Open Access Article
Wei Shan
Tan
ac,
Arthur M.
de Jong
bc and
Menno W. J.
Prins
*abcd
aDepartment of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands. E-mail: m.w.j.prins@tue.nl
bDepartment of Applied Physics and Science Education, Eindhoven University of Technology, Eindhoven, Netherlands
cInstitute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, Netherlands
dHelia Biomonitoring, Eindhoven, Netherlands
First published on 3rd November 2025
Molecular quantification using Point Accumulation for Imaging in Nanoscale Topography (PAINT) depends critically on probe kinetics, imaging conditions, and surface molecular properties. This study presents a simulation-guided framework to systematically explore the PAINT parameter space and identify conditions that enable molecular quantification with high accuracy. Detection thresholds for key PAINT outputs, namely point spread function density, localization cloud density, and binding event density, are defined to ensure ≥90% accuracy in density estimates and statistical interpretability of spatial distributions. A neural network surrogate model, trained on Monte Carlo simulations, is used to perform Sobol sensitivity analysis, revealing that probe kinetics and concentration are the dominant contributors to output variability. The model also enables rapid mapping of viable parameter regimes and shows that interpretable quantification of spatial distributions in high-density, clustered systems requires either a priori knowledge of the molecular architecture or improved spatial resolution. Overall, this framework provides quantitative guidance for optimizing PAINT experiments and supports the rational design of non-DNA-based, PAINT-compatible probes, thereby expanding the applicability of PAINT to a broader range of molecular systems.
Among these techniques, DNA-PAINT offers several advantages, including well-defined binding kinetics and relatively simple instrumental requirements. These features make it a promising candidate for high-throughput molecular quantification. DNA-PAINT has been successfully applied to both synthetic biofunctionalized surfaces (e.g., DNA origami, nanoparticles) and biological substrates, and has been used to image diverse biomolecules including nucleic acids, proteins, and lipids.5,7–11 Despite this versatility, molecular quantification using DNA-PAINT has largely been limited to low-density systems, those in which the intermolecular distances exceed the spatial resolution limit of the imaging method.
To extend DNA-PAINT to higher molecular densities, the quantitative PAINT (qPAINT) approach was developed, which infers molecular counts from hybridization kinetics in resolution-limited areas.11,12 However, qPAINT requires restrictive imaging conditions such that the occurrence of multiple binding events at any given time within the same diffraction-limited region is avoided. This constraint limits its scalability for high-throughput analysis and precludes detailed assessment of spatial molecular distributions. An alternative, Resolution Enhancement by Sequential Imaging (RESI), overcomes this limitation through DNA barcoding, but suffers from poor scalability with increasing molecular density.13 In our previous work, we introduced a simulation-based analysis framework that enables both molecular quantification and spatial distribution analysis in high-density regimes, while maintaining relatively short acquisition times.14,15
Taken together, these methodologies highlight a critical trade-off: to achieve accurate molecular quantification with high throughput, one must carefully balance probe binding kinetics and imaging parameters for the surface molecular properties under study. While DNA-PAINT benefits from predictable DNA hybridization kinetics, it also depends on tagging non-DNA targets with labeling probes, such as antibodies or nanobodies, conjugated to a DNA docking strand. These labels can introduce errors and perturb the molecular environment, potentially compromising measurement accuracy.16,17 This underscores the need for novel, non-DNA-based probes that exhibit PAINT-compatible binding kinetics. To inform the development of such probes and to guide experimental design, a deeper understanding of how PAINT experimental parameters influence quantification outcomes is essential. This study is especially relevant for biological systems with nanoscale molecular organization, including nuclear pores, focal adhesions, and immune synapses.
In this article, we present a simulation-driven strategy to systematically explore the PAINT parameter space with a focus on achieving accurate molecular quantification. We employ the ThunderSTORM simulation engine alongside custom Monte Carlo models to delineate the quantification limits for molecular density and distribution. Furthermore, we develop a neural network surrogate model to evaluate the sensitivity of PAINT outputs to individual experimental parameters. The trained model reveals optimal parameter combinations that support molecular quantification with up to 90% accuracy, and provides actionable insight into the kinetic requirements for next-generation PAINT probes.
We define PSF detection accuracy using the F1 score, which accounts for the number of true positives (TP), false positives (FP), and false negatives (FN):
![]() | (1) |
As shown in eqn (1), the F1 score reflects both recall r, the fraction of correctly identified PSFs, and precision p, the proportion of correct identifications among all localized PSFs. By varying the average PSF density
(averaged over all frames), we determined that PSFs can be detected with at least 90% accuracy up to a maximum density of σmaxPSF = 0.07 μm−2, as shown in Fig. 2(A).
In SMLM, stacking localized PSFs across time results in a spatial map known as a time-aggregated localization plot. Because the bright time, the duration a PSF is visible, typically ranges from hundreds of microseconds to several seconds, a single molecule appears as a cloud of localizations. The underlying molecular position can be estimated from the centers of these localization clouds, which are identified using clustering algorithms such as mean-shift clustering19–21 or DBSCAN.22,23 This step is critical both for direct molecular counting and for analyzing spatial distributions.
However, overlap between localization clouds, due to high cloud density σcloud or a clustered molecular distribution, can introduce errors in identifying individual localization clouds. To study this, we simulated ground truth molecular positions with predefined spatial distributions. A standardized distribution score, based on nearest-neighbor distance statistics and following the approach described in previous work,14 was used to quantify spatial distributions. Nearest-neighbor distances refer to the distances between adjacent points, where each point here represents a ground truth molecular position. Briefly, subsets of nearest neighbor distances (
1, for
1 ⊂ D1) of size m were selected to ensure independence of the nearest neighbor distances. For each subset, the mean nearest neighbor distance
was calculated and standardized against the expected mean
and standard error
under a complete spatial randomness (CSR) hypothesis:
![]() | (2) |
![]() | (3) |
is compared against the CSR point pattern at the 5% significance level, z0.05 = 1.65, as shown in Fig. 2(B)(ii).
Synthetic localizations were randomly generated around the true molecular positions and labeled accordingly, forming the ground-truth reference. We then applied mean-shift clustering to identify predicted localization clouds, assigning labels to each localization. The accuracy of this identification was quantified using the adjusted Rand index, which measures the similarity between ground-truth and predicted labels.24 A perfect identification yields a score of 1.0, so we interpret the adjusted Rand index as the localization cloud identification accuracy.
As shown in Fig. 2(B), identification accuracy decreases with increasing σcloud, and the rate of decline depends strongly on the underlying molecular distribution. Specifically, for clustered distributions, accurate identification is only possible at relatively low σcloud. We define the maximum identifiable cloud density σmaxcloud as the cloud density at which localization clouds can still be identified with at least 90% accuracy. We observed that σmaxcloud scales exponentially with the distribution score. In practice, this identification limit also depends on the localization precision and the bandwidth parameter used in clustering. In this study, we assume a typical localization precision of 8 nm and use an empirically optimized bandwidth parameter of 30 nm.14 The effect of localization precision and bandwidth parameter on the σmaxcloud for varying spatial distributions is explored in section S2.
Furthermore, in high-density biofunctionalized surfaces, not all molecules are guaranteed to interact with dye-labeled probes within the finite measurement duration, leading to undersampling and undercounting when using direct counting. To address this, we previously developed the Biomolecule Sampling Compensation (BiSC) analysis,14 a simulation-based method to compensate for sampling effects. In brief, we simulated binding events between probes and target molecules to explore the relationship between molecular density σmol and binding event density σevent for various probe kinetic and imaging parameters. From the resulting linear relation, the experimentally observed σevent can be used to estimate the molecular density
. Section S1.3 provides more details on the simulation procedure.
To assess the accuracy of this estimate, we applied a bootstrapping procedure: simulated datasets were resampled with replacement, and linear regression was repeated for each resampled set. Each regression model was used to estimate
for a given σevent, repeated 1000 times. The relative residuals were calculated as follows:
![]() | (4) |
is the mean of the estimated densities. The counting accuracy is defined as the standard deviation of the relative residuals.
As shown in Fig. 2(C), the counting accuracy improves with increasing σmol, due to improved event statistics. Accordingly, we define the lower limit of quantifiable molecular density σminmol and the corresponding σminevent as the threshold below which 90% accuracy cannot be achieved. By repeating this analysis across multiple combinations of probe kinetic constants and imaging conditions (see Table S5), we identified a scaling relationship between σminevent and (σmol)−2. Thus, we interpret σminevent as the minimum event density required to achieve molecular quantification of a given σmol with at least 90% accuracy.
As previously discussed, the spatial distribution of biomolecules can be described and quantified using nearest-neighbor distance-based statistics. The reliability of this quantification depends on several factors: the precision of the estimated molecular positions, the molecular sampling ratio sr (i.e., the fraction of molecules that interacted with the probe during the measurement), the true molecular density σmol, and the underlying true spatial distribution. Here, we investigate how the observed distribution score varies with these factors. The data were generated as described in Fig. 2(B)(i), where only a random subset of molecules was sampled according to sampling ratio sr:
![]() | (5) |
Fig. 3(B) shows three representative molecular distributions: clustered (true score = −18.6), random (true score = 0.3), and dispersed (true score = 18.5). For each case, the observed distribution score is plotted as a contour map over varying values of σmol and sr. For clustered and randomly distributed molecules, observed scores shift toward higher values (i.e., toward dispersion) as either σmol or sr increases. For dispersed molecules, scores shift toward randomness as sr decreases. Interpreting these contour maps is not straightforward. In practice, the true distribution is unknown, so the observed distribution score, calculated from the estimated molecular positions, is not an absolute value but an indicative one. Its meaning must be interpreted in reference to CSR, rather than to the ground truth. This raises an important question: how confidently can we interpret an observed distribution score (e.g., as clustered, random, or dispersed), based on the quantified values of σmol and sr?
Two conditions must be met for the interpretation to be valid. First, localization clouds must be identified with high accuracy to ensure precise estimation of the observed molecular positions. Based on the analysis in Fig. 2(B), we define a maximum sampling ratio smaxr as
![]() | (6) |
Note that smaxr may exceed 1 in low-density regimes, indicating potential oversampling. While the BiSC method is capable of handling both undersampling and oversampling, oversampling-related issues at low density are beyond the scope of this study. Therefore, smaxr is capped at 1. Second, the observed distribution score must pass the statistical test against CSR. For example, if the underlying molecular distribution is clustered, the observed score must be less than −z0.05 (i.e., −1.65) to be interpreted as such.
These two conditions help clarify the structure of the contour maps in Fig. 3(B). For randomly distributed molecules, the z0.05 contour line aligns with the boundary defined by smaxr, indicating that interpretability is governed primarily by the precision of estimated spatial positions of molecules. In contrast, for clustered and dispersed cases, both precision and statistical thresholding influence interpretability. Only a narrow region of σmol and sr values allows reliable identification of clustering, whereas a much larger region supports reliable identification of dispersion. Fig. 3(B)(ii) highlights the areas of interpretability, i.e., combinations of σmol and sr for which the observed score can be reliably interpreted, for each of the three cases. For random and dispersed distributions, these regions are extrapolated to higher values of σmol. In total, the analysis was performed across 11 true distribution scores ranging from −18 to 18. The corresponding evolution of the interpretability area is shown in the Fig. S3 and S4.
In this study, we systematically quantified the influence of these parameters using Monte Carlo simulations. Briefly, for a given σmol, we simulated binding events between probe molecules and individual targets to generate binding time traces, as illustrated in Fig. 4(A). This follows the same simulation framework as the BiSC analysis.14 From these time traces, we computed the PAINT outputs using the following definitions:
![]() | (7) |
![]() | (8) |
![]() | (9) |
![]() | ||
| Fig. 4 (A) Monte Carlo simulation of probe–target interactions in PAINT. Binding time traces are generated for each target molecule based on probe kinetics and imaging parameters. From these traces, three PAINT outputs are defined: σPSF, σcloud, and σevent. (B) Simulation data are used to train a neural network (NN) model. (i) The NN architecture includes two hidden layers with 200 and 100 nodes. The model achieves an accuracy of (99.3 ± 0.1)%. (ii) Validation against BiSC-based analysis on experimental datasets shows no significant difference in estimated molecular densities (p > 0.05, Welch's t-test). Molecular kinetic rates [kon (M−1 s−1), koff (s−1)] between the probe and target molecule are [106, 1] and [3.6 × 106, 1.9 × 10−2], for the ssDNA-based14 and protein-based system,26 respectively. (C) Main effect indices Si are computed from global sensitivity analysis using the NN model. | ||
Here, σPSF is defined as the mean number of PSFs observed over the acquisition duration t and area A. σcloud is the number of molecules with at least one binding event, normalized by A, and σevent is the total number of binding events per area. Note that the spatial distribution of molecules was not explicitly modeled, as the interpretability of distribution quantification can already be inferred from the molecular sampling ratio sr and σmol.
To assess the influence of input parameters on PAINT output, we performed a global sensitivity analysis using Sobol indices.30–32 These variance-based indices quantify the contribution of each input parameter to the total output variability. The first-order Sobol index Si, also denoted as the main effect index, captures the direct effect of a single parameter, while the total-order index St includes both the direct and all interaction effects. The difference St – Si reflects the strength of parameter interactions. While Sobol indices offer a global perspective, estimating them reliably requires a large number of model evaluations, typically on the order of N(k + 2), where N is the number of samples per parameter and k is the number of parameters, resulting in thousands of simulations.
To reduce this computational cost, we trained a feedforward neural network (NN) as a surrogate model using data from the Monte Carlo simulations.33 The network architecture consists of one input layer, two hidden layers, and one output layer. We generated 3500 datasets by simulating probe–target interactions under different parameter combinations, see Table 1. It is important to note that the model is not expected to provide reliable predictions outside the range of the training data. These were randomly split into 42% training, 28% validation, and 30% testing sets. The training data were used to optimize the model weights, while the validation data supported hyperparameter tuning and early stopping. Testing data provided an unbiased evaluation of model performance. The training of the model is shown in Fig. S1.
| Min | Max | # samples | |
|---|---|---|---|
| k on (M−1 s−1) | 103 | 107 | 5 |
| k off (s−1) | 10−4 | 100 | 5 |
| c img (M) | 10−12 | 10−9 | 4 |
| t (min) | 10 | 110 | 5 |
| σ mol (μm−2) | 0.1 | 2700 | 7 |
Since neural networks are inherently stochastic, due to randomness in initialization and optimization, we evaluated model consistency in two ways: (i) training the model 100 times using the same data and varying random seeds, and (ii) splitting the dataset 100 times and training with a fixed seed. Model accuracy was evaluated using the coefficient of determination R2 and the average accuracy was found to be (99.3 ± 0.1)%. To further validate the NN model, we used it to estimate molecular densities from two experimental datasets: one ssDNA-functionalized surface probed by ssDNA probes,14,34,35 and one protein-functionalized surface probed by Fab fragments.26 The ssDNA-functionalized surface was investigated using 25 pM ssDNA probes, while the protein-functionalized surface was studied using 1 nM Fab probes. The experimental procedures are detailed in section S5. Results were compared to BiSC-based estimates, and no significant difference was found based on Welch's t-test, confirming that the NN model reproduces the Monte Carlo results (Fig. 4(B)). However, it is acknowledged that validation using two datasets is insufficient to demonstrate the model's generalizability. Future work will therefore focus on extending model validation to additional systems involving fast-dissociating probes, such as aptamer-PAINT, peptide-PAINT, and nanobody-PAINT.
Fig. 4(C) presents the main effect indices Si of each input parameter on the PAINT outputs, as derived from sensitivity analysis on the NN model. Total-order indices St are provided in the Table S9. In general, the PAINT outputs were strongly dominated by main effects, indicating limited interaction between parameters. Among all inputs, the molecular association rate kon had the largest influence, followed by probe concentration cimg and molecular density σmol, across all outputs. For σPSF, however, koff contributed more than σmol, which is expected since longer binding durations (lower koff) increase the probability of PSF detection per measurement frame. Interestingly, acquisition duration t had the smallest effect (after koff) on both σcloud and σevent, even though longer acquisition times are intuitively expected to increase the number of detectable binding events. While the qualitative effects of experimental parameters on PAINT output are generally understood, this sensitivity analysis quantitatively ranks their relative importance and highlighted the dominant role of probe kinetics and concentration.
| Min | Max | # samples | |
|---|---|---|---|
| k on (M−1 s−1) | 103 | 107 | 25 |
| k off (s−1) | 10−4 | 100 | 25 |
| c img (M) | 10−12 | 10−9 | 100 |
| t (min) | 10 | 110 | 50 |
| σ mol (μm−2) | 0.1 | 2700 | 300 |
| True distribution score | −18 | 18 | 11 |
We first considered the effect of the probe concentration cimg on quantification performance for a DNA probe with reference kinetics kon = 106 M−1 s−1 and koff = 1 s−1 (Fig. 5(A)). Because acquisition duration t has limited influence on the PAINT output, we focused on the effect of cimg. Two scenarios were analyzed: (i) quantifying molecular density only, and (ii) quantifying both density and spatial distribution. For each value of cimg and for each true molecular distribution, we computed the range of σmol values that could be quantified with at least 90% accuracy. This range was normalized by the full simulated σmol range (≈2700 μm−2), yielding a maximum normalized value of 1, see section S4.1 for more details. This gives a map of quantifiable density range for a given probe.
When considering only density quantification, low values of cimg enable precise quantification across the entire simulated σmol range. However, when spatial distribution quantification is included as an additional criterion, only the trend for randomly distributed molecules resembles that of the density-only case. This is because the interpretability of distribution scores primarily depends on the accuracy with which individual localization clouds are identified. For dispersed distributions, a broad range of σmol can still be quantified at low cimg values, owing to the wide interpretability regions. However, the overall quantifiable range is slightly reduced, as low-density systems do not meet the minimum molecular sampling ratio required for statistically interpreting the distribution as dispersed. This threshold is governed by the statistical criterion that the distribution score must exceed z0.05. In contrast, for clustered distributions, only high values of cimg allowed even limited quantification, reflecting the inherently narrow area of interpretability for clustered spatial arrangements. Black squares in Fig. 5(A) indicate parameter combinations where no σmol values could be reliably quantified.
In practice, researchers are often interested not only in molecular density, but also in spatial distribution. The findings here highlight a critical limitation: spatial distributions that are inherently clustered cannot be effectively quantified using PAINT under high-density conditions. This raises an important consideration: what is the actual molecular feature of interest? For example, in a high-density surface functionalized via a multivalent linker such as neutravidin, clustering arises naturally due to multiple binding sites. In such cases, studying the spatial distribution of the linker (e.g., neutravidin) rather than the conjugated molecule may be more relevant. Since linkers are typically of lower density, their spatial distributions are more likely to fall within interpretable limits. Thus, while PAINT is limited in resolving high-density, clustered distributions, this limitation may not be critical if the system's design and biological context are appropriately considered. In cases where it is essential to quantify the spatial distribution of high-density, clustered molecules, the interpretability region must be expanded. This can be achieved by improving resolution (e.g., via RESI), and ensuring high molecular sampling ratios (see Fig. S5).
In the previous section, we emphasized the importance of probe kinetic constants on the PAINT output. Fig. 5(B) shows the parameter space over which different probes can yield high-accuracy quantification, along with the corresponding σmol ranges they can reliably probe. For molecular density quantification, we computed the mean normalized quantifiable σmol range (averaged over the number of true distributions considered) across the cimg values for each probe, and defined the probe score as the maximum of the means. When both density and spatial distribution quantification are required, the map is divided into three spatial regimes, namely clustered, random, and dispersed. For each regime, the mean normalized quantifiable density range is calculated across cimg, and the maximum value is taken as the probe score. The probe score thus represents the fraction of the full σmol range that can be quantified with at least 90% accuracy within the simulated cimg range, and reflects the objective of identifying probes that support reliable quantification over a broad range of true molecular densities σmol and spatial distributions, regardless of the probe concentration used. Fig. S7 illustrates the calculation of probe scores reported in this work.
When considering only density quantification, a wide range of probe kinetic constants, specifically, kon values from 103 to 107 M−1 s−1 and koff values from 10−2 to 1 s−1, support accurate quantification across broad σmol ranges. This flexibility is encouraging for the development of novel PAINT-compatible probes, as it suggests that a wide range of kinetic parameters can still yield reliable density estimates. When both density and spatial distribution quantification are considered, a similarly broad range of probe kinetics supports accurate and interpretable quantification for randomly and dispersed distributed systems. However, for dispersed systems, the quantifiable σmol range is slightly reduced because molecular sampling ratio thresholds required for statistical interpretability are not met for low-density systems.
In contrast, for clustered distributions, only a narrow range of probe kinetics enables limited quantification, again highlighting the intrinsic challenge of interpreting high-density clustered spatial arrangements. Improving PAINT resolution slightly expands the usable kinetic space and increases the quantifiable σmol range, as shown in Fig. S11. However, the range remains narrower than that for random or dispersed systems. The key takeaway from this finding is that clustered systems continue to pose a significant challenge for single-molecule quantification. Potential strategies to overcome this limitation include further improving PAINT resolution—through spectral multiplexing, temporal separation, or other super-resolution approaches—as well as developing new analytical methods to address inaccuracies in distribution quantification. It is important to recognize that increased resolution often comes at the expense of throughput and acquisition time. On the analytical side, one promising direction is machine-learning-based analysis that learns the relationship between PAINT precision, true molecular densities, sampling ratio, and distribution scores. Such a model could enable inverse estimation of true molecular distributions, even under suboptimal resolution.
Another important observation is that probes with similar probe scores may operate in different cimg regimes, depending on their kinetic parameters, as shown in Fig. 5(C). This variability is further illustrated in Fig. S8–S10. For probes with lower kon, the quantifiable density range is constrained by two major factors: the σminevent threshold defined in the BiSC analysis, and the minimum required sampling ratio sr = σcloud/σmol for interpreting spatial distributions. The σminevent threshold accounts for the statistical requirements needed to overcome molecular undersampling and ensure accurate density estimates, while the sr threshold reflects the statistical minimum necessary to confidently classify the spatial distribution as non-random, i.e., distribution score > z0.05 or < z0.05.
For probes with lower kon, the σminevent threshold forces the viable cimg regime to shift toward higher concentrations, as sufficient binding events cannot be generated at lower probe concentrations. This results in regions in the cimg space where no densities can be quantified, as highlighted by black squares in the quantification maps. In parallel, the sr constraint further narrows the viable cimg range, particularly in non-random systems. While dispersed systems generally exhibit broader interpretability regions, mildly dispersed cases fail to meet the sr threshold in mid-cimg regimes, leaving these areas unquantifiable. For clustered systems, where the interpretability region is inherently narrow, quantifiable densities are confined to very low values and only become accessible at the highest cimg values.
Overall, despite differences in the cimg regimes where quantification is feasible, the resulting probe scores for these probes remain similar. This underscores the importance of tailoring imaging conditions to the specific kinetic properties of the probe to achieve optimal quantification performance. Moreover, these findings offer valuable insight into the range of probe kinetic constants that are compatible with high-accuracy molecular quantification in PAINT. This provides practical guidance for the rational design of next-generation, non-DNA-based PAINT probes targeting diverse molecular systems.
Leveraging the trained NN model as a surrogate, we explored the parameter space across a wide range of experimental conditions to identify optimal regimes that enable accurate and interpretable molecular quantification. Our results underscore that while a broad range of kinetic and concentration parameters can support high-accuracy density quantification, the reliable interpretation of spatial distributions—particularly in high-density, clustered molecular systems—remains a major challenge in single-molecule quantification. We also emphasize that interpretability depends also on a priori knowledge of the molecular system of study, which can help redirect the focus of analysis toward more tractable molecular targets, such as linker molecules. When high-density clustered distributions must be characterized, improvements in PAINT resolution or advanced analytical corrections become essential. However, it is important to emphasize that improved resolution often comes at the cost of reduced throughput and longer acquisition times.
Overall, the described in silico approach provides a quantitative foundation for selecting experimental conditions that ensure accurate molecular quantification in PAINT experiments. This framework is especially relevant for biological systems with nanoscale molecular organization, including nuclear pores, focal adhesions, and immune synapses, where accurate spatial quantification is critical for understanding molecular function. Beyond optimizing imaging parameters, this framework offers practical design guidelines for developing next-generation PAINT-compatible imaging probes, particularly for non-DNA targets. Linkage and labeling errors—common when tagging molecular targets with DNA-functionalized linkers—pose significant challenges to accurate distribution quantification. Notably, our results demonstrate that even in the absence of such errors, spatial distribution quantification for clustered systems remains inherently constrained. We therefore advocate for the development of novel, non-DNA-based PAINT probes capable of transient, direct binding to molecular targets. The analysis presented here offers actionable insights into the kinetic design requirements for such probes. By clarifying the interplay between experimental variables and quantification limits, this work contributes to expanding the applicability and reliability of PAINT for molecular quantification across diverse biological and synthetic surfaces.
| This journal is © The Royal Society of Chemistry 2025 |