First published on 21st January 2026
Synovial fluid is a clinically valuable biofluid for studying joint diseases through metabolomic analysis. However, given the viscoelastic nature of this biofluid its analysis is challenging. Indeed, the lack of standardised pre-analytical processing protocols for synovial fluid metabolomics potentially introduces significant variability that can compromise data reliability and hinder the application/interpretation of results. This study systematically assesses how common sample handling variables including sample dilution, freeze–thaw cycling, blood staining and viscosity reduction (via hyaluronidase digestion and bead beating) affect the metabolomic profile of synovial fluid. Using a combination of untargeted GC-ToF-MS and UHPLC-MS (in both electrospray ionisation modes; ESI+ and ESI−) for the profiling of both polar and non-polar metabolites, we evaluated changes in detectable metabolite numbers, small molecule class distribution and relative abundances in a collection of synovial fluid samples. Sample dilution had the most pronounced impact on metabolite read-outs, significantly reducing detectable metabolite numbers. Blood staining introduced distinct metabolites and resulted in the artificial increase in the relative abundance of three metabolites including adenine, hypoxanthine and 4-fluoro-DL-tryptophan. Bead beating enhanced the detection of a broad range of lipid species particularly in the UHPLC ESI+ analysis. Freeze–thaw cycling and hyaluronidase treatment had minimal effects on overall metabolite quantities or composition. These findings underscore the importance of optimising and standardising synovial fluid sample handling to ensure reproducibility and to enable accurate interpretation of metabolomic data for the study of disease mechanisms and biomarker discovery.
Collection of human SF can be technically challenging, particularly in the absence of effusion (the abnormal accumulation of fluid). SF is typically collected at the time of surgery or through joint aspiration.11 If effusion is not present and SF volumes are small, various techniques that include lavage/wash-out of the joint have been implemented to acquire a dilute SF sample.12–14
During SF collection and subsequent processing, numerous pre-analytical factors can alter the metabolomic composition, complicating reliable comparison and quantification across samples. There are currently no published standard protocols for the preparation of SF for metabolomic analysis using GC-MS nor LC-MS. SF typically presents as a pale-yellow colour however in some cases it presents with blood staining that could be caused by a range of factors both traumatic (sample aspiration process, surgery, fractures etc.) or non-traumatic (bleeding disorders) and inflammatory processes such as synovitis, which increase synovial membrane permeability allowing cells from the blood to enter the synovial cavity.13,15,16 The presence of blood in SF introduces the risk of altering the metabolite profile due to haemolysis. Haemolysis can result in the release of intracellular metabolites and enzymes such as tryptophan phospholipids from the cellular membrane therefore contaminating the SF.17 In this study, the term blood stained refers to SF samples contaminated with blood that remained visibly red after centrifugation, indicating haemolysis and the release of intracellular contents. This terminology reflects our clinical observations, where haemolytic SF aspirates are occasionally encountered during joint aspiration procedures.
As lavage is often required in the absence of effusion, the collected SF is diluted theoretically resulting in the reduced concentration/loss of metabolites, thus risking analyte signals in the samples approaching or falling below limits of detection when analysed using GC/LC-MS/MS. This makes it difficult to distinguish metabolite signals from background noise making the data unreliable and unreproducible.18 Where SF is not diluted with saline, the volume of sample is limited (median total knee volume = 3.05 mL),19 therefore, the limited availability of the precious clinical samples often necessitates their use in multiple analyses, making freeze–thawing unavoidable. SF is highly viscous, mainly due to high hyaluronan content (1–4 mg mL−1 (ref. 20)), other glycoproteins such as lubricin also contribute to its viscoelastic properties.21 Enzymatic digestion with hyaluronidase is therefore commonly applied to homogenise and reduce the viscosity making the biofluid easier to work with.22 Hyaluronidase treatment has the additional benefit as shown in proteomic studies of improving the detection of immune cells.23,24 However, the benefits/drawbacks of this technique, or other physical methods such as bead beating to reduce viscosity, when applied for the metabolomic profiling of SF using a mass spectrometry approach has not been explored.
The influence on metabolite stability due to pre-analytical sample conditions and handling has been widely explored in various biospecimens including serum, plasma and urine.25–28 Although pre-analytical handling has been estimated to account for up to 80% of experimental irreproducibility29 only a few studies have directly examined how handling and storage conditions influence the stability of metabolites in SF; notably all of which have been measured using NMR. Early NMR-based investigations demonstrated that SF metabolites remain stable under controlled freezing and short-term storage,30 while more recent work has shown that controlled enzymatic and physical processing has limited impact on small-molecule composition.31 Jaggard et al.32 further provided a comprehensive review and experimental evaluation of pre-analytical factors including storage temperature, freeze–thaw cycling, and collection procedures highlighting that although studies have addressed either directly or indirectly these variables, few have quantified their effects systematically.
The present study builds on this evidence by systematically assessing multiple common pre-analytical variables using complementary GC-MS and LC-MS platforms, an approach not previously undertaken. This is important as NMR and MS techniques provide complementary insights into the metabolome: NMR spectroscopy enables quantification of abundant small molecules whereas MS based techniques offer greater sensitivity and coverage of chemically diverse, low abundance metabolites.33,34 Previous investigations on biofluids such as plasma and serum have demonstrated that NMR and MS based metabolomics highlight different aspects of the metabolome in response to pre-analytical handling factors therefore highlighting the need to assess these effects on the SF metabolome using MS based techniques to complement existing knowledge derived primarily from NMR studies.35–38
The condition of the sample as well as its handling, including collection, processing, storage, and preparation, are well-recognised sources responsible for the highest variations observed in metabolomic studies.39 This can significantly impact the accuracy and reliability of downstream GC-MS and LC-MS analyses, potentially leading to misinterpretation of results and inaccurate clinical/scientific conclusions. Therefore, understanding the effects that sample condition has on metabolite stability and optimising sample handling procedures is critical to ensure the integrity and quality of SF samples and to maximise the information obtained from these sophisticated analytical techniques.40
This study aimed to determine how common pre-analytical variables: blood contamination, dilution, freeze–thaw cycles, and viscosity treatments (hyaluronidase digestion and bead beating) influenced the detectable metabolomic profile of SF. We sought to assess changes in both metabolite abundance and class representation using GC-MS and LC-MS/MS platforms.
:
5, 1
:
10 or 1
:
20 ratio. Samples were diluted on ice prior to analysis.
Deproteinisation of the samples was achieved by adding 150 µL of ice-cold acetonitrile/methanol (1
:
1) and vortexing of the sample at maximum speed for 10 s. Samples were then centrifuged at 13
500g for 15 min following which the supernatant was collected. Samples undergoing bead beating were then transferred to vials and subjected to bead beating following which the supernatant was collected. 50 µL of internal standard solution (IS) (1.67 mg mL−1 of each lysine-d4, glycine-d5 and succinic acid-d4 in water) was added to each sample. Samples were lyophilised in a vacuum centrifuge (Savant SpeedVac, SPD130DLX, Savant vapor trap RVT5105, Fisher Scientific, Loughborough, UK) at ambient temperature for 12 h for solvent removal.
Derivatisation of the samples was carried out by the addition of 50 µL O-methoxyamine-HCl in pyridine. Samples were vortexed for 10 s before being incubated at 65 °C for 40 min. 50 µL of N-methyl-N-trimethylsilyl tri fluoroacetamide (MSTFA) was then added to each sample and vortexed for 10 s before further incubation at 65 °C for 40 min. Samples were then centrifuged at 13
500g for 15 min following which 70 µL of the supernatant was collected and transferred to sterile GC glass vials capped with rubber sealed vial caps.
The analysis sequence was led by an extraction blank (50 µL) injection followed by an injection of a retention index (RI) sample (0.3 mg mL−1 of decane, dodecane, pentadecane, nonadecane and docosane in pyridine). This was then followed by six injections of the QC sample to condition the GC column and then every five sample injections were bracketed by one QC injection. Samples were randomly organised between each QC set. The run was ended by another RI sample injection as previously described by Dunn et al.41 Data were collected using an Agilent GC/Q-TOF system with 280 °C inlet temperature, HP-5ms (30 m × 0.25 mm × 0.25 µm) capillary column (Agilent, Cheadle, UK), oven temperature gradient 70 °C, 4 min hold, 20 °C min−1 to 300 °C, 4 min hold, 300 °C transfer line temperature. Samples were run with a helium carrier gas flow rate of 1 mL min−1 in a constant flow mode.
:
1.8 v/v LC-MS grade MeOH/H2O (−48 °C) and vortexed for 10 s. 517 µL of LC-MS grade CHCl3 was then added and samples were vortexed for 1 min before centrifugation. Where appropriate, samples underwent bead beating at this point following which the supernatant was collected in Eppendorf tubes. All samples were centrifuged for 15 min at 17
000g at 4 °C. Following phase separation, defined aliquots were taken from each layer prior to drying: 300 µL from the lipid (organic) phase, 600 µL from the polar (aqueous) phase, and, due to lower recovery, 100 µL from the lipid phase of bead-beaten samples, avoiding the uptake of any sediment from the interphase. These aliquots were transferred to separate 2 mL Eppendorf tubes and dried overnight in a vacuum centrifuge (Scan Speed 40 Vacuum Concentrator, Labogene) at ambient temperature for solvent removal, prior to being placed in a −80 °C freezer for storage until analysis. Extraction blanks were prepared and processed according to the full extraction workflow.
Prior to UHPLC–MS analysis, all samples were reconstituted in 150 µL of the appropriate starting solvent on ice, as detailed in the UHPLC–MS assay descriptions below. Following reconstitution, samples were vortexed for 30 s followed by centrifugation (17
000g, 4 °C, 15 min). From each sample, 40 µL was then transferred into two sterile 300 µL insert glass vials. A pooled QC sample was then created by aliquoting 40 µL from each sample to monitor instrument variability. Due to the low recovery volume for samples following bead beating, only 100 µL could be recovered from the lipid phase samples that were subjected to bead beating, therefore following reconstitution 30 µL of the lipid phase was transferred to four sterile 300 µL insert glass vials with a further 30 µL being used for the pool QC. All samples were analysed separately in positive and negative ion modes using a Q Exactive Quadrupole-Orbitrap instrument (Thermo Scientific) in conjunction with a Vanquish UHPLC system. Data were acquired at a mass resolution of 70
000 (FWHM at m/z 200), with the AGC target set at 106. The samples were analysed via two separate assays (assay 1 and assay 2). All assays were 15 min in length. Assay 1 was a lipidomic assay and assay 2 was a hydrophilic interaction chromatography (HILIC) assay. Assay 1 samples were reconstituted using 150 µL of H2O: isopropyl alcohol (1
:
3) on ice and assay 2 samples were reconstituted in 150 µL of H2O
:
Acetonitrile
:
Methanol (1
:
1
:
1) solution on ice. Assay 1 used a Thermo Scientific Hypersil Gold 100 × 2.1 mm, 1.9 µm particle size column (part 25
002–102
130) with a gradient mobile phase flow rate of 0.4 mL min−1; mobile phase A (60% acetonitrile, 10mM ammonium formate, 0.1% formic acid) and mobile phase B (85.5% IPA, 9.5% ACN, 5% water, 10mM ammonium formate, 0.1% formic acid). The 15 min gradient applied was as follows: 0 min, 20% B; 1.6 min, 20% B; 9.4 min, 100% B; 10.6 min, 100% B; 12.6 min, 20% B; 15 min, 20% B. An injection volume of 4 µL and a m/z range of 150–2000 Da was applied.
Assay 2 used a Thermo Scientific Accucore-150-Amide-HILIC 100 × 2.1 mm, 2.6 µm particle size column (part 16
726–102
130) with a flow rate of 0.5 mL min−1 and two mobile phases; mobile phase A (positive ion mode: 95% ACN, 10 mM ammonium formate, 0.1% formic acid; negative ion mode: 95% ACN, 10 mM ammonium acetate, 0.1% acetic acid) and mobile phase B (positive ion mode: 50% ACN, 10 mM ammonium formate, 0.1% formic acid; negative ion mode: 50% ACN, 10 mM ammonium acetate, 0.1% acetic acid). The 15 min gradient applied was as follows: 0 min, 20% B; 1.6 min, 20% B; 9.4 min, 100% B; 10.6 min, 100% B; 12.6 min, 20% B; 15 min, 20% B. An injection volume of 4 µL and a m/z range of 150–2000 Da was applied. Within an assay, the sample injection was randomised, with QC injections made after every fifth sample injection. Each run started with a solvent blank injection followed by three QC injections followed by an extraction blank injection then an additional 7 QC injections. Runs were terminated with a QC injection followed by an extraction blank injection.
:
5, 1
:
10, 1
:
20) were compared to expected dilution factors. For each metabolite, log10 intensity was regressed against log10 dilution factor to obtain an R2 measure of linearity. Mean observed log2 fold changes were also plotted against expected values, and representative metabolite response curves were generated with theoretical linear fits (SI Fig. S2).
| Chemical class | Control | 1 : 5 dilution |
1 : 10 dilution |
1 : 20 dilution |
2× freeze–thaw | 3× freeze–thaw | Blood staining | Hyaluronidase treatment | Bead beating |
|---|---|---|---|---|---|---|---|---|---|
| Alkyl halides | 0 | 1 | 0 | 0 | 0 | 1 | 0 | 0 | 1 |
| Anthracenes | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
| Azoles | 2 | 0 | 0 | 0 | 1 | 0 | 1 | 1 | 1 |
| Azolidines | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Azolines | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 |
| Benzene and substituted derivatives | 10 | 7 | 3 | 3 | 10 | 8 | 7 | 6 | 2 |
| Benzothiophenes | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 |
| Benzotriazoles | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 0 |
| Carboxylic acids and derivatives | 30 | 18 | 13 | 8 | 27 | 28 | 34 | 34 | 14 |
| Diazanaphthalenes | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 |
| Diazines | 0 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 0 |
| Dihydrofurans | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 |
| Dioxanes | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 |
| Dithioles | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 |
| Epoxides | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 |
| Fatty Acyls | 7 | 2 | 1 | 3 | 9 | 11 | 11 | 11 | 1 |
| Furans | 1 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 0 |
| Glycerolipids | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 0 | 0 |
| Halogen organides | 0 | 1 | 1 | 0 | 0 | 0 | 1 | 0 | 0 |
| Homogeneous alkali metal compounds | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 |
| Hydroxy acids and derivatives | 5 | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 |
| Imidazopyrimidines | 4 | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 2 |
| Indanes | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 |
| Indoles and derivatives | 2 | 0 | 1 | 1 | 1 | 0 | 1 | 0 | 2 |
| Keto acids and derivatives | 4 | 0 | 0 | 0 | 4 | 5 | 3 | 5 | 3 |
| Lactones | 3 | 2 | 4 | 1 | 3 | 2 | 4 | 4 | 1 |
| Naphthalenes | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Organic carbonic acids and derivatives | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 |
| Organic disulfides | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Organic phosphoric acids and derivatives | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 |
| Organometalloid compounds | 2 | 6 | 4 | 2 | 6 | 3 | 5 | 3 | 8 |
| Organonitrogen compounds | 3 | 0 | 0 | 2 | 3 | 3 | 2 | 2 | 0 |
| Organooxygen compounds | 25 | 14 | 18 | 14 | 22 | 18 | 30 | 30 | 12 |
| Oxazinanes | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 |
| Oxepanes | 0 | 1 | 1 | 1 | 0 | 1 | 0 | 1 | 0 |
| Phenethylamines | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Phenol ethers | 0 | 0 | 0 | 0 | 2 | 2 | 1 | 1 | 0 |
| Phenols | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 |
| Phenylpropanoic acids | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 |
| Piperidines | 3 | 0 | 0 | 0 | 3 | 1 | 2 | 2 | 1 |
| Prenol lipids | 1 | 0 | 0 | 0 | 2 | 2 | 0 | 0 | 0 |
| Pyridines and derivatives | 1 | 1 | 0 | 0 | 2 | 2 | 2 | 2 | 0 |
| Quinolines and derivatives | 1 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 |
| Saturated hydrocarbons | 1 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 1 |
| Steroids and steroid derivatives | 0 | 0 | 0 | 0 | 2 | 2 | 1 | 1 | 0 |
| Thiophenols | 0 | 0 | 1 | 0 | 0 | 1 | 0 | 0 | 0 |
| Thioureas | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 0 |
| Triazolopyridazines | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 |
| Unsaturated hydrocarbons | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
A significant decrease was observed in the total numbers of metabolites detected between the control group and the three dilution groups; control = 334, 1
:
5 = 206 (p = 0.027), 1
:
10 = 201 (p = 0.016) and 1
:
20 (p = 0.005). Additionally, the dilution of samples resulted in the notable loss of nine metabolite classes when compared to the control group. These classes were azoles, keto acids and derivatives, saturated hydrocarbons, piperidines, organic disulphides, azolidines, quinolines and derivatives, naphthalene's and furans (Table 1).
Blood staining did not result in significant changes in the total numbers of metabolites detected with 369 metabolites detected (p = 0.94). The identified metabolite classes, however, were altered with the identification of eight metabolite classes present in the blood staining group but absent in the control group. These include azolines, diazanaphthalenes, diazines, dithiols, halogen organides, phenol ethers, steroids/steroid derivatives and thioureas (Table 1). Pre-treatment of SF with hyaluronidase did not result in significant changes in the total numbers of metabolites detected. However, additional metabolite classes were detected in the hyaluronidase treated group compared to the control group. These were: azolines, benzothiophenes, diazanaphthalenes, diazines, homogeneous alkali metal compounds, organic carbonic acids and derivatives, oxepanes, phenols and phenol ethers, steroids and steroid derivatives and thioureas (Table 1). Hyaluronidase treatment also resulted in the lack of identification of other classes detected in the control group which were: indoles and derivatives, naphthalenes, organic disulfides and prenol lipids.
GC-ToF-MS analysis revealed bead beating to significantly reduce the numbers of detectable metabolites (total numbers of metabolites detected; control = 230; bead beating = 176; p = 1.15 × 10−9). Metabolite class analysis revealed metabolite classes including amino acids and derivatives, sterols and hormones, siloxanes and derivatives and aromatic and heterocyclic compounds to be absent from the bead beating group. However, there was no clear separation between the bead beating group and the control group in the PCA analysis (Fig. 2B).
No significant changes in total detectable numbers were observed in the samples that underwent freeze–thaw cycling in both lipid and HILIC analysis compared to control. Moreover, no significant changes were observed in the total numbers of detectable metabolites between the control group and the hyaluronidase treated group in both lipid and HILIC analysis.
Sample dilution demonstrated significant changes across both HILIC and lipid analysis; by which the total number of metabolites observed significantly decreased with increasing dilution. A total of 763 metabolite features were detected in the HILIC ESI+ mode and 542 in the ESI− mode, for undiluted samples. These decreased to 680 (1
:
5 dilution, p = 5.03 × 10−11), 636 (1
:
10 dilution, p = 1.69 × 10−20) and 565 (1
:
20 dilution, p = 2.29 × 10−39) in the ESI+ mode and 415 (1
:
5 dilution, p = 4.23 × 10−25), 376 (1
:
10 dilution, p = 6.16 × 10−37), 329 (1
:
20 dilution, p = 3.38 × 10−53) in the ESI− mode. 1675 and 833 metabolites were detected in the lipid analysis control group in ESI+ and ESI− modes respectively. These totals decreased to 1532 (1
:
5 dilution, p = 1.43 × 10−12), 1366 (1
:
10 dilution, p = 1.04 × 10−42) and 1276 (1
:
20 dilution, p = 4.60 × 10−64) in the ESI+ mode and 753 (1
:
5 dilution, p = 4.20 × 10−20), 618 (1
:
10 dilution, p = 2.08 × 10−64) and 508 (1
:
20 dilution, p = 8.60 × 10−107) in the ESI− mode. PCA scores plots of these data demonstrated clear separation amongst the three dilution groups in the HILIC ESI+ analysis (Fig. 3C) with no overlap of the 95% confidence intervals. Components 1 and 2 of the PCA explained 57.9% and 5.3% of total variance in the HILIC ESI+ mode (Fig. 3C) and 54.7% and 7.7% in the HILIC ESI− mode (Fig. 3D).
UHPLC-MS HILIC analysis demonstrated a significant increase in the number of metabolite features detected by ESI− mode for samples in the blood staining group (n = 557) compared to the control samples (n = 542) (p = 0.04). Conversely a significant decrease in the number of compounds was discerned in lipid ESI− mode in the blood staining group vs. control (823 and 833 respectively; p = 0.05). By further contrast, no significant changes were apparent in the HILIC ESI+ nor lipid ESI+ in observed compounds between the blood stained and control sample groups.
| Contrast | Log2 fold change | P-Value | Metabolite name |
|---|---|---|---|
1 : 5 dilution – control |
0.9534 | 0.8 | Octahydroindolizine |
1 : 10 dilution – control |
2.569 | 0.00 | Octahydroindolizine |
1 : 20 dilution – control |
1.595 | 0.18 | Octahydroindolizine |
| 2× F/T – control | 2.329 | 0.01 | Octahydroindolizine |
| 3× F/T – control | 1.286 | 0.45 | Octahydroindolizine |
| Blood stain – control | 1.051 | 0.70 | Octahydroindolizine |
| Hyaluronidase – control | 3.699 | 0.00 | Octahydroindolizine |
| Blood stain – control | 2.678 | 0.00 | 4-Fluoro-DL-tryptophan |
:
5, 1
:
10, 1
:
20) across three analytical methods: Lipid ESI+, Lipid ESI− and HILIC ESI+. Samples dilution resulted in significant reductions (p < 0.05) across all three analytical platforms
| Analysis | Treatment | P-Value |
|---|---|---|
| RP LC-MS Lipid ESI+ | 1 : 5 dilution |
9.27 × 10−4 |
1 : 10 dilution |
1.65 × 10−4 | |
1 : 20 dilution |
9.16 × 10−5 | |
| RP LC-MS Lipid ESI− | 1 : 5 dilution |
4.2 × 10−4 |
1 : 10 dilution |
5.73 × 10−5 | |
1 : 20 dilution |
2.30 × 10−5 | |
| HILIC-MS ESI+ | 1 : 5 dilution |
0.05 |
1 : 10 dilution |
0.02 | |
1 : 20 dilution |
0.02 |
:
1 response, particularly in the HILIC ESI+ mode. The distribution of R2 values revealed that most metabolites exhibited sub-linear behaviour (R2 < 0.9), consistent with matrix-dependent ion suppression. Representative metabolite response curves further illustrated the flattening of slopes at higher dilutions, supporting the conclusion that non-linear detector response contributes to the observed loss of features with dilution.
| Contrast | Log2 fold change | P-Value | Metabolite name |
|---|---|---|---|
| Bead beating – control | 8.68 | 2.55 × 10−5 | Armillaricin |
| Bead beating – control | 8.18 | 4.47 × 10−9 | Phaseic acid |
| Bead beating – control | 10 | 7.44 × 10−4 | Dimethylaminopropionylphenothiazine |
| Bead beating – control | 8.69 | 3.87 × 10−7 | Glycerol phenylbutyrate |
| Bead beating – control | 10.84 | 1.03 × 10−7 | Indoramin |
| Bead beating – control | 7.97 | 6.93 × 10−6 | NA-Gly 25:0 |
| Bead beating – control | 5.95 | 2.83 × 10−6 | Pamaquine |
| Bead beating – control | 7.77 | 7.85 × 10−9 | Bis(4-ethylbenzylidene)sorbitol |
| Bead beating – control | 7.25 | 2.24 × 10−11 | Militarinone A |
In contrast however, the three dilution groups demonstrate a pronounced decrease in fold change in the metabolite abundances of 13 metabolites (dark blue) (Fig. 4A). An increase in the metabolite abundance of four metabolites (red) across all three dilution groups was observed compared to control. These metabolites are currently unidentified. Two metabolites that showed consistent decrease in fold change across the 2× Freeze–thaw, bead beating and blood staining treatment groups, as well as two metabolites with an increased relative abundance in the blood staining group (Fig. 4B) similarly remain unannotated.
Although SF is normally yellow-straw colour, blood contamination is occasionally observed in clinical samples. Traumatic arthrocentesis, in which a small blood vessel is punctured during aspiration, is the most common cause, while inflammation or joint trauma can also increase vascular permeability and introduce red blood cells (RBCs) into the joint space. In such cases, visible red discoloration of the fluid may persist even after centrifugation, indicating that red cells have lysed and released haemoglobin and intracellular metabolites into the SF. The resulting alterations represent haemolytic contamination, a clinically relevant pre-analytical artifact that can occur in real-world SF sampling when aspiration is difficult or processing is delayed. Once haemolysis occurs, centrifugation cannot reverse the release of intracellular metabolites or haemoglobin. These observations highlight the importance of careful aspiration technique, prompt sample separation, and visual inspection of SF colour prior to metabolomic analysis.
The identification of highly abundant metabolite features in the blood staining group across both GC-ToF-MS and UHPLC-MS (HILIC) analysis demonstrate the significant influence of blood derived – particularly polar molecules – on the SF metabolomic profile. Notably, 4-fluoro-DL-tryptophan was elevated in blood-stained samples which may reflect plasma-derived contamination or haemolysis-related metabolic shifts.43 Adenine and hypoxanthine were also among the abundant metabolite features identified. Adenine is a precursor to adenine nucleotides such as ATP whilst hypoxanthine is a purine derivative that acts as an intermediate in ATP metabolism and the formation of nucleic acids.44 Our findings of elevated levels of adenine and hypoxanthine in the blood staining group are consistent with previous findings where an increase in the diffusion of non-phosphorylated purine metabolites from RBCs into plasma/serum post sample collection have been associated with blood temperature and prolonged plasma contact with cells.45 A similar mechanism may occur in blood-stained SF samples, therefore further highlighting the importance of tightly controlling post-collection sample handling and selection to reduce the artefactual elevation of RBC derived metabolites in SF samples. Aside from acting as a marker of blood staining of the SF, the increased presence of hypoxanthine in SF samples can also potentially indicate towards the presence of inflammatory forms of arthritis such as gout.46 Gout is caused by the buildup of uric acid formed through the oxidative hydroxylation of hypoxanthine to xanthine and xanthine to uric acid via the enzyme xanthine oxidoreductase.47
The presence of EDTA in this study is associated with the artificial staining of the SF using blood that was collected in EDTA tubes. This makes the EDTA a reflection of the sample collection-handling process rather than the natural state of the sample. Additionally, octahyroindolizine also known as indolizine is an exogenous, naturally occurring bicyclic compound with widespread manufacturing and pharmaceutical applications.48 The consistent increase in octahydroindolizine across all treatment groups compared to the control group suggests it could be an artifact of sample handling. These findings provide valuable reference for best practices in future metabolomic studies. By identifying markers of blood contamination and sample handling this study highlights the importance of contamination related features that researchers should be aware of as potential confounders when interpreting metabolic profiles.
Lipid analysis using reversed phase LC-MS in ESI+ and ESI− modes demonstrates the marked impact of SF preparation on lipid abundance profiles. However, the magnitude and pattern of response varied between the two modes. In the ESI+ mode, the most marked difference in the bead beating group was observed, with widespread and strong enrichment of lipid features compared to other treatments. The majority of the putatively identified compounds have been shown to be associated with extrinsic origins including pharmaceuticals, plant and fungus derived natural products and synthetic analogues, which may have come from the diet. Bead beating is a technique commonly applied in metabolomic studies as a means of sample homogenisation and cellular disruption.49 Previous studies applying bead beating on faecal and soft tissue samples (like liver and breast) have shown it to contribute towards the increased detection of lipid metabolites.50–52
The application of bead beating on SF homogenisation and matrix disruption has not been explored until now. Our findings suggest bead beating may enhance the liberation of exogenous compounds from the sample matrix. These findings suggest that bead beating may be an effective treatment at extracting a broad range of lipid classes in the SF that ionise well in ESI+. Lipid ESI− on the other hand revealed a different pattern, with the most prominent observation being the decrease in relative FC of compounds in the three dilution groups. GC-Tof-MS analysis on the other hand suggests bead beating may impact metabolite detection, although the lack of clear separation in the PCA analysis between the bead beating and control groups suggests overall metabolite variance was dominated by shared high abundance of features such as sugars. Together these results underscore the importance of matching sample treatment strategies with the strengths of the analytical technique.
Metabolomic studies often benefit from sample dilution as excessively concentrated injections can cause column overloading, signal saturation and non-linear signal responses with features falling below the detection limit.53 Further, in some instances where SF volume is limited (where there is a lack of effusion), sample dilution is required to retrieve any material for analysis. However, a common trend observed across all analytical methods applied in this study was the reduction in both the number and relative abundance of detectable metabolites with increasing sample dilution. The clear separation of the dilution groups demonstrated in the PCA analysis particularly in the HILIC ESI+ analysis suggests that even moderate changes in sample dilution can cause substantial shifts in metabolomic profiles and highlights its role as a source of both reproducible and systemic variation.
These results suggest that for untargeted SF analysis dilution may hinder rather than enhance metabolite coverage. As such, maintaining adequate sample concentration appears critical for achieving broad and reliable metabolite coverage independent of the analytical platform used. Moreover, where samples are differentially diluted, e.g. due to clinical harvest method, it is important that this dilution is accounted for before metabolomic analysis. This can be achieved via determining the SF dilution factor, using an established methodology in which urea is measured in patient matched SF and plasma and then samples manually diluted to align with the most dilute sample.19 However, the data provided in this analysis provides important information about specific metabolites whose differential abundances should be interpreted with caution in the case of differential dilution.
To further explore the effect of sample dilution on analytical performance, the linearity of detector response was evaluated across the 1
:
5, 1
:
10, and 1
:
20 dilution series (SI Fig. S2 and S3). The observed mean log2 fold changes deviated from the theoretical 1
:
1 relationship, and the majority of metabolites exhibited R2 values below 0.9, indicating a sub-linear response to dilution. Representative metabolite intensity–dilution curves further confirmed signal attenuation at higher dilutions, consistent with matrix-dependent ion suppression and reduced ionisation efficiency. Within the range tested, dilution factors between approximately 1
:
5 and 1
:
10 maintained adequate signal intensity while avoiding potential detector saturation, representing a practical balance between matrix effects and signal loss. Although ion suppression was not directly measured, this inference is supported by the sub-linear response behaviour observed across the dilution series. Together, these findings emphasise that while modest dilution can be tolerated, undiluted SF samples yield the broadest metabolite coverage and should be prioritised for untargeted workflows whenever feasible.
In this study, all datasets were normalised using QC-based LOESS correction to account for instrumental drift and analytical variability. Normalisation strategies that correct for sample-specific dilution, such as urea ratio, total metabolite or protein content normalisation, and probabilistic quotient normalisation (PQN54), were not applied, as the goal was to evaluate the intrinsic impact of pre-analytical sample handling. Future work to assess whether such normalisation approaches can reduce dilution-related bias in clinical SF metabolomics, where variable sample volume and viscosity are often unavoidable is required.
Freeze–thaw cycling did not demonstrate a significant impact on the total numbers of metabolites/metabolite features that were detectable across both of the analytical methods compared in this study. Additionally, clear separation of the samples that underwent freeze–thaw cycling from the rest of the treatment groups visualised on the PCA scores plots suggested minimal impact of this variable on metabolome profile. These results suggest that the SF metabolome exhibits a high level of stability for up to three freeze–thaw cycles. These results are in line with previous studies by Jaggard et al.32 and Damyanovich et al.30 that tested the impact of up to 5 and 10 freeze–thaw cycles respectively using nuclear magnetic resonance (NMR) where SF samples demonstrated stability with no significant changes to detectable metabolites observed.
The enzymatic treatment of SF with hyaluronidase is widely applied in proteomic studies where it has been shown to enhance the detection of proteins in addition to viscosity reduction and sample homogenisation.31,55 However, no studies have explored its impact on enhancing SF metabolite detection. The results from this do not suggest this treatment to significantly increase the total numbers of detectable metabolites.
Though this study has provided valuable initial insights into the effects of pre-analytical variable on the SF metabolome, several limitations should be acknowledged. This study was limited by the small sample size (n = 5 per treatment group) which restricts statistical power to detect more subtle effects. Consequently, the PCA results should be interpreted qualitatively as a means of visualising general trends. Additionally, the use of artificially induced blood staining while controlled may not fully replicate the complexity of spontaneous hemarthrosis or clinical contamination scenarios. While the study investigated the impact of up to three freeze–thaw cycles, it did not explore variations in thawing conditions (e.g. room temperature vs. ice) or the impact of storage under different conditions or storage time, all of which may further influence metabolite stability. Future work should include larger cohorts to validate the findings in this study and investigate additional pre-analytical factors that were not explored in the current study. Finally, the level of metabolite identification is rarely to MSI level 1,42 but this does not limit the findings in terms of the number metabolite features that are different between the various treatment groups.