Covalent organic framework-MnO2 nanoparticle composites for shape-selective sensing of bithiols

Yuping Cao a, Jin Zhanga, Jilu Yanga and Wenwu Qin*ab
aKey Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Special Function Materials and Structure Design (MOE), College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, P. R. China. E-mail: qinww@lzu.edu.cn; Fax: +86-931-8912582
bAcademy of Plateau Science and Sustainability, People’s Government Of Qinghai Province & Beijing Normal University, Xining, 810016, China

Received 8th March 2023 , Accepted 3rd May 2023

First published on 16th May 2023


Abstract

Covalent organic frameworks (COFs) for detecting biological macromolecules in water or biological environments are generally challenging. In this work, a composite material IEP-MnO2 is obtained by combining manganese dioxide (MnO2) nanocrystals and a fluorescent COF (IEP), which is synthesized by using 2,4,6-tris(4-aminophenyl)-s-triazine and 2,5-dimethoxyterephthalaldehyde. By the addition of biothiols, such as glutathione, cysteine or homocysteine with different sizes, the fluorescence emission spectra of IEP-MnO2 changed (“turn-on” or “turn-off”) via different mechanisms. The fluorescence emission of IEP-MnO2 increased in the presence of GSH by the elimination of the FRET (Förster resonance energy transfer) effect between MnO2 and IEP. Surprisingly, due to the formation of a hydrogen bond between Cys/Hcy and IEP, the fluorescence quenching for IEP-MnO2 + Cys/Hcy may be explained via the photoelectron transfer (PET) process, which endows IEP-MnO2 with specificity in distinguishing the detection of GSH and Cys/Hcy compared to other MnO2 complex materials. Therefore, IEP-MnO2 was used to detect GSH and Cys in human whole blood and serum, respectively. The limit of detection for GSH in whole blood and Cys in human serum was calculated to be 25.58 μM and 4.43 μM, which indicates that IEP-MnO2 can be used to investigate some diseases related to GSH and Cys concentration. Moreover, the research expands the application of covalent organic frameworks in the fluorescence sensing field.


1 Introduction

Biothiols, such as glutathione (GSH), cysteine (Cys), and homocysteine (Hcy), play a vital role in human physiology and pathology.1,2 Changes in these thiol levels are associated with many diseases, such as autoimmune diseases, cancer, diabetes, aging, cataracts, rheumatoid arthritis, and cardiovascular and neurodegenerative diseases (Alzheimer's disease).3–6 In the past few decades, many detection techniques have been developed for monitoring the concentration of biothiols, such as fluorescence spectroscopy,7 electrochemical pulse voltammetry,8 high-performance liquid chromatography,9 and colorimetry,.10 Due to its high sensitivity, easy operation, and low sample damage fluorescence spectroscopy stands out among many methods.11

In 2015, Li et al.12 and our group11 reported that MnO2 nanosheets were compounded with carbon quantum dots and phenolic resin, to detect GSH in liquid systems. In 2016, Du et al.13 synthesized graphene quantum dot-MnO2 nanosheets for the detection of GSH in solution systems and MCF-7 cells. Furthermore, in 2017, the Dong group2 combined MnO2 with high fluorescence scopoletin and also applied it to detect GSH. These studies provided ideas for designing “turn on” GSH sensors. However, most of these composite materials only rely on the redox reaction of GSH and MnO2, and they are not very outstanding in distinguishing the other similar thiols, such as Cys and Hcy.

Covalent organic frameworks (COFs) are a crystalline macromolecule composed of light elements with precise skeleton periodicity and presettable structures.14–16 Owing to their light weight, excellent porosity and highly accessible surface area, COFs have been significantly developed in gas storage and catalysis.17 Recently, some fluorescent COFs have attracted great interest in chemical sensing, solid-state light-emitting devices, photocatalysis, and optoelectronics. Currently, many COFs have been developed for fluorescent sensing, such as detecting metal ions,18–22 anions,23 nitrobenzenes,24–27 solvents,17 volatile organic compounds,28 etc. However, most COFs are used in organic solvents because water molecules will quench their fluorescence through hydrolysis of borate ester or forming hydrogen bonds with imine bonds on the COF skeleton. Thus, it is still a great challenge to use COFs for detection in the biological environment. Though some fluorescent COFs have been developed to detect bio-molecules present in organisms,29–31 it seems very interesting research to use covalent organic frameworks with adjustable pore sizes to discriminate molecules with similar properties but different sizes.

Here, we synthesized a fluorescent COF (IEP), by using 2,4,6-tris(4-aminophenyl)-s-triazine and 2,5-dimethoxyterephthalaldehyde, with a maximum emission wavelength of 523 nm under excitation at 406 nm. Then manganese dioxide (MnO2) nanocrystals were loaded on IEP through electrostatic interaction to form an IEP-MnO2 composite. The maximum emission of the IEP-MnO2 did not change while the fluorescence intensity decreased significantly. IEP-MnO2 was used for detecting GSH and Cys in human whole blood and serum, respectively. The experimental part is shown in the ESI and the synthesis process of IEP-MnO2 is shown in Scheme 1.


image file: d3ra01540h-s1.tif
Scheme 1 Synthesis of IEP and the IEP-MnO2 composite.

2 Results and discussion

2.1 Characterization of IEP

IEP was synthesized by the previously reported method.32 The Fourier transform infrared (FT-IR) spectrum of IEP (Fig. S1) shows a stretching vibration signal at 1595 cm−1, which can be attributed to the C[double bond, length as m-dash]N formed during the reaction. In addition, the peak at 1672 cm−1 of 2,5-dimethoxyterephthalaldehyde (Dp) and the stretching vibration peak at 3199 ∼ 3464 cm−1 of 2,4,6-tris-(4-aminophenyl)-s-triazine (Tz) almost disappeared, indicating that the C[double bond, length as m-dash]O of Dp and –NH2 of Tz were almost completely consumed. The remaining weak signal peaks of C[double bond, length as m-dash]O and –NH2 in IEP represent unreacted edge aldehydes and amino groups. The 13C NMR spectrum of IEP shows that peak 7 which appeared at 153.1 ppm can be attributed to the formation of C[double bond, length as m-dash]N (Fig. S2). The crystallinity of IEP was tested by powder X-ray diffraction (PXRD) measurement. As shown in Fig. 1a, there is a strong signal peak at 2.76° in the experimental X-ray diffraction pattern, which can be attributed to the reflection from (100) planes. Several other weak signal peaks, such as 4.89°, 5.82°, 7.61°, 9.70° and 24.9°, can be attributed to the reflection from the (110), (200), (210), (220) and (001) planes. The stacking method corresponded with AA-stacking (Fig. 1b) by comparison with the PXRD simulation pattern of IEP (Fig. 1a, black curve). The interlayer distance d was calculated to be 3.57 A to confirm the π–π interaction between adjacent layers (Fig. 1c). In addition, transmission electron microscopy (TEM) confirmed that IEP is a layered nanosheet, as shown in Fig. 1d.
image file: d3ra01540h-f1.tif
Fig. 1 (a) The experimental data (red) and simulated data (black) of the PXRD pattern, (b) top view, (c) side view and (d) TEM images for IEP.

The Brunauer–Emmett–Teller (BET) surface area and permanent porosity of IEP were estimated by the nitrogen adsorption isotherm of the activated sample at 77 K. As shown in Fig. 2a, the nitrogen adsorption isotherm of IEP shows a typical IV-type adsorption–desorption curve. Furthermore, based on the non-local density functional theory method, the BET surface area and the pore volume were estimated to be 870 m2 g−1 and 3.4 cm3 g−1, and the average pore size was estimated to be 2.3 nm (Fig. 2b).


image file: d3ra01540h-f2.tif
Fig. 2 (a) The nitrogen adsorption isotherm and (b) average pore size distribution for IEP and IEP-MnO2; (c) the experimental data of the PXRD pattern for IEP, IEP-MnO2 and MnO2; (d) the FT-IR spectrum of IEP, IEP-MnO2 and IEP-MnO2 + GSH.

2.2 Characterization of the IEP-MnO2 composite

By a simple synthesis method, 5 mg IEP and 10 mg MnO2 nanocrystals were mixed in 10 mL ethanol, sonicated for 5 min, and then stirred at room temperature for 4 h. The collected dark green product was washed three times with ethanol and vacuum dried at 80 °C for 12 h to obtain IEP-MnO2.

The PXRD pattern of IEP-MnO2 is shown in Fig. 2c. The strong diffraction peak at 2.76° indicates that the composite IEP-MnO2 maintains good crystallinity. At the same time, the lower diffraction peaks at 28.81°, 33.07° and 37.42° indicate the successful loading of MnO2 nanocrystals. The FT-IR spectrum was recorded in order to further confirm that MnO2 was successfully loaded on the IEP. As shown in Fig. 2d, compared with the FT-IR spectrum of IEP, the signal at 1595 cm−1 remained consistent, indicating that the structure of IEP-MnO2 was not destroyed. Moreover, the stretching vibration range of 500 cm−1 ∼ 600 cm−1 of IEP-MnO2 represents manganese oxide species.

The BET surface area and the pore volume of IEP-MnO2 were estimated to be 370 m2 g−1 and 1.75 cm3 g−1 (Fig. 2a and b) by the nitrogen adsorption isotherm at 77 K. Moreover, the average pore size of IEP-MnO2 still remained at 2.3 nm. MnO2 loaded on IEP was observed by TEM and element mapping (Fig. 3 and S3). It can be observed by TEM images that MnO2 nanocrystals with an average size of 50 nm are successfully loaded on the IEP sheet (Fig. S3). As shown in Fig. 3a, it can be observed that the lattice spacing of MnO2 nanocrystals is about 0.25 nm, and the element mapping of IEP-MnO2 (Fig. 3b) proved the existence of manganese.


image file: d3ra01540h-f3.tif
Fig. 3 (a) The TEM images and (b) element mapping spectrum for IEP-MnO2.

The thermal stability of IEP and IEP-MnO2 was determined by thermogravimetric analysis. As shown in Fig. S4, the thermal decomposition temperatures of IEP and IEP-MnO2 are 319 °C and 293 °C, respectively. The dynamic light scattering (DLS) spectra confirmed that the particle sizes of IEP and IEP-MnO2 were distributed in the ranges of 360–590 nm and 190–308 nm, and the main dimensions are 463 nm and 242 nm, respectively (Fig. S4a and b). In addition, the zeta potentials (ζ) of IEP and IEP-MnO2 were also measured, and the results are −7.11 mV and −4.97 mV, respectively (Fig. S4c and d).

2.3 Mechanism of IEP fluorescence quenching by MnO2

As shown in Fig. S6a, the maximum fluorescence emission of IEP was 523 nm under excitation at 406 nm measured using a fluorescence spectrophotometer. MnO2 shows a wide range of absorption from 300 nm to 800 nm. As shown in Fig. S6b, compared with IEP, the maximum fluorescence of IEP-MnO2 was not changed, but the intensity reduced greatly, suggesting the FRET effect between IEP and MnO2. In addition, decay traces of IEP and IEP-MnO2 in PBS buffer solution were obtained by single photon timing (SPT). The fluorescence decay of IEP is fitted to the biexponential profile with lifetimes of 5.63 ns and 13.98 in PBS buffer solution. Moreover, the fluorescence lifetimes of IEP-MnO2 are 5.92 ns and 14.38 ns, respectively (Table 1). There is almost no difference in fluorescence lifetime between IEP and IEP-MnO2, which implies that the process of fluorescence quenching for IEP-MnO2 is static quenching.
Table 1 The fluorescence lifetimes and percentage of IEP, IEP-MnO2, IEP-MnO2 + GSH, IEP-MnO2 + Cys, and IEP-MnO2 + Hcy (global analyst results of different emission wavelengths at 508 nm, 523 nm and 538 nm). CIEP = CIEP-MnO2 = 0.05 mg mL−1; CGSH = CCys = CHcy = 5 mM
Test group τ1/ns τ2/ns τ3/ns χ2 [small tau, Greek, macron]/ns
IEP 5.6 ± 0.002 (30.66%) 13.9 ± 0.004 (69.34%) 1.014 11.42
IEP-MnO2 5.9 ± 0.002 (25.82%) 14.38 ± 0.001 (74.18%) 1.011 12.2
IEP-MnO2 + GSH 5.1 ± 0.002 (29.79%) 14.31 ± 0.001(70.21%) 1.042 11.5
IEP-MnO2 + Cys 4.7 ± 0.004 (20.08%) 13.42 ± 0.001 (64.10%) 0.38 ± 0.045 (15.82%) 1.079 9.62
IEP-MnO2 + Hcy 5.2 ± 0.003 (27.25%) 12.90 ± 0.001 (62.11%) 0.52 ± 0.052 (10.64%) 1.077 9.50


2.4 Detection of GSH and Cys by IEP-MnO2 in PBS buffer solution

The fluorescence emission intensity of IEP-MnO2 after adding different concentrations of GSH was recorded using a fluorescence spectrophotometer. As shown in Fig. 4a, as the concentration of GSH increases, the emission intensity of IEP-MnO2 gradually increases, and finally reaches its maximum value when 5 mM GSH is added. Since the fluorescence emission of IEP-MnO2 increases linearly in the GSH concentration range of 0–0.1 mM, the limit of detection (LOD) of GSH is calculated to be 1.79 μM through the detection limit calculation formula LOD = 3σ/k (details about the formula are shown in the ESI) in this range (Fig. 4b). On the contrary, as the concentration of Cys increases, the fluorescence emission intensity of IEP-MnO2 decreases a lot, and reaches a minimum when 2 mM Cys is added (Fig. 4c) and the LOD of Cys is estimated to be 19.33 μM under the concentration range of 0–2 mM. By comparison with other methods of detecting biological thiols, it can be observed that IEP-MnO2 has a wider linear range (Table S1).
image file: d3ra01540h-f4.tif
Fig. 4 (a and c) Fluorescence emission spectrum of IEP-MnO2 suspension at different concentrations of GSH or Cys in DMSO (dimethyl sulfoxide)/H2O PBS buffer (1[thin space (1/6-em)]:[thin space (1/6-em)]9, v/v, 20 mM, pH = 7.4); (b and d) the calibration curve of IEP-MnO2 for GSH or Cys concentration titration. Error bars represent the standard error derived from three repeated measurements. CIEP-MnO2 = 0.05 mg mL−1, λex = 406 nm, λem = 523 nm.

The time-dependent experiment was carried out with consistent conditions except for adding different concentrations of GSH or Cys. As shown in Fig. S8a, it was observed that IEP-MnO2 and different concentrations of GSH were completely reacted at about 30 min. Similarly, when different concentrations of Cys were added, the reaction times were approximately 28 min (Fig. S8b). In addition, the light stability test confirmed that the structure and fluorescence emission of IEP-MnO2 remained stable within 30 min under the excitation wavelength of 406 nm (Fig. S9). Selectivity experiments were performed by adding other kinds of amino acids, sulfur-containing anions, H2O2 and ascorbic acid at the same concentration. After 30 min, the ratio of fluorescence emission intensity for all experimental groups (F) to the initial fluorescence emission intensity of IEP-MnO2 (F0) was calculated (Fig. S10). Obviously, the fluorescence of IEP-MnO2 was quenched when Cys or Hcy was added. The reason for fluorescence quenching was the combination of Cys/Hcy and nitrogen atoms of IEP through hydrogen bonding; thereby, the PET process occurred (Fig. S11).14,26 The process can also be confirmed by single photon timing (SPT). When Cys/Hcy were added to IEP-MnO2 PBS buffer solution, the fluorescence decays showed triple-exponential nature. As shown in Table 1, after adding Cys, the lifetimes are 4.79 ns, 13.42 and 0.38 ns, and after adding Hcy, the average lifetimes are 5.24 ns, 12.90 ns and 0.52 ns. The two slow decay times after adding Cys/Hcy to the IEP-MnO2 PBS buffer solution are similar to those of IEP-MnO2 (5.92 ns and 14.38 ns) in PBS buffer. The contributions of the third decay time of IEP-MnO2 + Cys (τ3 ≈ 0.38 ns) and IEP-MnO2 + Hcy (τ3 ≈ 0.52 ns) components are 15.8% and 10.6%, respectively, which can be attributed to the lifetime of the PET state.25 Density functional theory (DFT) calculations confirm the PET process. As shown in Fig. 5, the LUMO energy of the IEP-Cys is lower than that of IEP, when IEP is excited by the incident light, the excited state electrons of IEP transition to the LUMO of the IEP-Cys, and the fluorescence of IEP is quenched. On the contrary, the LUMO energy of IEP-Hcy is higher than that of IEP; thus, excited state electrons of IEP-Hcy would transition to the LUMO of IEP, resulting that the ground state electrons of IEP are unable to be excited, and thus the fluorescence quenching. However, the fluorescence decay for IEP-MnO2 + GSH in PBS buffer solution revealed bi-exponential behavior similar to IEP-MnO2 with lifetimes of 5.17 ns and 14.31 ns (Table 1). This result indicates that IEP cannot combine with GSH through a hydrogen bond to touch off the electron transfer process.


image file: d3ra01540h-f5.tif
Fig. 5 The theoretical HOMO–LUMO and possible PET processes of IEP, IEP-Cys, and IEP-Hcy.

In order to further illustrate the combination of Cys/Hcy and IEP, TPB-DMTP-COF was synthesized according to the literature,33 where 2,4,6-tris(4-aminophenyl)-s-triazine (triazine ring) was replaced by 1,3,5-tris(4-aminophenyl)benzene (benzene ring). The crystallinity and structure of TPB-DMTP-COF were characterized by PXRD and FT-IR spectrum (Fig. S12 and S13). The maximum emission wavelength of TPB-DMTP-COF is 525 nm under excitation at 415 nm. The fluorescence of TPB-DMTP-COF was quenched after adding Cys/Hcy, but the quenching degree is lower than that of IEP (Fig. S14), which means that the nitrogen atoms of the triazine ring and imine bond in IEP connect with Cys/Hcy through hydrogen bonds and promoted PET. In addition, as shown in Table S2, the fluorescence decay of TPB-DMTP-COF exhibits triple-exponential behavior with three fluorescence lifetimes, 0.68 ns, 4.15 ns and 14.96 ns, respectively. TPB-DMTP-COF + Cys and TPB-DMTP-COF + Hcy exhibit triple-exponential behavior and the lifetime of TPB-DMTP-COF + Cys and TPB-DMTP-COF + Hcy is 0.22 ns, 3.01 ns, 14.05 ns and 0.27 ns, 5.52 ns, 13.24 ns, respectively. The increased content of fast decay time (from 7.58% to 20.28% and 13.74%) implies the PET effect of TPB-DMTP-COF + Cys/Hcy.

In order to test the stability of IEP-MnO2 under different pH conditions, the fluorescence emission of IEP-MnO2 was tested in the range of pH = 5.5–10. As shown in Fig. S15, when pH = 5.5, IEP-MnO2 emits strong fluorescence, and the emission intensity decreases gradually with the increase of pH and finally remains stable when pH > 8. It can be attributed to the decomposition of MnO2 under acidic conditions, and emission of IEP was released. In order to be consistent with the biological environment, pH = 7.4 is selected as the experimental condition.

2.5 Detection of GSH in human whole blood and Cys in serum by IEP-MnO2

Based on the above research, we tried to use IEP-MnO2 (0.1 mg mL−1) in the complex human whole blood environment to make it possible to detect GSH in vitro. In 50 times diluted human whole blood through HEPES buffer (10 mM, pH = 7.4), IEP-MnO2 shows double launch properties in diluted whole blood, with emission wavelengths at 522 nm and 640 nm. The emission intensity of IEP-MnO2 obviously increases as the concentration of external GSH increases until it reaches its maximum after adding 1.7 mM GSH (Fig. 6a). Furthermore, the LOD is calculated to be 25.58 μM within the GSH concentration range of 0–1 mM (Fig. 6b). In addition, IEP-MnO2 was also used to detect Cys in 50 times diluted human serum (PBS, 20 mM, pH = 7.4). As shown in Fig. 6c, the fluorescence emission intensity of IEP-MnO2 decreased a lot when 3 mM Cys was added and the LOD of Cys was calculated to be 4.43 μM in the concentration range of 0–0.25 mM (Fig. 6d). The results indicated that IEP-MnO2 could detect GSH or Cys in complex biological environments.
image file: d3ra01540h-f6.tif
Fig. 6 (a) The fluorescence emission spectrum of IEP-MnO2 suspension at different concentrations of GSH and (b) the calibration curve of IEP-MnO2 for GSH concentration titration in human whole blood. CIEP-MnO2 = 0.1 mg mL−1, λex = 406 nm, λem = 522 nm. (c) The fluorescence emission spectrum of IEP-MnO2 suspension at different concentrations of Cys and (d) the calibration curve of IEP-MnO2 for Cys concentration titration in human serum. CIEP-MnO2 = 0.1 mg mL−1, λex = 406 nm, λem = 522 nm. Error bars represent the standard error derived from three repeated measurements.

Next, based on the previously reported GSH content in the human whole blood by HPLC,9 the concentration of GSH in the whole blood after 50-fold dilution was estimated to be 16.89 μM. After that, 3 groups of whole blood with additional 20 μM and 50 μM were added, and they were found to have good reproducibility by comparison with the standard curve (Table S3). The actual concentration of Cys in serum is also determined by the same method.34–36 The Cys concentration in 50-fold diluted serum samples was determined according to published reports and excellent reproducibility was found by adding 40 and 90 μM Cys (Table S4).

2.6 The detection mechanism of GSH and Cys

IEP-MnO2 can be reduced to IEP and Mn2+, which makes IEP-MnO2 a “turn on” sensor for detecting GSH. The detection process was characterized by TEM, FT-IR spectroscopy, PXRD, and inductively coupled plasma mass spectrometry (ICP-MS). As shown in Fig. S3, the TEM image shows that the MnO2 nanocrystals loaded on IEP completely disappeared after adding GSH. The signal peak of MnO2 on the FT-IR spectrum of IEP-MnO2 + GSH also disappeared completely (Fig. S16). Compared to IEP-MnO2, the diffraction peaks at 28.81°, 33.07° and 37.42° which represent MnO2 nanocrystals disappeared (Fig. S17). ICP-MS proves the presence of Mn2+ in the detection system. In addition, due to the hydrogen bonds between Cys/Hcy and IEP, the fluorescence of IEP was quenched through the PET effect. It is worth noting that, due to the excessive steric hindrance of the amino part of GSH, it cannot be combined with IEP to make the fluorescence of IEP quenched.

3 Conclusion

In this work, the fluorescent covalent organic framework IEP was synthesized by the hydrothermal method, and then MnO2 nanocrystals were loaded on IEP by simple room temperature stirring to form the composite material IEP-MnO2. After adding GSH or Cys, the fluorescence emission spectrum of IEP-MnO2 changed (“turn-on” or “turn-off”) via different mechanisms. Since the fluorescence of IEP was quenched by MnO2 through the FRET effect, and MnO2 can be reduced to Mn2+ by GSH, the composite material IEP-MnO2 as a “turn-on” fluorescent sensor plays an important role in detecting GSH in PBS buffer solution and human whole blood. More interestingly, due to the electron transfer process between the COF skeleton and Cys/Hcy, the fluorescence of IEP is quenched by Cys/Hcy, and IEP-MnO2 can be used to detect Cys in human serum. Therefore, IEP-MnO2 was successfully used in distinguishing detection of GSH and Cys. This work expands the application of COFs in fluorescent sensing and interprets their unparalleled advantages as fluorescent sensors.

Conflicts of interest

We declare that there is no conflict of interest.

Acknowledgements

The authors would like to thank the Natural Science Foundation of China (no. 21771092). The authors also thank the Supercomputing Center of the Lanzhou University for DFT calculations.

References

  1. H. M. Meng, Z. Jin, Y. Lv, C. Yang, X. B. Zhang, W. Tan and R. Q. Yu, Anal. Chem., 2014, 86, 12321–12326 CrossRef CAS PubMed.
  2. D. Fan, C. Shang, W. Gu, E. Wang and S. Dong, ACS Appl. Mater. Interfaces, 2017, 9, 25870–25877 CrossRef CAS PubMed.
  3. T. Du, H. Zhang, J. Ruan, H. Jiang, H. Y. Chen and X. Wang, ACS Appl. Mater. Interfaces, 2018, 10, 12417–12423 CrossRef CAS PubMed.
  4. C. X. Yin, K. M. Xiong, F. J. Huo, J. C. Salamanca and R. M. Strongin, Angew. Chem., Int. Ed., 2017, 56, 13188–13198 CrossRef CAS PubMed.
  5. G. X. Yin, T. T. Niu, Y. B. Gan, T. Yu, P. Yin, H. M. Chen, Y. Y. Zhang, H. T. Li and S. Z. Yao, Angew. Chem., Int. Ed., 2018, 57, 4991–4994 CrossRef CAS PubMed.
  6. Z. Liu, X. Zhou, Y. Miao, Y. Hu, N. Kwon, X. Wu and J. Yoon, Angew. Chem., Int. Ed., 2017, 56, 5812–5816 CrossRef CAS PubMed.
  7. D. Gong, S. C. Han, A. Iqbal, J. Qian, T. Cao, W. Liu, W. Liu, W. Qin and H. Guo, Anal. Chem., 2017, 89, 13112–13119 CrossRef CAS PubMed.
  8. N. M. Afsaneh Safavi, E. Farjami and F. A. Mahyari, Anal. Chem., 2008, 81, 7538–7543 CrossRef PubMed.
  9. R. G. France Michelet, P. Leroy, M. Wellman, A. Nicolas and G. Siest, Clin. Chem., 1995, 41, 1509–1517 CrossRef.
  10. P. Jin, X. Niu, F. Zhang, K. Dong, H. Dai, H. Zhang, W. Wang, H. Chen and X. Chen, ACS Appl. Mater. Interfaces, 2020, 12, 20414–20422 CrossRef CAS PubMed.
  11. X. Wang, D. Wang, Y. Guo, C. Yang, X. Liu, A. Iqbal, W. Liu, W. Qin, D. Yan and H. Guo, Biosens. Bioelectron., 2016, 77, 299–305 CrossRef CAS PubMed.
  12. Q. Y. Cai, J. Li, J. Ge, L. Zhang, Y. L. Hu, Z. H. Li and L. B. Qu, Biosens. Bioelectron., 2015, 72, 31–36 CrossRef CAS PubMed.
  13. X. Yan, Y. Song, C. Zhu, J. Song, D. Du, X. Su and Y. Lin, ACS Appl. Mater. Interfaces, 2016, 8, 21990–21996 CrossRef CAS PubMed.
  14. S. Dalapati, S. Jin, J. Gao, Y. Xu, A. Nagai and D. Jiang, J. Am. Chem. Soc., 2013, 135, 17310–17313 CrossRef CAS PubMed.
  15. S. Wan, J. Guo, J. Kim, H. Ihee and D. Jiang, Angew. Chem., Int. Ed., 2009, 48, 5439–5442 CrossRef CAS PubMed.
  16. G. Lin, H. Ding, D. Yuan, B. Wang and C. Wang, J. Am. Chem. Soc., 2016, 138, 3302–3305 CrossRef CAS PubMed.
  17. L. Ascherl, E. W. Evans, M. Hennemann, D. Di Nuzzo, A. G. Hufnagel, M. Beetz, R. H. Friend, T. Clark, T. Bein and F. Auras, Nat. Commun., 2018, 9, 3802 CrossRef PubMed.
  18. Y. Li, M. Chen, Y. Han, Y. Feng, Z. Zhang and B. Zhang, Chem. Mater., 2020, 32, 2532–2540 CrossRef CAS.
  19. Z. Zhou, W. Zhong, K. Cui, Z. Zhuang, L. Li, L. Li, J. Bi and Y. Yu, Chem. Commun., 2018, 54, 9977–9980 RSC.
  20. Z. Li, Y. Zhang, H. Xia, Y. Mu and X. Liu, Chem. Commun., 2016, 52, 6613–6616 RSC.
  21. S. Y. Ding, M. Dong, Y. W. Wang, Y. T. Chen, H. Z. Wang, C. Y. Su and W. Wang, J. Am. Chem. Soc., 2016, 138, 3031–3037 CrossRef CAS PubMed.
  22. W. K. Haug, E. M. Moscarello, E. R. Wolfson and P. L. McGrier, Chem. Soc. Rev., 2020, 49, 839–864 RSC.
  23. Z. Li, N. Huang, K. H. Lee, Y. Feng, S. Tao, Q. Jiang, Y. Nagao, S. Irle and D. Jiang, J. Am. Chem. Soc., 2018, 140, 12374–12377 CrossRef CAS PubMed.
  24. M. W. Zhu, S. Q. Xu, X. Z. Wang, Y. Chen, L. Dai and X. Zhao, Chem. Commun., 2018, 54, 2308–2311 RSC.
  25. P. Das, G. Chakraborty and S. K. Mandal, ACS Appl. Mater. Interfaces, 2020, 12, 10224–10232 CrossRef CAS PubMed.
  26. D. Kaleeswaran, P. Vishnoi and R. Murugavel, J. Mater. Chem. C, 2015, 3, 7159–7171 RSC.
  27. C. Zhang, S. Zhang, Y. Yan, F. Xia, A. Huang and Y. Xian, ACS Appl. Mater. Interfaces, 2017, 9, 13415–13421 CrossRef CAS PubMed.
  28. X. Zhao, Y. Li, Z. Chang, L. Chen and X. H. Bu, Dalton Trans., 2016, 45, 14888–14892 RSC.
  29. W. Li, C. X. Yang and X. P. Yan, Chem. Commun., 2017, 53, 11469–11471 RSC.
  30. A. Mal, R. K. Mishra, V. K. Praveen, M. A. Khayum, R. Banerjee and A. Ajayaghosh, Angew. Chem., Int. Ed., 2018, 57, 8443–8447 CrossRef CAS PubMed.
  31. P. Wang, F. Zhou, C. Zhang, S. Y. Yin, L. Teng, L. Chen, X. X. Hu, H. W. Liu, X. Yin and X. B. Zhang, Chem. Sci., 2018, 9, 8402–8408 RSC.
  32. D. Mullangi, D. Chakraborty, A. Pradeep, V. Koshti, C. P. Vinod, S. Panja, S. Nair and R. Vaidhyanathan, Small, 2018, 14, e1801233 CrossRef PubMed.
  33. S. T. Qing Xu, Q. Jiang and D. Jiang, J. Am. Chem. Soc., 2018, 140, 7429–7432 CrossRef PubMed.
  34. H. J. Forman, H. Zhang and A. Rinna, Mol. Aspects Med., 2009, 30, 1–12 CrossRef CAS PubMed.
  35. M. Isokawa, T. Kanamori, T. Funatsu and M. Tsunoda, J. Chromatogr. B: Anal. Technol. Biomed. Life Sci., 2014, 964, 103–115 CrossRef CAS PubMed.
  36. R. Ferin, M. L. Pavao and J. Baptista, J. Chromatogr. B: Anal. Technol. Biomed. Life Sci., 2012, 911, 15–20 CrossRef CAS PubMed.

Footnotes

Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3ra01540h
These authors contributed equally to this article.

This journal is © The Royal Society of Chemistry 2023