Issue 35, 2023

Screening and detection of multivalent human papillomavirus antibodies using a high-throughput liquid chip fluoroimmunoassay system

Abstract

Immunoassays are commonly used in disease diagnosis and vaccine evaluation but can be costly and time-consuming when confronted with multivalent targets, such as antisera containing antibodies to human papillomavirus (HPV), because of their limited ability to discriminate between multiple analytes in a single reaction well. This study describes the development of a high-throughput liquid chip system that combines immunoassay techniques and magnetic beads to allow the simultaneous screening and quantitative detection of antibodies to four types of HPV using the Luminex fluoroimmunoassay system. Groups of beads embedded with fluorescent dyes at various ratios were coated with optimized HPV capture antigens and demonstrated excellent dose-dependent response to four monoclonal antibodies used as reference standards. This assay is sensitive, accurate, repeatable, and simple to perform, enabling multiplex antibody detection with a high degree of orthogonality. The performance of the Luminex system was compared with conventional immunoassays for quantitative detection of quadrivalent HPV antibodies in antisera of mice immunized with five lots of HPV vaccines, verifying the accuracy and detection efficiency of the assay. This strategy is a promising approach to characterizing antibodies present in polyclonal antisera and has promising applications in research, clinical, and industrial settings, for example, streamlining vaccine efficacy trials and vaccine lot inspection and release procedures.

Graphical abstract: Screening and detection of multivalent human papillomavirus antibodies using a high-throughput liquid chip fluoroimmunoassay system

Supplementary files

Article information

Article type
Paper
Submitted
07 Jun 2023
Accepted
14 Aug 2023
First published
16 Aug 2023

Anal. Methods, 2023,15, 4541-4547

Screening and detection of multivalent human papillomavirus antibodies using a high-throughput liquid chip fluoroimmunoassay system

H. Wang, R. Hu, Q. Huang, H. Zhang, E. Zhang and H. Yang, Anal. Methods, 2023, 15, 4541 DOI: 10.1039/D3AY00931A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements