Open Access Article
Casey Erin
Adam
ab,
Alba Rosa
Piacenti
a,
Yuanmin
Zhang
a,
Sarah L.
Waters
b and
Sonia
Contera
*a
aDepartment of Physics, University of Oxford, Parks Road, Oxford, OX1 3PU, UK. E-mail: sonia.antoranzcontera@physics.ox.ac.uk
bDepartment of Applied Mathematics, University of Oxford, Andrew Wiles Building, Radcliffe Observatory Quarter (550), Woodstock Road, Oxford, OX2 6GG, UK
First published on 30th July 2025
The mechanical properties of the polymeric substrate or matrix where a cell grows affect cell behavior. Most studies have focused on relating elastic properties of polymeric substrates, which are time-independent, to cell behaviors. However, polymeric substrates and biological systems exhibit a time-dependent, often viscoelastic, mechanical response. While less is known about how time responses dictate cell behavior, cells are likely sensitive to substrate time responses rather than elasticity alone. However, testing this hypothesis is complex due to the lack of nanoscale tools. To overcome this limitation, photothermal actuation-atomic force microscopy nanoscale dynamic mechanical analysis (PT-AFM nDMA), a novel AFM technique that measures sample viscoelasticity over a broad and continuous frequency range, was applied to measure the viscoelastic properties of cell culture substrates made of poly(2-hydroxyethyl methacrylate) (poly(HEMA)) and collagen I (pureCol) in liquid at frequencies ranging continuously from 0.1 Hz–5000 Hz. PT-AFM nDMA to date has not been performed in liquid, but successfully and accurately characterized substrate viscoelasticity and synergized with measurements obtained using a more established AFM technique, bimodal imaging. The results of this study demonstrate that PT-AFM nDMA can be performed in liquid environments, especially relevant to biological samples. Additionally, comparing PT-AFM nDMA measurements of the poly(HEMA) and pureCol substrates in this study to cell behaviors described in the scientific literature on similar substrates suggests that longer substrate time responses at low measurement frequencies promote cell attachment, proliferation, and migration, while shorter substrate time responses promote ECM remodeling and differentiation.
It is already established that E, η, and τ of a substrate influence cell behaviors. For example, substrate E alters proliferation and survival,10–14 differentiation,11,12,15–26 migration,27–35 morphology,12,36–39 cytoskeletal properties and adhesion,23,40–46 plasma membrane structure,30,47,48 cell signaling and gene expression,14,24,30,34,35,38,49–56 and other cell activities.6,26,34,35,57–59 Substrate η, as well as that of the surrounding fluid (hydration shells or the bulk fluid), is as important as E in dictating cell behaviors.60–73 Since τ dictates propagation and attenuation of forces,7,9 it is reasonable to hypothesize that certain τ promote certain cell behaviors. Experiments that focus on the effect of substrate τ suggest that shorter τ promote ECM deposition and remodeling, as well as differentiation of cells within the substrate,61 while longer τ seem to exhibit the opposite effects.60 However, further investigation is required because the majority of studies quantify only substrate E or stiffness. Thus, the relation between substrate τ and cell behaviors is less understood than that of substrate E and cell behaviors.
Atomic force microscopy (AFM) is a particularly useful tool to measure nanoscale mechanical properties because AFM can probe a sample with angstrom resolution, can measure changes in forces as small as 10s of pN, can be performed in liquid, does not require sample processing such as fixation, can be performed on living samples, and has higher resolution and more localized control than other techniques such as optical and magnetic tweezers.74,75 Several recent AFM advances have increased the ease of quantifying sample viscoelasticity, thereby enhancing the possibility of further studying the relationship between cell behavior and substrate mechanics. Such techniques include bimodal imaging, which measures nanoscale viscoelasticity at discrete frequencies, typically in the kHz range,74,76–87 and has already been used to study a variety of biological samples.82,83 The most common form of bimodal AFM is amplitude modulation-frequency modulation AFM (AM-FM AFM).76,77,83 However, viscoelasticity is time dependent, meaning the frequency at which a sample is deformed determines the viscoelastic response, and it is therefore important to measure sample viscoelasticity over a range of frequencies.7,9 Such nanoscale rheology can be performed with AFM techniques such as piezoelectric88–105 or photothermal106,107 actuation AFM nanoscale dynamic mechanical analysis (PE-AFM nDMA and PT-AFM nDMA, respectively), which measure sample viscoelasticity over a continuous frequency range that spans several orders of magnitude.106,107 PE-AFM nDMA is an established technique where either the cantilever holder or the sample are oscillated via PE actuation.88–105 However, PE actuation introduces spurious resonance effects which are more pronounced in liquid and limit PE-AFM nDMA capabilities,88,89,89–93,97,98,107–111 even when compensations for such resonances are performed.88,89,89–93,97,98,111 Unlike PE-AFM nDMA, PT-AFM nDMA excites only the cantilever, thereby eliminating extra resonances due to sample or holder oscillation and increasing the range of frequencies at which sample mechanics can be measured.107 However, PT-AFM nDMA is a novel technique that to date has only been performed on samples in air.107 Therefore, investigation of whether PT-AFM nDMA can be performed in liquid without resonance and other liquid effects is required.
The purpose of experiments in this article is twofold. First, since PT-AFM nDMA is a novel technique106,107 that has yet to be performed in liquid environments, this article provides a detailed analysis (sections S7–S11) of how to perform PT-AFM nDMA in liquid to ensure that features such as damping due to fluid effects do not interfere with PT-AFM nDMA measurements, and to demonstrate that PT-AFM nDMA results are robust, even in liquid. Second, AM-FM AFM and PT-AFM nDMA were combined in order to quantify the nanoscale viscoelasticity, in particular τ, of widely used cell culture substrates in liquid, then correlate τ of each substrate with known cell behaviors on similar substrates. Six different substrates: three consisting of poly(2-hydroxyethyl methacrylate), poly(HEMA)112,113 at different concentrations, and three collagen I substrates with varying amounts of crosslinking114,115 were measured. These substrates were selected because cell behaviors on each substrate are well characterized in the literature,13,22,27,114,114–126 both substrates are widely used in industry and research, and the macroscale mechanical properties of these substrates are well studied.65–71,113,127–135 Both poly(HEMA)127,128,129,130,131 and collagen I65,66–71,132–135 substrates are viscoelastic.
Poly(HEMA) substrates strongly influence cell behaviors,112 and are used in biomedical applications such as cell culture, contact lenses, fillings, histology, immobilization of cells and drugs, and implants.113 The thickness of poly(HEMA) films modulates cell spreading and activities.112,113 Higher concentrations of poly(HEMA) within a substrate hinder cell attachment, spreading, and DNA synthesis.112,113 Substrates with high concentrations of poly(HEMA) have also been shown to decrease DNA synthesis in bovine aortic endothelial cells,112 alter cytoskeleton (actin) dynamics in neutrophils,136 alter leukocyte locomotion, force malignant melanoma cells to assume a round morphology and form polykaryons (multiple nuclei within a single cell), and decrease adrenal tumor cell synthesis of steroids.113 Additionally, the viscoelastic properties of neutrophils are altered on poly(HEMA), compared to glass substrates.136
Collagen I is a widely used cell culture substrate114,115 because collagen is the most prevalent protein in the human body, and collagen I is the most common form of collagen.115–119 The mechanical properties of collagen I substrates regulate cell proliferation13 and survival,115 affect ECM deposition and remodeling,120 regulate stem cell differentiation,22 and regulate cell migration.27 One commonly used collagen I substrate is known as pureCol™.114 PureCol is a ready-made solution of purified collagen I isolated from bovine skin and suspended in cell culture medium.137 PureCol substrates affect cell morphology, proliferation, and viability.114 Additionally, the elasticity of pureCol substrates is known to influence cell migration.121 An additional benefit from the use of pureCol and similar collagen I substrates is that the mechanical properties of the substrates are tuneable via the use of crosslinking agents such as glutaraldehyde (GA).122–126 Therefore, collagen substrates are convenient for studying how varying the mechanical properties of a substrate alter cell behaviors and mechanics.
All poly(HEMA) and pureCol substrates were measured in live cell imaging solution (Sigma-Aldrich A14291DJ), which mimics physiological salt concentrations. Live cell imaging solution consists of 140 mM NaCl, 2.5 mM KCl, 1.8 mM CaCl2, 1.0 mM MgCl2, and 20 mM (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) (HEPES) at pH 7.4 and with an osmolarity of 300 mOsm.138 The PDMS substrate was measured in milliQ water, as detailed in section S10. Table 1 summarizes the expected outcomes of PT-AFM nDMA measurements for pureCol and poly(HEMA) substrates. Additional details describing how these expected results were obtained can be found in section S12.
| Substrate | tan δ |
E′ | E′′ |
|---|---|---|---|
| Poly(HEMA) substrates127,128 | Should be on the order of 10−1 at lower f, but increase to 100 near f = 100 Hz | Should be on the order of 103–105 Pa and have no abrupt changes in slope for f < 100 Hz | Should be on the order of 103–105 Pa and have no abrupt changes in slope for f < 100 Hz |
| PureCol substrates67,122,132–135,139–142 | Should be on the order of 10−2–10−1 and have no abrupt changes in slope for f < 600 Hz | Should be on the order of 102–103 Pa, but could be as high as 108 Pa, and have no abrupt changes in slope for f < 600 Hz | Should be on the order of 101–102 Pa, but could be as high as 107 Pa, and have no abrupt changes in slope for f < 600 Hz |
| GA effects on pureCol122,140–142 | Should be 1.2–4× higher for 30 min GA crosslinking than 2 h or 24 h, and should be similar for the 2 h and 24 h GA samples | The 2 h and 24 h GA samples should be more similar to each other than the 30 min GA sample. E′ will either increase or decrease with increased GA crosslinking, but direction is unclear due to conflicting literature reports | Should follow similar trends to E′ |
Once poly(HEMA) solutions were deposited onto coverslips, the sample was left to dry at room temperature for 48 hours to ensure that all the ethanol had evaporated. After drying for 48 hours, coverslips with dry poly(HEMA) substrates were secured to a magnetic disk, which holds the sample in place during AFM measurements, using double-sided foam (RS Components 554-844), and transferred to an Oxford Instruments Asylum Research Cypher ES AFM. In order to simulate physiological conditions, 200–400 μL of live cell imaging solution (Sigma-Aldrich A14291DJ) were then pipetted onto the sample. Measurements were obtained at least 30 minutes after live cell imaging solution was added in order to allow the poly(HEMA) substrates to fully swell.112
After pureCol was added to the custom chamber, the chamber was incubated at 37 °C for 90 minutes to allow the collagen to polymerize. The resulting substrate is shown in Fig. S11C. While the collagen polymerized, a 50% glutaraldehyde (GA) solution in water (Sigma-Aldrich 340855) was diluted in Dulbecco's phosphate buffered saline (DPBS, Sigma-Aldrich D5796) to a final concentration of 1% GA in DPBS. Once polymerization was complete, 400 μL of the 1% GA in DPBS were deposited on top of the pureCol (Fig. S11D). Samples were then left to crosslink in GA at room temperature for: 30 minutes, 2 hours, or 24 hours. GA crosslinking durations were based on those used in the literature to alter the number of crosslinks between the three substrates.123–125 This particular crosslinking procedure was adopted for reasons detailed in results section 3.1. After GA crosslinking was complete, samples were washed three times via the following procedure. First, any liquid was pipetted off the sample. Next, 400 μL of DPBS were pipetted onto the samples and left to sit for five minutes. This procedure was repeated three times. After the final wash, the DPBS was removed, and replaced with 400 μL of live cell imaging solution (Sigma-Aldrich A14291DJ). A completed sample is shown in Fig. S11E, and was roughly 0.3 cm thick. The sample was then transferred to an Oxford Instruments Asylum Research Cypher ES AFM.
δ = E′′/E′, measured by both techniques).76,83,107,143 All three properties are functions of sample E and η, and by extension τ, since τ = η/E.7,144 The exact formula relating E and η to E′, E′′, and tan
δ depends on the type of viscoelasticity exhibited by a sample (details and formulas are provided in section S1),7,144 and can be determined from dynamic measurements.87,144
AM-FM AFM measures sample tan
δ and E′ at one specific frequency, and tan
δ corresponds to a different frequency than E′.76,77,83 In AM-FM AFM, the surface of a sample is intermittently tapped via a tip connected to a cantilever that is oscillated at two of the cantilever's eigenmodes.76,77,83 Cantilever properties at each mode include: frequency fc, stiffness kc, and the resonance peak at fc has quality factor Qc.76,77,83 The cantilever's vibration at each eigenmode has amplitude Ar far from the sample, amplitude A on the sample, and phase ϕ.76,77,83 These properties of the cantilever (kc, Qc, fc) and bimodal oscillation (Ar, A, ϕ) at each eigenmode (subscript 1 for the lower frequency mode, 2 for the higher frequency mode) are used to calculate sample tan
δ at f1viaeqn (1)
84,85 and E′ at f2viaeqn (2).76,86 Additional details on how these formulas are derived and the operating principles of AM-FM AFM can be found in section S2.
![]() | (1) |
![]() | (2) |
Here,
is the contact modulus which converts to sample E′.76,86 Note that, to obtain eqn (2), the Hertz contact model is used to describe the tip/sample interaction.76,86 The Hertz model assumes an elastic, nonadhesive interaction between a spherical indenter and sample.9,145 Therefore, AM-FM AFM quantification of E′ can be incorrect if the tip/sample contact is non-Hertzian.76,77,87,107
The measured E′ and tan
δ from all pixels of a single AM-FM AFM image can be used to determine the viscoelastic model which best describes sample behavior.87,146 One model of viscoelasticity that is widely applicable to biological systems is the General Maxwell Model (GMM), also called the Wiechert model (eqn (S4) and (S14)–(S16)).7 Details of the GMM, as well as special cases of the GMM called the standard linear solid (SLS, eqn (S1) and (S11)–(S13)), Kelvin–Voigt model (KV, eqn (S2) and (S8)–(S10)), and Maxwell model (MW, eqn (S3) and (S5)–(S7)) are provided in section S1. It is possible to use AM-FM AFM measurements to determine whether the GMM or special cases of the GMM describe a sample by plotting y = tan
δ−1 against x = (E′
tan
δ)−1 and fitting a line with slope m and y-intercept b to the data.87 If the fit has a low root mean square error (RMSE), then the GMM, SLS, KV, or MW model describes sample behavior.87 If both m > 0 and b > 0, then the GMM or SLS describes the sample.87 The GMM applies if the points from the fit appear curved, even though still well described by a line, while the SLS applies if the points appear linear.87 If m > 0 and b = 0, then the KV model applies.87 If m = 0 and b > 0, then the MW model applies.87 This test can accurately determine the viscoelastic model to describe a sample even if the measured E′ is incorrect due to applying the Hertz model to a non-Hertzian tip/sample contact.87
While AM-FM AFM measures sample tan
δ and E′ at different, discrete frequencies,76,84–86 PT-AFM nDMA measures sample E′, E′′, and tan
δ over a continuous range of frequencies.107 In PT-AFM nDMA, the sample is indented and allowed to fully relax, then the cantilever is oscillated via a chirped frequency signal, then withdrawn.107 The same chirp measurement is repeated out of contact with the sample and acts as a reference measurement.107 Cantilever A and ϕ at each measurement frequency are then compared between the sample (s) and reference (r) measurements to obtain tan
δ and the storage and loss stiffness (k′ and k′′, respectively) of the sample viaeqn (3)–(5).90,104,107
![]() | (3) |
![]() | (4) |
![]() | (5) |
Finally, k′ and k′′ are converted to E′ and E′′ by applying a contact model.107 Additional details of PT-AFM nDMA operating principles can be found in section S5.
AM-FM AFM uses the Hertz model to calculate sample E′.76,86 Therefore, to keep the contact model consistent between measurement techniques in this article, the Hertz model was also applied to obtain PT-AFM nDMA E′ and E′′ (see eqn (S34) and (S35)). Other contact models, while likely more applicable, are not investigated in this study. The use of the Hertz model for AM-FM AFM76,86 necessitates use of the Hertz model for PT-AFM nDMA to ensure that results from each technique can be compared. While doing so will affect E′ and E′′, the same is not true for tan
δ.87,107 Regardless of measurement technique, contact geometry cancels in tan
δ, rendering tan
δ independent of contact mechanics.87,107
PureCol substrates were measured by two different cantilevers in order to assess how cantilever selection affected PT-AFM nDMA measurements. First, each cantilever was loaded into a separate holder, and the spring constant of both cantilevers was calibrated in air via the Oxford Instruments Asylum Research GetReal™ calibration method.143,147,148 Next, the hydrated sample then the holder containing the RC800PSA were loaded into the Cypher, the RC800PSA's inverse optical lever sensitivity (InvOLS) was calibrated far from the sample, then AM-FM AFM and PT-AFM nDMA were performed using the RC800PSA. The cantilever holder containing the RC800PSA was then swapped for that containing the AC240TSA, AC240TSA InvOLS was calibrated far from the sample, then measurements were repeated with the AC240TSA. Thereby, the effect of cantilever selection was analyzed on measurements of the same substrate as close to the same location on the sample as possible. Poly(HEMA) substrates were only measured with AC240TSA cantilevers because RC800PSA cantilevers were too soft to accurately quantify poly(HEMA) sample properties.
000 Hz during a PT-AFM nDMA dwell of 40 seconds. For pureCol, frequencies ranged from 0.1–10 Hz during a PT-AFM nDMA dwell of three minutes, and from 1–5000 Hz during a PT-AFM nDMA dwell of 40 seconds. PT-AFM nDMA is an off resonance technique (see section S5.1).107 Therefore, PT-AFM nDMA was not performed at frequencies higher than 5000 Hz for RC800PSA measurements and 10
000 Hz for AC240TSA measurements in order to avoid introducing error caused by cantilever resonance effects. The drive amplitude of each chirp was 0.25 V, resulting in a maximum chirp amplitude of roughly 40 nm (at lower measurement frequencies) and a minimum chirp amplitude of roughly 2.5 nm (at higher measurement frequencies). Example plots of amplitude as a function of measurement frequency are shown in Fig. S9A and previously published.106,107 Samples were indented to a force trigger point (see sections S4 and S8 for an explanation of indentation and trigger points) that resulted in a sample indentation between 100 nm and 600 nm, around which the PT-AFM nDMA measurement oscillated. Indentation depth was tailored for each sample as described in section S8 to ensure measurements were performed in the linear viscoelastic regime of the sample, where measurement values are independent of sample indentation.9,107 Example indentations without the PT-AFM nDMA oscillation are shown in Fig. 1A, C and Fig. S10. Indentation approach and withdraw velocity was 1 μm s−1, with an approach time of 5–15 s to allow full sample relaxation before performing the PT-AFM nDMA chirp.
![]() | ||
| Fig. 1 Example pureCol substrate indentation curves. During indentations, an AFM tip is pressed into a sample (red curve) then retracted (blue curve).74 The force, F, experienced by the cantilever and sample indentation, d, are tracked throughout.74 More details on indentations can be found in section S4. A typical F vs. d curve obtained with an AC240TSA cantilever on pureCol substrates that could be measured with AM-FM AFM and PT-AFM nDMA is shown in (A). Green arrows indicate the force curve region where the bulk pureCol is indented. Bumps in the approach curve (black brackets), indicate that the tip passed through a surface layer of material roughly 150 nm thick, likely a polymer brush, before reaching the bulk. (B) shows an AC240TSA F vs. d curve of a pureCol substrate with a surface layer thicker than 1 μm, which prevented AM-FM AFM or PT-AFM nDMA from accurately quantifying sample viscoelasticity. (C) shows a representative F vs. d curve obtained with an RC800PSA cantilever on the same substrate as (A), indicating that the RC800PSA was less sensitive to the substrate's surface layer than the AC240TSA. (D) shows an RC800PSA F vs. d curve of a substrate with a thick surface layer, similar to (B). | ||
δ and E′ of the substrates by applying eqn (1) and (2) to AM-FM AFM data, then used these values to determine if the GMM or special cases of the GMM (model details can be found in section S1) applied to the substrate.87,146 The custom script also calculated the mean and standard deviation of substrate feature height, E′, and tan
δ by fitting a Gaussian to the distribution of values within a particular image or within the sample as a whole, as detailed in section S3. This method of calculating the mean and standard deviation was used in order to minimize the effects of bimodal or multimodal distributions of the data, shown in section 3.2.1. Comparison p-values were calculated from pairwise t-tests between the relevant samples.
Another custom script written in MATLAB R2019b 9.7.0.1261785 was used to analyze PT-AFM nDMA data. This script loaded sample and reference measurements, then applied eqn (3)–(5) in order to calculate k′ and k′′, as well as tan
δ of the sample. Next, the Hertz contact model9,76,86 was applied to calculate E′ and E′′ from k′ and k′′ via eqn (S34) and (S35). The contact point, where the tip first touches the sample, was manually identified for application of the Hertz contact model. While other contact models likely better describe the tip/sample interaction during PT-AFM nDMA measurements, the Hertz model was applied to PT-AFM nDMA measurements in order to keep the contact model consistent between AM-FM AFM, which solely uses the Hertz model,76,77,86 and PT-AFM nDMA. In order to reduce measurement artifacts arising from factors such as friction, which affected some of the lower frequency measurements, or Gibbs phenomena, which affected the higher frequencies of each chirp regime, the ends of each PT-AFM nDMA measurement were trimmed, then measurements were smoothed using the Savitzky–Golay filter, as detailed in section S6, and shown in Fig. S3.
δ of the substrates over a range of frequencies. Measurements were then averaged for each substrate, used to calculate substrate time responses, and compared across substrates (section 3.4).
Initial attempts to crosslink pureCol substrates were performed by varying the concentration of GA in the crosslinking solution to which the substrate was subjected for 30 min. GA concentrations of 0.01%, 1%, 2%, and 4% were used, based on previous literature.124,126 Substrates crosslinked with 0.01% GA behaved in a similar manner to pureCol that was not crosslinked, and therefore could not be measured. Substrates crosslinked with 2% or 4% GA possessed a layer of loose surface material thicker than one μm (shown in Fig. 1B and D). It was not possible to perform AM-FM AFM on these substrates because the thick surface layer prevented a repulsive tip/sample interaction, which is required for AM-FM AFM measurements.85 While it was possible to indent through the surface layer to the bulk pureCol substrate (indentation experiments are described in section S4), the thick surface layer caused spurious cantilever deflection during PT-AFM nDMA measurements, preventing accurate PT-AFM nDMA quantification of sample properties. These layers and layer effects were reproducible, and occurred in two to three samples for each (2% and 4%) GA concentration. Substrates crosslinked with 1% GA did not exhibit thick surface layers (Fig. 1A and C). Therefore, subsequent attempts to crosslink pureCol substrates were performed by varying the time to which the substrate was exposed to 1% GA, with longer exposure times resulting in more crosslinks.123–125 PureCol samples exposed to GA for 4 hours also exhibited thick surface layers. However, samples crosslinked for 30 minutes, 2 hours, and 24 hours did not have surface layers (Fig. 1C), or surface layer thickness was small enough not to impede measurements (Fig. 1A).
The surface layer on pureCol substrates is most likely a polymer brush.149 Such brushes can form as the result of loose polymer ends protruding from the surface of the substrate, and can range from tens or hundreds of nanometers150,151 to several microns in thickness.149,152 Additionally, loose ends of collagen fibrils in tendons can behave as polymer brushes.153 These results demonstrate that, if a sample contains thick polymer brushes or other surface effects, the reference measurement for PT-AFM nDMA may be unable to account for such effects, and PT-AFM nDMA will therefore be unable to accurately measure sample properties. Additionally, these effects may be more pronounced in liquid, where substrates swell and loose polymer ends floating at the substrate surface are freer to move7 and interact with the tip and cantilever. Such surface effects are investigated in greater detail in section S10.
AC240TSA cantilevers (Fig. 1A) were more sensitive to the pureCol surface layer than RC800PSA cantilevers on the same substrate (Fig. 1C). The higher stiffness of AC240TSA cantilevers means that less energy from tip/sample interactions would be dissipated by the cantilever, thereby rendering AC240TSA cantilevers more sensitive to vibrations caused by interactions with the substrate's surface layer. Therefore, in agreement with previous literature,107 cantilever selection will likely affect PT-AFM nDMA measurements. Additional analysis of cantilever selection on PT-AFM nDMA measurements in liquid is provided in section S9.
δ (section 3.2.1), quantify sample properties at AM-FM AFM measurement frequencies (section 3.2.2), and determine the type of viscoelasticity exhibited by each substrate (section 3.2.3). Details on the cantilever, scan dimensions, and number of pixels analyzed for each AM-FM AFM image in this article are provided in Table S1. Sample indentations in AM-FM AFM are only a few nm deep,77 constituting roughly 0.0001% of pureCol sample thickness and roughly 0.01%, 0.1%, and 1% of the 11.4, 1.14, and 0.114 mg poly(HEMA) per cm2 substrate thickness, respectively.
δ, indicating local variation in sample mechanics at the nanoscale. Typically, these distributions were best described with a two term Gaussian model (details in section S3 and eqn (S27)). Since only a single substrate was imaged at a given time, different peaks in the two term Gaussian fits correspond to various structures or orientations of the substrate's constituent polymers.
As shown in Fig. 2, bimodal distributions of the AM-FM AFM data prevented accurate calculation of sample means and standard deviations when the standard formulas were used. To overcome this issue, as described in section S3, the mean and standard deviation of substrate AM-FM AFM data was calculated by fitting Gaussians to the data distributions. For individual image statistics, the distribution used for the fit comprised of pixel values from a particular AM-FM AFM image. For overall statistics, the distribution comprised of pixel values from all AM-FM AFM images. The mean and standard deviation calculated from the Gaussian fit represent the most prominent peak of the distribution, corresponding to the most prevalent polymer structure (for example, polymer orientation, tangling, or other topographies) in the substrate. As shown in Fig. 2, this Gaussian fit method of calculating sample statistics matches the values from the standard formulas if the data distribution is unimodal.
δ (magenta arrows in Fig. 3B and C).
Representative AM-FM AFM images of pureCol substrates collected with an AC240TSA are shown in Fig. 3D–F. Fig. 7B–D and Fig. S12 show representative AM-FM AFM images collected with an RC800PSA. PureCol substrate topography and viscoelasticity varied with GA concentration. Additionally, pureCol substrate topography differed when different cantilevers with different sensitivities to tip/pureCol interactions (already demonstrated in Fig. 1A and C) were used. For example, interactions between sample hydration shells and an AFM tip can vary with cantilever selection, and affect the tip's ability to image a sample.154,155
To quantify the differences in AM-FM AFM images between substrates, Fig. 4 shows the mean height (surface topography, not substrate thickness), E′, and tan
δ of each substrate. As shown in Fig. 4A, topography of the 11.4 and 1.14 mg poly(HEMA) per cm2 substrates was the same (p = 0.99). The mean and standard deviation in film height of the 0.114 mg poly(HEMA) per cm2 substrates were larger than the other poly(HEMA) substrates, meaning the sample exhibited more varied topography. This observation agrees with the fact that large poly(HEMA) clumps surrounded by glass were observed on the 0.114 mg poly(HEMA) per cm2 substrates, but not substrates with higher poly(HEMA) concentrations (Fig. 3A). Poly(HEMA) films are known to uniformly coat the underlying substrate, but decrease in thickness with decreasing poly(HEMA) concentration,112 until the polymer is sparse enough that clumps form and the film is no longer uniform (Fig. 3A). The identical topography of the 11.4 mg per cm2 and 1.14 mg per cm2 substrates (Fig. 4A) agrees with the literature observations112 that poly(HEMA) films are uniform unless the polymer is too sparse.
As shown in Fig. 4C, E′ was highest for the 1.14 mg poly(HEMA) per cm2 substrates (p = 0.02 vs. the 11.4 mg cm−2 sample and p = 0.05 vs. the 0.114 mg cm−2 sample). Since the main difference between each substrate is the thickness of the poly(HEMA) film or clumps112 on the coverslip, not the poly(HEMA) itself, these results show that film thickness affects E′. The fact that E′ increased as the poly(HEMA) film thinned suggests that coverslip glass underlying the poly(HEMA) influenced the measurements, even though the tip did not indent through to the glass. This influence, where an underlying hard substrate alters the tip/sample interaction on thin soft substrates, is referred to as a bottom effect.156 In such cases, a bottom effect correction should be applied in the contact model.156 Reliance on the Hertz contact model in AM-FM AFM neglects this correction,156 likely leading to incorrectly high values of E′ for the 1.14 mg per cm2 substrate, and possibly other poly(HEMA) concentrations. Additionally, the fact that E′ of the 0.114 mg poly(HEMA) per cm2 substrate was closer to that of the 11.4 mg per cm2 substrate supports the notion that bottom effects are present in poly(HEMA) measurements. Poly(HEMA) clumping in the 1.14 mg poly(HEMA) per cm2 substrate could have been substantial enough to reduce bottom effects. Furthermore, as shown in Fig. 4E, tan
δ was not significantly different between the different poly(HEMA) substrates (p > 0.2 for all comparisons). The fact that tan
δ, but not E′, is independent of contact mechanics, including bottom effects,87,107 lends support to the notion that a bottom effect was present in poly(HEMA) E′ values. However, expansion of AM-FM AFM's calculation of E′ to include a bottom effect correction is beyond the scope of this work. Regardless, cells on substrates with low poly(HEMA) concentrations might be able to probe through the poly(HEMA) to the underlying material. The fact that tan
δ was not significantly different between the different poly(HEMA) substrates, combined with the likelihood that alterations to E′ of poly(HEMA) substrates were due to bottom effects rather than differences in poly(HEMA) viscoelasticity, suggests that poly(HEMA) substrates modulate cell activities by how much cells can probe the underlying substrate through the poly(HEMA) film.
The properties of pureCol substrates varied more than poly(HEMA) substrates. Feature height on the surface of pureCol substrates (Fig. 4B) increased with increasing GA crosslinking duration (p < 0.04 for all comparisons). This trend agrees with previous observations that GA crosslinking increases the diameter of collagen fibers.122 The increase is likely due to rearrangement of collagen fibrils by crosslinking. For example, consider one immobile polymer and one free polymer. If a single crosslink forms between the immobile polymer and the free polymer, the ends of the free polymer will fluctuate around the crosslink until coming into contact with other locations on the immobile polymer with which another crosslink can form.7 If a subsequent crosslink forms, motion of the free polymer is even more restricted along the dimensions of the immobile polymer.7 Eventually, as crosslinks are added, the free polymer will align with the immobile polymer.7 In other words, polymers are bundled together as crosslinking occurs. With longer exposure to GA, more crosslinks form,124 resulting in more polymer bundling, thicker fibers, and thus the observed increase in feature height and fiber diameter with crosslinking duration.
Fig. 4D shows that E′ of pureCol substrates increased with crosslinking duration (p < 0.01 for both cantilevers), and the increased crosslink density with longer GA exposure. E′ of substrates crosslinked for 30 minutes or 24 hours varied between AM-FM AFM images, as indicated by magenta arrows in Fig. 4D. Note that the representative E′ maps in Fig. 3E correspond to the lower E′ values (lower magenta arrows in Fig. 4D). This heterogeneity suggests that the amount of GA crosslinking varied locally at the nanoscale. Since the substrates were roughly 0.3 cm thick (Fig. S11), the variation in E′ is not due to a bottom effect, but due to local variations in pureCol configuration. As shown by Fig. 4F, tan
δ was not significantly different between samples crosslinked for 2 and 24 hours (p = 0.64 for RC800PSA cantilevers and p = 0.10 for AC240TSA cantilevers). Substrate tan
δ was higher for samples crosslinked for 30 minutes (p ≤ 0.01 for both comparisons with both cantilevers). Since tan
δ = E′′/E′, this observation demonstrates that crosslinks affect energy storage (E′) and dissipation (E′′) in collagen substrates differently.
δE′)−1 is plotted against (E′)−1 for all pixels in a single AM-FM AFM image. If the points are well described by a line, one of the standard models of linear viscoelasticity: the GMM, SLS, KV, or MW model (model details can be found in section S1), describes the sample's response.87 If the sample behaves as a GMM, SLS, KV, or MW material, other types of time dependent mechanical responses such as poroelasticity can be neglected, and the sample considered viscoelastic.
Fig. 5 and 6 show representative plots of (tan
δE′)−1 against (E′)−1 from all pixels of a single AM-FM AFM image of each substrate as well as a linear fit to the data. If the linear fit has low RMSE, the sample is a GMM, SLS, MW or KV material, as detailed in section 2.3 and section S2.2.87,146 GMM, SLS, MW and KV model details can be found in section S1. Fig. 5 shows example model tests for the three poly(HEMA) substrates. Mean fit metrics for all AM-FM AFM images of the poly(HEMA) substrates can be found in Table S2. Fit metrics for each AM-FM AFM image of the 11.4, 1.14, and 0.114 mg poly(HEMA) per cm2 substrates can be found in Tables S3, S4, and S5, respectively. The mean ± standard deviation in the RMSE values of the model test fits to each sample were 0.0376 ± 0.0111 for substrates with 11.4 mg poly(HEMA) per cm2, 0.0499 ± 0.0577 for substrates with 1.14 mg poly(HEMA) per cm2, and 0.1752 ± 0.1395 for substrates with 0.114 mg poly(HEMA) per cm2, indicating that the data can be approximated by a line, and therefore that poly(HEMA) substrates can be modeled with the MW, KV, SLS, or GMM models. The RMSE values, as well as the standard deviation in RMSE increase as poly(HEMA) concentration decreases. These changes are likely the result of thinning poly(HEMA) film structures and variations in bottom effects on the less concentrated substrates.
Most linear fits had m ≈ 0 and b > 0 (Fig. 5A, B and Tables S3–S5), indicating that poly(HEMA) behaves mostly as a MW material. However, some fits exhibited m > 0, and a hyperbolic shape (Fig. 5C and D), indicating that poly(HEMA) also obeys the GMM. In general, m > 0 occurred more as poly(HEMA) concentration decreased, appearing most in substrates with 0.114 mg poly(HEMA) per cm2. Since the GMM appeared more in substrates with lower poly(HEMA) concentrations, which have the thinnest poly(HEMA) films112,113 and likely bottom effects (section 3.2.2), it is reasonable to hypothesize that the GMM corresponds to a convolution of the glass and poly(HEMA) or bottom effects. In other words, poly(HEMA) is a MW material, but transitions to a GMM as the poly(HEMA) film thins and becomes more affected by the underlying coverslip. Regardless, these results confirm that the poly(HEMA) substrates in this study are viscoelastic, as expected from the literature.113,127–131
Fig. 6 shows representative model tests for pureCol substrates. As shown in Table S2, the mean ± standard deviation in RMSE for pureCol substrate measurements performed with an RC800PSA were: 0.22 ± 1.21 for pureCol crosslinked for 30 minutes, 0.05 ± 0.03 for pureCol crosslinked for 2 hours, and 0.03 ± 0.03 for pureCol crosslinked for 24 hours. The mean ± standard deviation in RMSE for measurements performed with an AC240TSA were: 0.31 ± 1.19 for pureCol crosslinked for 30 minutes, 0.17 ± 0.16 for pureCol crosslinked for 2 hours, 0.05 ± 0.02 for pureCol crosslinked for 24 hours. Fit metrics for individual images, as well as the assigned model for the given image can be found in Tables S6–S8. PureCol substrates crosslinked for 30 minutes had the largest variation in RMSE for both cantilevers. This observation is likely due to the fact that sample mechanics were more heterogeneous in this substrate compared to substrates crosslinked for longer times (see section 3.2.2). Regardless, the low RMSE values confirm that pureCol substrates can be modeled as a GMM or one of the GMM's special cases.
For individual AM-FM AFM images of each pureCol substrate, the linear fits all exhibited a nonzero y-intercept, indicating that the substrates should not be modeled as KV materials. Some fits for pureCol substrates crosslinked for 30 minutes (Table S6) had small slopes, and therefore behaved as MW materials (Fig. 6A). Others (Fig. 6B, E, and F) had a slope greater than zero, and therefore obeyed the SLS or GMM. Similar outcomes occurred for substrates crosslinked for 2 (see Table S7) or 24 hours (Table S8). Regardless of substrate, plots with a nonzero slope and y-intercept, while well described by a line, exhibited a slightly curved shape, meaning that the GMM is the best model to describe these samples.87,146
Of the basic models of linear viscoelasticity, the MW model is best to describe samples that are more fluid.7,157 Additionally, pureCol substrates are fluid without crosslinking, and substrate fluidity decreases as the number of crosslinks increases (see section 3.1). Furthermore, samples with longer crosslinking duration, and therefore more crosslinks,124 exhibit MW behavior in the model test less frequently (see Tables S6–S8). These observations suggest the MW material corresponds to regions of a substrate with less crosslinking, and the GMM material corresponds to regions of the sample with more crosslinking.
Model test outcomes on pureCol substrates varied slightly between RC800PSA and AC240TSA cantilevers. The RMSE values were higher for data collected with the AC240TSA cantilever compared to the RC800PSA, due to increased presence of an additional material (green circles in Fig. 6) in AC240TSA model tests that was less apparent in RC800PSA model tests. This second material did not exhibit a large slope, and therefore behaved as a MW material. Additionally, the fact that this material was more present in AC240TSA measurements suggests that the material is related to cantilever/sample interactions, rather than the substrate itself. Since AC240TSAs are more sensitive to pureCol surface layers than RC800PSA cantilevers (section 3.1), the additional MW material in the AC240TSA measurements likely corresponds to surface hydration shells, polymer brushes, or similar surface features. Such features are relatively fluid compared to the bulk, and since the MW model is best to describe samples that are more fluid,7,157 it is reasonable that surface features behave as MW materials.
Together, these results demonstrate that the substrates in this study can be modeled as GMM or MW materials, and are therefore viscoelastic, matching previous literature observations of similar substrates.65–71,113,127–135 Therefore, the measurements in this paper describe viscoelasticity, rather than other time dependent responses such as poroelasticity.
δ at different points on each cell culture substrate are shown in Fig. 7. Before these measurements were obtained, several control experiments were necessary to determine whether PT-AFM nDMA measurements could reliably be performed in liquid.105,107 These controls are detailed in sections S7–S10, and recommendations for performing PT-AFM nDMA measurements on new samples in liquid based on these tests are detailed in section S11.
The first control experiment for liquid PT-AFM nDMA, described in section S7, was performed to evaluate whether hydrodynamic drag105 would impair PT-AFM nDMA measurements in liquid. Hydrodynamic drag depends on the fluid structure near a sample's surface and could affect the sample and reference measurements differently, thereby introducing artifacts to AFM nDMA measurements.105 Therefore, to test these effects, a single sample measurement was analyzed against several reference measurements performed at different heights above the sample.105,107 Hydrodynamic drag affected measurements at some reference heights for particular cantilever/sample pairings. When hydrodynamic drag affected PT-AFM nDMA measurements, discontinuities or oscillations occurred in the measured E′, E′′, and tan
δ (Fig. S4). When no discontinuities or oscillations were observed, results agreed regardless of reference height (Fig. S4). Therefore, for any new sample/cantilever pairing, measurements at different reference heights should be performed to determine the extent of hydrodynamic drag effects for the given system. Reference measurements can be performed at any height where discontinuities and oscillations are not present in the measurements, and where the resulting E′, E′′, and tan
δ match those against other reference heights.
The second control experiment, described in section S8, was performed to ensure that PT-AFM nDMA measurements were performed in the sample's linear viscoelastic regime by comparing PT-AFM nDMA measurements collected on the sample using different force trigger points. Higher trigger points result in larger sample indentations (details in section S4). In the linear viscoelastic regime of a sample, E′, E′′, and tan
δ will not vary with different trigger points because these properties are independent of indentation depth until the sample is deformed outside of the sample's linear viscoelastic regime.7 As shown in Fig. S5–S7, the linear viscoelastic regime varied between samples, and even different points on the same sample. However, a trigger point of 8 nN was in the linear viscoelastic regime of all samples. Higher trigger points occasionally also fell in the linear viscoelastic regime. Therefore, for any new sample, the linear viscoelastic regime of the sample should be determined by performing sample measurements with different indentation depths.
The third control experiment (section S9) tested whether the AFM cantilever affects PT-AFM nDMA results by comparing measurements obtained with RC800PSA and AC240TSA cantilevers. While k′ and k′′ are extensive properties,106,107,158 and therefore expected to change with different cantilevers, tan
δ is intensive and independent of contact geometry106,107,158 and should therefore be the same regardless of cantilever. As shown in Fig. S8, the cantilever did not alter the measured tan
δ, meaning that PT-AFM nDMA is robust to different cantilevers.
The final control experiment (section S10) was performed to test the limits of PT-AFM nDMA. As detailed in section 3.1, certain samples may be too soft and fluid to obtain PT-AFM nDMA measurements. Also described in section 3.1, PT-AFM nDMA may be difficult to perform on samples with strong surface effects, such as surface polymer brushes. To test this hypothesis, a hydrogel synthesized from polydimethylsiloxane (PDMS) was measured by PT-AFM nDMA in liquid. The surface of PDMS hydrogels behaves differently from the bulk due to interfacial differences in the concentration of loose polymer chains and resulting alterations in bulk vs. surface gel swelling and properties.159 These differences cause surface effects that influence bulk property measurements in AFM nanoindentation experiments.159 The reference measurement in PT-AFM nDMA may be unable to account for alterations to cantilever motion due to such effects, since the reference must be obtained when not in contact with the sample, and therefore cannot be collected at the interface. As shown in Fig. S9, and discussed in section S10, the PDMS interface shifted cantilever phase during sample measurements, and thereby rendered the measurements negative and unphysical regardless of reference measurement height. Therefore, PT-AFM nDMA in liquid will not work on samples with unusual interfacial dynamics or with surface polymer brushes because such surfaces influence cantilever motion in a manner that cannot be accounted for by the reference measurement. However, it may be possible to work around such limitations in the future by selecting a cantilever that is less sensitive to such interactions, measuring the sample dry, or using polymer physics models to add correction factors to PT-AFM nDMA calculations. Regardless, these controls show that, for many samples, PT-AFM nDMA can be used to quantify nanoscale sample viscoelasticity in air107 as well as liquid.
δ of the 11.4 mg poly(HEMA) per cm2 substrate are shown in Fig. 7A. The Hertz model was used to calculate PT-AFM nDMA E′ and E′′ in order to keep the contact model consistent between AM-FM AFM, which solely uses the Hertz model,76,86 and PT-AFM nDMA (as described in section 2.4.2).
The shape and magnitude of poly(HEMA) tan
δ measured by PT-AFM nDMA matches those detailed in Table 1 and section S12, and thereby agrees with macroscale literature measurements of poly(HEMA) substrates127 as well as composite poly(HEMA) acrylamide substrates.128E′ and E′′, calculated by applying the Hertz contact model to measured PT-AFM nDMA k′ and k′′, have the expected shape, and are on the order of 105 Pa, which agrees with the higher end of the 103–105 Pa range expected from the literature,127,128 and matches that of substrates made only of poly(HEMA).127 However, it is important to acknowledge that, based on AM-FM AFM measurements (section 3.2.2), a bottom effect correction and, due to the relatively deep sample indentations during PT-AFM nDMA, a different contact model may be more appropriate to represent the tip/sample interaction than the Hertz model. PT-AFM nDMA measurements of tan
δ, E′, and E′′ did not vary with position on the sample. This observation agrees with AM-FM AFM observations that the mechanical properties of the 11.4 mg poly(HEMA) per cm2 sample were homogeneous.
δ measured by PT-AFM nDMA matches those detailed in Table 1 and section S12, and thereby agree with macroscale literature values for pureCol and other collagen substrates.67,122,132–135,140–142
The Hertz contact model145 was used to calculate E′ and E′′ of pureCol substrates in order to ensure the same contact model as AM-FM AFM's calculation of E′ (see section 2.4.2). E′ and E′′ of pureCol substrates measured by PT-AFM nDMA had the expected shape, but were on the order of 105–106 Pa and 104–105 Pa, respectively. Both are three orders of magnitude higher than the expected 102–103 Pa for E′, and 101–102 Pa for E′′ from most of the literature,67,122,132–135,139–141 and one to two orders of magnitude lower than the 107–108 Pa for E′ and 106–107 Pa for E′′ reported in one study.142 This difference between PT-AFM nDMA measurements and literature E′ and E′′ could be due to scaling behavior, since PT-AFM nDMA was performed at the nanoscale, while literature measurements67,122,132–135,139–141 were performed at the macroscale160. Nanoscale moduli can sometimes be several orders of magnitude higher than macroscale moduli, as a result of the natural scaling behavior of polymers.160 Additionally, since the cantilever exhibits a tetrahedral tip geometry, not spherical as assumed in the Hertz model,145 the samples are viscoelastic, and indentation depths are deep in PT-AFM nDMA, the Hertz contact model is likely not the most accurate model of the tip/sample contact. Changing the contact model may resolve some of the discrepancy between PT-AFM nDMA and literature measurements. However, other contact models are not investigated in this study because AM-FM AFM relies on the Hertz model,76,86 and the Hertz model must therefore also be applied to PT-AFM nDMA measurements to ensure that results from each technique can be compared.
The fact that the GMM or MW models apply to pureCol substrates (section 3.2.3) can be exploited to determine whether the offset in PT-AFM nDMA E′ and E′′ compared to the literature is due to scaling behavior or contact model effects by allowing comparison of E′ at low measurement frequencies (f) against elastic moduli from indentation experiments. For GMM materials, as ω = 2πf → 0, E′ → Ec (eqn (S14)) and E′′ → 0 (eqn (S15)). In nanoindentation experiments, indentation speeds are slow, meaning that the measured elastic modulus (E) corresponds to sample behavior at low f, where E = Ec = E′.106,107 Nanoscale collagen E in liquid is on the order of 105–106 Pa calculated by applying the Oliver-Pharr model to nanoindentation measurements,161 106 Pa calculated by applying the Hertz model with a bottom effect correction to nanoindentation measurements,162 108 Pa using optical tweezers,163 and 106 Pa using AFM bending measurements (contact model not stated).164 These nanoscale moduli agree with the measured E′ in PT-AFM nDMA, in spite of varying contact models, and are roughly three to four orders of magnitude higher than the macroscale rheology measurements in the literature. This is the same offset between PT-AFM nDMA and literature measurements, and is independent of contact model. Therefore, collagen DMA at the nanoscale is likely three to four orders of magnitude higher than macroscale control measurements due to scaling behavior.
Together, the fact that all curve shapes and tan
δ measurements agree with the literature demonstrates that the operating principles of PT-AFM nDMA do not interfere with measurements in liquid. Furthermore, in spite of employing the Hertz model, the magnitude offsets in E′ and E′′ are most likely due to scaling behavior, not incorrect contact model selection.
Representative PT-AFM nDMA measurements of pureCol substrates crosslinked with GA for 30 minutes are shown in Fig. 7B. Two points on the sample were measured. The first measurement was performed on a spot with aligned fibrils. The second was performed on a spot without fibrils. E′ was the same for both points. For frequencies less than 100 Hz, E′′ was lower in the spot with fibrils. Therefore, tan
δ at frequencies less than 100 Hz was also lower for the spot containing fibrils. The fact that E′ was the same in both points of the sample is likely related to sample crosslinking, which would restrict movement of collagen polymers when the substrate was deformed,126 regardless of the position measured. Values of E′′ and tan
δ were lower for fibrils at frequencies less than 100 Hz. Therefore, fibrils, and regions of the substrate which contain fibrils, do not dissipate as much energy as regions without fibrils, likely due to alterations in polymer orientation and increased confinement of collagen monomers.
Bundling of collagen into fibrils can alter a multitude of polymer properties, including collagen hydration and electrical properties.165–167 For example, the electrical properties of collagen can be affected by the topography of collagen structures, and play an important role in determining the properties of structures arising from collagen.165–167 Collagen fibrils posses two axes of electric polarization, one in a longitudinal direction (along the length) of the fiber, and one in an axial direction (perpendicular to the length of the molecule) along the fiber.165 When collagen fibrils and fibers align, electric polarization of the resulting structures is maintained.166 Additionally, randomly oriented collagen deposition can cancel some of the electric polarization of collagen structures.167 Structures arising from aligned collagen fibrils maintain electric polarization of the fibrils, while structures of randomly oriented collagen may or may not do the same.165–167 Therefore, it is reasonable to hypothesize that the electrical properties of pureCol substrates, and any resulting hydration shells or other features that depend on electrostatic interactions, are spatially heterogeneous depending on the orientation of collagen molecules in any given region of the sample, and alterations to energy dissipation in different regions of the substrate relate to alterations in the electric polarization, hydration, and intermolecular interactions within these regions as a result of altered collagen topography.
Representative PT-AFM nDMA measurements of pureCol substrates crosslinked with GA for 2 hours are shown in Fig. 7C. Three points were probed on the sample. The first measurement was performed on a small fiber, with many fibrils distributed over the fiber's surface. The second measurement was performed on a larger fiber, without the small fibrils over the surface. The third measurement was performed on an even larger fiber on the sample. E′ and E′′ did not vary with position on the sample for frequencies less than 1000 Hz. At 1000 Hz, E′ and E′′ of the first point increased slightly compared to the others. Similarly, tan
δ of the first point also increased compared to the other points at frequencies above 1000 Hz. Therefore, fibers where collagen fibrils do not completely incorporate themselves into the fiber (point one in Fig. 7C) exhibit altered energy storage and dissipation at high frequencies, compared to fibers where the constituent fibrils are fully incorporated. This observation is potentially due to increased freedom of movement for fibrils that are only partially incorporated into fibers. Regardless, some spatial heterogeneity is present in the mechanical properties at particular frequencies of pureCol substrates crosslinked for 2 hours. Additionally, since two of the three points measured by PT-AFM nDMA exhibited similar mechanical responses, less spatial variation in substrate viscoelasticity may be present than in samples crosslinked for 30 minutes (Fig. 7B).
Measurements of pureCol samples crosslinked for 30 minutes (Fig. 7B) and 2 h (Fig. 7C) exhibited fluctuations around 1000 Hz (red arrows in Fig. 7B and C) due to resonance between the tip and sample, not sample properties. Such resonance could emerge from a number of interactions. However, most of the measurement curve was unaffected by the resonance at 1000 Hz, and since behavior at 1000 Hz was not a focus in this article, the artifacts did not negatively impact measurement results. If desired, resonance effects can be eliminated by applying additional smoothing or using a different cantilever to perform PT-AFM nDMA measurements.
Representative PT-AFM nDMA measurements of pureCol substrates crosslinked with GA for 24 hours are shown in Fig. 7D. Two points were probed on the sample. The first measurement was performed on a region of clumped collagen on the substrate. The second measurement was performed on a point between collagen clumps. The measured E′, E′′, and tan
δ did not vary between the two points. The lack of variation in the mechanical properties of pureCol substrates crosslinked for 24 hours is likely related to the crosslinking in the sample. With more crosslinks, movement of collagen polymers within the substrate would be restricted, thereby limiting spatial heterogeneity in the mechanical properties.126
δ over the measured frequencies for all substrates measured by both AM-FM AFM and PT-AFM nDMA.
![]() | ||
| Fig. 8 Comparison of substrate viscoelasticity. Measurements of pureCol substrates crosslinked with GA for 30 minutes (magenta), 2 hours (blue), and 24 hours (cyan), in addition to a poly(HEMA) substrate at a concentration of 11.4 mg poly(HEMA) per cm2 of substrate surface area (black) are shown. The mean value of all PT-AFM nDMA measurements (lines), as well as AM-FM AFM measurements (points), are shown for each substrate. For AM-FM AFM measurements, triangles pointing down represent measurements of pureCol substrates obtained with an AC240TSA, triangles pointing up represent pureCol measurements obtained with an RC800PSA, and circles represent AM-FM AFM measurements of poly(HEMA) substrates with 11.4 mg poly(HEMA) per cm2 of sample surface area. Shading with dotted lines represents the standard deviation of PT-AFM nDMA measurements. Error bars represent the standard deviation of AM-FM AFM measurements. Filled markers represent AM-FM AFM measurements. Open markers represent values calculated from AM-FM AFM measurements as previously described.87,146 | ||
Sample relaxation time as a function of frequency was calculated using principles of the GMM. As described in section S1, the GMM can be thought of as N different SLSs connected in parallel.87,169 The nth arm of the GMM has a relaxation time τn. Each of the N SLSs in the GMM has resonance frequency fn = 1/τn.169 Therefore the nth SLS in a GMM contributes most to E′, E′′, and tan
δ when the arm is excited by a stimulus with frequency f = 1/τn,169 meaning that the GMM's mechanical response at a particular frequency can be modeled by the SLS representing the dominant, resonating arms of the GMM at the particular excitation frequency.168 It is therefore possible to calculate τr(f) of the sample by recalling that, for the SLS, E′ = Ec + τrωE′′ (eqn (S11)). Therefore, τr can be calculated from PT-AFM nDMA E′ and E′′ viaeqn (6).
![]() | (6) |
The value of Ec is the value of E′ for PT-AFM nDMA measurements at low frequencies (see eqn (S14)). While E′, Ec, and E′′ are calculated from AFM measurements by applying contact models, the geometric contribution of the contact to each cancels by taking the ratio of [E′(f) − Ec]/E′′(f) in eqn (6). Therefore, as with tan
δ,87,107τr calculated in this manner is also independent of contact geometry. At AM-FM AFM measurement frequencies, τr can be calculated by applying similar principles, as previously published.87,146 Mean relaxation time as a function of frequency for each substrate is shown in Fig. 8D.
As shown in Fig. 8, AM-FM AFM values align with PT-AFM nDMA values, demonstrating that each measurement technique agrees with the other. E′ and E′′ (Fig. 8A and B) of all substrates increased with increasing frequency. A sharper increase in each modulus corresponding to the glass or similar transition,157,168 started between 103 and 104 Hz for pureCol substrates and around 10 Hz for poly(HEMA) substrates. In spite of the fact that the glass transition of poly(HEMA) substrates began around 10 Hz, AM-FM AFM measurements of E′ and E′′ are similar for poly(HEMA) and pureCol substrates. Therefore, the glass transition is broader for poly(HEMA) than for pureCol.
AM-FM AFM model tests of poly(HEMA) substrates (Fig. 5) demonstrated that poly(HEMA) behaves as a MW material, but can behave as a GMM as the result of effects from the glass underlying the poly(HEMA). For MW materials, E′ and E′′ ∼ 0 at low frequencies, and increase as frequency increases (see eqn (S5) and (S6)). However, poly(HEMA) E′ and E′′ are nonzero at 0.1 Hz. This behavior is more consistent with the GMM, which has a nonzero E′ at low frequencies and a gradual increase in E′ and E′′ with frequency (details in section S1 and eqn (S14)–(S16)).87,168 While this observation could be due to a bottom effect,156 it is also possible that E′ → 0 for frequencies lower than 0.1 Hz, the lowest frequency measured in this article. The latter is the most likely case because literature measurements of poly(HEMA) exhibit similar shapes to the PT-AFM nDMA measurements for f > 0.001 Hz.127,128 AM-FM AFM model tests of pureCol substrates (Fig. 6) demonstrated that these substrates behave according to the MW or GMM models. This observation is supported by PT-AFM nDMA measurements, which show trends in E′ and E′′ characteristic of the GMM (details in section S1 and eqn (S14)–(S16)).87,168 Therefore, PT-AFM nDMA measurements and AM-FM AFM model tests are in agreement about the viscoelastic behavior of these substrates. Additionally, collagen substrates have previously been modeled as MW materials, but exhibit rheology curves consistent with GMM behavior at f > 0.1 Hz,133 agreeing with the combined AM-FM AFM and PT-AFM nDMA measurements in this study.
Of the pureCol substrates, pureCol crosslinked for 30 minutes exhibited the highest E′ and E′′ in both AM-FM AFM (Fig. 4B) and PT-AFM nDMA (Fig. 8). As detailed in section S12, previous literature reported that increased GA crosslinking can increase122,140,141 or decrease142 both the storage and loss moduli, depending on measurement preloading conditions.67,126 PT-AFM nDMA trends agree with those observed on samples with moduli on the order of 106–108 Pa measured in liquid,142 and are therefore not unreasonable. GA crosslinking modulates viscoelasticity of collagen substrates by restricting the movement of fibrils within the substrate, rather than by directly altering the mechanical properties of the fibrils.126 With less crosslinking, polymer movement is only partially restricted, and collagen chains have more freedom to deform, interact with one another, and interact with hydration layers. In other words, there are more ways to store and dissipate energy in response to deformation in substrates with less crosslinking. As crosslink density increases, the relatively lower E′ and E′′ likely arise due to increased restriction of collagen fibril movement limiting interactions that store and dissipate energy.
E′ of poly(HEMA) substrates was comparable to pureCol substrates crosslinked for 2 or 24 hours. Poly(HEMA) E′′ was comparable to pureCol substrates crosslinked for 30 minutes. Therefore, poly(HEMA) exhibited a higher ratio of E′′/E′ than pureCol samples. As shown in Fig. 8C, tan
δ of poly(HEMA) substrates was roughly one order of magnitude higher than that of pureCol substrates. Alterations in pureCol tan
δ with frequency varied between the substrates. In samples crosslinked for 30 minutes, tan
δ was constant for frequencies less than 103 Hz, then began to increase. For substrates crosslinked 2 and 24 hours, tan
δ steadily increased with increasing frequency.
Unlike E′ and E′′, literature measurements of tan
δ with different GA crosslinking agree and demonstrate that tan
δ is 1.2–4 fold lower for substrates with more crosslinking.122,140–142 PT-AFM nDMA results showed that tan
δ of pureCol substrates crosslinked for 30 minutes was roughly three times higher than that of substrates with longer crosslinking durations at measurement frequencies less than 10 Hz, and are therefore in agreement with the literature. Additionally, the observation that E′, E′′, and tan
δ were similar in substrates crosslinked for 2 and 24 hours agrees with literature measurements that also found more GA crosslinking decreases the difference between rheology curves.122,140–142 Therefore, PT-AFM nDMA measurements of crosslinking effects agree with those expected from the literature (see Table 1 and section S12 for more details on literature expectations).
The value of τr(f) at high frequencies is similar for all substrates. At frequencies less than 10 Hz, τr(f) is roughly one order of magnitude shorter for poly(HEMA) and pureCol substrates crosslinked for 30 minutes than for pureCol substrates crosslinked for 2 or 24 hours. Since the differences between E′ of these two groups are smaller than the differences in E′′ (Fig. 8A and B), the longer τr at low frequencies are the result of greater changes in energy dissipation relative to energy storage between the two groups. For most measurement frequencies, τr is longer in pureCol substrates crosslinked for 2 or 24 than substrates crosslinked for 30 minutes. This trend of longer relaxation times with more GA crosslinking agrees with previous literature.67
At frequencies less than 1 Hz, τr of pureCol substrates crosslinked in GA for 2 hours is closest to that of pureCol substrates crosslinked for 24 hours. Between 1 and 100 Hz, τr of pureCol substrates crosslinked for 2 hours transitions to values similar to those of pureCol crosslinked for 30 minutes. At frequencies around 300 Hz, all three pureCol substrates exhibit similar τr. Substrates with 2 hours of GA crosslinking have an intermediate distribution of τr between the other pureCol substrates, likely because the crosslinking in this sample is also the intermediate of the pureCol substrates.
δ measurements and poly(HEMA) E′ and E′′ measurements agreed with the literature (section 3.3.1 and Fig. 8). While pureCol E′ and E′′ were three orders of magnitude higher than macroscale literature controls, comparison of these values to nanoindentation measurements in the literature suggests that this offset is due to scaling behavior between nanoscale and macroscale measurements, and is therefore not a failure of PT-AFM nDMA. Together, these results demonstrate that PT-AFM nDMA can be successfully employed in liquid environments to quantify nanoscale viscoelastic behavior in biologically relevant conditions over a broad and continuous range of frequencies.
This work highlights several factors to consider when performing PT-AFM nDMA in liquid. First, the technique will not work in liquid on samples with unusual interfacial dynamics or with surface polymer brushes because such surfaces influence cantilever motion in a manner that cannot be accounted for by the reference measurement. While it may be possible to work around such limitations in the future by selecting a cantilever that is less sensitive to interfacial interactions, measuring the sample dry, or using polymer physics models to add correction factors to PT-AFM nDMA calculations, this investigation is left to future work. Second, when performing PT-AFM nDMA, each new cantilever/sample pairing should undergo similar control measurements to those described in section 3.3 and sections S7–S11. Specifically, hydrodynamic drag effects should be evaluated by comparing the sample measurement to reference measurements obtained at different heights from the sample. The linear viscoelastic regime of the sample should be determined by obtaining sample measurements at different indentation depths. An optional control is to test cantilever effects by performing measurements with different cantilevers. Third, tan
δ and τr measurements are robust to contact model because the geometric features of the tip/sample contact for these properties cancel for both quantities. Therefore, tan
δ and τr are the most robust PT-AFM nDMA measurement properties (section 2.3 and 8). The measured E′ and E′′ are calculated by applying a contact model (section 2.3), and effects of tip/sample interaction geometry must therefore be considered for these properties.
In spite of the fact that the Hertz contact model was employed to calculate PT-AFM nDMA E′ and E′′, continuous measurement curves with the expected shape based on macroscale rheology measurements were still obtained, meaning that curve shape is independent of contact model. This result is expected because many contact models shift k′ and k′′ by a constant (the value of which is calculated by the contact model), and therefore move the curve up or down, but do not alter curve shape.107 Therefore, if an incorrect contact model is used, PT-AFM nDMA can still inform relative comparisons of E′ and E′′ across locations on a single sample or different samples, just not the exact magnitude of each quantity. If the only objective is to compare whether one curve is higher than another, then this comparison can be made even when an incorrect contact model is applied. However, more care must be applied to select the appropriate contact model if E′ and E′′ order of magnitude is of particular interest to the given study.
It is important to emphasize that tan
δ is independent of contact model, because the geometric factors in E′ and E′′ cancel when taking the ratio of the two.87,107 Similarly, because the geometric factors of the tip/sample contact cancel in the calculation of τr (see section 3.4), time responses of a sample can be analyzed even if the wrong contact model is applied. If the best contact model for the given tip/sample interaction is unknown, calculation of E′ and E′′ can be avoided, and tan
δ can still be considered alone. Alternatively, as in this article, the Hertz model can be employed with multiple controls for the measured value of E′ and E′′ to ascertain whether magnitude shifts, if present, are due to scaling or contact model effects. Furthermore, the Hertz model is widely used in AFM.9,75,76 If the Hertz model is used in place of a more accurate contact model, PT-AFM nDMA measurements can be combined with and compliment measurements from other techniques such as AM-FM AFM, as described in section 3.4.
Cells probe their substrate at low frequencies.170 Therefore, the mechanical properties of substrates at low frequencies are particularly relevant to what cells sense on the substrate.170 At low frequencies, pureCol substrates crosslinked with GA for 2 or 24 hours exhibited longer relaxation times, by roughly one order of magnitude, than poly(HEMA) substrates and pureCol substrates crosslinked for 30 minutes. While both energy storage and dissipation were different between the slow and fast τ substrates, alterations to the relaxation times were the result of greater differences in energy dissipation than differences in energy storage between the slow and fast substrates. Since E′′ = 0 if a substrate has no viscosity,7,9,146,168 these observations demonstrate that it is essential to measure substrate viscoelasticity, rather than treating substrates as purely elastic, to obtain a full picture of how a substrate's properties affect cell behavior.
The different substrate time responses at low frequencies (Fig. 8D) have interesting implications for cell behaviors on the substrates. It is already hypothesized that shorter τr promotes ECM deposition and remodeling, as well as differentiation of cells within the substrate, and reduces proliferation and migration.61 Longer τr promotes the opposite.60 On collagen substrates, cells proliferate more,171,172 perform less ECM remodeling and contraction,171,172 and differentiate less171 on substrates crosslinked with GA. Cells also exhibit increased seeding efficiency (meaning more cells attach to the substrate when they are seeded onto the substrate), and infiltrate the substrate faster (show increased invasion and migration) with more GA crosslinking.172 Therefore, cells on highly crosslinked collagen substrates exhibit the same behaviors as cells on substrates with longer time responses.60,61,171,172 The pureCol findings in this article show that substrates with more GA crosslinking exhibit longer time responses, supporting the hypothesis that longer substrate time responses promote cell attachment, proliferation, and migration (invasion and infiltration), and hinder ECM remodeling and differentiation.
Poly(HEMA) measurements further support the notion that substrate time responses relate to cell behaviors. The inability of cells to attach to poly(HEMA)112 supports the hypothesis that shorter substrate relaxation times result in decreased cell attachment. Reduced DNA synthesis,112 reduced cell activation,136 reduced cell migration, and reduced cell signaling113 by cells on poly(HEMA) coincide with the hypothesized effects of shortened response times.61 Additionally, it is interesting to note that poly(HEMA) promoted the formation of multiple nuclei within malignant melanoma cells.113 In tissues, cells with multiple nuclei (polykaryons) normally form as the result of immune, muscle, or placental cell differentiation processes.173,174 Therefore, the formation of polykaryons on poly(HEMA) could suggest that these cells underwent some type of differentiation process. If this is the case, this observation also agrees with shorter time responses promoting cell differentiation.
It is interesting to note that poly(HEMA) and pureCol crosslinked for 30 minutes had similar time responses at low frequencies. In spite of the similar substrate time responses, cells attach and spread on pureCol,171,172 but not to poly(HEMA).112 Therefore, other properties of the substrate also play an important role in cell behavior. For example, the hydrophilic nature of poly(HEMA) plays an important role in preventing cell attachment.113 Additionally, it is already known that poly(HEMA) alters the mechanical properties of cells, likely by altering cytoskeleton dynamics.136 Together, these observations suggest that chemical properties, and likely other properties such as electrical, and possibly magnetic properties, of a substrate alter the effects of substrate time responses by altering cell mechanics, and thereby the sensitivity of the cells to substrate mechanics. The different physical properties of a substrate likely combine to regulate cell mechanics, and thereby cell activities. Regardless, the results in this article combined with the literature describing cell behaviors on similar substrates build upon previous work60,61 suggesting that shorter substrate time responses promote ECM remodeling and differentiation and hinder cell attachment, proliferation, and migration (invasion and infiltration), while the opposite is true for longer substrate time responses.
Supplementary information: a PDF containing supplementary explanations of viscoelasticity, AFM technique principles, and data analysis, details of control experiments when performing PT-AFM nDMA in liquid, a review of the literature measurements used as controls in this study, supplementary figures, and supplementary tables. See DOI: https://doi.org/10.1039/d5nr01790d.
ková-Smr
ková, T. Remmler, M. Lap
íková and K. Du
ek, Rheological properties of homogeneous and heterogeneous poly(2-hydroxyethyl methacrylate) hydrogels, Polym. Int., 2012, 61, 328–336 CrossRef CAS.
ek, Mechanical Behavior of Hydroxyalkyl Methacrylate Polymers and Copolymers, J. Macromol. Sci., Part C: Polym. Rev., 1973, 9, 3–47 CrossRef.| This journal is © The Royal Society of Chemistry 2025 |