Open Access Article
Tatjana S.
Münster
abc,
Theo M.
Jenk
*ac,
Anja
Eichler
ac,
Geunwoo
Lee
cd and
Margit
Schwikowski
abc
aPSI Center for Energy and Environmental Sciences, Villigen PSI, Switzerland. E-mail: theo.jenk@psi.ch
bDepartment of Chemistry, Biochemistry and Pharmaceutical Sciences, University of Bern, Bern, Switzerland
cOeschger Centre for Climate Change Research, University of Bern, Bern, Switzerland
dClimate and Environmental Physics, Physics Institute, University of Bern, Bern, Switzerland
First published on 6th October 2025
Ice cores serve as unique paleo-archives allowing access to long-term records of trace elements, which are important for our understanding of global biogeochemical cycles and air pollution. However, analysis of trace elements in ice cores is a challenge, because of very low concentration levels and their presence in dissolved and particulate form. The commonly used and well-established technique for analysis of trace elements in ice cores is inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). Recently, inductively coupled plasma time of flight mass spectrometry (ICP-TOF-MS) was introduced as a new, promising technique. Due to its fast acquisition time for the near-full mass spectral range, it allows for the detection of short transient signals, offering the opportunity to determine the elemental composition of single particles. In this study, the performance of this new technique for analyzing total trace element concentrations was tested and compared to the one established in the field of ice core research. The focus was on sensitivity, precision, and optimization of sample preparation in sections from two ice cores (Colle Gnifetti, Cerro Negro), characterized by different impurity levels. The performance of the ICP-TOF-MS was excellent for the investigated trace elements within the nominal mass range from 23 to 238, except for 45Sc because of insufficiently resolved mass interferences. This is very promising for many applications in ice core research, especially in view of the great benefit to analyze single particles simultaneously in the same sample.
Inductively coupled plasma time of flight mass spectrometry (ICP-TOF-MS) was introduced for TE analyses in the 1990ies,15,16 and was recently made commercially available again.17 The TOF mass spectrometer is capable of recording full mass spectra of short transient signals due to its fast acquisition rate (i.e. short dwell time) in the range of milliseconds,18 compared to seconds typical for ICP-SF-MS scans. This opens up the possibility to investigate the elemental composition of single particles.18–20 The potential of ICP-TOF-MS for single particle analysis has already been demonstrated, e.g. for engineered nanoparticles in consumer products or nanoparticles in chemical mechanical planarization suspensions,21–23 and in a more recent study was also investigated for engineered particles in the micrometer range.24 Such nanoparticles usually consist of a single element or a single element plus oxygen, whereas particles in ice cores have a more complex composition. A first application of ICP-TOF-MS for TE analyses in ice cores showed an overall good agreement for the concentrations of Na and Ca with the previously used methods, i.e. absorption and fluorescence spectroscopy, respectively.19 Except for the latter two elements, which are present predominantly in the dissolved form, the performance of the ICP-TOF-MS for TE analyses in ice core samples has not been characterized in detail.
The motivation of this study is to compare total TE concentrations in glacier ice samples determined by ICP-TOF-MS and the established ICP-SF-MS technique. The goal was to assess whether the newer ICP-TOF-MS technique, with its added capability for single-particle analysis, can also achieve accuracy and precision in ultra-trace element concentration measurements comparable to those traditionally obtained with ICP-SF-MS. We thereby focus on limits of detection (LoD), precision, and the comparability of absolute values and trends in TE concentrations. The ice samples were prepared from ice cores extracted from two glaciers, Cerro Negro (CN; Andes, Chile) and Colle Gnifetti (CG; Alps, Switzerland). The Cerro Negro glacier is heavily affected by melt processes and TE concentrations are generally low. The Colle Gnifetti is a cold glacier, and samples were taken from a section containing both (visibly) clean ice and mineral dust layers originating from the Sahara. The samples from these two glaciers therefore cover a wide range of concentration levels and a high variety in the TE composition. Accounting for the fact that the two ICP instruments are located at different institutions, we first optimized ice sample preparation with respect to acidification time and the possibility of sample preservation prior to the therefore required transport. This allowed to ensure comparable sample conditions, avoiding any potential bias unrelated to the instruments. Since the ultimate goal of future studies using the ICP-TOF-MS is to also determine the TE composition of the single particles in the ice samples, we here applied very short acidification times for minimal dissolution. Accordingly, the acidification related effects on concentration levels were investigated on much shorter timescales than in previous studies.11,12,14
For both cores, parallel samples from each depth were prepared identically for analysis with the two ICP mass spectrometers as follows. Ice samples were cut in the −20 °C cold room of the PSI, using a stainless-steel band saw with a Teflon coated saw guide and table surface. To remove potential contamination from drilling and core handling, an inner stick with a cross section of 1.6 × 1.6 cm was cut in segments with a sampling resolution of 4.4 to 6.0 cm for the Cerro Negro core (n = 112) and of 5.5 cm for the Colle Gnifetti core (n = 26). For the Colle Gnifetti core, the two parallel samples were obtained at the same time. This was different for the Cerro Negro core, where the parallel samples were cut in two different campaigns more than two years apart, resulting in reduced precision regarding the exact depth alignment. After cutting, samples were additionally scraped with a ceramic knife to remove around 1 mm of the cutting surface and the saw dust, both potentially contaminated by the sawblade.9,27 The decontaminated samples were then stored in 50 ml polypropylene tubes (Sarstedt, Nümbrecht, Germany), pre-cleaned by rinsing five times with ultrapure water (UPW; 18 MΩ cm quality, Mili-Q® Element system, Merck Millipore, Burlingon MA, USA).
Parallel to the samples, artificial ice blanks prepared from UPW were cut. All samples and blanks were taken out from the freezer 1.5 h before analysis and rinsed with UPW for final decontamination. Afterwards they were transferred into 50 ml polypropylene tubes (pre-cleaned by soaking for three days in 0.2 M ultrapure HNO3; Optima™, Fisher Chemical, Loughborough, UK), then placed in a water bath at around 25 °C for melting and 1.5 min before analysis were acidified with ultrapure HNO3 to a final concentration of 0.2 M. Within that time, they were transferred into 1.5 ml polystyrene auto-sampler vials (Sarstedt, Nümbrecht, Germany, precleaned three times with 0.2 M ultrapure HNO3), which were spiked before with 3 μl 103Rh-standard (TraceCERT, Sigma-Aldrich, Germany), leading to a final concentration of 0.01 μg L−1 for analysis. For the ICP-TOF-MS, the 103Rh-standard was continuously introduced into the sample stream, obtaining a final concentration of 0.5 μg L−1.
For examining the response of TE concentrations to different acidification times ranging from 1.5 min to 4 h (using ultrapure HNO3), aliquots of an ice sample from the Cerro Negro glacier core were analysed with ICP-SF-MS. Additionally, six samples from the Cerro Negro core were re-frozen after acidification and re-analysed one week later.
The excellent mass resolution of the ICP-SF-MS of up to m/Δm = 10′000 allows for high sensitivity and a low noise level.10,28,29 In our application, after a take-up time of 1.5 min to reach signal stabilization, the sample was measured for 3.8 min.
First, 14 scans (i.e., measurements per mass peak) over the complete mass spectrum, from mass-to-charge ratio (m/z) 7 to 254, were acquired in low resolution (m/Δm = 300), followed by 14 scans of a narrower mass range (m/z 7–103) in medium resolution (m/Δm = 4′000). The acquisition time per scan for the complete mass spectrum in low resolution was 9 s (7 s for the m/z range in mid resolution), with the automatic switch between resolutions requiring 5 s. Note that for subsequent data processing and evaluation, only the raw data from the higher-resolution scans (medium resolution) were used for the m/z range of 23 to 66. The instrument was tuned daily to optimize sensitivity, signal stability and peak separation by adjusting gas flow rates and ion-optics settings. Also, each day, a mass calibration was performed. Due to known limitations of the ICP-TOF-MS for low masses (see below), only 35 TEs within the m/z range of 23–238 were analysed (Table 1).
| a Internal standard. | ||
|---|---|---|
| ICP-SF-MS | Low resolution (m/Δm = 300) | 85Rb, 88Sr, 90Zr, 95Mo, 103Rha, 109Ag, 111Cd, 121Sb, 133Cs, 138Ba, 139La, 140Ce, 141Pr, 146Nd, 147Sm, 153Eu, 172Yb, 182W, 205Tl, 208Pb, 209Bi, 232Th, 238U |
| Medium resolution (m/Δm = 4′000) | 23Na, 24Mg, 27Al, 44Ca, 45Sc, 51V, 52Cr, 55Mn, 56Fe, 59Co, 60Ni, 63Cu, 66Zn, 103Rha | |
| ICP-TOF-MS | m/Δm = 1′800–2′000 | 121Sb, 133Cs, 138Ba, 139La, 140Ce, 141Pr, 146Nd, 147Sm, 153Eu, 172Yb |
| m/Δm = 2′000–2′500 | 23Na, 24Mg, 27Al, 44Ca, 51V, 52Cr, 55Mn, 56Fe, 59Co, 103Rha, 88Sr, 109Ag, 111Cd, 182W | |
| m/Δm = 2′500–3′000 | 45Sc, 60Ni, 63Cu, 85Rb, 90Zr, 95Mo, 205Tl, 208Pb, 209Bi, 232Th, 238U | |
| m/Δm > 3′000 | 66Zn | |
The ICP-TOF-MS was equipped with a collision cell (Q-Cell, filled with 7% H2 in He gas). The cell reduces argon interferences and leads to an improved mass resolution.19 After daily performed instrument tuning, ICP-TOF-MS analyse was conducted with achieved mass resolutions of m/Δm = 1′800–3′100 (Table 1). No specific tuning to optimize for low m/z values was applied, as this would come at the cost of lower sensitivity for TEs with m/z above ∼150.30 Therefore, the mass range measured by ICP-TOF-MS was limited and TEs evaluated in the following for instrument comparison were considered only within the range of m/z 23 (23Na+) to 238 (238U+). For the ICP-TOF-MS, this mass range was acquired using a dwell time of 0.25 s, enabled by its much faster acquisition speed. While lower dwell times would be possible (and necessary) for single particle analysis, this study focused on total TE concentrations; therefore, a longer dwell time was prioritised to reduce the volume of acquired data significantly. After a take-up time of 1.5 min to reach signal stabilization, each sample was measured for only 1 min, still resulting in a much higher total of 242 measurements per mass peak compared to the ICP-SF-MS. The same 35 TEs as for the ICP-SF-MS were analysed, also measuring three replicates for each sample.
To ensure comparable conditions, the same inlet system (Apex Q, Elemental Scientific, Omaha NE, USA) equipped with a 100 μL microflow self-aspirating PFA nebulizer (Elemental Scientific, Omaha NE, USA) was used for both instruments. Droplets produced in the nebulizer were heated to 100 °C in a cyclonic spray chamber to evaporate the water, which was removed subsequently in a Peltier cooled condenser (2 °C). The wastewater was discharged through a separated waste capillary, while the resulting dry aerosol was injected into the plasma. Producing such a dry aerosol increases the sensitivity by a factor of 3–10 (ref. 31–33) and therefore lowers the limits of detection. For the analysis at both instruments, the nebulizer liquid flow was 400 μL min−1. Samples were introduced into the inlet system with an autosampler (CETAX ASX-260, Teledyne Cetac, Omaha NE, USA for the ICP-SF-MS; microDX, Elemental Scientific, Omaha NE, USA for the ICP-TOF-MS).
For external calibration, the procedure from previous studies27,34 based on a dilution series (n = 7) of a multi-element standard (Spex CertriPrep, Inc., Metuchen, NJ, USA) was used. The concentrations of the TEs in the calibration standards were adjusted to cover their varying levels in glacier ice by diluting the stock solution from 1
:
1 to 1
:
2′000. The calibration function was obtained by linear regression and the corresponding correlation coefficients were generally higher than 0.9993.
Obtained concentration values were further processed, applying a blank correction, for both, analytical and procedural blanks. Analytical blanks (0.2 M HNO3 in UPW) were prepared daily to determine the background contamination of the current laboratory process. Procedural blanks (frozen UPW) were treated like ice samples (see samples and sample preparation) to determine potential contamination introduced during sample preparation. For the blank correction daily averages of at least 9 analytical blanks were used. Mean procedural blanks were determined from a total of 40 frozen UPW blanks for all elements except Na, Al, Ca, Cu, and Ba. For these TEs the procedural blanks varied from cutting session to cutting session and for correction individual blanks were used.
Blank-corrected concentration values below the method limit of detection were replaced by half of the LoD value. For each instrument, the LoD was defined as three times the standard deviation of all analytical blank measurements, following the removal of statistical outliers from the blank ensemble using the interquartile range (IQR) method. The analytical precision depends on the concentration level and is here reported as an average value over the concentration range defined by the mean concentrations measured in the two ice cores (Colle Gnifetti and Cerro Negro). The lower bound of this range is set to be at least three times the determined LoD. It was assessed by treating the daily measured dilutions of the multi-element standard within the defined concentration range like a sample during raw data post-processing. For the same concentration range, the instrumental precision was determined from the pooled standard deviation of triplet measurements performed on the ice core samples (same vial, measured sequentially). For determination of the analytical accuracy, a sample of a certified reference material (CMR; rainwater, TMRAIN-04, National Research Council of Canada, Burlington, Canada) was analysed at least once at the end of each measurement sequence, in a 20-fold dilution to result in a concentration range comparable to the one in ice core samples.
To investigate the agreement between the ice-core TE concentrations obtained with the ICP-SF-MS and the ICP-TOF-MS, t-tests were used to compare the ice core concentration averages, and Pearson correlation analyses was conducted to compare the temporal variability of the records. For not normally distributed data, a t-test can be performed, when the number of samples is larger than 30.35 This was done on both ice core sections, although for Colle Gnifetti the number of samples is 26. For calculating the averages, a TOF-MS/SF-MS concentration pair was discarded if one or both values were ≤LoD, since the LoDs of the two instruments are different for all TEs. This concerns primarily the Cerro Negro ice core samples since TE concentrations are much lower than in the Colle Gnifetti core. For the Cerro Negro samples, a 3-point moving average was applied before correlation analyses to account for the less precise depth alignment. In addition, for selected TEs, Bland–Altman plots36 were produced to analyse in detail the agreement between the data sets obtained with the two instruments.
| Element | LoD [ng L−1] | Procedural blanks [ng L−1] | Precisionb [%] | Cerro Negro, CN (n = 112) | Colle Gnifetti, CG (n = 26) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| SF | TOF | SF and TOF | SF | TOF | Avg (SF) [ng L−1] | Avg (TOF) [ng L−1] | r | Avg (SF) [ng L−1] | Avg (TOF) [ng L−1] | r | |
| a For TEs susceptible to contamination, the procedural blanks varied from cutting-to-cutting session. For correction, individual blanks as listed below were thus used. b Precision depends on concentration and is here shown for the range between CN and CG averages, with the lower limit constrained to be at least 3× the LoD (higher of the two). | |||||||||||
| 23Na | 207 | 209 | 6 | 13 | 3′300 ± 500 | 4′100 ± 400 | 0.13 | 110′000 ± 26′000 | 120′000 ± 25′000 | 0.96 | |
| 24Mg | 57 | 57 | 120 ± 20 | 5 | 8 | 1′300 ± 150 | 2′200 ± 220 | 0.87 | 100′000 ± 27′000 | 120′000 ± 34′000 | 0.96 |
| 27Al | 179 | 244 | 3 | 2 | 14′800 ± 1′900 | 16′200 ± 1′700 | 0.88 | 190′000 ± 51′000 | 200′000 ± 50′000 | 0.99 | |
| 44Ca | 280 | 470 | 8 | 6 | 5′100 ± 750 | 7′600 ± 1100 | −0.16 | 870′000 ± 270′000 | 900′000 ± 270′000 | 0.89 | |
| 45Sc | 0.2 | 11 | <LoD | 5 | 15 | 9 ± 2 | 31 ± 3 | 0.75 | 40 ± 9 | 140 ± 30 | 0.95 |
| 51V | 7.8 | 30 | <LoD | 8 | 8 | 65 ± 7 | 72 ± 8 | 0.88 | 730 ± 150 | 730 ± 130 | 0.98 |
| 52Cr | 1.5 | 3.0 | 4.8 ± 1.8 | 7 | 8 | 24 ± 3 | 28 ± 6 | 0.39 | 380 ± 90 | 390 ± 90 | 0.97 |
| 55Mn | 2.3 | 5.4 | 6.3 ± 3.3 | 4 | 8 | 140 ± 13 | 170 ± 18 | 0.88 | 4′900 ± 1′200 | 5′000 ± 1′200 | 0.99 |
| 56Fe | 33 | 113 | <LoD | 6 | 8 | 17′000 ± 2′300 | 18′000 ± 2′000 | 0.93 | 150′000 ± 38′000 | 140′000 ± 32′000 | 0.97 |
| 59Co | 0.25 | 0.28 | 0.25 ± 0.05 | 5 | 7 | 4.1 ± 0.4 | 5.2 ± 0.5 | 0.74 | 110 ± 20 | 100 ± 20 | 0.96 |
| 60Ni | 2.7 | 1.7 | 6.3 ± 2.5 | 4 | 4 | 18 ± 2 | 22 ± 4 | 0.82 | 300 ± 50 | 300 ± 50 | 0.96 |
| 63Cu | 4.2 | 2.0 | 9 | 11 | 120 ± 12 | 120 ± 12 | 0.85 | 330 ± 60 | 330 ± 60 | 0.85 | |
| 66Zn | 220 | 330 | <LoD | 15 | 18 | 470 ± 80 | 750 ± 170 | 0.13 | 1′400 ± 160 | 1′500 ± 180 | 0.88 |
| 85Rb | 0.73 | 0.62 | 2.7 ± 0.5 | 5 | 5 | 30 ± 3 | 40 ± 4 | 0.91 | 390 ± 110 | 380 ± 90 | 0.97 |
| 88Sr | 1.13 | 1.1 | 5.0 ± 1.8 | 8 | 5 | 26 ± 3 | 52 ± 4 | 0.83 | 4′500 ± 1′500 | 4′600 ± 1′600 | 1.00 |
| 90Zr | 0.27 | 0.68 | 9.4 ± 3.0 | 6 | 17 | 5.9 ± 0.7 | 6.7 ± 1.0 | 0.80 | 140 ± 30 | 150 ± 40 | 1.00 |
| 95Mo | 0.51 | 0.52 | 2.8 ± 0.3 | 8 | 9 | 3.3 ± 0.3 | 3.7 ± 0.5 | 0.49 | 20 ± 3 | 21 ± 3 | 0.96 |
| 109Ag | 0.11 | 0.21 | 0.3 ± 0.1 | 21 | 23 | 2.1 ± 0.2 | 1.2 ± 0.1 | 0.62 | 2.9 ± 0.5 | 2.9 ± 0.4 | 0.98 |
| 111Cd | 0.12 | 0.21 | 0.4 ± 0.3 | 8 | 7 | 0.5 ± 0.1 | 3.0 ± 1.1 | −0.01 | 14 ± 2 | 15 ± 2 | 0.94 |
| 121Sb | 0.70 | 0.54 | 2.9 ± 4.2 | 5 | 8 | 4.7 ± 0.6 | 5.2 ± 0.6 | 0.81 | 30 ± 5 | 30 ± 4 | 0.94 |
| 133Cs | 0.12 | 0.13 | 0.3 ± 0.1 | 5 | 8 | 14 ± 2 | 15 ± 2 | 0.90 | 25 ± 6 | 24 ± 5 | 0.98 |
| 138Ba | 2.4 | 10.5 | 6 | 5 | 82 ± 9 | 127 ± 10 | 0.75 | 2′900 ± 760 | 3′200 ± 820 | 0.99 | |
| 139La | 0.04 | 0.18 | <LoD | 5 | 10 | 3.8 ± 0.4 | 4.1 ± 0.4 | 0.84 | 170 ± 50 | 180 ± 50 | 0.99 |
| 140Ce | 0.05 | 0.29 | 0.3 ± 0.2 | 4 | 9 | 14 ± 2 | 15 ± 2 | 0.87 | 420 ± 120 | 430 ± 110 | 0.99 |
| 141Pr | 0.01 | 0.06 | <LoD | 3 | 10 | 2.3 ± 0.3 | 2.5 ± 0.3 | 0.87 | 50 ± 10 | 50 ± 10 | 1.00 |
| 146Nd | 0.02 | 0.07 | 0.08 ± 0.03 | 5 | 13 | 13 ± 2 | 13 ± 1 | 0.89 | 200 ± 50 | 200 ± 60 | 0.99 |
| 147Sm | 0.02 | 0.01 | 0.02 ± 0.004 | 4 | 14 | 3.8 ± 0.4 | 3.6 ± 0.4 | 0.87 | 45 ± 12 | 45 ± 12 | 0.99 |
| 153Eu | 0.03 | 0.002 | 0.03 ± 0.01 | 9 | 16 | 1.1 ± 0.1 | 1.0 ± 0.1 | 0.75 | 11 ± 3 | 11 ± 3 | 1.00 |
| 172Yb | 0.03 | 0.01 | <LoD | 8 | 10 | 0.8 ± 0.1 | 0.9 ± 0.1 | 0.84 | 11 ± 3 | 12 ± 3 | 0.99 |
| 182W | 0.30 | 0.12 | 0.3 ± 0.2 | 9 | 17 | 1.4 ± 0.2 | 0.6 ± 0.1 | 0.08 | 6 ± 1 | 6 ± 1 | 0.98 |
| 205Tl | 0.15 | 0.18 | 0.8 ± 1.2 | 5 | 24 | 0.7 ± 0.1 | 0.7 ± 0.1 | 0.80 | 5.1 ± 0.8 | 4.6 ± 0.7 | 0.98 |
| 208Pb | 0.61 | 0.85 | 2.7 ± 1.3 | 12 | 17 | 24 ± 3 | 35 ± 3 | 0.82 | 690 ± 100 | 720 ± 110 | 0.99 |
| 209Bi | 0.03 | 0.16 | 0.2 ± 0.2 | 11 | 25 | 1.3 ± 0.2 | 1.1 ± 0.1 | 0.86 | 3.8 ± 0.7 | 3.5 ± 0.6 | 0.94 |
| 232Th | 0.04 | 0.05 | 0.04 ± 0.04 | 14 | 17 | 1.0 ± 0.1 | 0.8 ± 0.1 | 0.87 | 26 ± 7 | 24 ± 6 | 1.00 |
| 238U | 0.10 | 0.04 | <LoD | 8 | 14 | 0.6 ± 0.1 | 0.5 ± 0.1 | 0.79 | 14 ± 3 | 14 ± 3 | 0.98 |
| Elementa | SF-CN | SF-CG | TOF-CN | TOF-CG |
|---|---|---|---|---|
| 23Na | 370 ± 140 | 410 ± 150 | 2100 ± 1700 | <LoD |
| 27Al | 220 ± 40 | 430 ± 170 | 560 ± 150 | <LoD |
| 44Ca | 670 ± 130 | 2500 ± 1400 | 5100 ± 2700 | 1900 ± 1000 |
| 63Cu | 7 ± 2 | 15 ± 7 | 14 ± 9 | 33 ± 20 |
| 138Ba | 4 ± 1 | 4 ± 1 | 52 ± 7 | 55 ± 6 |
Procedural blanks are in the range of the LoDs or slightly higher for most TEs (Table 2). Exceptions are Na, Al, Ca, Cu, and Ba, which are all susceptible to contamination by sample handling, and thus can vary strongly between the different sampling days. The analytical precision (see Material and methods) achieved with the ICP-SF-MS is in the few percent range for most TEs, and on average almost a factor of two higher compared to the ICP-TOF-MS precision (7 ± 4% SF vs. 11 ± 6% TOF; Table 2). The ICP-TOF-MS precision is also lower by around a factor of two than values reported in the literature,37,38 likely since the latter were determined for higher concentration levels. As a general trend it is observed for both instruments, that the lower the concentration range, the lower the achieved analytical precision. This is more strongly pronounced for the analysis by ICP-TOF-MS (e.g., Ag, W, Tl, Bi). Also, for TEs prone to contamination and present at relatively low concentrations compared to the procedural blank, analytical precision was lower for both instruments (e.g., Zn, Pb). For Sc, the analytical precision was found to be about three times lower for the ICP-TOF-MS (15% compared to 5% for the ICP-SF-MS; see later discussion). The instrumental precision – assessed in this study using sequential triplet measurements (see Material and methods) which excludes effects from variability in daily calibration or from differences in ambient background conditions – was high for both instruments: 3 ± 1% for the ICP-TOF-MS and 6 ± 2% for the ICP-SF-MS on average, respectively (Table S1). A higher instrumental precision of the ICP-TOF-MS was observed for all TEs, with the sole exception of Sc (see later discussion). The analytical accuracy investigated for the certified TEs in the rainwater reference material (TMRAIN-04) was in the same range as the analytical precision for the respective instrument, generally again higher for the ICP-SF-MS compared to the ICP-TOF-MS (Table S2). Comparable to the analytical precision, also the level of accuracy largely reflects the TEs signal-to-noise ratio, i.e., its concentration in the reference water in relation to its susceptibility to contamination (typically reflected by a rather high method LoD). For example, illustrated if comparing Fe, Zn or Pb with U in Table S2.
In summary, excluding Sc and TEs with lower nominal masses than reported here, the results indicate that the instrumental performance of the ICP-TOF-MS is fully sufficient and equally suitable for TE analysis, compared to the traditionally used ICP-SF-MS, at least under the analytical methods and procedures applied in this study.
| Cerro Negro (n = 112) | Colle Gnifetti (n = 26) | |
|---|---|---|
| Comparability of temporal concentration variability with Pearson r analysis | ||
| TE (#) | r | TE (#) |
| a TEs with less than 25% of sample pairs having concentrations above the LoD. | ||
| Fe, Rb, Cs (3) | >0.9 | Na, Mg, Al, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Zr, Mo, Ag, Cd, Sb, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Yb, W, Tl, Pb, Bi, Th, U (35) |
| Mg, Al, V, Mn, Ni, Cu, Sr, Zr, Sb, La, Ce, Pr, Nd, Sm, Yb, Tl, Pb, Bi, Th (19) | >0.8–0.9 | |
| Sc, Co, Ba, Eu, U (5) | >0.7–0.8 | |
| Ag (1) | >0.6–0.7 | |
| Na, Ca, Cr, Mo, Zn, Cd, W (7) | <0.6 | |
For Sc, the average concentration obtained with the ICP-TOF-MS is more than a factor of three higher than the one from the ICP-SF-MS, while the variability along the ice core section is similar (r = 0.95). As illustrated in Fig. 5, the nominal mass resolution of the ICP-TOF-MS of m/Δm = 2′500–3′000 is not sufficient to fully resolve the 45Sc peak from the two interferences 29Si16O+ and 90Zr2+. For that a resolution of 2′902 and 12′628, respectively, would be required, or alternatively a suppression of them which has however shown to be particularly challenging.39 Across all samples and blanks, the intensity of the 29Si16O+ peak remained relatively stable, indicating that the quartz torch was the major source. However, because the concentrations of Zr and Si may vary from sample to sample – which is not the case for the calibration standards (and the CRM) – largely depending on the mineral dust content (e.g., for Colle Gnifetti from silicate minerals in Saharan dust deposits), peak fitting procedures did not allow for satisfying precision, resulting in a general overestimation of Sc concentrations with the ICP-TOF-MS. For 56Fe the mass resolution of the ICP-TOF-MS (m/Δm = 2′175) is nominally also not sufficient to separate the peak from the 40Ar16O interference, requiring m/Δm = 2′503. The reaction of 40Ar16O with H2 significantly decreases the intensity of 40Ar16O and thus minimizes the interference.40,41 In this case the interference could sufficiently be suppressed through meticulous adjustment, involving fine-tuning the collision gas flow in the collision/reaction cell, which is filled with a 7% H2 in He gas mixture. In addition, concentrations of Fe were about four orders of magnitude higher than concentrations of Sc, resulting in a better peak fitting.
For the Cerro Negro samples, TE concentrations obtained with ICP-TOF-MS and ICP-SF-MS are generally in good agreement, however, larger differences are observed for some TEs compared to the Colle Gnifetti samples. As will be discussed in more detail below, this can largely be attributed to the generally lower concentrations and potentially also to a less precise depth alignment of the parallel samples for this core. To reduce the impact of the latter in the evaluation of instrument comparability, a 3-point moving average was applied. The effect is illustrated for Al in Fig. S2. Average concentrations obtained with ICP-TOF-MS and ICP-SF-MS are in good agreement for 25 of 35 TEs (p > 0.05); see Fig. 3 and Table 3. For four of the TEs (Sc, Zn, Cd, W), less than 25% of the sample pairs showed concentrations above the LoD – Sc due to the high LoD caused by the interferences in the TOF-MS as discussed before – and these TEs will therefore not be discussed further. Of the 25 TEs with agreement in the average concentrations, 22 also show a similar concentration variability along the ice core section as indicated by correlation coefficients r > 0.7–0.9 (see e.g., Al and Rb concentrations in Fig. 6). Rb concentrations are in the low ng L−1 range, but still well above the LoDs and the procedural blank. For the remaining three of these 25 TEs, the correlation coefficient r is lower than 0.6 (Na, Cr, Mo; Table 3). In contrast to Rb, Na concentrations in the samples from Cerro Negro are frequently close to the LoD. Na is further susceptible to contamination, reflected in variations of procedural blanks between the different cutting sessions, likewise observed for Al, Ca, Cu, and Ba. For blank correction of these TEs, individual blanks for each day were accordingly used (Table 2). Generally, our results suggest that for TEs with ice sample and procedural blank (and/or LoD) concentration levels being in the same order of magnitude, as it is the case e.g., for Na, Cr and Mo, any observed discrepancies between ICP-TOF- and ICP-SF-MS should be attributed to the procedure rather than to differences in instrumental performance. In Fig. 6, this is illustrated on the example of the Na concentration record, which mostly varies within the range of the procedural blank concentrations. It becomes even more evident in the Bland–Altman plot (Fig. 7), showing that Na concentrations of most Cerro Negro samples are close to or even below the LoD (51% of sample pairs). As expected, these low concentration samples clearly show the largest relative concentration difference in measurements from the two instruments. For comparison, Fig. 7 includes a similar plot for Cs, for which concentrations in both cores are comparable and above the LoD for all samples. Some TEs like Na, Mg, Ca, or Ba, mostly present in water-soluble minerals, are prone to be relocated in glaciers affected by melt processes such as Cerro Negro.9 This might induce inhomogeneities between the parallel samples analysed by ICP-TOF-MS and ICP-SF-MS, respectively, additionally contributing to the reduced inter-instrument agreement for the samples from this site compared to those from Colle Gnifetti.
No agreement in the averages was observed for six of the TEs: Ca, Mg, Sr, Ag, Ba, and Pb (Table 3). However, for Mg, Sr, Ba, and Pb with concentrations above the LoD for ∼80% of sample pairs, relatively high correlation coefficients of r > 0.7 were still observed. The finding that ICP-TOF-MS averages are higher than ICP-SF-MS averages for most TEs (and for both cores), suggests that contamination control in the ICP-TOF-MS lab for discrete sampling was not optimal, particularly for the lower concentration range of the Cerro Negro ice core samples. This is not unexpected, as this lab is not fully equipped for manual decontamination under clean-room conditions, but was designed for CFA, which avoids any exposure of the melt fraction of the ice core samples from contact with the lab environment19. For Ag, the precision of the analysis is generally low for both instruments since concentrations are close to the LoDs.
For the ice core section with generally higher TE concentrations (Colle Gnifetti), average concentrations obtained with ICP-TOF-MS and ICP-SF-MS are in exceptional correspondence for all TEs (p > 0.05; except for Sc for reasons mentioned above). The agreement in the concentration variability along the ice core section is also excellent for all TEs as indicated by high correlation coefficients (r > 0.9).
For the ice core section with generally lower concentrations (Cerro Negro), average TE concentrations obtained with ICP-TOF-MS and ICP-SF-MS are generally also in good agreement, however, larger relative differences were observed for some TEs compared to the Colle Gnifetti samples. Larger differences were observed for TEs which are prone to contamination, especially if procedural blanks were challenging to control and varied over time (e.g., Ba, Ca, Na). Because some TEs are also prone to be relocated in glaciers affected by melt like Cerro Negro, induced inhomogeneities between the parallel samples (in addition to a generally reduced precision in the depth alignment of samples from this core) may have further contributed to the observed differences between the two instruments. With concentrations in the samples from Cerro Negro close to the concentration levels of the procedural blanks or even the limit of detection for many of the TEs, larger relative discrepancies were also observed for e.g., Ag, Cd, Cr, Mo, Pb, W, Zn. Low concentrations, associated with a reduction in analytical precision and a higher relative contribution from the procedural blank are thus rather responsible for the observed discrepancies between the results obtained with the two instruments than differences in their performance.
In summary, the performance of the new ICP-TOF-MS to determine concentrations of TEs in ice core samples was found to be excellent for the investigated trace elements within a nominal mass range from 23 to 238. Except for interferences on the 45Sc mass, which could not be resolved by the resolution of the instrument or sufficiently be suppressed in the collision/reaction cell of the TOF. For most applications in ice core research this is acceptable, especially when considering the great benefit to analyze single particles in the same sample.
For data presented in this article and its accompanying SI that are not provided in the tables, see: Mendeley Data at https://doi.org/10.17632/6th6y85gxt.1.
| This journal is © The Royal Society of Chemistry 2025 |