Open Access Article
Rocio Aranda-Rodriguez
*a,
Ariadne Piperakis†
a,
William Papas‡
a,
Emma Fantin§
a and
Paul A. Whiteb
aExposure and Biomonitoring Division, Environmental Health Science and Research Bureau, Health Canada, 251 Sir Frederick Banting Driveway, Ottawa, ON, Canada. E-mail: rocio.aranda-rodriguez@hc-sc.gc.ca
bMechanistic Studies Division, Environmental Health Science and Research Bureau, Health Canada, 251 Sir Frederick Banting Driveway, Ottawa, ON, Canada
First published on 20th October 2025
Firefighters are increasingly concerned about their exposure to per- and polyfluoroalkyl substances (PFAS). Polymeric PFAS are commonly used in the manufacturing and treatment of textiles designed for firefighters' turnout gear. This study was conducted to assess the effect of wear and tear on the concentrations and distribution of PFAS in used turnout gear by analyzing swatches taken from different areas from the different layers of the gear: the outer layer (OL), moisture barrier (MB), and thermal liner (TL). In the OL, samples collected from the bottom back of the pants showed higher concentrations of perfluoroalkyl acids (PFAAs) than samples taken from the knee, ankle, and groin areas. In the jacket, samples from the neck of the OL exhibited lower PFAA concentrations compared to samples taken from the back, elbow, and underarm areas. In addition, this study assessed PFAS profiles in the layers of five firefighter jackets (J) and four pants (P) manufactured between 2008 and 2019. The jacket manufactured in 2019, which had been in service for only one year, recorded the lowest PFAS concentration at 284 ng g−1. Notably, fluorotelomer alcohols (FTOHs, including n = 6, 8, 10) were detected in all samples, accounting for over 50% of the total PFAS content. Generally, perfluorooctane sulfonate (PFOS) was found in older jackets, while perfluorobutane sulfonate (PFBS) was detected in newer jackets. Interestingly, the highest concentrations of FTOHs in the MB occurred in unused gear (DOM 2011), and these concentrations increased over time since manufacture, with the lowest levels found in newer and lightly used gear (DOM 2019). Moreover, the thermal liner from the unused gear had the lowest PFAS concentration.
Environmental significanceNonpolymeric PFAS, including fluorotelomer alcohols and polyfluoroalkyl acids, are undeniably released from textiles treated with side-chain fluorinated polymers (SCF). Furthermore, nonpolymeric PFAS have been found in textiles made from expanded polytetrafluoroethylene (ePTFE), a highly stable fluoropolymer resistant to degradation. It is essential to note that it remains unclear whether ePFTE layers have also undergone treatment with SCF. The concentration and profiles of PFAS in various functional textiles are influenced by critical factors such as the year of manufacture, the duration of use, and the extent of wear and tear. Textiles treated with SCF or containing ePTFE are not restricted to firefighter gear; they are widely used in outdoor gear designed for the general public. The presence of fluorotelomer alcohols may impact dermal and inhalation exposure and their release to the indoor air. |
PFAS have been defined as fluorinated substances containing at least one fully fluorinated methyl or methylene carbon atom.11 They can be classified into two major groups: polymeric PFAS and nonpolymeric PFAS.12 Polymeric PFAS, such as fluoropolymers, are considered very stable and difficult to degrade; however, processing aids and residual reactants, including monomers, oligomers, and both aqueous and volatile residues, can be released into the environment at various stages of the fluoropolymer life cycle.13,14 To date, regulatory efforts have primarily focused on the nonpolymeric PFAS, specifically the perfluoroalkyl acids (PFAAs) such as PFOA and PFOS, which have been classified as a human carcinogen and a possible human carcinogen, respectively.15
PFAS are ubiquitous in the environment and have been detected in various consumer products, including food packaging materials, personal care products, textiles, and construction materials.16,17 Whilst the general population may be exposed to PFAS daily, biomonitoring studies indicate that concentrations of PFHxS, PFOS, PFOA, and PFNA are significantly higher in the serum or plasma of firefighters compared to the general population.18 This suggest that firefighters may experience greater exposure to PFAS due to their occupation.
Firefighter turnout gear has been recognized as a potential source of PFAS exposure for firefighters for over a decade, primarily due to contamination from the use of AFFF.19 The jackets and pants in turnout gear are designed to meet specific thermal, physical, chemical, and biological protection requirements.20,21 Consequently, they are constructed with three functional layers: the outer layer (OL), moisture barrier (MB), and thermal liner (TL). Some of these layers contain or are treated with PFAS products to enhance textile strength, durability, and water and oil repellency. The outer layer (OL) serves as the gear's external facing layer, providing cut and abrasion resistance, water repellency, and thermal protection. The OL is primarily made from aramid-based fabric treated using durable water and oil-repellent (DWR) applications that typically employ side-chain fluorinated polymers (SCFPs).22 A study by Peaslee et al. (2020)8 reported the presence of nonvolatile PFAS in every layer of firefighter jackets. They also noted a 27% decrease in fluorine content in the OL due to wear and tear of the protective coatings with usage and age. In a study conducted by Muensterman et al. (2022),9 the levels of PFAS, including both volatile and nonvolatile PFAS, were measured in the OL from new, unused firefighter jackets. The concentrations ranged from 116 ng g−1 to 3100 ng g−1. In contrast, a separate study by Maizel et al. (2023)10 reported total PFAS levels in the textiles used for the OL before the jackets were manufactured, with concentration ranging from 630 ng g−1 to 1890 ng g−1.
The middle layer, known as the moisture barrier (MB), protects against liquid intrusion while allowing perspiration to escape. Unlike the OL, the MB is not a single fabric; instead, it consists of an aramid membrane laminated onto a woven fabric and then laminated to a fluoropolymer such as expanded polytetrafluoroethylene film (ePTFE). Currently, MBs containing ePTFE are in use, while manufacturers are developing alternatives that meet established testing requirements.21 Reportedly the MB has the highest total fluorine concentrations (120
000 mg F per kg).9 PFAS levels, both volatile and nonvolatiles, ranged from 225 to 1380 ng g−1 (ref. 9) in the MB of new jackets. The dermal-facing layer, known as the thermal liner (TL), provides most of the garment's thermal protection. TLs are composed of a face cloth laminated onto aramid or meta-aramid batting. PFAS have also been detected in the TL textiles prior to turnout gear manufacturing (0.2 to 5.7 ng g−1) and in the TL of new jackets (5 ng g−1 to 156 ng g−1),10 even though most manufacturers do not include PFAS in their production specifications.
Additional sources of PFAS in the firefighters' occupational environment include dust samples from fire stations. In North America, fire stations' dust samples consistently showed higher levels of 6
:
2 diPAP, PFOA, PFNA, PFHxS, and PFOS compared to dust samples from residential homes.23 Moreover, higher levels of PFOS have been found during fire suppression activities,24 particularly when fluorinated AFFF is used.25 Therefore, research is needed to evaluate dermal and inhalation exposures to better understand the long-term occupational risks associated with PFAS.23,26
PFAS-containing gear may be subjected to elevated heat, sweat, and other environmental factors for up to ten years before mandatory retirement. Studies indicate that aging of textiles treated with DWR result in higher concentrations of extractable PFAAs compared to those that have not been aged.27 Additionally, weathering of DWR-outdoor clothing showed a significant increase in the concentrations of volatile PFAS – by five to 100 times – and nonvolatile PFAS – by 20 times28 compared to non-weathered samples. Importantly, washing and tumble drying DWR fabrics decreases the extractable PFAA and FTOH concentrations compared to the textiles that have not been aged.27 Notably, PFAAs were not detected in clothing before weathering, indicating a transformation of PFAS over time.29 Schellenberger et al.30,31 highlighted that increased exposure to sunlight, heat, and wind contributes to the release of nonpolymeric PFAS from rain jackets and the transformation of PFAA precursors. Thus, use, aging, and weathering can significantly influence the concentration and profile of PFAS present in turnout gear throughout the garment's lifespan.
This study investigated how PFAS concentrations vary across different areas of the same garment, as wear and tear in specific areas—such as the chest and the lower back of the jacket—may significantly contribute to the release of PFAS due to the effects of sweat and abrasion. Additionally, this study systematically examined how gear usage influences PFAS profiles across each of the three layers of firefighter turnout gear. This study presents a thorough analysis of four critical trends in the PFAS content of firefighter turnout gear: trends by layer, trends by location, trends in garment usage, and trends in compound classes.
:
2 FTOHs, n = 4, 6, 8, 10), and perfluoroalkane sulfonamido ethanols (Me-FOSE and Et-FOSE), as well as nonvolatile PFAS such as perfluoroalkyl carboxylic acids (C4–C14 PFCAs), perfluoroalkane sulfonic acids (C4–C9 PFSAs), fluorotelomer sulfonic acids (n
:
2 FTS n = 4, 6, 8), perfluoroalkane sulfonamides (FASAs) and pefluoroalkane sufonamido acetic acids (FASAAs). All native PFAS standards and mass-labelled PFAS internal standards were purchased from Wellington Laboratories (Guelph, ON, Canada). OmniSolv grade ethyl acetate and ENVI-Carb were purchased from Sigma-Aldrich (Oakville, ON, Canada). Optima-grade methanol and water were purchased from Fisher Scientific (Ottawa, ON, Canada).
To evaluate trends in fabric layers and locations, one set of used turnout gear (jacket and pants), previously worn by the same individual, was selected. Fabric swatches (2 cm × 2 cm) were cut in duplicate from various areas within the jacket (the neck, chest, elbow, and back) and the pants (groin area, bottom back, knee, and ankle). Samples were taken from both the left and right sides, and from their respective fabric layers (i.e., TL, MB, and OL), therefore 4 replicates were obtained from each location, resulting in 32 samples per layer, except in the OL where the collar was double-layer, hence a total of 36 samples were collected in the jacket's OL.
:
2 FTOH, and 6
:
2 FTOHs were not detected in any samples. In contrast, 8
:
2 FTOH and 10
:
2 FTOH were detected in all samples across all layers, with median concentrations ranging from 33 ng g−1 to 926 ng g−1 (Table 1). These levels were one to two orders of magnitude higher than those of individual PFCAs and PFSAs, respectively. Perfluoroalkyl carboxylic acids (PFCAs) were the second-most prominent group detected, with C8–C14 PFCAs present in all MB samples, showing concentrations between 5.2 ng g−1 and 56 ng g−1. In the OL, only C8, 10, 11, 12, and 14, PFCAs were consistently detected in the OL with median concentrations ranging from 2.3 ng g−1 to 11 ng g−1. For the TL, C8, 10, 12, and 14 PFCAs were detected in 59% to 97% of the samples, with median concentration between 0.81 ng g−1 and 1.7 ng g−1. Regarding PFSAs, PFOS was detected in MB and OL samples, but not in those from the TL. The concentration of FTSs and FASAs, less than 4 ng g−1, was three orders of magnitude lower than FTOHs and one lower than the median concentration of PFCAs for their corresponding layers. FBSA was undetected in the OL layer but found in 91% of the MB samples and 22% of the TL samples. Additionally, 8
:
2 FTS was detected in 88% of the MB samples (Table 1). The most notable trend was that the concentrations of PFAS in the MB samples were significantly higher than those in the OL and TL, following the order: MB > OL > TL. This trend was consistent across various PFAS grouping (see Table S1 for grouping information), including volatile PFAS, nonvolatile PFAS, PFAAs, PFAA precursors, FTOHs, and PFCAs (p < 0.001) (see Fig. 1a). A similar trend has been reported in other studies involving used jackets.9 However, new textiles showed higher concentrations of PFAS in the OL compared to MB.9,10 In this study, concentrations of FTSs and PFSA were significantly higher in the MB compared to the OL and TL; with no significant difference between the OL and TL (MB > OL = TL). Perfluorobutane sulfonamide (FBSA) was the only FASA detected, found in both the MB and TL (MB > TL), but it was undetected in the OL. This may suggest a shift in industry practices away from using PFOS and towards using PFBS and other shorter-chain PFAS such as FBSA. Chu and Letcher (2014)34 identified N-ethyl perfluorooctane sulfonyl chemical moiety in fabric protector formulations produced before 2002, with FOSA identified as the primary metabolite of liver microsomes. In contrast, the perfluorobutanesulfonyl chemical moiety was found in fabric protectors manufactured after 2002, with FBSA identified as the primary metabolite of liver microsomes.
| Compound | TL | MB | OL | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ng g−1 | ng g−1 | ng g−1 | ||||||||||
| DF | Median | Min. | Max. | DF | Median | Min. | Max. | DF | Median | Min. | Max. | |
8 : 2 FTOH |
100% | 110 | 58 | 260 | 100% | 685 | 343 | 941 | 100% | 379 | 205 | 815 |
10 : 2 FTOH |
100% | 67 | 33 | 156 | 100% | 926 | 340 | 1263 | 100% | 155 | 82 | 322 |
| PFBA | 22% | 0.36 | 0.26 | 2.5 | 16% | 0.2 | <MDL | 2.0 | 81% | 0.66 | 0.22 | 3.6 |
| PFPeA | 0% | <MDL | 50% | 0.40 | 0.05 | 2.8 | 22% | 0.24 | 0.15 | 0.81 | ||
| PFHxA | 6% | <MDL | 69% | 0.81 | 0.12 | 2.8 | 17% | 0.66 | 0.26 | 2.4 | ||
| PFOA | 59% | 0.81 | 0.53 | 9.9 | 100% | 5.2 | 1.3 | 15 | 100% | 2.3 | 0.89 | 8.7 |
| PFNA | 22% | 0.76 | 0.26 | 25 | 100% | 4.0 | 1.1 | 13 | 67% | 11 | 0.1 | 69 |
| PFDA | 81% | 1.7 | 0.49 | 5.0 | 100% | 39 | 11 | 78 | 100% | 4.0 | 1.9 | 11 |
| PFUdA | 34% | 1.6 | 0.48 | 9.5 | 100% | 14 | 6.2 | 34 | 100% | 14 | 4.5 | 65 |
| PFDoA | 97% | 1.8 | 0.6 | 5.5 | 100% | 56 | 11 | 109 | 100% | 9.5 | 2.6 | 21 |
| PFTrDA | 13% | 0.6 | <MDL | 1.5 | 100% | 5.3 | 1.8 | 13 | 50% | 1.0 | 0.1 | 2.8 |
| PFTeDA | 91% | 1.4 | 0.5 | 3.5 | 100% | 29 | 4.2 | 60 | 100% | 3.6 | 1.3 | 9.6 |
| PFBS | 59% | 0.68 | 0.46 | 2.3 | 50% | 0.42 | 0.13 | 2.1 | 22% | 0.45 | 0.31 | 0.94 |
| PFOS | 0% | <MDL | 97% | 3.6 | 0.2 | 7.6 | 69% | 1.4 | 0.24 | 8.5 | ||
| FBSA | 22% | 0.61 | 0.50 | 1.4 | 91% | 1.1 | 0.15 | 2.4 | 0% | <MDL | ||
6 : 2 FTSA |
14% | <MDL | 38% | 0.33 | 0.12 | 5.4 | 25% | 0.55 | 0.38 | 3.5 | ||
8 : 2 FTSA |
31% | 1.7 | 1.4 | 3.3 | 88% | 3.6 | 0.4 | 7.4 | 17% | 1.1 | 0.6 | 5.1 |
While layer trends can offer insights into PFAS profiles within each layer, it is important to note that turnout gear fabrics are subjected to up to ten years of chemical exposures, physical stress, heat, sweat and laundering cycles. Since nonpolymeric PFAS can be emitted from functional textiles during washing31 and weathering,30 we hypothesized that different parts of the jacket and pants, which can undergo varying exposures to heat or abrasion, would show different PFAS profiles. Statistical analyses assessed (a) differences between the jacket and the pants within layers and (b) the differences between locations within the jacket and pants in each layer. In this study, there were no statistically significant differences in the concentration of PFAAs precursor (mainly FTOH) between the jacket and pants for each layer. In addition, there were no significant differences in concentration of PFAAs between the MB of the jacket and the pants. However, the jacket's OL and TL had higher PFAA concentrations than those in the pants' OL and TL (p < 0.05). Additionally, the jacket also had a higher concentration of nonvolatile PFAS in the TL (p < 0.03).
When examining the differences between locations in both the jacket and pants within each layer (MB, OL, and TL), significant differences in the levels of PFAAs and their precursors were observed. For example, the OL samples from the back bottom of the pants showed higher PFAA concentrations compared to those from the ankle, groin, and knee areas (p < 0.05) (Fig. S1a). It was anticipated that both the back bottom and knee areas would exhibit higher concentration than the groin and ankle, as other studies noted that PFAS concentration increased 2–3-fold in DWR-treated OL following abrasion in an experimental setting.35 Our findings were consistent with those of Peaslee et al. (2020),8 who discovered that the OL from used turnout gear lost 27% of its surface fluorine compared to the OL of unused gear. Regarding the jacket, OL samples from the neck had lower PFAAs concentrations compared to those from the back, elbow, and armpit areas (p < 0.01). This may suggest that the neck area endures less abrasion that other parts of the jacket. Since the neck area is composed of a double-outer layer, both layers were compared. The inner neck (the one facing the skin) had higher concentrations of PFAAs (p < 0.003), PFCAs (p < 0.003), PFSAs (p < 0.006) and nonvolatile compounds (p < 0.003) (Fig. S2) than the outer neck layer of the outer layer.
The concentrations of PFAAs and their precursor were notably lower in the neck area of the MB compared to the back, elbow, and armpit (p < 0.006, Fig. 3a and p < 0.003 respectively). In the pants, samples from the ankle and groin samples of the MB had lower PFAAs concentrations than those samples from back bottom, and knee (p < 0.003; see Fig. S3b). Additionally, the ankle exhibited lower levels of volatile and PFAA precursors than other locations (p < 0.01). Maizel et al. (2023)35 reported increased 6
:
2 FTMAC and 6
:
2 FTOH concentrations in abraded MB and DWR-OL fabrics. Although 6
:
2 FTMAC was not included in this study, 8
:
2 FTOH and 10
:
2 FTOHs were higher in the back bottom and the knee areas, suggesting that these sections of the pants may experience higher abrasion than others. For TL, the neck and underarm samples showed significantly higher PFAA concentrations compared to the elbow, chest, and back (p < 0.03; see Fig. S4). In another study, a 16-fold increase in PFAS was observed in abraded TL textiles, primarily due to higher PFCA concentration.35 However, low abrasion was expected in both neck and underarm areas, and it remains unclear whether this is related to the accumulation of sweat and oils in those regions.
:
2 FTOH, 8
:
2 FTOH, and 10
:
2 FTOH (Fig. 2 and Table S6). In the unused gear (J1 and P1, DOM 2011), 59% of the total PFAS content was attributed to FTOHs, while PFCAs accounted for 16% to 22%. Notably, volatile PFAS (mainly FTOHs) were one order of magnitude higher than nonvolatile PFAS. In J1 and P1, concentrations of 8
:
2 and 10
:
2 FTOHS were also one order of magnitude higher than 6
:
2 FTOH (Table S6). Perfluoroalkane sulfonamido ethanols (FASEs) were detected in the OL of this unused gear (see Fig. 2 and Table S6). PFOS was the only PFSA detected in the OL of the unused J1 with a concentration of 1.1 ng g−1 (Table S8). The findings for the OL of the unused turnout gear align with those reported by Muensterman et al. (2022):9 higher levels of 8
:
2 FTOH, 10
:
2 FTOH, MeFOSE, EtFOSE, 8
:
2 FTAc, and 10
:
2 FTAc were observed for unused gear manufactured in 2008. In contrast, only FTMAc and 6
:
2 FTOHs were detected in unused turnout gear manufactured in 2019. It is important to note that FTAc and FTMAc were not included in the present study however, they can account for up to 40% of the total volatile concentration. This highlights the importance of including them in the volatile analysis (Fig. S5a).
![]() | ||
| Fig. 2 Individual PFAS concentrations (ng g−1) in the turnout gear jackets (J1–J5) and pants (P1–P4). Includes unused turnout gear (J1/P1, framed in red) and used turnout gear (J2–J5 and P2–P4). | ||
The total concentrations and profiles of PFAS varied significantly depending on the age of the turnout gear. The total concentration of PFAS in the OL in the set J2 and P2 (DOM 2008) were 573 ng g−1 and 550 ng g−1, respectively. FTOHs accounted for 89 and 92% of the total PFAS in J2 and P2, respectively, while the rest was attributed to PFCAs. Jackets J3 (DOM 2009) and J4 (DOM 2010) had the highest total PFAS concentrations, measuring 1790 ng g−1 and 2000 ng g−1, respectively, but showed different PFAS distributions. In J3, PFCAs comprised 73% of the total PFAS, while FTOHs only contributed 25%. In contrast, in J4 (DOM 2010), FTOHs constituted 60% of the total PFAS, with PFCAs accounting for 28%. Additionally, FASEs, FTS, and PFSA contributions were consistent in J4 (between 3% and 5%). It was reported that J4 and P4 were used for training exercises and may have been exposed to dry chemical powder and firefighting foam, which is further supported by similar observations in both turnout gear which were obtained from the same source. AFFF typically contains 2–3% fluorocarbon surfactants, such as polyfluorinated alkyl polyamides, quaternary amines, and perfluoroalkyl sulfonate salts.25 Interestingly, PFAAs, PFSAs, FTOHs, FTS, FASAs, and FASAAs have been reported in different AFFF formulations.36 The PFCAs profile in the turnout gear manufactured in 2008–2010 was dominated by C8, C10, C12, and C14 (Fig. 2 and Table S7), likely due to the weathering of C8-F17-SFP DWR coating.30 In older jackets, PFOS was the predominant PFSAs detected, whereas PFBS was the only PFSA found in the newer jacket (J5). The jacket used for one year (J5) showed the lowest concentration of total PFAS at 284 ng g−1, with 6
:
2 FTOH representing one-third of this amount, alongside smaller contributions from 8
:
2 FTOH and 10
:
2 FTOH. In this jacket, only C4, 6, 9, 11, and 13 PFCAs were detected (<60 ng g−1). FTSs such as 6
:
2 FTS and 8
:
2 FTS were detected mainly in jackets J4 and J5 and pants P3 and P4, corresponding to turnout gear manufactured in 2010 or later. FTSs are considered transient degradation intermediates of the FTOHs, suggesting that their presence in newer gear may indicate incomplete weathering of FTOHs.27,37 Overall, analysis revealed that levels of 8
:
2 FTOH and 10
:
2 FTOH were higher in older jackets (manufactured between 2008–2010) compared to a newer jacket (J5) (Table S6). Conversely, levels of 6
:
2 FTOH were higher in newer turnout gear (manufactured in 2013 and 2019) as opposed to the older gear. This variation in FTOH concentrations may indicate a shift from using C8-F17-SFP DWR coating to C6 raw products. Peaslee et al. (2020)8 found that used turnout gear lost 27% of its surface fluorine compared to unused gear. Similarly, Maizel et al. (2023)10 reported that there was an over 150% increase in extractable nonpolymeric PFAS in OL due to abrasion, exposure to elevated temperatures, and weathering. In contrast, laundering the gear resulted in a 25% decrease in the extractable total PFAS concentration.
:
2 FTOH, 10
:
2 FTOH, and 6
:
2 FTOH (Fig. 2), which collectively accounted for over 74% of total PFAS present, except in the samples from J3, J4 and P4. The highest concentrations and contribution of FTOHs were found in the unused jacket and pants, measuring 2375 ng g−1 and 2684 ng g−1, respectively. An interesting observation is that higher FTOH in the MB were obtained in older gear (Fig. 3a). Notably, J5, was manufactured in 2019 and used for only one year, contained the lowest concentration of FTOHs at 613 ng g−1 (Fig. 3a). Due to the small sample size in this study (n = 7 used and n = 2 unused), this trend must be verified. In samples from J3, J4 and P4, PFAAs contributed more to the total PFAS than FTOHs. The highest concentration of PFCAs was identified in J3 at 2800 ng g−1, corresponding to C8, 10, 12, and 14 PFCAs. Additionally, the concentration of FTSs and PFSAs were notably higher in P4, primarily due to the levels of PFOS and 6
:
2 FTS. P4 exhibited a distinct PFAS profile compared to the rest of the turnout gear and showed similarities to the OL from the same pants (P4), with FTS and PFCA contributing 26% and 10%, respectively, to the total PFAS. There was no correlation between the concentration of nonvolatile PFAS and the years since the turnout gear was manufactured (Fig. 3a). Peaslee et al.8 reported a high concentration of PFBS (47
900 ng g−1) in unused pants (DOM, 2014) based on a basic methanolic extraction. Muensterman et al. (2022)9 suggested that this type of extraction could degrade polymeric PFAS; however, basic methanolic extraction was not performed in this study. FASAs are raw materials for fluorochemical products, including those used for surface protection products,12 and their presence in unused jacket and pants may indicate impurities.
Muensterman et al. (2022)9 reported concentrations of 8
:
2 FTOH and 10
:
2 FTOH in the MB of an unused jacket at 491 ng g−1 and 288 ng g−1, respectively. The presence of FTOH in the MB suggests that side-chain fluoropolymers may have been added to the sublayers.9,10 However, this observation does not explain the high concentration of FTOH in the MB compared to the OL. El Aidani et al. (2013)38 found morphological alterations to e-PTFE/Nomex during photoaging and the formation of low molecular weight molecules containing carbonyl group (C
) and carboxylic acid groups (–COOH). Nevertheless, other degradation mechanisms remain unidentified, and it is unlikely that MB textiles in the turnout gear are exposed to UV rays from sunlight. It is still unclear whether ePFTE degrades over time during storage, however it is of a significant importance as fluoropolymers are considered chemically stable. Furthermore, it has been suggested that PFAS in the MB migrates to the TL.
000 ng g−1. In contrast, Muensterman et al. (2022)9 found PFAS concentrations (both volatile and nonvolatile) in TL ranging from 1.5 to 140 ng g−1. The higher concentrations of PFAS in used TL may be due to migration between layers, particularly during laundering. Since the MB and TL are attached and cannot be washed separately, PFAS may be transported from the PFAS-rich MB to the TL. The most recent study conducted by Maizel et al. (2023)10 demonstrated that PFAS can be washed out during laundering; however, each layer was treated separately in their research. In this study, there was no correlation between the total concentration of FTOHs, PFCA, and PFSAs between the MB and the TL. However, when the contributions of each group to the totals is compared between MB and the TL, good correlation coefficients were observed: percentage of FTOH (r2 = 0.59) and PFSAs (r2 = 0.93).The mechanism by which firefighters are exposed to PFAS from PFAS-containing turnout gear remains an area of ongoing research. Many studies have quantified extractable PFAS, with concentrations varying based on the solvent used. For instance, Peaslee et al. (2020)8 reported high concentrations of PFAS after a base-assisted extraction (2.0 M NaOH solution) and a methanol extraction. However, such extraction may lead to the degradation of polymeric PFAS, resulting in higher concentrations of PFAAs. While this and others studies have used methanolic extraction, Maizel et al. (2023)10 suggested that the base-assisted extraction may better indicate the amount of PFAS that can be released during the garment's lifetime. In contrast, methanolic extraction may only reflects the concentration of PFAS available at the time of the extraction. However, neither extraction fully reflects the PPE wearer's exposure to PFAS, highlighting the potential value of more standardized analysis of textiles.
While several different firefighter departments are currently adopting PFAS-free turnout gear, the transition will take time. In the meantime, understanding the potential retention of PFAS profiles in existing gear, and describing the types of PFAS involved can support developing best practices to reduce PFAS exposure.
Footnotes |
| † Current address: Faculty of Applied Science and Engineering, University of Toronto, West George St., Toronto, Ontario, M5S 1A4, Canada. |
| ‡ Current address: Department of Pharmacology and Toxicology, University of Toronto, 777 Bay Street, Toronto, Ontario, M5G 2C8, Canada. |
| § Current address: Department of Chemical Engineering, McGill University, Montreal, Quebec, Canada. |
| This journal is © The Royal Society of Chemistry 2025 |