Open Access Article
Songül Ulusoy*a,
Şule İrem Altunbaşb,
Aslıhan Gürbüzerc,
Ümmügülsüm Polatb and
Halil İbrahim Ulusoy
b
aDepartment of Pharmacy, Vocational School of Health Service, Sivas Cumhuriyet University, Sivas, Türkiye. E-mail: songululusoy@cumhuriyet.edu.tr
bDepartment of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas, Türkiye
cDepartment of Plant and Animal Production, Vocational School of Technical Services, Sivas Cumhuriyet University, Sivas, Türkiye
First published on 26th February 2026
A highly selective and sensitive analytical strategy was established for the trace quantification of two oral antidiabetic drugs, gliclazide (GLZ) and glimepiride (GLM). The procedure integrates magnetic solid-phase extraction (MSPE) with high-performance liquid chromatography coupled to diode array detection (HPLC-DAD). In this approach, a newly engineered magnetic-aminopropyltriethoxysilane-sulfanilamide (Fe3O4@APTES-sulfanilamide) was synthesized and utilized as an innovative adsorbent. Sulfanilamide as a functional molecule on the surface has been used for the first time in this study. The hybrid structure, consisting of a Fe3O4 magnetic core and a sulfanilamide-functionalized silane shell, provides strong binding affinity toward sulfonylurea compounds through synergistic hydrogen bonding and π–π interactions. Optimization studies were carried out to achieve the best extraction efficiency by adjusting experimental variables such as solution pH, adsorption and desorption times, and solvent composition. Under the final working conditions (pH 6.0; desorption with an acetonitrile–methanol mixture), both target analytes were effectively preconcentrated prior to chromatographic determination. Separation was accomplished using an isocratic elution system containing 10% methanol, 40% phosphate buffer (pH 3.0), and 50% acetonitrile, with UV detection at 219 and 256 nm. The developed protocol demonstrated excellent linearity, remarkable enrichment factors, and very low detection limits. Precision studies yielded RSD values below 3.5% (n = 3, 100 ng mL−1). The reliability of the proposed method was further validated by its successful application to both synthetic and human urine samples, giving satisfactory recovery results. This newly designed Fe3O4@APTES-sulfanilamide -based MSPE coupled with HPLC-DAD provides a robust, time-efficient, and eco-friendly platform for the determination of trace oral antidiabetic drugs in complex biological matrices.
Sulfonylureas constitute one of the most widely prescribed classes of oral antidiabetic drugs for the management of Type II diabetes mellitus. These agents act primarily as insulin secretagogues by stimulating pancreatic β-cells, thereby enhancing endogenous insulin release. Among them, gliclazide and glimepiride are prominent second-generation sulfonylureas, offering improved potency, selectivity, and pharmacokinetic profiles compared with earlier derivatives.6–8 In addition to their pancreatic effects, these drugs have been reported to exert extra-pancreatic actions, including enhancement of peripheral insulin sensitivity and facilitation of glucose uptake in target tissues.9,10 Owing to their widespread clinical use and pharmacological significance, reliable analytical methods are required for their determination in pharmaceutical formulations and biological matrices.
Several analytical approaches have been reported for the determination of sulfonylurea drugs, including spectrophotometry,11 capillary electrophoresis,12 and chromatographic techniques such as HPLC-UV,13 HPLC-PDA,14 and LC-MS/MS.15 While these methods provide acceptable sensitivity and selectivity, many of them require extensive sample preparation, large solvent consumption, or sophisticated instrumentation. In particular, the direct analysis of biological matrices remains challenging due to matrix interferences, low analyte concentrations, and inadequate preconcentration capability. These limitations highlight the need for selective, efficient, and environmentally sustainable sample preparation strategies prior to chromatographic determination.
Solid-phase extraction (SPE) is a widely applied sample preparation technique that offers numerous advantages, including methodological flexibility and compatibility with a wide range of adsorbent materials. Compared to liquid–liquid extraction, the SPE approach requires smaller volumes of organic solvents and shorter processing times, thereby making it more environmentally sustainable and operationally efficient.16,17 Furthermore, the use of minimal quantities of sorbent materials allows for higher recovery rates and enrichment factors. The two commonly employed SPE configurations are batch and column techniques.18–21 In recent years, magnetic nanoparticles (MNPs) have gained significant attention as sorbent materials in SPE applications due to their distinctive physicochemical characteristics.22 Owing to their exceptionally large surface area, magnetic nanoparticles typically exhibit high adsorption capacities toward target analytes. Moreover, their surfaces can be readily functionalized with specific ligands, enabling selective interaction and binding with target molecules within complex sample matrices.23,24
A notable advantage of MNP-based extraction lies in their facile separation from aqueous media under the influence of an external magnetic field, eliminating the need for conventional filtration or centrifugation steps. Unlike traditional solid-phase microextraction, magnetic solid-phase extraction (MSPE) does not require the use of packed columns, thereby circumventing the operational difficulties associated with sorbent loading, replacement, and desorption.25,26 The surfaces of magnetic sorbents can be modified depending on the molecular structure of target molecules. In this way, the surface of the nanoparticles becomes more compatible with the target molecules. Depending on the chemical structure of the molecule used in the surface coating, nanoparticles can be endowed with hydrophilic, hydrophobic, negatively charged, or positively charged characteristics. Scientists around the world conducting research in this field are carrying out numerous studies aimed at developing novel and functional materials.27–29 Our research group also has published several articles on this subject.30–33 In the present study, the surface modification of magnetic nanoparticles was performed using a sulfanilamide molecule. Although sulfanilamide is conventionally known as an antibiotic compound, its ideal molecular structure provided a favorable interaction platform for the target drug molecules. The ability of structurally similar molecules to bind to silanized groups is well documented and supported by the literature.34,35 Following extraction, magnetic nanoparticles can be completely isolated from the solution using a simple external magnet, which significantly simplifies the analytical workflow. Furthermore, due to their reusable and recyclable nature, magnetic nanoparticles represent a cost-effective and environmentally sustainable alternative for modern analytical separation processes.
Surface functionalization using APTES represents one of the most employed silanization strategies for magnetic nanoparticles due to its chemical stability and ease of modification. However, APTES alone primarily serves as a linker layer rather than a selective recognition interface. In the present study, this conventional platform was further engineered through the immobilization of sulfanilamide moieties. The rationale behind this design lies in the structural similarity and complementary interaction potential between sulfanilamide functional groups and sulfonylurea antidiabetic drugs, enabling enhanced hydrogen bonding, dipole–dipole, and π–π interactions. To the best of our knowledge, the use of sulfanilamide-functionalized Fe3O4@APTES magnetic nanoparticles as a selective MSPE sorbent for gliclazide and glimepiride has not been previously documented, thereby providing a new molecularly oriented extraction approach.
The distinctive aspect of this study lies in the design and synthesis of a novel Fe3O4@APTES-sulfanilamide magnetic nanocomposite, which has not been previously reported as a sorbent for sulfonylurea-type oral antidiabetic drugs. The material provides enhanced selectivity and extraction efficiency due to the synergistic interactions between sulfanilamide functional groups and the target analytes. Integrating this innovative sorbent into an MSPE–HPLC-DAD platform offers a rapid, sensitive, and eco-friendly analytical approach suitable for trace-level monitoring of antidiabetic agents in complex biological matrices.
Chromatography-grade solvents, including methanol and acetonitrile, were also supplied by Sigma-Aldrich (St. Louis, MO, USA). Britton–Robinson (BR) buffer solutions covering the pH range of 2.0–10.0 were freshly prepared from a 0.02 M mixed acid solution consisting of boric, phosphoric, and acetic acids. The required pH values were adjusted by the gradual addition of 0.1 M sodium hydroxide while continuously monitoring with a calibrated pH meter. Stock standard solutions of gliclazide (GLZ) and glimepiride (GLM) were prepared at concentrations of 1000 µg mL−1 in analytical-grade methanol (Sigma-Aldrich). These solutions were kept in amber glass vials at +4 °C to prevent degradation due to light exposure.
Chromatographic analyses were performed on a Shimadzu LC-20AD high-performance liquid chromatography (HPLC) system (Shimadzu, Tokyo, Japan) equipped with a photodiode array (PDA) detector (SPD-M20A), an autosampler (SIL-20AC), a column oven (CTO-10AS), and a high-pressure pump (LC-20AD). Data acquisition, processing, and integration were managed using the LC Solution software (Shimadzu), allowing for precise control of experimental conditions and real-time monitoring of chromatographic performance.
| Parameter | Value |
|---|---|
| HPLC mode | Isocratic |
| Eluent | 10% methyl alcohol |
| 40% (0.02 M KH2PO4, pH 3.0) | |
| 50% acetonitrile | |
| Eluent flow rate | 1.0 mL min−1 |
| Run time | 14 min |
| Column | Phenomex C-18 (150 × 5 mm, 5 μm) |
| Column temperature | 45 °C |
| Injection volume | 10 μL |
For surface functionalization, 2 g of the dried Fe3O4 nanoparticles were dispersed in 50 mL of water
:
ethanol(1
:
1), followed by the addition of 3 mL of concentrated ammonia and 2 mL of (3-aminopropyl)triethoxysilane (APTES). Building on previous experimental findings and literature reports, further modification was performed to enhance the nanoparticles’ affinity toward the target analytes. Specifically, 250 mg of sulfanilamide dissolved in 50 mL of ethanol was added, and the mixture was stirred at room temperature for 6 hours. The resulting functionalized nanoparticles were then repeatedly washed with an ethanol/water mixture and dried under ambient conditions.
After the adsorption period, the tubes were positioned within an external magnetic holder to separate the aqueous phase, which was carefully removed using a pipette. Desorption of the retained analytes was performed by adding 500 μL of a mixture of acetonitrile
:
methanol (1
:
1) to each tube, followed by 60 seconds of vortexing. The resulting solution containing the eluted analytes was collected under the magnetic field using a syringe, filtered through a 0.45 μm PTFE syringe filter, and transferred into HPLC vials. The enriched samples of GLZ and GLM were subsequently subjected to HPLC analysis under the previously optimized chromatographic conditions.
The interaction mechanism between GLZ/GLM and the Fe3O4@APTES-sulfanilamide sorbent can be attributed to the presence of multiple surface functional groups introduced by APTES and sulfanilamide. The amine groups from APTES and the sulfonamide moieties on the surface can establish hydrogen bonding and electrostatic interactions with functional groups (e.g., carbonyl and sulfonyl) present in the analytes. The aromatic ring of sulfanilamide may also contribute via π–π stacking with the aromatic regions of GLZ and GLM, enhancing interaction strength. Previous studies on amine-functionalized silica/magnetic adsorbents have reported that amino groups significantly influence adsorption behavior through electrostatic attraction and hydrogen bonds between surface –NH2 and analyte molecules (e.g., adsorption of organic contaminants onto APTES-modified magnetic silica nanoparticles)42 and similar sulfanilamide-functionalized magnetic nanoparticles have been effectively prepared and characterized to interact with target species through surface functional groups, demonstrating the role of covalently attached organic moieties in binding performance.43 These combined interactions explain the high extraction efficiency and selectivity observed in the present study.
N stretching vibrations, indicating the interaction between the amine and sulfanilamide functionalities. The strong bands detected in the range of 1100–1000 cm−1 are characteristic of Si–O–Si and Si–O–Fe linkages, confirming that APTES molecules were covalently bonded to the Fe3O4 surface through silanol condensation.47 Moreover, the absorption at 1150–1200 cm−1 is assigned to the S
O stretching vibration of sulfanilamide groups, validating the successful immobilization of sulfanilamide moieties on the APTES-modified magnetic nanoparticles.48 These findings collectively confirm that the surface modification process was effectively accomplished without altering the magnetic core structure of Fe3O4.
The XRD patterns of pure Fe3O4 and surface-functionalized Fe3O4@APTESsulfanilamide nanoparticles are shown in Fig. 2. Both samples exhibit characteristic diffraction peaks at approximately 2θ = 30.2°, 35.5°, 43.2°, 53.5°, 57.1°, and 62.7°, corresponding to the (220), (311), (400), (422), (511), and (440) crystallographic planes of the cubic spinel structure of magnetite (JCPDS card No. 19-0629). These reflections confirm that the magnetic core retains its crystalline nature following surface modification.49 A slight decrease in peak intensity and a marginal broadening of the diffraction lines are observed for Fe3O4@APTESsulfanilamide compared to those of bare Fe3O4, which can be attributed to the formation of an amorphous organosilane layer surrounding the magnetic nanoparticles and to a partial reduction in coherent crystallite size. The absence of additional diffraction peaks indicates that neither APTES functionalization nor sulfanilamide grafting was induced any phase transformation or impurity formation in the magnetite structure.
The surface morphology of the pristine and functionalized magnetite nanoparticles was examined by scanning electron microscopy (SEM), as shown in Fig. 3. The pristine Fe3O4 nanoparticles (Fig. 3A) exhibit a nearly spherical morphology with a uniform distribution and a tendency to form compact agglomerates due to the high surface energy and magnetic dipole–dipole interactions between individual particles. In contrast, the Fe3O4@APTESsulfanilamide nanocomposite (Fig. 3B) displays a slightly rougher and more irregular surface texture, which can be attributed to the successful coating of APTES and subsequent immobilization of sulfanilamide groups on the nanoparticle surface. The presence of a thin organic layer and the increased particle clustering are consistent with the formation of a surface-modified shell around the magnetic core, without significant alteration of the overall morphology. These morphological observations support the FTIR and XRD results, confirming the effective surface functionalization of Fe3O4 nanoparticles while preserving their nanostructured integrity.
As illustrated in Fig. 4, the extraction efficiency exhibited a pronounced dependence on the solution pH. The optimal enrichment was achieved at pH 6.0, where the balance between the surface charge of the magnetic nanoparticles and the ionization state of the analytes favored maximum adsorption. Considering the pKa values of gliclazide (≈5.8)50 and glimepiride (≈6.2),51 both compounds exist predominantly in their neutral or partially deprotonated forms at pH 6.0, which promotes hydrophobic and hydrogen-bonding interactions with the functional groups present on the nanoparticle surface. At lower pH values (<4), protonation of the surface –NH2 and –OH groups leads to increased electrostatic repulsion and reduced analyte affinity, while at higher pH (>8), excessive deprotonation diminishes the availability of active binding sites and weakens interaction strength.52,53
Therefore, pH 6.0 was selected as the optimal condition for subsequent enrichment experiments, ensuring a favorable electrostatic environment and efficient mass transfer between the magnetic sorbent and the oral antidiabetic drug molecules.
This behavior suggests that the interaction between the analytes and the Fe3O4@APTES-sulfanilamide surface is primarily governed by a combination of electrostatic and hydrogen-bonding interactions, reaching equilibrium within a moderate time frame. Accordingly, 50 minutes was selected as the optimal adsorption time for subsequent enrichment experiments.
To assess the effect of the solvent type on desorption efficiency, a series of experiments was conducted using ten parallel samples under identical conditions, varying only the solvent composition. The solvents evaluated included distilled water, methanol, acetonitrile, ethanol, isopropanol, n-hexane, acetone, pH 6.0 Britton–Robinson buffer, and a 1
:
1 (v/v) acetonitrile–methanol mixture. Following the adsorption of GLZ and GLM onto the Fe3O4@APTES-sulfanilamide sorbent, each solvent was tested as an eluting phase under otherwise identical conditions. As illustrated in Fig. 6, the highest and most distinct chromatographic peaks were obtained when a 1
:
1 (v/v) mixture of acetonitrile and methanol was used as the desorption solvent. This binary solvent system effectively balanced polarity and elution strength, facilitating disruption of hydrogen-bonding and van der Waals interactions between the analytes and the functionalized sorbent surface. Purely aqueous or less polar solvents, such as n-hexane and isopropanol, yielded significantly lower recoveries due to insufficient solvation of the relatively polar sulfonylurea structures of the analytes. Consequently, the 1
:
1 acetonitrile–methanol mixture was selected as the optimal desorption medium for all subsequent enrichment and analytical experiments, providing both high recovery and sharp chromatographic peak resolution.
In addition to the solvent type, the desorption solvent volume plays a decisive role in determining the overall recovery of analytes from the magnetic sorbent surface. An insufficient solvent volume may not fully wet and penetrate the sorbent matrix, resulting in incomplete elution of adsorbed analytes. Conversely, an excessively large volume can lead to sample dilution, reducing preconcentration efficiency and thereby lowering chromatographic peak intensity. To establish the optimal desorption volume, a series of experiments was performed using the previously optimized 1
:
1 (v/v) acetonitrile–methanol mixture as the eluent. The desorption volume was varied between 200 and 1500 µL, while maintaining all other parameters constant, including adsorption time, sorbent mass, and desorption time.
As shown in Fig. 7, analyte peak areas initially increased with increasing solvent volume, reflecting improved wetting and diffusion into the sorbent structure. Maximum signal intensity and recovery for both GLZ and GLM were achieved at a desorption volume of 600 µL, indicating efficient disruption of analyte–sorbent interactions and complete transfer of analytes into the liquid phase. Beyond this volume, peak areas exhibited a pronounced decline due to the dilution effect. Therefore, 600 µL of the 1
:
1 acetonitrile–methanol mixture was selected as the optimal desorption solvent volume for subsequent experiments, providing the best balance between elution efficiency and enrichment factor.
![]() | ||
| Fig. 8 Chromatograms of gliclazide and glimepiride molecules (250 ng mL−1) obtained under ideal conditions after MSPE. | ||
Once the MSPE parameters were optimized, the analytical validation of the developed method was systematically performed in accordance with the International Council for Harmonization (ICH) guidelines for analytical procedure validation.54 The validation process included the evaluation of linearity, accuracy (recovery), precision (expressed as %RSD), limit of detection (LOD), and limit of quantification (LOQ). The analytical performance data obtained for GLZ and GLM under the optimized conditions are summarized in Table 2. For comparison purposes, a direct analytical procedure without the MSPE step was performed. Standard and sample solutions were prepared at the same concentration levels and directly injected into the HPLC system under the optimized chromatographic conditions described above. No preconcentration or extraction step was applied. The obtained peak areas were used to evaluate the enhancement effect of the MSPE procedure by comparing signal intensities and sensitivity parameters.
| Parameter | Without MSPE method | With MSPE method | ||
|---|---|---|---|---|
| GLZ | GLM | GLZ | GLM | |
| a It was calculated as stated in the ICH guidelines source.b Pre-concentration factor; it was calculated by taking the ratio of the initial aqueous phase volume (50 mL) to the volume obtained after enrichment (0.6 mL).c The enhancement factor was determined by dividing the slope of the calibration curve obtained using the MSPE method by that of the calibration curve obtained without MSPE. | ||||
| Linear range | 1.0–20.0 μg mL−1 | 1.0–20.0 μg mL−1 | 10.0–900.0 ng mL−1 | 10.0–900.0 ng mL−1 |
| LODa | 0.32 μg mL−1 | 0.38 μg mL−1 | 3.58 ng mL−1 | 3.63 ng mL−1 |
| LOQa | 0.85 μg mL−1 | 0.92 μg mL−1 | 9.85 ng mL−1 | 9.78 ng mL−1 |
| RSD (%) | 5.30 | 7.09 | 5.2 | 6.5 |
| Calibration sensitivity | 24.3 | 36.8 | 2063.1 | 3510.7 |
| Correlation coefficient (R2) | 0.9985 | 0.9890 | 0.9901 | 0.9948 |
| Pre-concentration factorb | — | — | 83.3 | 83.3 |
| Enhancement factorc | — | — | 84.9 | 95.4 |
As described earlier, the chromatographic method was initially optimized using model solutions prior to its coupling with the MSPE procedure, allowing for a comparative assessment of analytical performance before and after enrichment. The application of MSPE significantly improved the method's sensitivity, extending its quantification capability from the microgram to the nanogram per milliliter range. Calibration curves were established by applying the developed method to standard solutions containing increasing concentrations of the analytes under optimized conditions. The plots of peak area versus analyte concentration yielded linear regression equations, from which the slope, intercept, and correlation coefficient (R2) were calculated to confirm linearity. The results demonstrated a clear linear relationship between the analyte concentration and detector response within the range of 10.0–900.0 ng mL−1 for both drugs. Representative calibration plots for GLZ and GLM are presented in Fig. 9.
The LOD represents the lowest concentration at which the analyte can be confidently detected but not necessarily quantified, while the LOQ denotes the lowest concentration that can be determined with acceptable precision and accuracy. The data indicate that, following enrichment, the signal intensities increased proportionally with concentration, confirming both the efficiency of the preconcentration procedure and the reliability of the HPLC-DAD measurements.
Three different concentration levels of standards (200 and 400 ng mL−1) were spiked into synthetic and human urine samples separately, and recovery experiments were conducted using these samples (Table 3). Recovery values were obtained in the range of 98.1–102.2% while RSD values were lower than 5.3%. The application of the developed method to spiked and real urine samples yielded satisfactory recoveries, with the quantitative results provided in Table 3, demonstrating the suitability of the method for practical biological sample analysis.
| Examples | Added ng mL−1 | Founda (ng mL−1) | RSD % | Recovery % | |||
|---|---|---|---|---|---|---|---|
| GLZ | GLM | GLZ | GLM | GLZ | GLM | ||
| a Mean of 3 repeated measurements ± standard deviation | |||||||
| Synthetic urine | 0.0 | <LOD | <LOD | — | — | — | — |
| 200.0 | 192.4 ± 12.5 | 196.5 ± 10.9 | 6.5 | 5.5 | 96.2 | 98.3 | |
| 400.0 | 412.5 ± 28.4 | 409.5 ± 21.1 | 6.9 | 5.2 | 103.1 | 102.4 | |
| Real urine | 0.0 | <LOD | <LOD | — | — | — | — |
| 200.0 | 202.5 ± 12.4 | 212.6 ± 12.4 | 6.1 | 5.2 | 101.3 | 106.3 | |
| 400.0 | 374.8 ± 19.4 | 391.5 ± 13.2 | 5.8 | 3.4 | 93.7 | 97.9 | |
The obtained validation parameters confirmed that the proposed MSPE–HPLC-DAD method offers high sensitivity, good reproducibility, and excellent applicability for trace-level quantification of GLZ and GLM in complex biological matrices.
Magnetic APTES–sulfanilamide was deliberately designed as a suitable sorbent platform by integrating a versatile silanization layer with a structurally compatible recognition functionality. APTES was employed to introduce surface amine groups onto Fe3O4 nanoparticles, enabling stable covalent immobilization and providing active interaction sites. Subsequent sulfanilamide functionalization was strategically selected due to its structural resemblance to sulfonylurea antidiabetic drugs. The sulfanilamide moiety contains hydrogen bond donor and acceptor sites, polar sulfonyl groups, and aromatic regions capable of establishing multiple intermolecular interactions with target analytes. These include hydrogen bonding, dipole–dipole interactions, and hydrophobic association, collectively enhancing adsorption affinity and extraction selectivity. Compared with conventional magnetic sorbents lacking molecularly compatible ligands, this dual-functional design offers improved recognition capability toward sulfonylurea compounds.
The proposed method demonstrated excellent linearity across the 10.00–900.00 ng mL−1 range, with correlation coefficients (R2) exceeding 0.9901 for both analytes. The limits of detection (LOD) and quantification (LOQ) were substantially improved after MSPE, decreasing from the microgram to nanogram per milliliter level. Precision studies revealed RSD values below 3.5%, confirming the repeatability of the procedure. The method's applicability was further validated using synthetic and real urine samples, yielding satisfactory recoveries and proving its reliability for biological analysis.
In addition to its analytical performance, the proposed MSPE–HPLC-DAD system was evaluated through various Green Analytical Chemistry (GAC) metrics, confirming its compliance with eco-friendly practices due to minimal solvent usage and low waste generation. Overall, this study presents the first reported application of MSPE coupled with HPLC-DAD for the chromatographic determination of GLZ and GLM, offering a robust, low-cost, and green alternative for routine pharmaceutical and bioanalytical applications.
| This journal is © The Royal Society of Chemistry 2026 |