DOI:
10.1039/D5TC00117J
(Paper)
J. Mater. Chem. C, 2025,
13, 10804-10816
Highly transient and recyclable MoS2/PVA pressure sensor for sustainable healthcare and consumer electronic applications†
Received
10th January 2025
, Accepted 15th April 2025
First published on 17th April 2025
Abstract
The advent of electronic gadgets has brought convenience to daily life; however, it has also contributed to the proliferation of electronic sensors, exacerbating the issue of electronic waste (e-waste). Previous efforts toward transient electronics aimed at addressing e-waste have faced challenges due to material wastage. To overcome these limitations, it would be beneficial to develop a process wherein transient electronics are reusable. In this study, a transient pressure sensor was fabricated using MoS2 and PVA, and its degradation in an aqueous medium was subsequently demonstrated. The MoS2, which served as the active material, was recovered after degradation and reused for the fabrication of another pressure sensor. Electrical tests on the sensor demonstrated its piezoresistive nature, with the device capable of detecting various pressures in the range of 1–3 kPa, exhibiting a sensitivity of 0.87 kPa−1. A cyclic test was also conducted for 1200 cycles, revealing excellent durability. Moreover, the sensor maintained stable performance over three months without any loss in electrical properties. The fabricated sensor was employed in real-time applications, such as detecting the radial artery pulse (hand), carotid artery pulse (neck), and varying air pressures from a syringe bulb, and it was also used as directional keys for a gaming console. The MoS2/PVA sensor dissolved completely within 300 s. The performance of the recycled MoS2/PVA sensor was compared with that of the original MoS2/PVA sensor, showing negligible differences. The successful demonstration of a MoS2/PVA-based transient and recyclable pressure sensor holds immense potential for future IoT applications.
Introduction
Every year, technology undergoes rapid advancements, deeply influencing various aspects of modern societal lifestyles.1 The increasing reliance on electronics contributes to an enhanced quality of life and improvements in human health.2 Advances in processing techniques have led to enhanced electronic performance, driving consumers to purchase more electronic products and discard older ones (e.g., smartwatches and smartphones). These discarded electronics become electronic waste (e-waste).3 E-Waste presents a hazardous threat to the environment, posing risks to the health of living beings.3 According to surveys, e-waste production has escalated to a concerning rate of 7.5 kg per person per year.1,4 Only a fraction, approximately 10–20%, of this waste is recycled, while the majority is disposed of in landfills.5 This waste releases hazardous chemicals and toxic materials into the environment.3 According to the World Economic Forum, global electronic waste production surpassed 53.6 million tons in 2019, with projections indicating it could reach 74.7 million tons by 2030.6,7 Recently, a new type of technology has emerged, completely opposite to conventional electronics, known as transient electronics.8,9 These electronics are designed to dissolve or disintegrate after use, thereby minimizing e-waste.10 However, current applications are largely limited to therapeutics and biologically integrated circuits, which are often made from silicon-based materials that themselves contribute to e-waste.3,11 The aim is to develop fully recyclable electronics, in which environmentally harmful materials are reclaimed and reused.
In recent years, research communities have increasingly focused on this issue. A recent report highlighted the progress in recyclable electronics. Xu et al. developed a recyclable ink composed of polyvinyl alcohol and a liquid metal. Flexible sensors fabricated using this liquid metal ink offer a wide range of applications, high sensitivity, and consistently stable signal generation. Additionally, the liquid metals in these printed flexible sensors can be recycled under alkaline conditions.12 Williams et al.13 fabricated transistors by utilising carbon nanotube as a semiconductor, nanocellulose as a dielectric, graphene as a conductor, and paper substrate. These transistors demonstrate consistent performance up to six months in ambient conditions. Later, decomposed carbon nanotubes and graphene inks can be recollected for recycling and reprinting of new transistors.13 In another study, Liu et al.14 reported on the recycling of silver nanowire (AgNW) percolation networks to enable soft electronics. The AgNW network film can be recycled multiple times, with no significant changes in morphology or performance degradation. Additionally, a transient sensor patch has been fabricated using AgNW electrodes and a water-soluble polymer substrate, and completely recycled.14 Guo et al.15 presented a conductive recyclable composite for wearable electronics, including a capacitive pressure sensor, a triboelectric nanogenerator, and a flexible keyboard. This composite material is recyclable and degradable. Combining multiple functions and sustainable manufacturing in one electronic device is highly desirable for design and fabrication.15 Tengyang et al.16 presented a recyclable dual-mode thin-film device capable of simultaneously performing light emission and heat management. The device demonstrates complete recyclability and a reconstruction ability, maintaining performance integrity even after multiple recycling cycles. Soft-matter electronics with characteristics including resilience, repairability, and recyclability can reach the same level of advancements as industrial electronics.16 Tavakoli et al.17 reported novel microchip-integrated soft-matter electronics with the recycling of advanced skin patches with embedded electrodes, microchips antennas, and sensors, capturing human electrophysiological signals.17
The unique properties of two-dimensional (2D) materials have attracted significant attention within the scientific community. 2D materials have exceptional electrical, electronic, mechanical, and optoelectronic properties and offer a promising avenue for enhancing the performance of electronic devices.18,19 After, graphene, a diverse range of 2D materials offer exceptional electrical, mechanical, and optoelectronic characteristics, particularly 2D transition-metal dichalcogenides (TMDs) like molybdenum disulfide (MoS2), making them ideal candidates for applications in transistors, photodetectors, flexible electronics, and more.20 Despite these advantages, the insolubility of pristine 2D MoS2 poses challenges for their use in transient electronics, which require materials that can dissolve or degrade in a controlled manner.21 The processing and integration of 2D TMDs into transient devices can be complex and costly.22 Nevertheless, this challenge can be turned into an opportunity by focusing on the recyclability of these materials. Since pristine 2D MoS2 is insoluble in water, devices made from these materials can be recovered after use, allowing the valuable material to be recycled and reused. This approach addresses the environmental concerns associated with electronic waste and enhances the sustainability and economic viability of transient electronic devices by promoting the recycling of key materials.
This work presents a recyclable and reusable pressure sensor by utilizing 2D MoS2 as the functional material and water-soluble polyvinyl alcohol (PVA) polymer. The benefits of PVA polymer are its biocompatibility, flexibility, durability, water solubility, and low cost, making it suitable for a recyclable pressure sensor. Notably, the plain PVA film exhibits very high resistance (∼5.4 GΩ),8 with the conductivity of the fabricated device solely attributed to 2D MoS2. Sensor fabrication process commences with the synthesis of 2D MoS2 material via the hydrothermal method, followed by comprehensive characterization of MoS2. Subsequently, the synthesized MoS2 liquid is blended with PVA polymer to form a film. The sensor exhibits a piezoresistive nature and was tested across various pressures, demonstrating its capability to detect pressures within 1–3 kPa, with sensitivity of 0.87 kPa−1. Additionally, the sensor demonstrates good durability of up to 1200 cycles, rise and fall time of 260 ms and 320 ms, respectively. Furthermore, the recyclable MoS2/PVA pressure sensor was utilized for detecting radial artery pulse (hand), carotid artery pulse (neck), different air pressures from syringe bulb, and also serves as a directional key for the gaming console. Polyvinyl alcohol (PVA) is widely recognized for its biocompatibility and non-toxic nature,23 making it an ideal material for biomedical applications.24 In the recyclable MoS2/PVA sensor fabrication, MoS2 is incorporated within the PVA matrix, ensuring that MoS2 material does not come in contact with the skin. This embedding of MoS2 in the PVA matrix minimizes the potential biocompatibility concerns because PVA acts like a protective cover, eliminating any adverse interaction between MoS2 and biological tissues. Finally, the transience test shows that the MoS2/PVA sensor dissolves in 300 s. Comparison of the performance of the fabricated recyclable MoS2/PVA sensor with the original MoS2/PVA pressure sensor reveals a negligible difference in temporal response. Under a constant pressure of 1 kPa, the recycled sensor exhibited a 10% change in current response compared to the original sensor. Furthermore, the resistance of two recycled water-soluble MoS2/PVA sensors was monitored over 90 days and compared to the resistance of the original MoS2/PVA sensor. The water soluble and recyclable MoS2/PVA sensor are designed to addresses the critical challenge of electronic waste (e-waste). Unlike traditional sensors, this recyclable sensor offers an eco-conscious solution by enabling environmentally friendly disposal and reuse. The hydrophilic nature of the PVA substrate dissolves in DI water, eliminating persistent waste while allowing for efficient recovery of MoS2 material. This recyclability supports multiple fabrication cycles, making the process cost effective and enhancing sustainable. This MoS2/PVA sensor provides a scalable, energy-efficient, and environmentally friendly alternative to conventional MoS2 based devices by combining temporary functionality with recyclability. This makes it ideal for recyclable or disposable electronics, biomedical sensors, and eco-friendly environmental monitoring, aligning with global effects to reduce resource consumption and waste in electronics.
Experimental section
The water-soluble pressure sensor composed of recycled MoS2 functional material is fabricated through a two-step process. First, 2D MoS2 material is synthesized using a facile hydrothermal method. Subsequently, MoS2 liquid is combined with a water-soluble PVA polymer to form a recycled MoS2/PVA thin film, with copper contacts attached to the MoS2/PVA thin film used for pressure sensing applications. Informed consent was obtained for the experiments involving human participants.
Materials
Polyvinyl alcohol (Mw: 61
000 g mol−1, 98.0–98.8 mol% hydrolysis), sodium molybdate (Na2MoO4), and L-cystine were procured from SRL and Sigma Aldrich chemicals. During the synthesis, 0.01 M HCl was utilized. The morphology of MoS2 and MoS2/PVA films was analysed using field electron scanning electron microscopy (FESEM, FEI Apreo Lovac). The chemical composition of synthesized MoS2 analyses was performed using XPS (Thermo Fisher Scientific K-Alpha XPS system). The electrical characteristics of the MoS2/PVA sensor and the recycled MoS2/PVA sensor were evaluated using a Keithley 2450 source meter.
MoS2 synthesis
The synthesis of 2D MoS2 material was achieved through a facile hydrothermal method, utilizing sodium molybdate and L-cystine precursors. The synthesis begins by dissolving sodium molybdate of 300 mg in 20 mL of DI water and sonicating for 15 min. Similarly, 300 mg of L-cystine is mixed with 50 mL of DI water and subjected to ultrasonication for 10 min to obtain a transparent solution. Subsequently, both prepared solutions are thoroughly mixed using a magnetic stirrer for 30 min. To maintain a pH of 6.5, HCl is added to the mixed solution. Finally, the thoroughly mixed solution is transferred to an autoclave and maintained at 200 °C for 16 h, followed by natural cooling. The resulting solution is centrifuged at 4000 rpm for 30 min to collect the MoS2, which is then stored in a dark place for further experiments. The synthesis of MoS2 is illustrated in Fig. 1.
 |
| Fig. 1 Synthesis of 2D MoS2 and fabrication of the water-soluble MoS2/PVA pressure sensor. | |
Fabrication of the MoS2/PVA sensor
The MoS2/PVA sensors were fabricated using different concentrations of MoS2/PVA solution (0.025 wt%, 0.125 wt%, 0.25 wt%, 0.375 wt%, 0.5 wt% and 0.6 wt%). The mixtures were continuously stirred for 6 h at 60 °C. Next, the thoroughly mixed solutions were poured into Petri dishes and kept in an oven at 60 °C for 6 h. The sensor fabrication processes are illustrated in Fig. 1. However, a uniform MoS2/PVA film only formed above 0.375 wt%. The formed film (0.5 wt%) in the Petri dish after heating in oven is depicted in Fig. S1a of the ESI.† The carefully peeled MoS2/PVA film is shown in Fig. S1b of the ESI.† The resulting films were cut into 1.5 cm × 1 cm dimensions. The copper wire was attached to the film with the help of silver paste, and later kept in oven at 60 °C for 3 h to make a strong bond between the MoS2/PVA film and copper contacts. The sensor's flexibility did not significantly impact its performance. The MoS2/PVA sensor fabrication process is scalable and compatible for mass production, making it suitable for industrial applications. Unlike other 2D material synthesis techniques, the hydrothermal process operates at lower temperatures and reduces the energy demands. Furthermore, the solution-casting processes avoid the need for complex vacuum systems or high-cost equipment, making it cost-effective and adaptable for large-area, high-throughput fabrication. The bending of the sensor with the copper wire attached using silver paste is shown in Fig. S1c of the ESI.† Moreover, the MoS2/PVA film exhibits the highest conductivity at 0.5 wt%. The comparison Table S1 (ESI†) of MoS2/PVA sensors at different concentrations and their resistivity values are included in ESI.†
Characterization
A facile hydrothermal method was employed to synthesize the MoS2 material. The resulting MoS2 material and fabrication of MoS2/PVA sensor morphology was validated by scanning electron microscopy (SEM), the chemical composition of MoS2 was analyzed using XPS spectroscopy, the crystalline structure was analyzed using XRD, and chemical bonds were identified using Raman spectroscopy. Fig. 2 illustrates the detailed material characterization of MoS2 and MoS2/PVA sensors. The SEM image of synthesized MoS2 showcases a flower like morphology consisting of hollow microspheres (Fig. 2a).25Fig. 2b shows the morphology of the fabricated MoS2/PVA pressure sensor. The prepared MoS2 chemical composition was determined using Raman analysis. The conformation of prominent peaks identified at 408 cm−1 and 383 cm−1 (Fig. 2c) corresponds to A1g (out-of-plane vibration) and E1g (in-plane vibration) modes, respectively.26 XRD analysis for virgin MoS2 and recycled MoS2 showed that the peak position is largely identical, confirming the unchanged crystalline nature after recycling. X-ray diffraction (XRD) analysis of MoS2 referenced against JCPDS no. 37-1492 confirms its hexagonal crystal structure. The characteristic peaks for virgin MoS2 and recycled MoS2 are at the (002), (100), (103), and (110) planes (Fig. 2d), which validates the material's crystalline phases. However, there is additional peak at 19.44° (101) in recycled MoS2, which is attributed to residual PVA. The MoS2/PVA composite's mechanical performance was assessed using tensile testing. Fig. 2e shows the standard composite MoS2/PVA stress–strain curve. Young's modulus is represented by the slope of the elastic deformation zone. Young's modulus, also known as the modulus of elasticity, indicates the stiffness and capacity of MoS2/PVA samples to tolerate deformation under tension, whereas the tensile strength in this instance indicates the highest stress that the MoS2/PVA thin film can sustain under stretching before failing. The ratio of the modified length to the original length following the breakage of the MoS2/PVA sample is known as the strain to failure (or elongation at break). A tensile strength of about 20 MPa and a Young's modulus of about 400 MPa are indicated by the elastic area (5%), which is visible on the stress strain curve.27,28
 |
| Fig. 2 Structural and mechanical characteristics of the MoS2 and MoS2/PVA sensors. (a) FESEM image of synthesized MoS2, showcasing a flower-like morphology consisting of hollow microspheres. (b) Morphology of the fabricated MoS2/PVA sensor. (c) Raman spectra of synthesized MoS2 with peaks ranging between 378 and 470 cm−1. (d) XRD spectra of both virgin MoS2 and recycled MoS2. (e) Stress–strain curve of the fabricated MoS2/PVA sensor. | |
X-ray photoelectron spectroscopy (XPS) analysis was performed to analyze the chemical components of MoS2. Fig. 3a displays the full survey spectrum of MoS2, revealing the presence of Mo, S, C, and O elements. The Mo 3d spectrum shows the two distinctive peaks at 229 eV (Mo4+ 3d5/2) and 232 eV (Mo4+ 3d3/2) (Fig. 3b), indicative of the Mo(IV) oxidation state of MoS2. Meanwhile, another peak at 235.7 eV corresponds to the Mo6+ state of MoO3. Additionally, a faint peak at 226.1 eV is attributed to S 2s. Furthermore, two prominent peaks at 161.8 eV and 163 eV (Fig. 3c) correspond to the binding energies of S 2p1/2 and S 2p1/3 for S2–.29 The peak around 531.2 eV (Fig. 3d) corresponds to O 1s. The primary reason for the O 1s peak in the MoS2 survey spectrum is due to partial oxidation of MoS2 when exposed to air.30,31 The above characterization results confirm the formation of MoS2 using a facial hydrothermal method.
 |
| Fig. 3 XPS analysis of the prepared MoS2 material. (a) Survey spectrum of synthesized MoS2. (b) The Mo 3d5/2 and Mo 3d3/2 peaks are centered at 229 eV and 232 eV, respectively. (c) The peaks of S 2p3/2 and S 2p1/2 are centered at 161.8 eV and 163 eV, respectively. (d) Oxygen spectrum showing a peak at 531.2 eV. | |
Pressure sensing
The fabricated MoS2/PVA sensor performance was evaluated by applying different pressures between 1–3 kPa. The water-soluble flexible pressure sensor was developed by combining MoS2 with polyvinyl alcohol (PVA) with copper wire contacts. The fabricated film was cut into length (L) and width (W) of 1.5 cm and 1 cm and with the help of silver paste copper wires connected to the sensor. The fabricated pressure sensor electrical response was measured using a Keithley source meter. The I–V characteristics at different pressures and linearity between currents and voltages indicates that the fabricated sensor is a piezoresistive type and resistance decreases with applied external pressure between 1–3 kPa (Fig. 4a). A constant working voltage of 1 V is applied to the sensor to measure its current response. A constant pressure of 1 kPa is applied on the sensor (Fig. 4b). The sensor current response increased with the application of constant pressure, with the sensor current response recovering to the initial state of 4.92 × 10−7 A upon the release of the external pressure. The fabricated flexible MoS2/PVA pressure sensor is subjected to different external pressures in the 1–3 kPa range (Fig. 4c). The sensor resistance decreases with increasing pressure, which eventually increases the current intensity. The response sensitivity of the fabricated piezoresistive sensor is generally represented as
where p is the applied pressure, and ΔR/R is the relative change of resistance upon applying the pressure. Three MoS2/PVA sensors were tested and the MoS2/PVA pressure sensor's sensitivity was calculated. The results illustrate consistent response trends across MoS2/PVA sensors, which suggests good reproducibility. There were minute variations in the sensor's performance, which can be attributed to processing conditions. The sensitivity and coefficient of determination of the three MoS2/PVA sensors are approximately 0.87 kPa−1 and 0.994, respectively.10,32Fig. 4d illustrates the sensitivity and coefficient of determination (R2) of fabricated MoS2/PVA sensors. The rise time and fall time of the sensor signal response are significant (Fig. 4e and f). The sensor signal response rise from 10% to 90% is called the rise time. In contrast, the sensor signal response falls from 90% to 10% and is called the fall time. The rise and fall time are 260 ms and 320 ms, respectively. The fabricated sensor underwent a cyclic test to further demonstrate the performance (Fig. 4g). The current response shows a negligible change for 1200 loading and unloading cycles, which was well retained over multiple cycles. The resistance of two water-soluble MoS2/PVA sensors was tested continuously for 90 days, and a negligible change in the resistance response was observed (Fig. 4h). Hysteresis analysis was performed on the fabricated MoS2/PVA recyclable sensor to evaluate the response under loading and unloading conditions. The recyclable MoS2/PVA sensor shows minimal hysteresis, indicating its high reliability and repeatability in pressure sensing. The hysteresis graph is presented in Fig. S2 of the ESI.† Finally, a humidity test was conducted for the fabricated MoS2/PVA sensor to check whether the senor was affected by the surrounding environment. The humidity test was conducted in a humidity chamber. There was negligible change in the performance of the sensor under normalized resistance (Fig. S3 in ESI†).
 |
| Fig. 4 Performance evaluation of the recyclable MoS2/PVA sensor under different pressures. (a) I–V characteristics of the MoS2/PVA pressure sensor at different pressures. (b) Constant pressure of 1 kPa applied to the fabricated sensor. (c) Pressure sensor response increase at different pressures. (d) The calculated sensitivity of three sensors is approximately 0.87 kPa−1 with a coefficient of determination (R2) of 0.994. (e) Calculated rise time of 260 ms. (f) Calculated fall time of 320 ms for the fabricated sensor signal response. (g) Durability of the MoS2/PVA pressure sensor tested for 1200 cycles. (h) Response of the sensor resistance of two devices over 3 months. | |
The sensing mechanism of the fabricated sensor is the modulation of the distance of MoS2 flakes upon external pressure. This mechanism is schematically depicted in Fig. 5. The conducting MoS2 flakes are covered with polymer on both sides, forming a resistive film. When no pressure is applied, the distance (d1) between the MoS2 flakes remains unchanged (Fig. 5, schematic I), resulting in no alteration in current response and resistance. However, the distance (d2, d3) between MoS2 flakes is reduced and is close to the tunnelling distance between the two flakes upon the applied pressure to the sensor. As a result, the charge carriers (electrons) tunnel between them. This reduced distance leads to a decrease in resistance within the MoS2/PVA pressure sensor, enabling higher flow of current. Here, the change in resistance of the sensor directly correlates with the applied pressure. Additionally, water soluble PVA serves as an important component in the fabrication process, acting as a binder to hold the MoS2 flakes together and providing mechanical stability to the pressure sensor. Furthermore, the flexibility of PVA allows the sensor to undergo deformation under applied pressure and ensures that the distance between the flakes can be effectively modulated by external pressure. Therefore, the combination of MoS2 flakes and PVA polymer contribute to the exceptional performance of the pressure sensor in a pressure sensing application.
 |
| Fig. 5 (I)–(III) Sensing mechanism of the fabricated water-soluble MoS2/PVA sensor. | |
Applications of the fabricated MoS2/PVA pressure sensor
The water-soluble flexible MoS2/PVA pressure sensor was utilized for real-time applications owing to its outstanding pressure sensing results like a sensitivity of 0.87 kPa−1, excellent durability over 1200 cycles, and stable performance. Initially, it was utilized for detecting air pressure from a bulb syringe, and it later proved effective in capturing various physiological signals from the human body. Subsequently, it was used as directional keys (left, right, up, and down) for a handheld game console. The pressure sensor was attached to an acrylic sheet. Its contacts are connected to the probes of a source meter to detect the current response. The resulting current response was observed when the air was squeezed and released onto the MoS2/PVA sensor using the bulb syringe. Fig. 6 illustrates the positioning of the bulb syringe at three different distances from the sensor: 1 cm, 3 cm, and 5 cm. Remarkably, the sensor demonstrated the ability to detect air from various distances, with corresponding changes in the magnitude of the signal response. At a distance of 1 cm, the current response exhibited a higher magnitude due to the higher pressure of air. Conversely, the magnitude of the current response decreased as the distance increased from 1 cm to 5 cm. This experiment highlighted the sensor's capability to detect changes in the pressure of air, and this feature is required for applications that demand sensitivity to minute changes in airflow.
 |
| Fig. 6 Recyclable MoS2/PVA sensor for detection of bulb syringe air at varying distances. (a–b) Bulb syringe air detected by the water-soluble MoS2/PVA pressure sensor at a distance of 1 cm, (c–d) 3 cm, and (e–f) 5 cm. | |
The fabricated MoS2/PVA pressure sensor was integrated with a bandage to provide mechanical support and facilitate practical application in detecting arterial pulses. The central part of bandage supports the MoS2/PVA sensor, while the two ends of the bandage support copper electrodes. The sticky nature of the two ends of the bandage ensures that the sensor electrodes are securely adhered, providing mechanical strength and stability. This configuration allows for a reliable connection of the probes from the source meter, ensuring an accurate and consistent pressure sensing during real time application. The setup is particularly effective for detecting artery pulses in the hand carotid artery pulses in the neck. The carotid pulse plays a crucial role in blood circulation, offering vital insights into the body circulatory system. Many specialized biomedical technologies currently rely on expensive, bulky, and uncomfortable instruments, limiting their practical applications. However, the water-soluble MoS2/PVA pressure sensor offers a cost-effective and straightforward alternative for monitoring real-time carotidal arterial pulse signals. The sensor was installed on the subject's artery to record the pulses (Fig. 7a) and the inset Figure depicts the MoS2/PVA sensor attached to the bandage for support. The MoS2/PVA pressure sensor detected artery pulses (Fig. 7b). Fig. 7c shows the artery pulse exhibiting three peaks labelled as P1, P2, and P3.33 Subsequently, the flexible and easily conformable fabricated water-soluble MoS2/PVA sensor was employed to capture the radial artery pulse from the left hand (Fig. 7d). The arterial pulse is a peripheral signal used to assess cardiovascular health. This signal detected by the MoS2/PVA sensor is depicted in Fig. 7e. The arterial pulse is commonly employed for measuring blood pressure. A typical pulse wave is depicted in Fig. 7f, marked with A, P, V, and D. Here, A represents the baseline, P indicates the percussion wave, V signifies the valley, and D denotes the dicrotic wave.34,35
 |
| Fig. 7 The MoS2/PVA sensor utilized for arterial pulse detection. (a) Fabricated sensor affixed to the neck with the help of a bandage; the inset shows the pressure sensor attached to the bandage. (b) and (c) Carotid arterial pulse (neck) detected by the fabricated pressure sensor. (d)–(f) Radial artery pulse (hand) detected by the MoS2/PVA pressure sensor. | |
The fabricated sensor serves to sense signals from the human body and can be used as directional keys for the game console (Fig. 8). Fig. 8(a) and (b) illustrate using the sensor to play a Mario game, where pressing the upward direction key causes Mario to jump. To integrate the sensor into the gaming console, foam was cut into four square pieces measuring 2 cm × 2 cm to provide support for the fabricated sensor. The MoS2/PVA pressure sensor was then attached to these foam pieces along with its contacts. Each of the four sensor contacts was connected to the game console, allowing the sensors to function as directional keys. The latency of the fabricated MoS2/PVA sensor was approximately 420 ms when subjected to external pressure. This setup enabled effective and responsive interactions with the game console, demonstrating the practical application of the MoS2/PVA pressure sensor in gaming.
 |
| Fig. 8 Demonstration of recycled MoS2/PVA pressure sensor keys for Mario game application. (a) Directional MoS2/PVA keys connected to the gaming console. (b) Playing the Mario game by pressing the upward directional MoS2/PVA sensor key. | |
Fig. 9a–d displays a series of images depicting the fabricated MoS2/PVA sensor dissolved in DI water for ∼300 s. The sensor is placed in a Petri dish filled with DI water (Fig. 8a). Water-soluble PVA reacts with DI water and gradually disintegrates after 100 s (Fig. 9b and c). Finally, Fig. 9d illustrates the complete dissolution of PVA in DI water, leaving behind traces of MoS2. The dissolution of the sensor is due to the hydrophilic nature of polyvinyl polymer chains of hydroxyl (–OH) groups. When the MoS2/PVA sensor comes in contact with DI water, the water molecules interact with the hydroxyl groups through hydrogen bonding. These interactions weaken the intermolecular forces holding the polymer chain together, eventually causing them to separate and dissolve in the water, leaving MoS2 traces in DI water. The highly transient feature of our fabricated recyclable MoS2/PVA sensor is manifested by its quick dissolution in DI water. The fabricated MoS2/PVA sensor dissolves within 300 s, showing its rapid transient nature compared with other literature utilizing similar materials for transient electronics. A table comparing the transient time between different sensors with our fabricated MoS2/PVA sensor is shown in Table S2 in the ESI.† During the transience test, the sensor completely dissolved in deionized (DI) water, leaving the functional material, MoS2, at the bottom of the Petri dish. The MoS2 solution was dried by placing the Petri dish in an oven at 60 °C. The resulting MoS2 powder was collected and washed with DI water and placed back in the oven at 60 °C. This process was repeated three times to ensure the removal of any contaminants. Finally, the recycled MoS2/PVA sensor was fabricated using the collected MoS2 powder, following the same fabrication process shown in Fig. 9e–i.
 |
| Fig. 9 Dissolution and recycling process of the MoS2/PVA sensor. (a)–(d) Sequence of images illustrating the dissolution of the fabricated sensor in water, which completely dissolves in ∼300 s, with the functional material MoS2 powder remaining on the surface of the Petri dish. (e) MoS2 powder collected after being dried in an oven. (f)–(i) The recycled MoS2/PVA pressure sensor fabrication process. | |
Fig. 10a shows the temporal response of the recycled MoS2/PVA sensor under a constant pressure of 1 kPa. The sensitivity calculated for the original and recycled sensor showed 10% deviation. The calculated sensitivity of the recycled MoS2/PVA sensor along with the coefficient of determination is shown as Fig. S4 of the ESI.† The 10% current deviation in the recycled sensor is considered “negligible” because this level of variation does not significantly impact the sensor's functionality for the specific application targeted. Unlike absolute current measurements, the MoS2/PVA sensor operates based on the relative change in current upon applied pressure. Thus, 10% deviation is negligible because the sensor's core function (detecting and responding to pressure changes) remains unaffected, making it suitable for the intended application. Additionally, the resistance of two recycled water-soluble MoS2/PVA sensors was tested for 90 days and compared with the resistance of the original MoS2/PVA sensor resistance. There is a negligible change in the resistance response of the recycled MoS2/PVA and original MoS2/PVA sensor results (Fig. 10b).
 |
| Fig. 10 Performance evaluation of the recycled MoS2/PVA sensor. (a) Constant pressure of 1 kPa applied to the recycled MoS2/PVA sensor. (b) Response of the sensor resistance of two devices (MoS2/PVA sensors) and two devices (recycled MoS2/PVA sensors) over 3 months. | |
State of the art
In recent years, research efforts have significantly intensified in focusing on developing flexible pressure sensors due to their versatile applications in areas like healthcare monitoring, human–computer interaction, wearable electronics, and robotics.36 Zhao et al.37 presents a flexible pressure sensor using a laser-induced graphene. The sensor is designed with a simple and efficient fabrication process, utilizing LIG electrodes and a dielectric layer. The sensor achieves a wide working range from 0 Pa to 10.4 kPa, detection limit as low as 1.2 Pa, and high sensitivity up to 2.52 kPa−1. The sensor's performance makes it suitable for various real-world applications, such as motion detection and health monitoring, demonstrating excellent stability and responsiveness.37 Similarly, Guan et al.38 introduced a novel, scalable method for transforming natural wood into a flexible pressure sensor with high sensitivity and stability. The process involves converting rigid wood into flexible wood (FW) through chemical treatment and enhancing its conductivity by coating it with reduced graphene oxide (rGO). The resulting FW/rGO-based pressure sensors exhibit impressive performance, including a high sensitivity of 1.85 kPa−1, a broad linear range up to 60 kPa, and excellent durability over 10
000 cycles.38 In another work, Cao et al.39 developed a novel pressure-sensing material inspired by human skin's dual mechanoreceptors. The authors designed 3D printed laminated graphene materials with ultrathin and thick-walled cellular microstructures to achieve a piezoresistive pressure sensor. The laminated graphene structure allows for the creation of flexible pressure sensing arrays, showing potential applications in monitoring physiological signals, electronic skin, and human–machine interfaces.39 Yang et al.40 fabricated a flexible pressure sensor based on MXene/polyurethane (PU) with a spinosum structure, created using a cost-effective spray method. The sensor exhibits exceptional sensitivity, with rapid response and recovery times, and remarkable durability over 10
000 cycles. Its unique self-healing ability is derived from the hydrogen bonds in PU, allowing it to recover functionality after mechanical damage.40 Huang et al.41 developed a highly sensitive and flexible pressure sensor that utilizes a randomly distributed columnar array structure to achieve a wide linear pressure response range. The sensor was fabricated using aerosol printing and sandpaper inversion techniques and features a bilayer contact-resistive structure with a flexible interdigital electrode as the active layer. The sensor demonstrates high sensitivity (38.25 kPa−1), a fast response time (43 ms), and excellent stability across a pressure range of 0 to 128 kPa. Its potential applications include monitoring human physiological signals like pulse and sound vibration, making it suitable for wearable health monitoring and robotics.41 Li et al.42 introduced a highly sensitive pressure sensor utilizing a sponge-like structure composed of PDMS, liquid metal, and nitrogen-doped graphene nanosheets. The sensor is designed for wearable health monitoring and can detect small pressure changes with high sensitivity, rapid response, and recovery times. The integration of liquid metal into the sponge structure enhances the sensor's performance by improving charge transfer at the interface, making it capable of real-time monitoring of human activities like pulse, skin pressure, and throat movements.42 Yue et al.43 fabricated an ultra-sensitive pressure sensor. The sensor is constructed using large alveolar deep tooth electrodes combined with a stretchable, oriented thermoplastic polyurethane serving as an isolation layer. This design enhances the sensitivity and broadens the linear range of the sensor, achieving an ultra-high sensitivity of 230 kPa−1 between 1.1 to 100 kPa.43 Lv et al.44 presents a flexible pressure sensor using a wrinkle-structured MXene film. The wrinkle structure enables the sensor to achieve exceptional performance, including a high sensitivity of approximately 860 kPa−1 and a detection range from 0.5 Pa to 30 kPa. The sensor also exhibits rapid response and recovery times and high stability over 11
600 cycles. This makes it highly suitable for real-time monitoring of small motions, such as human physiological signals, and various objects, showing significant potential for applications in wearable electronics, precision instruments, and human health monitoring.44 A comparison of various fabricated sensors with a recyclable MoS2/PVA sensor is shown in Table 1. Even though researchers have employed novel materials to enhance the performance of pressure sensors, these materials often contribute to e-waste after their use. To address this issue, our developed MoS2/PVA sensor is designed to dissolve in water, allowing the MoS2 to be recovered and recycled for the fabrication of new pressure sensors. This approach improves performance and promotes sustainability by reducing e-waste. The current recyclable MoS2/pressure sensor operation range of 1 kPa to 3 kPa aligns well with the requirements for subtle physiological monitoring, such as arterial pulse detection. Our sensor is designed for wearable, biomedical and gaming applications while existing industrial pressure sensors often operate in the tens to hundreds of kPa range for heavy-load sensing. A comparison table of current recycled MoS2/PVA sensors exhibiting exciting physiological signal monitoring are shown Table S3 in the ESI.†
Table 1 Comparison of various fabricated sensors with the recyclable MoS2/PVA sensor
S. no. |
Material |
Substrate |
Applications |
Reusable |
Cite |
1 |
Laser-induced graphene (LIG) |
Polyimide (PI) paper |
Health monitoring and motion detection |
No |
37
|
2 |
rGO |
Flexible wood (FW) substrate |
Wearable electronics and electronic skins |
No |
38
|
3 |
RGO |
Polydimethylsiloxane (PDMS) |
Electronic skin |
No |
39
|
4 |
MXene |
Polyurethane (PU), polyimide (PI) |
Human-activity monitoring |
No |
40
|
5 |
Ecoflex00-30, multi-walled carbon nanotubes (MWCNTs), PEDOT, silver nanoparticles |
Polyimide (PI), polydimethylsiloxane (PDMS) |
Human physiological signals |
No |
41
|
6 |
Nitrogen-doped graphene nanosheets (N-GNS), liquid metal (LM) |
Polydimethylsiloxane (PDMS) |
Monitoring of human activities |
No |
42
|
7 |
Titanium (Ti) and silver (Ag) |
Polydimethylsiloxane (PDMS) |
Monitoring human pulse waves |
No |
43
|
8 |
Mxene |
VHB tape |
Human physiological signals |
No |
44
|
9 |
MoS2 |
PVA |
Healthcare and consumer electronic |
Yes |
This work |
The MoS2/PVA sensor exhibits good performance in flexible sensing applications and shows reusable characteristics of the fabricated sensor. However, key limitations must be addressed for broader applications. The main challenge of the fabricated MoS2 sensor is its biodegradability, while PVA dissolves in DI water. Understanding the long term environmental impact is important, specifically for transient electronics. The next key challenge is providing stable electrical contacts since a strong adhesion between MoS2 and contacts is crucial for durability without compromising flexibility. Another challenge is the lack of tunable degradation, and the fabricated sensor lifespan cannot be precisely controlled. Finally, a full-cycle study and waste management are necessary to evaluate disposal or recycling methods for the fabrication of sensors.
Conclusion
This paper presents a promising recyclable pressure sensor incorporating 2D MoS2 as the functional material and water-soluble polyvinyl alcohol (PVA) polymer. The developed recyclable pressure sensor presents a promising avenue for sustainable electronics. The fabricated sensor exhibits piezoresistive behavior and demonstrates good performance across various pressures, with excellent sensitivity of 0.87 kPa−1 and durability. Moreover, the sensor versatility is showcased through its application in detecting radial and carotid artery pulses, monitoring air pressures, and serving as directional keys for a gaming console. Its stable performance over three months and successful application in real-time scenarios highlight its practicality and reliability. The ability to fully dissolve the sensor in water and fabricate a recycled version with negligible performance degradation underscores its potential for sustainable use. This innovative approach reduces material wastage and offers a viable solution for environmentally friendly wearable electronics, paving the way for future research and development in sustainable electronic devices.
Author contributions
Naveen Bokka: conceptualization, data curation, formal analysis, investigation, methodology, visualization, writing – original draft. Nongthombam Joychandra Singh: data curation, formal analysis, visualization, writing. Chandra Sekhar Reddy K.: methodology, writing – review and editing. Parikshit Sahatiya: supervision, formal analysis, funding, writing – review and editing.
Data availability
The data supporting this article are included within the manuscript.
Conflicts of interest
There are no conflicts to declare.
Acknowledgements
PS acknowledges the Central Analytical Laboratory, BITS Pilani Hyderabad Campus, for assistance with material characterization.
References
- Z. Nazari and P. Musilek, Impact of digital transformation on the energy sector: a review, Algorithms, 2023, 16(4), 211 CrossRef.
- M. Javaid, A. Haleem, S. Rab, R. P. Singh and R. Suman, Sensors for daily life: a review, Sens. Int., 2021, 2, 100121 CrossRef.
- N. Bokka, V. Selamneni, V. Adepu, S. Jajjara and P. Sahatiya, Water soluble flexible and wearable electronic devices: a review, Flexible Printed Electron., 2021, 6(4), 043006 CrossRef CAS.
- S. S. V. Vuppaladadiyam, B. S. Thomas, C. Kundu, A. K. Vuppaladadiyam, H. Duan and S. Bhattacharya, Can e-waste recycling provide a solution to the scarcity of rare earth metals? An overview of e-waste recycling methods, Sci. Total Environ., 2024, 924, 171453 CrossRef CAS PubMed.
- S. Manfredi, D. Tonini and T. H. Christensen, Contribution of individual waste fractions to the environmental impacts from landfilling of municipal solid waste, Waste Manage., 2010, 30(3), 433–440 CrossRef CAS PubMed.
- M. A. Mir and S. K. Chang, Saudi Arabia E-waste management strategies, challenges and opportunities, effect on health and environment: a strategic review, Emerging Contam., 2024, 100357 CrossRef.
-
V. Forti, C. P. Baldé, R. Kuehr and G. Bel, The global e-waste monitor 2020, United Nations University (UNU), International Telecommunication Union (ITU) & International Solid Waste Association (ISWA), Bonn/Geneva/Rotterdam, 2020, p. 120 Search PubMed.
- N. Bokka, V. Selamneni and P. Sahatiya, A water destructible SnS 2 QD/PVA film based transient multifunctional sensor and machine learning assisted stimulus identification for non-invasive personal care diagnostics, Mater. Adv., 2020, 1(8), 2818–2830 RSC.
- Y. Choi, J. Koo and J. A. Rogers, Inorganic materials for transient electronics in biomedical applications, MRS Bull., 2020, 45(2), 103–112 CrossRef.
- N. Bokka, G. Khush Mahendrakumar and P. Sahatiya, A water-soluble micropatterned MoS2 quantum dots/polyvinyl alcohol film as a transient contact (pressure) and non-contact (humidity) as touch and proximity sensor, J. Appl. Polym. Sci., 2022, 139(9), 51711 CrossRef CAS.
- Z. Wei, Z. Xue and Q. Guo, Recent progress on bioresorbable passive electronic devices and systems, Micromachines, 2021, 12(6), 600 CrossRef PubMed.
- J. Xu, H. Guo, H. Ding, Q. Wang, Z. Tang, Z. Li and G. Sun, Printable and recyclable conductive ink based on a liquid metal with excellent surface wettability for flexible electronics, ACS Appl. Mater. Interfaces, 2021, 13(6), 7443–7452 CrossRef CAS PubMed.
- N. X. Williams, G. Bullard, N. Brooke, M. J. Therien and A. D. Franklin, Printable and recyclable carbon electronics using crystalline nanocellulose dielectrics, Nat. Electron., 2021, 4(4), 261–268 CrossRef CAS PubMed.
- Y. Liu, H. Wang and Y. Zhu, Recycling of nanowire percolation network for sustainable soft electronics, Adv. Electron. Mater., 2021, 7(9), 2100588 CrossRef CAS.
- Y. Guo, S. Chen, L. Sun, L. Yang, L. Zhang, J. Lou and Z. You, Degradable and fully recyclable dynamic thermoset elastomer for 3D-printed wearable electronics, Adv. Funct. Mater., 2021, 31(9), 2009799 CrossRef CAS.
- T. Ye, F. Xiu, S. Cheng, C. Ban, Z. Tian, Y. Chen and W. Huang, Recyclable and flexible dual-mode electronics with light and heat management, ACS Nano, 2020, 14(6), 6707–6714 CrossRef CAS PubMed.
- M. Tavakoli, P. Alhais Lopes, A. Hajalilou, A. F. Silva, M. Reis Carneiro, J. Carvalheiro and A. T. de Almeida, 3R Electronics: Scalable Fabrication of Resilient, Repairable, and Recyclable Soft-Matter Electronics, Adv. Mater., 2022, 34(31), 2203266 CrossRef CAS PubMed.
- N. Bokka, V. Adepu, A. Tiwari, S. Kanungo and P. Sahatiya, A detailed comparative performance analysis of the Transition Metal Di-chalcogenides (TMDs) based strain sensors through experimental realisations and first principle calculations, FlatChem, 2022, 32, 100344 CrossRef CAS.
- R. Qin, X. Li, M. Hu, G. Shan, R. Seeram and M. Yin, Preparation of high-performance MXene/PVA-based flexible pressure sensors with adjustable sensitivity and sensing range, Sens. Actuators, A, 2022, 338, 113458 CrossRef CAS.
- D. Thakur, C. Porwal, V. S. Chauhan, V. Balakrishnan and R. Vaish, 2D transition metal Dichalcogenides: Synthesis methods and their pivotal role in Photo, Piezo, and photo-piezocatalytic processes, Sep. Purif. Technol., 2024, 337, 126462 CrossRef CAS.
- N. Bokka, J. Karhade and P. Sahatiya, Deep learning enabled classification of real-time respiration signals acquired by MoSSe quantum dot-based flexible sensors, J. Mater. Chem. B, 2021, 9(34), 6870–6880 RSC.
- R. Wu, H. Zhang, H. Ma, B. Zhao, W. Li, Y. Chen and X. Duan, Synthesis, modulation, and application of two-dimensional TMD heterostructures, Chem. Rev., 2024, 124(17), 10112–10191 CrossRef CAS.
- M. Teodorescu, M. Bercea and S. Morariu, Biomaterials of poly(vinyl alcohol) and natural polymers, Polym. Rev., 2018, 58(2), 247–287 CrossRef CAS.
- E. S. Marín Cardona, J. J. Rojas Camargo and Y. A. Ciro Monsalve, A review of polyvinyl alcohol derivatives: promising materials for pharmaceutical & biomedical applications, Afr. J. Pharm. Pharmacol., 2014, 674–684 Search PubMed.
- V. Selamneni, K. Gohel, N. Bokka, S. Sharma and P. Sahatiya, MoS2-Based Multifunctional Sensor for Both Chemical and Physical Stimuli and Their Classification Using Machine Learning Algorithms, IEEE Sens. J., 2020, 21(3), 3694–3701 Search PubMed.
- S. Siraj, G. Bansal, B. Hasita, S. Srungaram, S. K. S, F. J. Rybicki and P. Sahatiya, MXene/MoS2 piezotronic acetone gas sensor for management of diabetes, ACS Appl. Nano Mater., 2024, 7(10), 11350–11361 CrossRef CAS.
- G. M. Janeesh, V. Meera, A. M. Shalom, D. Rajan Babu, N. A. Nambi Raj, M. S. Sreekanth and T. P. Sumangala, Enhanced electrical conductivity and structural, mechanical characterization of standalone poly(vinyl alcohol)-graphite nanoplatelets composite films, J. Appl. Polym. Sci., 2021, 138(10), 49976 CrossRef CAS.
- K. Iritani, A. Nakanishi, A. Ota and T. Yamashita, Fabrication of Novel Functional Cell-Plastic Using Polyvinyl Alcohol: Effects of Cross-Linking Structure and Mixing Ratio of Components on the Mechanical and Thermal Properties, Global Challenges, 2021, 5(8), 2100026 CrossRef PubMed.
- N. Bokka and P. Sahatiya, Heat and light triggered mechanical destruction of 2D materials based electronic devices fabricated on wax substrate, FlatChem, 2022, 35, 100423 CrossRef CAS.
- T. R. Malagrino, A. P. Godoy, J. M. Barbosa, A. G. Lima, N. C. Sousa, J. J. Pedrotti and J. Taha-Tijerina, Multifunctional hybrid MoS2-PEGylated/Au nanostructures with potential theranostic applications in biomedicine, Nanomaterials, 2022, 12(12), 2053 CrossRef CAS PubMed.
- F. J. Zhang, X. Li, X. Y. Sun, C. Kong, W. J. Xie, Z. Li and J. Liu, Surface partially oxidized MoS2 nanosheets as a higher efficient cocatalyst for photocatalytic hydrogen production, Appl. Surf. Sci., 2019, 487, 734–742 CrossRef CAS.
- R. Qin, J. Nong, K. Wang, Y. Liu, S. Zhou, M. Hu and G. Shan, Recent advances in flexible pressure sensors based on MXene materials, Adv. Mater., 2024, 36(24), 2312761 CrossRef CAS PubMed.
- L. Han, W. Zeng, Y. Dong, X. Wang and L. Lin, Mapping and Simultaneous Detection of Arterial and Venous Pulses using Large-Scale High-Density Flexible Piezoelectret Sensor Array, Adv. Electron. Mater., 2022, 8(9), 2200012 CAS.
- J. Chen, K. Sun, R. Zheng, Y. Sun, H. Yang, Y. Zhong and X. Li, Three-dimensional arterial pulse signal acquisition in time domain using flexible pressure-sensor dense arrays, Micromachines, 2021, 12(5), 569 Search PubMed.
- Y. C. Huang, Y. H. Chang, S. M. Cheng, S. J. S. Lin, C. J. Lin and Y. C. Su, Applying pulse spectrum analysis to facilitate the diagnosis of coronary artery disease, J. Evidence-Based Complementary Altern. Med., 2019, 2019(1), 2709486 Search PubMed.
- J. Wang, G. Xia, L. Xia, Y. Chen, Q. Li, H. Zeng and Y. Chen, HCNT/AgNPs/PVA/PAM hydrogel-based flexible pressure sensor for physiological monitoring, J. Mater. Sci.: Mater. Electron., 2024, 35(29), 1931 CrossRef CAS.
- T. Zhao, J. Lv, B. Liu, H. Zhu and H. Zhang, A highly sensitive flexible pressure sensor based on laser-induced graphene and a composite dielectric structure, Sens. Actuators, A, 2023, 358, 114460 CrossRef CAS.
- H. Guan, J. Meng, Z. Cheng and X. Wang, Processing natural wood into a high-performance flexible pressure sensor, ACS Appl. Mater. Interfaces, 2020, 12(41), 46357–46365 CrossRef CAS.
- K. Cao, M. Wu, J. Bai, Z. Wen, J. Zhang, T. Wang and L. Jiang, Beyond skin pressure sensing: 3D printed laminated graphene pressure sensing material combines extremely low detection limits with wide detection range, Adv. Funct. Mater., 2022, 32(28), 2202360 CrossRef CAS.
- M. Yang, Y. Cheng, Y. Yue, Y. Chen, H. Gao, L. Li and Y. Gao, High-performance flexible pressure sensor with a self-healing function for tactile feedback, Adv. Sci., 2022, 9(20), 2200507 CrossRef CAS PubMed.
- F. Huang, G. Hu, Z. Yu, Y. Pan, H. Yao, C. Tang and H. Zhang, Highly sensitive and wide linearity flexible pressure sensor with randomly distributed columnar arrays, J. Mater. Sci., 2023, 58(8), 3735–3751 CrossRef CAS.
- Y. Li, Y. Cui, M. Zhang, X. Li, R. Li, W. Si and C. Huang, Ultrasensitive pressure sensor sponge using liquid metal modulated nitrogen-doped graphene nanosheets, Nano Lett., 2022, 22(7), 2817–2825 CrossRef CAS PubMed.
- Q. Yue, S. Xiao, Z. Li, J. Yang, B. Chen, J. Feng and T. Wang, Ultra-sensitive pressure sensors based on large alveolar deep tooth electrode structures with greatly stretchable oriented fiber membrane, Chem. Eng. J., 2022, 443, 136370 CrossRef CAS.
- Y. Lv, L. Min, F. Niu, X. Chen, B. Zhao, Y. Liu and K. Pan, Wrinkle-structured MXene film assists flexible pressure sensors with superhigh sensitivity and ultrawide detection range, Nanocomposites, 2022, 8(1), 81–94 CrossRef CAS.
|
This journal is © The Royal Society of Chemistry 2025 |
Click here to see how this site uses Cookies. View our privacy policy here.