Gabriele
Baglioni
*a,
Roberto
Pezone
b,
Sten
Vollebregt
b,
Katarina
Cvetanović Zobenica
c,
Marko
Spasenović
c,
Dejan
Todorović
d,
Hanqing
Liu
e,
Gerard J.
Verbiest
e,
Herre S. J.
van der Zant
a and
Peter G.
Steeneken
*ae
aKavli Institute of Nanoscience, Delft University of Technology, The Netherlands. E-mail: G.Baglioni@tudelft.nl; P.G.Steeneken@tudelft.nl
bLaboratory of Electronic Components, Technology and Materials, Delft University of Technology, The Netherlands
cCenter for Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy, University of Belgrade, Serbia
dDirigent Acoustics Ltd, Belgrade, Serbia
eDepartment of Precision and Microsystems Engineering, Delft University of Technology, The Netherlands
First published on 9th March 2023
Microphones exploit the motion of suspended membranes to detect sound waves. Since the microphone performance can be improved by reducing the thickness and mass of its sensing membrane, graphene-based microphones are expected to outperform state-of-the-art microelectromechanical (MEMS) microphones and allow further miniaturization of the device. Here, we present a laser vibrometry study of the acoustic response of suspended multilayer graphene membranes for microphone applications. We address performance parameters relevant for acoustic sensing, including mechanical sensitivity, limit of detection and nonlinear distortion, and discuss the trade-offs and limitations in the design of graphene microphones. We demonstrate superior mechanical sensitivities of the graphene membranes, reaching more than 2 orders of magnitude higher compliances than commercial MEMS devices, and report a limit of detection as low as 15 dBSPL, which is 10–15 dB lower than that featured by current MEMS microphones.
Being ultrathin and lightweight, suspended graphene membranes are excellent candidates for use in electrostatically actuated devices9–11 and sensors,12 such as pressure sensors,13–15 gas sensors16 and accelerometers17 as well as microphones.18–25 Thanks to their atomic thickness, graphene membranes could be made more than a factor 100–1000 times thinner than typical 0.1–1.0 μm thick MEMS membranes, resulting in a significant increase of the microphone mechanical sensitivity without requiring complex device structures. On top of that, graphene is an excellent conductor and thus requires no additional layer for electrical readout. Previous studies have demonstrated the fabrication of microphones using graphene-based membranes either with multilayer graphene18–20 or with a composite structure made of bilayer or multilayer graphene and a thick (>100 nm) PMMA layer.21–25 In general, these works focused on fabricating a condenser microphone structure, involving either wet or dry transfer20–22 of large graphene membranes (from 2 to 12 mm in diameter) over pre-patterned substrates or via dry etching of a sacrificial layer.23 In these devices, the incoming sound is transduced to an electrical signal via the change in capacitance between a fixed backplate and the movable membrane. Although these works have demonstrated successful capacitive readout of audio signals with high output voltage per unit pressure, other important device performance parameters, like the mechanical sensitivity, the signal-to-noise ratio (SNR), total harmonic distortion (THD), bandwidth and dynamic range, have been less extensively characterized. Following common conventions for microphone specifications, we define these parameters using the reference input frequency and reference pressure level as 1 kHz and 1 Pa = 94 dBSPL respectively:
• Sensitivity: ratio between electrical output and input sound pressure, usually expressed in mV Pa−1 for capacitive microphones. This overall sensitivity is a combination of electrical sensitivity, which depends on the readout-circuit and amplification, and mechanical sensitivity.2 In this work, we address the mechanical sensitivity, given by the ratio between membrane's displacement and input pressure which strongly depends on the material properties and membranes dimensions.
• Signal-to-noise ratio (SNR): ratio between output in response from a reference signal (1 kHz at 1 Pa) and noise level of the microphone.
• Dynamic range: difference between the maximum and minimum sound pressure level that the microphone can handle. The maximum detectable sound is determined by the amount of nonlinear distortion in the microphone response.
• Total harmonic distortion (THD): measures the level of distortion at the output and it is defined as the ratio between the sum of the powers of the harmonics and the fundamental tone. Maximum detectable sound is determined by the acoustic overload point (AOP) corresponding to THD = 10%.
In this work, we use a Laser Doppler Vibrometer (LDV) to carry out a detailed study of the response of multilayer graphene (MLG) membranes to acoustic actuation, and determine their most important performance parameters such that they can be compared to the stateof-the-art. The advantage of optical vibrometry is that it allows direct determination of the mechanical response of graphene membranes to sound, in contrast to electrical methods, where the output voltage depends on the specifics of the readout circuit. Moreover, by using it to characterize freestanding membranes, it allows measurement of the intrinsic membrane characteristics without including effects of a backplate that is used in capacitive condenser microphones. Thus, we gain deeper insights into graphene's acoustic properties, which is crucial for the design of future MEMS graphene microphones.
A soundproof box encloses the setup to reduce influence of background noise.
An optical picture of a typical graphene membrane and its schematic cross-section are shown in Fig. 1b and c. The free-standing membranes are made of multilayer graphene with a thickness of ∼8 nm grown on Si/SiO2/Mo (50 nm) by Low-Pressure Chemical Vapor Deposition in an Aixtron Black Magic reactor at 1000 °C with H2–CH4 as carbon precursor source. The Mo seed layer under the graphene is wet-etched with H2O2 and deionized water, after which the graphene remains on the Si/SiO2 substrate.26 The graphene is finally immersed in DI-water until it delaminates and it is carefully wet-transferred on a Si/SiO2 substrate (thickness of ∼520 μm) with pre-patterned holes. These holes, with a diameter of ∼350–600 μm were etched through the silicon chips by Deep Reaction Ion Etching (DRIE) and buffered oxide etch (BOE) to remove the SiO2 hard mask. Finally, the chip with suspended graphene membranes is dried in atmospheric conditions for >10 hours.
The graphene used in this study has been found to be strong enough to sustain drying in atmospheric conditions, without a need for critical point drying. The high mechanical quality of the graphene is related to its high uniformity.27 Furthermore, the membranes are completely freely suspended over the through holes, which alleviates the possibility of liquid formation between the graphene and the substrate. The crystallinity of the graphene as well as its thickness were investigated via Raman and atomic force microscopy (see Fig. S1 and S2 in the ESI†).
Following this methodology, we characterize the acoustic response of multilayer graphene membranes of varying diameters, as well as the membrane of a commercial MEMS microphone from ST-Microelectronics (MP23DB01HP), and compare their performance. To avoid confusion with other MEMS devices from literature, the commercial device is referred to as ‘ST MEMS microphone’ in the rest of the manuscript. In Fig. 3a, the frequency response of four graphene drums with a diameter d = 350 μm is shown together with the response of the ST MEMS microphone (d = 950 μm). Also, the mechanical sensitivity at 1 kHz (Sm,1 kHz) of the 37 measured drums is shown in Fig. S3 of the ESI.†
![]() | ||
Fig. 3 Sensitivity in the audible spectrum. (a) Audio response spectra of graphene membranes (d = 350 μm) and the Si membrane in the ST MEMS microphone. Drawn lines are fits to the data using a harmonic oscillator model. (b) Acoustic sensitivity of 16 different graphene membranes with d = 350 μm at 1 kHz plotted against the fundamental resonant frequency f0 measured in vacuum with a scanning LDV (as discussed in detail in section 3 of the ESI†). Differences in resonance frequency and sensitivity are attributed to variations in pretensions induced by the transfer process. |
This quantity is defined as where Δz1 kHz is the AC amplitude of the membrane centre at 1 kHz and ΔP1 kHz is the input sound pressure amplitude at 1 kHz. Even though large differences in sensitivity between graphene membranes are observed, all graphene membranes exhibit much higher mechanical sensitivities (up to ∼2000 nm Pa−1) than the ST MEMS microphone with Sm,1 kHz ∼1.3 nm Pa−1.
To analyze these results, the data points in Fig. 3a were fit (drawn lines) using a harmonic oscillator model, yielding a frequency dependent mechanical sensitivity Sm(ω)
![]() | (1) |
![]() | (2) |
According to eqn (1), the main parameter determining Sm(0) is the pretension. Thus, variation in sensitivity observed between the devices in Fig. 3 is likely due to fabrication induced differences in pretension. To check this hypothesis, we consider the equation for the fundamental resonance frequency, f0, of a circular membrane and its relation to the mechanical sensitivity Sm(0):
![]() | (3) |
To remove the influence of air loading effects on the resonance frequency, we also measure the membranes’ resonance frequency in vacuum using a scanning laser Doppler vibrometer (MSA400 Micro System Analyzer). The sample is placed inside a vacuum chamber (∼10−3 mbar) equipped with a piezo shaker to actuate the membrane. The displacement is measured over a user-defined grid of points distributed over the surface of the membrane. Thus the membrane mode shape can be reconstructed to identify the first resonance mode (see section 3 of the ESI for more details†).
In Fig. 3b we plot the sensitivity at 1 kHz against f0 measured using a scanning LDV in vacuum. The data in Fig. 3b follows the theoretically expected relation Sm ∝ f0−2, showing that the experimental differences in sensitivity observed in Fig. 3b can indeed be well accounted for by variations in n0. Fig. S3b in the ESI,† shows correlations between mechanical sensitivity and resonance frequencies measured in air from data like in Fig. 3a. Variations in pretension can be caused by forces on the graphene during the transfer process, and might also be induced by wrinkles in the membranes (see Fig. S5 in the ESI†).
A high sensitivity does not automatically guarantee that a microphone can detect weak sounds, because its limit of detection (LOD) also depends on the noise level. To determine the LOD, we measured the membrane displacement at 1 kHz for different driving amplitudes to investigate the minimum detectable sound pressure level (SPL). Fig. 4a shows the displacement signal from the vibrometer in response to a 1 kHz tone at low SPL (<35 dBSPL) for the ST MEMS microphone and three graphene membranes with different mechanical sensitivity (labelled as G1, G4, G6) and d = 350 μm. The vibration amplitude at 1 kHz as a function of the input SPL, as obtained from the peak heights in Fig. 4a using the vibrometer responsivity of 200 nm V−1, is shown in Fig. 4b for the four devices. The measured average noise level for each sample is depicted with a dashed line of the corresponding colour. For SPL > 30 dBSPL, the response peak at 1 kHz is visible in all samples with varying amplitudes depending on the sample's mechanical sensitivity. When decreasing the input SPL, the 1 kHz peak becomes comparable to the noise level at ∼30–32 dBSPL for the ST MEMS microphone and G1, while for G4 and G6 the extrapolated signal stays above the noise level down to 25 and 15 dBSPL respectively, which is significantly lower than the lowest SPL of 70 dBSPL at which graphene membranes were tested in literature21 up to now. The extrapolated LOD of ∼15 dBSPL of device G6 is even lower than the specified LOD of the reference microphone of 24 dBSPL used to measure the input SPL.
Fig. 4b shows that the noise level increases when the sensitivity increases due to a smaller stiffness k, because the thermomechanical noise induces a mean displacement given by: .28 The thermomechanically induced displacement power spectral density below resonance
can be calculated by extracting k from a linear fit to Fig. 5b and Q and ω0 from a harmonic oscillator fit to the resonances in air, leading to a theoretical value of the thermomechanical noise displacement density pSxx,n of ∼8, 1.8, 0.2 pm Hz−1 for sample G6, G4, G1 respectively. The noise level measured is ∼47, 17, 5 and 3 pm Hz−1 for sample G6, G4, G1 and the ST MEMS respectively, showing that the displacement noise in the membranes is near, but not at the theoretical limit.
![]() | ||
Fig. 5 Signal-to-noise ratio and harmonic distortion. (a) Comparison between displacement signal from graphene membranes (circles) and from the ST MEMS microphone (stars) in response to a 1 kHz tone at 1 Pa of rms SPL (= 94 dBSPL). The blue markers indicate the peak amplitude while the red markers indicate the noise floor of the spectra (like in Fig. 4a). Average SNR in graphene is 88 dB, 16 dB higher compared to that of the ST MEMS microphone. (b) Displacement amplitude at 1 kHz vs. SPL for several graphene drums and the ST MEMS microphone, extracted from spectra like in Fig. 4a. (c) Displacement spectrum of device G6 as a function of SPL of a 1 kHz tone from the speaker. (d) Total harmonic distortion (THD) versus SPL for the samples in 5b. The dashed line at THD = 10% marks the acoustic overload point (AOP). |
To determine the microphone performance at high sound pressure levels, similar measurements were performed at high SPL to study the dynamic range, the distortion and nonlinearity of the response. In Fig. 5a we show the response amplitude as well as the average noise level of some membranes to a 1 kHz tone of 1 Pa (= 94 dBSPL) to compare their signal-to-noise ratio SNR1 Pa,1 kHz = x1 Pa,1 kHz/pSxx,n to that of the ST MEMS microphone. On average, the noise level of the graphene membranes is higher compared to that of the ST MEMS microphone. However, due to their higher sensitivity at 94 dBSPL, the SNR (difference between blue and red data points in Fig. 5a) of the graphene microphones ranges from 80–95 dB, which is significantly larger than that of the ST MEMS microphone, which is 72 dB.
In Fig. 5b, we show the peak amplitude of the displacement signal in response to a 1 kHz tone between 50 dBSPL and 110 dBSPL. Louder acoustic signals were not used due to large distortion and clipping occurring in the speaker. All graphene samples exhibit a higher response than the ST MEMS microphone, but at a high SPL the most sensitive samples deviate from linear behaviour. This is to be expected as the linear approximation of eqn (2) holds in the limit of small displacements. Therefore, while sample G6 was the best at detecting low sound levels down to 20 dBSPL, its performance at high SPL gets worse due to non-linear effects limiting its dynamic range. The non-linear response of G6 and G4 was fitted to eqn (2) with t = 8 nm, 2R = 350 μm and ν = 0.26 yielding a pretension n0 ∼7 mN m−1 and 33 mN m−1 and a Young's modulus of E ∼5 GPa and 30 GPa for G6 and G4 respectively. The extracted Young's modulus is much lower than that of pristine graphene. This reduction could be due to defects that originate from graphene growth in the form of small holes of ∼50 nm, as observed by SEM inspection of the samples (see Fig. S6 in ESI†). In addition, transfer-induced wrinkles and slack in the membrane can further decrease the Young's modulus.29
To analyze the observed distortion, the spectrum of sample G6 in response to a 1 kHz tone with varying SPL at 1 kHz is shown in Fig. 5c. At higher SPL, harmonics of the driving frequency are visible in the spectrum. In order to measure the distortion level and maximum detectable SPL of the samples under study, we calculated the THD from the first five harmonics as:30
![]() | (4) |
In order to theoretically estimate the expected value of the THD, we assume periodic motion of the membrane z(t) = z0sin
ωt, which when substituted in eqn (2) yields
![]() | (5) |
![]() | (6) |
Fig. 6 shows the mechanical compliance as a function of membrane thickness for MEMS devices reported in ref. 2 (blue circles), for graphene-based microphones (red and purple hexagons), and for the multi-layer graphene (MLG) membranes presented here (green hexagon). The data points shown for the MLG membranes of our work include the membranes with highest and lowest compliance to highlight the range of measured values compared to previous reports in literature. The compliance of graphene-based membranes not listed in ref. 2 is estimated from the reported membrane pretension using , where the membrane's stiffness k = 4πn0 in the case of pressure deformation.33 Moreover, since n0 = σt where σ is the pre-stress of the membrane, we can identify lines of constant stress in the Cmvs. t plane. These are highlighted as dashed red lines in Fig. 6 with lower stress corresponding to lower opacity of the line. The high mechanical sensitivity of our membranes can thus be attributed to a combination of low stress and small thickness. The high stress reported on the t = 25 nm membrane in ref. 20 results from the large polarization voltage of 200 V used to readout the acoustic signal, which led to an estimated pretension of 640 N m−1.
![]() | ||
Fig. 6 Mechanical compliance of literature devices. Scatter plot of mechanical compliance vs. membrane's thickness for MEMS microphones from literature2 (blue circles), the ST MEMS microphone (yellow star), graphene microphone literature (purple and red hexagons for membranes with and without a backplate respectively) and for three graphene membranes in this work (green hexagon), including membranes with lowest and highest compliance measured. The dashed red lines indicates lines with constant stress, with lower stress corresponding to lines with lower opacity. The relevant reference numbers for the graphene microphones are indicated in the graph near the data points. |
We note that most microphone works in literature deal with membranes with a backplate for capacitive readout. Therefore, the lower compliance in these devices (at atmospheric pressure) can be partly explained by the effect of squeeze film damping. The graphene membranes under study do not have such a backplate, because we first wanted to determine the intrinsic properties of the graphene membranes themselves. Realizing efficient electrical microphone readout, e.g. via a perforated capacitive backplate, while maintaining this high sensitivity and compliance is another challenge that is outside the scope of this work.
Although lowering the tension and stiffness of graphene membranes helps to improve their acoustic sensitivity, a drawback is that it reduces the fundamental resonance frequency, thus limiting the microphone bandwidth (Fig. 3b). Since the mass of the graphene membranes is extremely low, and their aspect-ratio very high (d/t ∼46000), the mass of the air that moves along with the membrane is substantial, increasing the effective membrane mass meff.34,35 This mass increase further reduces the resonance frequency and bandwidth. Initial experiments showed a 5 to 9-fold decrease of the resonant frequency from vacuum ∼10−4 mbar to atmospheric conditions (see Fig. S4 in the ESI†). Further pressure-dependent measurements are needed to understand better this air mass loading effect as well as the importance of squeeze-film damping on future devices with backplate for capacitive readout.
In general, it is desirable to have the resonance frequency of the membrane above the audible range (>20 kHz). The membranes in this work, like in several other graphene microphone publications,18,22,23 do not satisfy this condition. However, it is important to note that depending on the target application, a bandwidth of 6–10 kHz can be sufficient,22,36 therefore the reported low resonance frequency (<10 kHz) of graphene membranes is not necessarily limiting for their performance. Nevertheless, this problem could be compensated for in next generation devices by increasing their pretension n0 or reducing the membrane radius R, while keeping competitive mechanical sensitivity. For example, as shown in ref. 37 graphene membranes with diameters of 85–150 μm exhibit resonance frequencies in vacuum of 250–320 kHz and mechanical sensitivities still comparable to a MEMS membrane with a diameter of 950 μm. For a fairer comparison, one can correct the obtained compliances in Fig. 6 by a factor (20 kHz/f0)2. Even after such a correction, the compliances obtained by the graphene membranes in this work are higher than most literature values as shown in Fig. S7 in the ESI.†
A main challenge in using graphene as a microphone is linked to the lack of control over its mechanical properties during the transfer process, which limits the reproducibility of the membrane's performance as shown in Fig. 3 and Fig. S3.† For microphone applications, large sheets of suspended CVD graphene are needed and thus a transfer step to the target substrate has been unavoidable in all previous studies. In addition to the poor uniformity and control of strain, the transfer process can degrade the quality of the graphene by introducing contamination, cracks and wrinkles, unwanted for practical application and large-scale production.38 In a recent study,37 wafer-scale fabrication of multilayer graphene membranes was achieved using a transfer-free method, by which the graphene is grown and released directly on the target substrate. This novel method could prove beneficial in terms of uniformity and scalability in fabrication of graphene-based microphones and sensors.
Finally, the most sensitive membranes are found to be more influenced by non-linear effects at high SPL, and exhibit higher distortion and reduced dynamic range. Graphene membranes cannot yet reach commercial values of THD, acoustic overload point (AOP = 140 dBSPL) and dynamic range (105 dBSPL31), also because they do not feature a doublebackplate configuration for differential readout which greatly reduces the THD and increases sensitivity.36 The trade-off between sensitivity and dynamic range could be further optimized by better control over the membrane's stiffness.
Footnote |
† Electronic supplementary information (ESI) available: Fig. S1: Raman spectrum of graphene samples; Fig. S2: AFM characterization of graphene samples; Fig. S3: Mechanical sensitivities at 1 kHz of all measured samples: Fig. S4: Measurements of resonance frequency in vacuum and comparison with resonance in air; Fig. S5: Effects of wrinkles on membrane's mode shape; Fig. S6: SEM pictures of graphene membranes; Fig. S7: Mechanical compliance corrected by resonance frequency; Fig. S8: Growth and transfer process of the graphene membranes; Movie V1: LynceeTec mode shape imaging of graphene membrane; Movie V2: LynceeTec mode shape imaging of wrinkled graphene membrane; Audio A1: music track (Ode to joy) recorded on optically on multilayer graphene membrane. See DOI: https://doi.org/10.1039/d2nr05147h |