize non-specific binding, and improve selectivity and regeneration. Aptamers in particular offer excellent prospects for achieving high binding affinities leading to ultra-low LODs (<30 fM),29,104 although surface functionalization is more involved and expensive imaging equipment may be required.
Another aspect of further study is the relation between the sensitivity and signal-to-noise (SNR) ratio of the sensor. In principle they are unrelated, however, for our sensor, the sensitivity depends on the NHA geometry and the spatial extent of the field in the sensing medium, while the SNR also depends on the NHA geometry, as the signal value (i.e., transmitted intensity) is determined by the transmission efficiency through the NHA, and a low signal value is more susceptible to other technical sources of noise. The relation between the sensitivity and SNR is therefore complicated and trade-offs need to be carefully assessed throughout the design, simulation and testing stages for any new version of the sensor.
In the future, we also plan to test the sensor using intensity interrogation with a stable narrow bandwidth laser in the 650–670 nm range to enhance the overall sensitivity and reduce noise. In addition, the sensor's LOD may be improved by using more specialised antibodies with lower KD values.85,109 Another direction to improve the LOD would be to replace the classical source of light with alternative quantum light sources111 that could offer an improved LOD due to a decrease in shot noise.112
The top domain was defined as the analyte layer (refractive index na = 1.335 for PBS), the bottom as the glass substrate (ns = 1.52), and the middle as the aluminum film perforated with sub-wavelength holes (thickness t ≈ 150 nm, period a0 = 450 nm, hole diameter d ≈ 250 nm). The frequency-dependent permittivity of aluminum (εm) was incorporated using the Drude–Lorentz model from Rakic et al.77 A normal-incidence TM-polarized plane wave was used as the optical excitation from the substrate side, with wavelengths scanned from 450–900 nm. To prevent numerical reflections, perfectly matched layers (PML) terminated the top and bottom domains. The mesh consisted of tetrahedral elements with a maximum size of λ/10 (where λ is the wavelength) near the metal–dielectric interfaces for numerical accuracy. Free tetrahedral meshing is used for domains, with free triangular meshing for periodic boundaries. A fine mesh balances computational efficiency and accuracy. Electric field distributions were computed at key resonance peaks (e.g., 545 nm in air, 665 nm in PBS, 763 nm at the interband transition) by solving the time-harmonic Maxwell's equations using FEM, yielding the spatial distribution of the electric field vector, and normalized as |E|/|E0|, where E0 is the incident field amplitude.
![]() | ||
| Fig. 11 Sensor functionalization protocol. (1) The SiO2 passivated Al-NHA in PBS. (2) The Al-NHA is cleaned in toluene to remove organic contaminants. (3) O2 plasma treatment to increase the abundance of hydroxyl group –OH. (4) 3-GPS incubation. The Al-NHA was incubated in 1% concentration of 3-GPS in toluene to allow the conversion of a silanol-terminated surface to an alkylsiloxy-terminated surface, i.e. epoxide terminated surface. (5) The Al-NHA is rinsed in toluene and placed in an oven at 130 °C. (6) Protein A is attached to the surface via an amine bond. (7) The epoxide group reacts with amine nucleophiles of protein A. (8) The sensor is rinsed with PBS, and p-IgG solution is added. (9) Protein A binds the Fc regions of the p-IgG, exposing the Fab binding sites for the pLDH protein to bind. Red numbers represent stages where spectra were measured and the corresponding spectra (normalized to the white light spectrum) are shown in Fig. 5 of the main text. | ||
The Al-NHA is first cleaned in toluene and hydroxylated (O2-plasma treatment) to ensure an abundance of reactive –OH groups on the silica surface. The hydroxylated Al-NHA is then incubated for 30 minutes in 1% (v/v) 3-GPS solution prepared in toluene. Surface silanol groups of the SiO2 layer react with the 3-GPS silane (alkoxy or chlorine) group, forming a Si–O–Si bond and releasing methanol as a byproduct.67,68 This process is called silanization, i.e. the conversion of a silanol-terminated surface to an epoxy-terminated surface.45,114 The silanization process was enhanced by applying heat (130 °C) that accelerates the formation of the Si–O–Si bonds and helps in the removal of the methanol by-product. 3-GPS monolayer coatings (0.8–1.2 nm thickness) are stable in liquid environments because the epoxy group provides better protection against hydrolysis and degradation.67,68
The Si–O–Si bond anchors the 3-GPS molecules onto the silica surface. The epoxy ring at the end of the 3-GPS molecule provides stronger covalent bonds when attaching an amine-containing biomolecule like protein A. The pfLDH antibodies (p-IgG) conjugation protocol followed in this study was adapted from ref. 27 and 115. It involves: (i) protein A attachment to the sensor surface. Protein A is anchored to the sensor through amine bonding with the epoxy ring of the 3-GPS. (ii) The p-IgG antibodies are then immobilized on the sensor through protein A. The p-IgG antibody solution was prepared from a mouse anti-plasmodium species LDH (mouse IgG1, clone M301, from the Native Antigen Company), 90% pure by SDS-PAGE and was presented in phosphate-buffered saline, pH 7.3 with 0.05% sodium azide. The protein A-coated-Al-NHA was incubated in a 50 µg per mL p-IgG solution prepared in PBS for 4 hours at room temperature. More details about the protocol applied in this work are given in ref. 67 and 68.