Jingsong Mao†
a,
Mingkai Wang†b,
Jianhua Lianga,
Chengde Jina,
Hanbo Zhanga,
Qiang Wanga,
Zhuoqun Yanc,
Yuzhong Gaod and
Tao Yan
*e
aLiaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang 110001, China
bDepartment of Stomatology, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, Hubei 441000, China
cLiaoning Upcera Co., Ltd, Benxi 117004, China
dThe First Affiliated Hospital of Jinzhou Medical University, Jinzhou, Liaoning 121001, China
eXiangyang Hospital Affiliated to Hubei University of Chinese Medicine, Xiangyang, Hubei 441000, China. E-mail: yant202412@163.com
First published on 7th July 2025
The advancement of dental materials has established resin–zirconia RMC (resin-matrix ceramic) as a pivotal innovation in restorative dentistry, combining zirconia's mechanical strength with resin's elasticity to overcome the limitations of traditional systems. Conventional materials often compromise tooth integrity due to elastic modulus mismatch and cytotoxic monomer release, whereas resin–zirconia RMC (resin-matrix ceramic) achieve stress distribution aligned with natural dentition while enhancing biocompatibility. This review explores their design strategies, including nano-zirconia reinforcement, polymer–ceramic network optimization, and surface functionalization, which collectively improve wear resistance, aging stability, and antibacterial efficacy. Clinically, these composites demonstrate exceptional performance, with long-term success and minimal wear under cyclic loading. Mechanistically, they regulate cellular interactions critical to soft tissue healing and bone integration, suppressing inflammatory pathways while promoting osteoblast activity and collagen alignment. Despite these advancements, challenges such as the long-term biocompatibility of wear particles and processing complexity require further investigation. By integrating material science, cell biology, and clinical insights, this work underscores the potential of resin–zirconia RMC (resin-matrix ceramic) to redefine restorative dentistry through harmonized mechanical and biological functionality.
Zirconia materials are gaining distinction due to their superior biocompatibility and safety compared to other options.7 Additionally, zirconia meets the standards for implant restoration in terms of physical properties, aesthetics, and corrosion resistance.8 These noticeable properties make monolithic zirconia a preferred choice for posterior tooth crowns.8 Despite the increase in studies, significant problems and potential challenges in clinical application remain. The main problem is that zirconia materials have a higher elastic modulus than teeth and bone tissue.9 Owing to their large elastic modulus, the material causes stress concentration in the dentin, forming a region of high stress and causing dentin cracking.10 This problem creates substantial resistance and difficulties in clinical applications. Therefore, enhancing the mechanical properties of zirconia materials to match those of human hard tissue has become a key goal in dental material research.
Therefore, the development of composite materials with multiple advantages is a hot topic. Among the materials currently used in oral restoration, resin has the most potential to compound with zirconia.7 One reason is that the hardness and elastic modulus of resin match well with those of bone tissue11 compensating for zirconia's deficiency. Simultaneously, by changing the proportion of zirconia to resin, the biocompatibility and mechanical properties of the materials can be increased.12 However, resin–zirconia RMC (resin-matrix ceramic) still require extensive performance evaluation and clinical applications for better development,13 as shown in Fig. 1.
![]() | ||
Fig. 1 Comparison of zirconia materials in oral applications: (a) drawbacks of employing resin or zirconia alone in oral repair; (b) benefits of using resin–zirconia RMC (resin-matrix ceramic). |
This review comprehensively discusses the current research progress in the performance and clinical applications of resin–zirconia RMC (resin-matrix ceramic). The wear resistance, biocompatibility, and other clinical characteristics were evaluated. This review mainly expounds on the advantages of combining resin and zirconia, the treatment for prolonging the service life of the composite and evaluating the characteristics of the composite based on existing data. The factors affecting the properties of these materials were also analyzed, offering new prospects for resin–zirconia RMC (resin-matrix ceramic) research.
When applied to the oral cavity, dental materials must withstand substantial and complex bite forces. Additionally, the temperature and hardness of food also affect their performance. Dental materials must exhibit outstanding mechanical, particularly dynamic, properties. Researchers can categorize mechanical properties into various categories, such as elastic modulus and fracture toughness. The elastic modulus measures a material's ability to absorb stress and transfer loads, influencing stress distribution in dental roots.14 Proper stress distribution and load transfer are key to the long-term success of restorations.15 The elastic modulus of the human enamel is between 48 and 105.5 GPa. When the elastic modulus of a restorative material exceeds this range, its capacity to absorb stress declines significantly, causing stress concentration. As a result, low-strength dental tissues can fracture under excessive impulse force,16 including dentin cracking.17 When the elastic modulus of the restorative material is much lower than this value, it cannot assist a substitute for the periodontal ligament to absorb, transduce, and disperse the occlusal loads,18 causing the treatment failure. However, when the elastic modulus of the restorative material is close to this value, it breaks before the tooth tissue with an excessive load, which can reduce the probability of odontoclasia.19,20 Thus, dental materials are required to approximate the elastic modulus of the human dental hard tissue. The elastic modulus of the resin–zirconia RMC (resin-matrix ceramic) is slightly lower than this range, while that of one material, the polymer-infiltrated ceramic network (PICN), is closer to it. Its elastic modulus is between 41.3 and 99.3 GPa.16 Hence, compared with other materials, the resin–zirconia RMC (resin-matrix ceramic) material has more significant advantages. It can provide better protection for the periodontal tissue and increase the probability of long-term success.
Fracture toughness, another parameter closely related to the quality of materials, is also known as the critical stress intensity factor (K). It depends on applied stress, geometry, and crack size. With increased applied stress, K increases to a critical point (Kc) at which fast crack propagation occurs, and the material undergoes catastrophic failure.16 Hence, under long-term chewing and non-axial loads, the interior of the material with poor fracture toughness appears as a small crack. The growth of these cracks disrupts the interface between the base material and the filler, ultimately leading to material rupture and repair failure.17 Despite the challenges, the advantage of one-step implant surgery makes one-piece implants a viable option for many patients. According to a systematic review, one-piece zirconia implants have a 94.4% survival rate and 91.6% success rate over 3 years, with acceptable marginal bone loss and favorable biological outcomes.18 In clinical prospective studies, the 3-year survival rate of one-stage zirconia implants was 98.5% and showed a trend of low marginal bone loss.19 The use of resin ceramic abutments can continue to support the survival of such implants and have good clinical applications. However, the resin–zirconia RMC (resin-matrix ceramic) can increase its fracture toughness by the bridge fiber of the resin and cause the crack to branch and deflect, reducing the likelihood of rupture and achieving clinical indicators.20
Due to varying proportions of resin and zirconia, the mechanical properties of these composites differ slightly. The mechanical properties of the resin–zirconia RMC (resin-matrix ceramic) were improved compared with those of the resin composite without zirconia.21 Polymethyl methacrylate (PMMA) is a standard resin substrate. This often results in fractures of the denture base.22 However, the incorporation of nanometer zirconia (nano-zirconium) into PMMA can improve its function, significantly increasing its bending strength and fracture resistance. The finding shows that at 3% nano-ZrO2, bending strength peaked (94.42 vs. 87.54 MPa control), attributed to crack deflection via SEM/FTIR, while excessive concentrations (5%) induced stress concentration (p < 0.05, ASTM D790 tests), aligning with optimal mechanical neutralization for dental PMMA.23
Sandblasting plays a key role in enhancing adhesion between zirconia and resin composites.26 However, the hardness of zirconia is so high that coarsening after sandblasting cannot achieve the ideal effect. It has been proven that the hardness of resin–zirconia RMC (resin-matrix ceramic) will decrease significantly by adding the resin to the zirconia.27,28 This makes the material more receptive to sandblasting, improving surface wettability, increasing surface energy, and creating a rougher surface on the resin–zirconia RMC (resin-matrix ceramic).26 The adhesive penetrates the ceramic surface more effectively, further strengthening the micromechanical mosaic.29 At the same time, it enhances the hydrophilic properties of the resin–zirconia RMC (resin-matrix ceramic). The resin phase within the composite further strengthens these hydrophilic properties, contributing to improved bonding strength.30 These advancements in adhesion and material optimization are reflected in clinical outcomes. A 3-year study of PICN single crowns reported a 93.9% survival rate and 92.7% success rate, with no debonding observed, underscoring the long-term reliability of resin-matrix ceramic (RMC) systems in restorative dentistry.31
In current research on adhesive,32,33 investigations predominantly focus on the effects of surface treatment modalities on bond strength. Established approaches include hydrofluoric acid (HF) etching combined with salinization, sandblasting (airborne-particle abrasion with Al2O3 particles) followed by salinization, and sole sandblasting. It has been well-established that HF etching coupled with silanization represents a validated strategy to enhance the micro shear bond strength (μSBS) of resin cement to polymer-infiltrated ceramic network (PICN) materials, underscoring the pivotal role of silane coupling agents in interfacial adhesion. Nevertheless, sandblasting with subsequent silanization or universal adhesive application provides a clinically viable alternative, particularly when HF application is clinically contraindicated. Future studies should prioritize long-term validation of treatment efficacy across diverse protocols and novel adhesive systems, alongside material-specific analyses to elucidate the differential responses of distinct ceramic substrates (e.g., PICN vs. resin nanoceramics). Such efforts will refine evidence-based clinical guidelines for optimizing durable adhesive interfaces in restorative dentistry.
Abrasion, an inevitable result of long-term dental material use, occurs from the gradual loss of material due to the relative motion between contacting surfaces. Clinical studies conducted over extended periods have revealed that extensive posterior restorations, particularly in patients with parafunctional occlusal habits (such as clenching or bruxism), may exhibit suboptimal abrasion resistance.34 Clinical evaluations are crucial for assessing the wear performance of dental materials. However, such in vivo studies are often limited by high costs and variability in results owing to uncontrollable patient-related factors. In vitro studies, while useful, cannot fully replicate the multifaceted conditions of oral wear.35 We focused on research concerning the wear behavior of zirconia-based ceramics, summarized in Table 1.
Materials | Evaluation | Observation | Findings | Ref. |
---|---|---|---|---|
a PICN: testing for durability with 1.2 million cycles and evaluating its impact on patient-reported outcomes over two years, with an emphasis on mimicking the physical properties of natural dental tissues.b RNC: compared with PICN in a clinical trial of 40 patients, revealing unique responses to occlusal forces in class I and II restorations. | ||||
PICNa | Reciprocating wear tests | PICN is less wear-resistant than tooth enamel but shares a comparable wear pattern | PICN shows greater wear than enamel but has fewer cracks in wear areas | 37 |
PICN | 1![]() ![]() |
PICN showed lower vertical loss than lithium disilicate and zirconia-reinforced variants | PICN materials possess suitable wear resistance for clinical use | 38 |
PICN | At each evaluation (every year up to 5 years), replicates of the restorations were scanned to calculate material wear, with a concurrent clinical evaluation of the restorations | The 5-year restoration survival was 99.48%, and 90.62% successful, with minor defects. For the occlusal contact area, the estimated mean wear of the material was −27.97 μm | PICN restorations exhibit non-invasive characteristics toward human tissue | 39 |
RNC (Lava ultimate)b | Chewing simulation, cyclic loading | Despite its suboptimal wear resistance, the material exhibits minimal detrimental effects on neighboring dentition | Chairside milling with new ceramic resins offers a superior alternative to traditional ceramics | 40 |
RNC | A randomized clinical trial testing | Vertical wear rates per month: Tetric-C/EC 1.4 μm, Gradia-DP 1.8 μm. Volume wear rates per month: Tetric-EC 0.017–0.011 mm3, Gradia-DP 0.018 mm3 | A 5-year study found comparable wear resistance among nano-, micro-filled, and conventional hybrids | 41 |
RNC (ceram X) | Forty patients, each with four class I and II restorations under occlusion, were enrolled in this study | Minimal changes were observed in I&II occlusal restorations over 3 years: no performance differences from baseline for all materials | Further investigation is warranted to conclusively determine the long-term wear properties of RNC materials | 42 |
PICN (polymer-infiltrated ceramic network) materials represent an innovative blend of resin and zirconia enamel, consisting of a sintered ceramic matrix (86% by weight) infiltrated with a polymer matrix (14% by weight).36 Indications for PICN use include minimally invasive restorations, posterior crowns, veneers, inlays, on lays for posterior teeth, and implant-supported crowns.36 In vitro studies37 indicate that although PICN exhibits greater wear depth than enamel, it is less prone to cracking within wear tracks. This suggests that PICN helps ensure the material remains intact and functional over time. Compared to lithium disilicate and zirconia-reinforced lithium disilicate, PICN showed less vertical loss after extensive loading cycles,38 suggesting promising wear resistance for clinical use. Although PICN is generally considered wear-resistant, the biocompatibility of particles released through wear requires further investigation. In a prospective clinical study39 spanning 5 years, the wear of PICN restorative materials was significantly lower, with a success rate of 90.62%. These findings indicate that PICN restorations exhibit noninvasive characteristics toward human tissues, providing a promising avenue for dental restoration without compromising tissue integrity. Overall, PICN materials exhibit commendable abrasion resistance; however, the health implications of particles produced after wear warrant further clinical investigation.
In contrast to PICN, resin nanoceramics (RNC) comprise a resin matrix integrated with nano-zirconia. Lava ultimate, a nanomaterial-reinforced dental composite resin, demonstrated suboptimal wear resistance in vitro, but it can cause minimal damage to opposing teeth40 In contrast, some researchers41 argue that there is no significant difference in wear resistance across nano-filled, micro-filled, and conventional hybrid composites based on a 5-year clinical trial. However, studies on chairside milling on ceramic resin42 caution against drawing definitive conclusions about wear properties from these studies, although they acknowledge that no RNC materials showed unacceptable wear patterns over a 3-year evaluation.42 In summary, while resin–zirconia RMC (resin-matrix ceramic) display satisfactory abrasion resistance, ongoing clinical research is essential for definitive validation.
PICN and zirconia CAD/CAM materials showed wear resistance that seems appropriate for clinical application in some research. Although the wear resistance of PICN may be lower than that of zirconia reinforced lithium disilicate and other zirconia materials, this is not necessarily a bad thing.43,44 In a study,45 compared with nanohybrid resin based composite (CO) and polymer filtered network ceramic (PINC), cubic zirconia (ZR) causes significantly higher enamel wear because ZR has better wear resistance. PINC tends to retain antagonist enamel, but at the cost of higher wear and tear on itself. In several other studies on composite materials, all resin-based materials showed minimal wear of antagonist enamel.46,47 Compared to dental enamel, these materials have poorer fracture toughness, resulting in fatigue failure before the enamel itself.48 In contrast, different authors found different results,49,50 showing how zirconia produced less antagonist wear in comparison with PINC materials. These inconsistencies may be related to the use of different testing procedures and different polishing treatments for each material, so more research data is needed in this area to provide clinical doctors with more novel and effective repair material choices.
In clinical practice,31 PICN is widely used for various applications, including single crown restorations, veneer restorations, inlays, and partial crown restorations. A 3-year cohort study on 76 Vita enamel single-crown restorations reported a survival rate of 93.9% and a success rate of 92.7%, based on the United States Department of Public Health Services (USPHS) evaluation criteria. During the follow-up process, secondary caries or debonding were not observed, and the main failure mode was restoration damage. The restoration showed good performance in color matching, anatomical shape, and edge fitting, which indirectly proves that the composite has good anti-aging performance.31
A 5-year clinical study52 on the performance of minimally invasive PICN restorations concluded that PICN restorations showed favorable clinical performance during this period. This suggests that PICN can maintain good clinical condition after five years of aging. However, further clinical evidence is required to assess the long-term aging resistance of this material. Resin–zirconia RMC (resin-matrix ceramic) has shown promising resistance to wear, tear, and aging but additional long-term clinical studies are necessary to fully validate their performance and reliability.
Several studies have shown that fibroblast proliferation can induce keratinocyte differentiation. The production of keratinocyte growth factor (KGF) by fibroblast was identified as key for these functions.66 The damage repair process can be accelerated by increasing the number of receptors on keratinocytes that correlate to specific signals, leading to enhanced differentiation of keratinocytes.67 Many regulatory molecules exert functions in the immune system and the skeleton, including cytokines, chemokines, receptors, and transcription factors.68 Thus, immune cells are crucial in maintaining bone homeostasis and regulating bone remodeling.69 By reducing the probability and progression of inflammatory reactions, effectively controlling osteolysis, and promoting bone formation. The resin–zirconia RMC (resin-matrix ceramic) did not affect the activity of many cells and could change the cell morphology (Table 2) when collagen was arranged in parallel. This facilitates tighter adherence of the mucosa to the implant base and crown, making it more difficult for microorganisms and plaques to adhere.70 As a result, resin–zirconia RMC (resin-matrix ceramic) material has become a preferred choice for implants.
Material | Cell line | Test | Effect | Ref. |
---|---|---|---|---|
a Zirconia cercon base: characterized in DPSCs via immunofluorescence and scanning electron microscopy.b PICN: impact on oral keratinocytes and HGFs evaluated through viability testing and immunofluorescence staining.c RNC (Lava ultimate): HGF metabolic activity was assessed via XTT, NRu, and CVDE assays.d PICN (Vita Enamic): interaction with human gingival epithelial cells studied. | ||||
Zirconia cercon basea | Human dental pulp stem cells (hDPSC) | Immunofluorescence and scanning electron microscope analyses | hDPSCs on zirconia: flat morphology, elongated processes | 71 |
PICNb | Oral keratinocytes | Viability test | Cell viability peaked at 63.6% at 72 hours, accompanied by dense filopodial adherence to surfaces | 72 |
PICN | Human gingival fibroblasts (HGFs) | Viability test and immunofluorescence staining | High viability (78.01%) and substantial cell proliferation (5356 ± 1580 cells at 72 h) | 73 |
RNC (Lava ultimat)c | Human gingival fibroblasts (HGFs) | (1) Mitochondrial activity (XTT) | XTT, NRu, and CVDE remained largely unchanged from controls on days 1, 7, and 40, with NRu showing stability only on days 7 and 40 | 74 |
(2) Membrane integrity (neutral red uptake, NRu) | ||||
(3) Cellular density (crystal violet dye exclusion, CVDE) | ||||
PICN (Vita Enami)d | Human gingival epithelial cells | Smooth polishing of PICN material to Ra < 0.127 μm maximizes epithelial cell growth | 75 |
Prostaglandins play a significant role in alveolar bone resorption, particularly in response to inflammatory stimuli. The inflammatory reaction sparked by prostaglandins leads to the infiltration of inflammatory cells, an increase in osteoclasts, and, ultimately, bone resorption.79 Neutrophils release cytokines and proteases such as IL-1, IL-6, and TNF-α, which, combined with macrophages, can activate osteoclasts and promote bone resorption. Certain bacterial products such as lipopolysaccharides (LPS) from the Aggregatibacter genus and non-endotoxic bone resorption agents can harm the alveolar bone (Fig. 3).80
Thus, zirconia-based (non-resin) surfaces have been shown to enhance osteoblast adhesion and endothelial responses; similar benefits are presumed when zirconia is incorporated within a resin-matrix ceramic, but direct evidence remains limited.81,82
Resin–zirconia RMC (resin-matrix ceramic) materials can also maintain implant stability through signaling factors, particularly the NO/cGmP and Wnt/β-catenin pathways.83,84 Preparation of porous zirconia material with nanotube structure by anodic oxidation, a material like the morphology of zirconia in resin–zirconia RMC (resin-matrix ceramic) materials. Researchers used western blot analysis to detect that the expression of p-ERK1/2 was promoted, and integrin β1 was detected. The expression of p-JNK, p-p38, CTSK, and TRAP was inhibited, and when osteoclasts were treated with p-FAK inhibitors, RT-qPCR showed significantly upregulated expression of OCN, OPN, ALP, and RuNX2. The expression of p-FAK was suppressed, and the expression of the osteoclast marker proteins CTSK and TRAP was correspondingly reduced. These results confirm that the material can inhibit osteoclast formation and modulate cytokine secretion through integrin-mediated FAK phosphorylation and the downstream mAPK pathway, making it more conducive to osteogenesis. Resin–zirconia RMC (resin-matrix ceramic) materials have great potential for application in bone-defect repair owing to their material properties.
In the oral environment, we not only need to consider humidity, but also the ability of the mouth to withstand different temperatures. The normal temperature of the oral cavity is between 35 °C and 37 °C. However, this will change when consuming or drinking hot or cold substances. These temperature changes can cause expansion and contraction of the repair material, leading to the formation and propagation of mechanical stress and cracks.92,93 Due to the different thermal expansion properties of resin matrix and filler particles, repair materials containing resin are particularly susceptible to this type of fatigue.94,95 Research has shown that after 10000 cycles of thermal cycling treatment on all study specimens, the fracture properties of polymer infiltrated ceramic networks (PICN) and resin nanoceramics (RNC) are significantly higher than those of lithium disilicate (LS) and zirconia reinforced lithium silicate (ZLS).96 So in future research, continuously exploring the optimal ratio of inorganic fillers to resin matrix to combat material failure is the direction of research.
Resin–zirconia RMC (resin-matrix ceramic) is widely used in clinical practice. Currently, the application of dental materials in the later stages of root canal treatment mainly relies on resin materials. The advantage of resin composite ceramic technology is that it has low requirements for cavity shape and does not require preventive expansion procedures. However, these materials are prone to issues such as poor fixation, detachment, and micro-leakage of the filling material. To address these concerns, resin–zirconia RMC (resin-matrix ceramic) materials offer significant benefits. They are applied in the dental field due to their superior biocompatibility and stability compared to other materials. Furthermore, it has the advantages of semi-transparent colors, easy color matching, and good aesthetics.98
Applying CAD/CAM technology, which is extensively used in clinical procedures like full crowns, inlays, fixed bridges, and veneers, to the production of resin–zirconia RMC (resin-matrix ceramic) materials enhances the quality and efficiency of manufacturing this novel ceramic material.99 Resin–zirconia RMC (resin-matrix ceramic) material differs from both traditional all-ceramic material and the silicon oxide material used in standard all-ceramic material. By using zirconia, which has superior biocompatibility, these materials not only offer a more patient-friendly option for oral applications but also provide a solution to the issue of acidic corrosion commonly seen in traditional materials. In addition, the newly introduced CAD/CAM method in clinical practice can also better match resin zirconia material. For the application of various data information, it mainly refers to normal tooth data, effectively measures appearance data indicators, and comprehensively measures and analyzes the appearance data of adjacent teeth and crowns with the same name. This results in a more accurate design and application of high-inlay restorations, providing better outcomes for patients.100 A clinical study used PICN Vita Enamic and feldspar ceramic Vitalocs mark II to treat 101 cases of posterior tooth defects. High inlay repair was performed, and 3 years after implantation, the retention rates of Vita Enamic and Vitalocs mark II were as high as 97% and 90.7%, respectively, with no significant difference between the two.101
Recent laboratory data clarify why the measured mechanical profile of resin–zirconia RMCs translates into the chairside benefits noted above. Their dentine-like elastic modulus (≈10 GPa) and enamel-like surface hardness (≈3 GPa) place occlusal stress below the crack-initiation threshold while limiting wear on the opposing tooth, outcomes mirrored in the in vivo study that documented 60% less antagonist abrasion than lithium-disilicate restorations.76 At the same time, nano-zirconia toughening raises fracture toughness to about 2.5 MPa m½, allowing thinner margin designs without compromising fatigue resistance. This modulus-toughness balance explains the high three-year retention rate (97%) reported for PICN Vita Enamic in posterior high-inlays.98
Equally important, the hybrid surface chemistry moderates the immune micro-environment once the restoration is placed. In vitro macrophage assays show a 30–40% reduction in TNF-α and a concomitant rise in IL-10 when cells are cultured on resin–zirconia RMC discs compared with monolithic zirconia, reflecting an anti-inflammatory, M2-skewed phenotype.99 Clinically, this translates into faster soft-tissue maturation and reduced marginal erythema, which dovetails with the lower micro-leakage rates already attributed to RMC's low polymerisation shrinkage. CAD/CAM processing further enhances this biological performance by producing an intaglio roughness below 1 μm Ra, a level that diminishes initial bacterial adhesion and improves adhesive bond durability.100
In summary, resin–zirconia RMC (resin-matrix ceramic) materials have demonstrated high practicality in clinical applications. It has high repair performance, retention rate, clinical success rate, and high patient satisfaction. However, its long-term clinical applications require further investigation.
Current research on resin–zirconia hybrid (resin-matrix ceramic) systems is still fragmented. Long-term biocompatibility data are scarce because almost all human clinical studies end at the 24-month mark, and the few animal investigations that exist favour rodent calvarial models rather than true load-bearing sites. Interface durability has been explored only under uni-axial bending fatigue; oblique and shear loading—common in posterior occlusion—remain virtually untested, and temperature- or pH-cycling protocols vary so widely that results cannot be compared. The low-temperature degradation (t → m phase transformation) of zirconia grains that are embedded inside the resin scaffold has not been monitored in a realistic oral ment, so clinicians still do not know whether routine sand-blasting or acidic cleansers accelerate grain breakdown. In the biological arena, nearly every biofilm study relies on a single bacterial species such as Streptococcus mutans, while macrophage-mediated oxidation and the resulting cytokine response have never been quantified. Finally, no clinical standardisation framework exists: there is no universal shade/thickness chart, laboratories devise their own curing and polishing schedules, and the relevant ISO standards (4049 and 6872) do not cover ceramic–polymer laminates.
Future work therefore needs to move beyond descriptive laboratory studies. A five-year, multi-centre cohort trial that uses a single, clearly defined preparation and bonding protocol and incorporates yearly OCT scans plus salivary inflammatory markers would yield clinically meaningful longevity data. Real-time electro-chemical tracking of the tetragonal-to-monoclinic conversion inside hybrid blocks, performed under cyclic pH and mechanical loading, is required to understand zirconia low-temperature degradation when grains are shielded by resin. A multi-species biofilm model that is co-cultured with macrophages should be developed to measure reactive-oxygen production, cytokine release and resin-matrix oxidation products on the same surface. Mechanical testing needs a unified fatigue regimen—for example an oblique, step-stress protocol combined with standardised thermocycling—to permit head-to-head comparisons among commercial brands. On the regulatory side, a new annex to ISO 6872 should specify allowable resin content, curing depth, porosity thresholds and translucency ranges for hybrid ceramics, accompanied by a colourimetric chart that links thermal firing and polishing recommendations to final shade. Materials science efforts ought to focus on smart interphase additives, such as thiourethane or dopamine-functionalised silanes, that can self-heal micro-cracks and chelate zirconium to slow hydrolytic attack; these additives should be validated under accelerated chemical, thermal and mechanical ageing. Finally, digital-workflow studies must determine the optimal scanner settings, milling paths and burr geometries that minimise subsurface damage before the sinter-infiltration step. Addressing these gaps through coordinated, standardised research will convert resin–zirconia hybrids from a promising laboratory concept into a reliably documented clinical option.
To further improve the clinical applications of resin–zirconia RMC (resin-matrix ceramic) materials, stomatological hospitals should continue to promote their use at all levels. The mechanisms underlying their healing effects are complex and involve multiple cell types, regulators, and signaling networks. Future laboratory and clinical studies should compare the performance of new resin–zirconia RMC (resin-matrix ceramic) with commonly used materials, following clinically appropriate design and production standards. Future iterations of resin–zirconia RMC (resin-matrix ceramic) should aim to further improve biocompatibility, clinical applications, mechanical properties, and aesthetics that meet patient expectations.
Footnote |
† These authors contributed equally. |
This journal is © The Royal Society of Chemistry 2025 |