Eleonora
Perego
a and
Sarah
Köster
*ab
aInstitute for X-Ray Physics, University of Göttingen, 37077 Göttingen, Germany. E-mail: sarah.koester@phys.uni-goettingen.de
bCluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
First published on 19th January 2021
Despite the importance for cellular processes, the dynamics of molecular assembly, especially on fast time scales, is not yet fully understood. To this end, we present a multi-layer microfluidic device and combine it with fluorescence fluctuation spectroscopy. We apply this innovative combination of methods to investigate the early steps in assembly of vimentin intermediate filaments (IFs). These filaments, together with actin filaments and microtubules, constitute the cytoskeleton of cells of mesenchymal origin and greatly influence their mechanical properties. We are able to directly follow the two-step assembly process of vimentin IFs and quantify the time scale of the first lateral step to tens of ms with a lag time of below 3 ms. Although demonstrated for a specific biomolecular system here, our method may potentially be employed for a wide range of fast molecular reactions in biological or, more generally, soft matter systems, as it allows for a precise quantification of the kinetics underlying the aggregation and assembly.
Fluorescence fluctuation spectroscopy (FFS) is a family of methods capable of detecting single fluorescently labeled objects based on the analysis of fluorescence fluctuations emitted over time within a confined observation volume.7 Fluorescence correlation spectroscopy (FCS) analyzes the time correlations of these fluctuations and provides information about protein mobility and, via the diffusion coefficient, size.8 Alternatively, the frequencies of the fluctuations can be evaluated to investigate the brightness of the fluorescent species, as in photon counting histogram (PCH) or in fluctuation intensity distribution analysis (FIDA).9,10 FFS is often employed to characterize molecular aggregation and protein–protein interactions by brightness analysis,9–13 which allows for distinguishing the signal of a single protein from the signal of proteins complexes.
However, all these techniques lack temporal resolution since long acquisition times are needed for a good signal-to-noise ratio.11,14–16 To overcome this challenge and access the fast dynamics of molecular assembly, laminar flow microfluidics may be employed. The principle has been demonstrated for, e.g., small angle X-ray scattering17–20 and fluorescence microscopy.21–23 The laminar flow ensures that for each position within the flow channel, the reaction state of the aggregating protein is well-defined and does not change in time, thus long exposures lead to ensemble averaging and improve the statistics of the measurement. The time resolution is given merely by the spatial distance of the measuring positions along the channels and unaffected by the exposure time. A variant of the hydrodynamic flow mixer was established by including a “step” in the central inflow channel for combination with X-ray scattering experiments,19,20,24,25 thereby engulfing the protein jet by a buffer layer and preventing clogging of the channels.
Here, we combine FFS with microfluidics to investigate the assembly of vimentin intermediate filament (IF) protein in a time-resolved manner. IFs, together with microtubules and actin filaments constitute the cytoskeleton of eukaryotes.2 They are expressed in a cell-type specific manner, but all share their secondary structure and hierarchical assembly path.26–29 Vimentin is part of this large family of proteins and expressed in cells of mesenchymal origin.30,31 Assembly occurs in at least two distinct steps: lateral assembly of tetramers – the smallest stable subunit in low-salt buffer, such as 2 mM phosphate buffer (PB) – via octamers and 16-mers to so-called unit length filaments (ULFs) of typically 8 tetramers, followed by longitudinal annealing of these ULFs to extended filaments.26,32–34 The process is sketched in Fig. 1.
![]() | ||
Fig. 1 Schematic representation of vimentin assembly. Vimentin monomers are labeled with Atto-532 via maleimide chemistry and mixed with unlabeled monomers at labeling ratios between 11% and 41%. Upon dialysis against 2 mM of PB, vimentin monomers assemble laterally in a parallel fashion to form dimers and further laterally in half-staggered configuration to tetramers, which are the starting point for our measurements. Upon the addition of KCl, vimentin tetramers continue to assemble laterally resulting in the formation of ULFs, typically composed of 8 tetramers. Subsequently, ULFs anneal end-to-end and form extended filaments. Micrographs of fluorescent vimentin filaments are shown in Fig. S1a and b.† The assembly steps considered in this work are framed by the red box. |
In vitro, assembly is initiated by the addition of salt up to physiological concentrations, such as 100 mM KCl. The time scales of the two assembly steps are distinct: whereas vimentin lateral assembly occurs within less than 1 s,25,35,36 and, as recently reported, on the time scale of 100 ms,37 elongation takes minutes to hours.34,38,39
Our method allows us to determine the increase in label copy number over time, i.e. at different positions of the microfluidic device, and thus follow vimentin assembly, including the two-step process, and precisely determine the time scale of lateral assembly to, on average, 65 ms with a lower bound of 26 ms. More generally, our method allows for studying the influence of reagents, such as multivalent ions or detergents, or of different amounts and types of fluorescent labels on assembly processes.
The device for studying protein assembly combines five inlets and one outlet (device B) with a height of 100 μm and a width of 200 μm for the central inlet channel and a height of 200 μm for the remaining channels. The inlet with reduced height is centered with respect to the full channel height by creating steps (height 50 μm) on the coverslip at the bottom as well as in the polydimethylsiloxane (PDMS) replica forming the channels. To achieve this geometry, two different wafers are produced by photolithography, (i) a five-inlet geometry, master 2, and (ii) the step for the protein inlet (200 μm width and 50 μm thickness), master 3. A schematic of the photolithography steps is shown in Fig. S2.† To create the top step on master 2, a 3D structure is created with two layers of SU8-3050 photo resist (150 μm and 50 μm thick). To improve the uniformity of the first layer, the resist is spin coated twice with a height of 75 μm each. At this point, the resist is soft baked for about 2 hours at 95 °C and exposed to UV-light (MJB4 Mask-Aligner, Süss MicroTec SE, Garching, Germany) through a photomask. After a post exposure bake for 20 minutes at 95 °C, the wafer is spin coated with the second layer of SU8-3050 photo resist (thickness 50 μm). The wafer is soft baked again at 95 °C for 30 minutes and exposed to UV light once more, using a second mask, aligned with the first structure. The wafer is baked for 15 minutes at 95 °C and the photo resist is developed. Master 3 is fabricated by spin coating SU8-3050 to a height of 50 μm and exposed to obtain the 200 μm × 50 μm channel. All masters are coated with (heptafluoropropyl)-trimethylsilane (Sigma-Aldrich, Steinheim, Germany) overnight to allow for easier detachment of the cured PDMS.
PDMS (Sylgard 184, Dow Corning, Midland, MI, USA) replicas are fabricated from the master structures (ratio base:
cross-linker = 10
:
1, 1 hour baking time at 65 °C) and holes for connecting the tubing are punched at the inlet positions (biopsy puncher, 0.75 mm diameter, World Precision Instruments, Sarasota, FL, USA). The top part of the step device is integrated in the PDMS replica stemming from master 2, as shown in Fig. S3c.† For the bottom part, the step is created directly on the glass coverslips (number 1, Thermo Fisher Scientific, Wilmington, DE, USA) using master 3. A PDMS replica of master 3 is placed on top of a clean glass coverslip (Fig. 2a) and a drop of liquid adhesive (Norland Optical Adhesive H83, Norland Products Inc., Cranbury, NJ, USA) is used to create a step by micromolding in capillaries (MIMIC).42 The liquid adhesive fills the channel by capillary forces (Fig. 2b). To speed up the process, the coverslip with the liquid adhesive is placed in a desiccator. The liquid adhesive is then cured by UV light (Fig. 2c) at 365 nm for 3 hours. Afterwards, the PDMS channel is removed (Fig. 2d) and the glue is further cured under UV light for 30 minutes. Both the PDMS channel replica and the glass coverslip with the glue step are cleaned with isopropanol, dried with nitrogen and exposed to air plasma (ZEPTO plasma cleaner, Diener electronic GmbH + Co. KG, Ebhausen, Germany) for 12 seconds at setting 40 W. They are aligned under a stereo microscope (Olympus SZ61, Olympus Europa SE & Co. KG, Hamburg, Germany) and pressed together to form a covalent bond (Fig. 2e). The device is left at 95 °C for about 2 hours to improve the strength of the bond. A photograph of the fully assembled device is shown in Fig. S3a.†
Stationary measurements are performed using 300 μL sample solution placed in an eight-well glass slide (Nunc Lab-Tek Chamber slides, Thermo Fisher Scientific). Flow measurements are performed using the microfluidic device presented in the previous section. Polyethylene tubing (inner diameter 0.38 mm, outer diameter 1.09 mm, Intramedic Clay Adams Brand, Becton Dickinson and Company, Sparks, MD, USA) is connected to 1 mL (for vimentin and PB) or 2.5 mL (for the KCl buffer) glass syringes (Hamilton Gastight, Hamilton Bonaduz AG, Bonaduz, Switzerland) using disposable needles (diameter 0.40 mm, length 20 mm, Sterican, B. Braun AG, Melsungen, Germany). For precise control of the flow, syringe pumps (neMESYS, Cetoni GmbH, Korbußen, Germany) are used to regulate the flow rates of the syringes connected to the inlets. These pumps are particularly suitable for low pressure microfluidic flow. To ensure that our measurements take place exactly at the position of the hydrodynamically focused protein stream, we additionally measure the fluorescence intensity across the channel, perpendicular to the flow direction, and set up our measuring scheme accordingly. To access the different positions in the channel, an automated sample stage (Prior Scientific, Inc., Rockland, MA, USA) is used.
To characterize the microfluidic device and the flow parameters, FEM simulations are performed using Comsol Multiphysics 5.5 with the same flow rates as used for the experiments, i.e., 190 μL h−1 for the side inlets (PB with KCl), 10 μL h−1 for the sheath inlets (PB) and 12 μL h−1 for the central inlet (vimentin tetramer solution), which corresponds to velocities of 1.5 mm s−1, 0.1 mm s−1 and 0.3 mm s−1, respectively. Vimentin tetramers are hydrodynamically focused by the side inlets as shown in the top part of Fig. 3a, where the concentration of vimentin is displayed in the central x–y plane of the device. The assembly of vimentin is initiated, when KCl, which diffuses into the protein stream from the side inlets as shown in the bottom part of Fig. 3a, reaches a concentration of 10 mM.35,38,39 At our chosen flow rates, the reaction threshold of 10 mM KCl (ref. 35) is reached after 110 μm from the end of the central inlet (yellow–black cross in Fig. 3a), thus this channel position is defined as time point t = 0 and position x = 0, as indicated by the vertical dashed line in Fig. 3d. The salt concentration in the center of the outlet channel increases, as shown in Fig. 3d (blue curve). As a direct consequence of the five inlets merging into one outlet, the velocity is not constant along the entire device, but it increases for the first 250 μm after the channel intersection, as shown in Fig. 3d, red curve. Afterwards, a constant velocity of 5.7 mm s−1 is reached. Therefore, the calculated reaction time, shown in the inset of Fig. 3d, initially is not spaced uniformly with the channel positions.
To prevent clogging of the channels by aggregates adsorbed to the channel walls, a reduction in height of the protein inlet leading to a step is employed.19,24,25 The ability of the step in the central inlet to keep vimentin from touching the channel walls is demonstrated in the x–z central plane of the cross section, as shown in Fig. 3b where the vimentin and KCl concentrations are shown in the top and the bottom part, respectively. The red arrow in the top part of Fig. 3b marks a vimentin concentration of zero at the upper channel wall. Furthermore, all flow lines for vimentin tetramers expand in z-direction (Fig. 3c) after entering the cross section, i.e. behind the step, without reaching the channel wall. We confirm by epi-fluorescence microscopy that no protein aggregates at the channel walls. The flow velocities chosen here ensure that the assembling protein stays distant from the channel walls. As a consequence of the comparatively high flow rates, diffusion and convective flow are overlaid and FCS cannot be employed to measure diffusion. We introduce the flow time , defined as the ratio between the beam waist w0 and the flow velocity v, and the diffusion time
with the diffusion coefficient D to evaluate the two types of molecular motion.7 As a first approximation, τF has to be at least equal to τD to allow for measuring diffusion using FCS. If vimentin tetramers are considered, τD = 937.5 μs, with w0 = 300 nm for our setup and D = 24 μm2 s−1. As a consequence, the maximum possible total flow velocity in the center of the device is ≈ 0.3 mm s−1, which is too slow for the step geometry to come into effect, see Fig. S4.† It was further demonstrated that already at
, flow dominates over diffusion55 and consequently FCS cannot be employed to measure the dynamic of vimentin assembly. We thus refrain from using FCS to study vimentin assembly in flow.
To establish PCH as a valid method for our purpose, we first perform measurements on vimentin tetramers with labeling ratios of 22% and 36% at different protein concentrations without convective flow. The results are shown in Fig. 4a, and the fitting parameters are summarized in Table 1.
![]() | ||
Fig. 4 PCHs of vimentin tetramers with and without flow. a) PCHs of vimentin tetramers at different protein concentrations and different labeling ratios measured in bulk. The symbols represent the experimental data and the solid lines the fits to a one-component model. For each PCH curve, the brightness B and the average number N of fluorescent objects in the observation volume is retrieved. The measured brightness values are comparable at the different concentrations, whereas the average numbers of molecules scale roughly as the concentrations, as summarized in Table 1. b) PCHs of vimentin tetramers in microfluidic device A fabricated from master 1 (a single straight channel) at different velocities. The PCHs coincide for all velocities confirming the independence of PCH from the flow velocity. The parameters B and N obtained from the fitting are in agreement (see table, inset top right). Photon counts are acquired for 300 s for each PCH data set. |
LR (%) | c vim (g L−1) | B (kcps) | N PCH |
---|---|---|---|
22 | 0.0017 | 96 ± 3 | 1.36 ± 0.08 |
22 | 0.0002 | 100 ± 1 | 0.14 ± 0.02 |
36 | 0.0009 | 104 ± 2 | 1.01 ± 0.04 |
36 | 0.0001 | 100 ± 2 | 0.14 ± 0.04 |
As expected, the brightness is independent of the protein concentration, confirming the reliability of PCH to quantify the brightness of vimentin tetramers. Between the two labeling ratios, the brightness is similar since the average number of fluorophores per vimentin tetramer is almost identical for both labeling ratios, i.e. 1.4 for 22% and 1.6 for 36%. Note that, intrinsic to our study design, each monomer is either labeled or unlabeled and a tetramer, which represents the smallest stable supermolecular assembly, may contain either 0, 1, 2, 3 or 4 fluorophores. When directly comparing the PCH results to FCS data of the same sample (see Fig. S5 and Table S1†) we obtain agreeing values for the average number of fluorescently labeled objects in the observation volume (NFCS = NPCH).
The independence of PCH from the convective flow55 is confirmed by measuring vimentin tetramers at different flow velocities inside microfluidic device A, which consist of a simple straight channel. At the aspect ratio of device A (height:
width = 1
:
10), the velocity shows a plug flow profile. Therefore, the velocity is constant along the width of the channel, assuring that all vimentin tetramers in the same z plane move through the observation volume with the same flow velocity. Using device A, no changes in number concentration, e.g. by dilution or assembly, or in brightness are expected, thus the PCHs at different velocities should all be the same, as long as undersampling is avoided. Vimentin tetramers with a concentration of 0.005 g L−1 and a labeling ratio of 3.8%, thus corresponding to a molar dye concentration of 3.5 nM in the solution, are measured at four different velocities (2 mm s−1, 6 mm s−1, 10 mm s−1 and 20 mm s−1). As shown in Fig. 4b the four PCHs all fall on top of each other confirming the independence of PCH from the flow velocity.55 Moreover, the parameters obtained from the PCH fits, N and B at the four velocities are in agreement with each other as shown in the inset table in Fig. 4b. The variability of the fitting parameters is typical for this type of analysis in flow.55,57
The temporal evolution of the label copy number of vimentin, which is obtained by dividing the measured brightness by the brightness of a single molecule of Atto-532, can be compared to the expected label copy number of differently-sized vimentin assemblies. To calculate the expected average number of labels per vimentin assembly (n-mer) we take advantage of the binomial distribution:
![]() | (1) |
In a first experiment, to bench mark device B, we do not inject assembly buffer from the side inlets, but just 2 mM PB, pH 7.5, and thus do no initiate assembly, see Fig. 5a. As expected, the brightness as well as the label copy number are constant in time, with an average value of 1.6 ± 0.4 labels per subunit. The brightness of a molecule of Atto-532 is (54 ± 20) kcps, which is measured in a separate experiment performed with the same optical alignment. The average measured label copy number corresponds to the expected value for vimentin tetramers at this particular labeling ratio, 1.9, which is graphically represented by the lowest gray dashed line in Fig. 5a. This confirms that vimentin remains in the tetrameric state when no salt is added and that the in-flow measurements on vimentin tetramers are valid.
Once the assembly buffer is injected from the side inlets, we expect the brightness to increase over time, as during assembly vimentin tetramers associate and form larger subunits. According to the times scales accessible with our microfluidic device, i.e. up to 4.1 s, we focus on the lateral assembly of vimentin tetramers into ULFs. Elongation into extended filaments occurs on longer time scales, i.e. on the order of minutes.37–39,58Fig. 5b shows the brightness and the label copy number plotted against time for a sample of vimentin tetramers with a labeling ratio of 24%. As expected, the brightness increases with time, confirming the assembly of vimentin. At t = 0 s, we observe a label copy number of 2 ± 1, in good agreement with the calculated value for tetramers of 1.5. To quantify the time needed for ULF formation, an exponential growth function with time constant τULF is fitted to the brightness, which is graphically shown as the red dashed line in Fig. 5b. At this labeling ratio, ULFs are formed on a time scale of τULF = (45 ± 10) ms. Note that the error bars of the fitted brightness indicate not only the variability in the assembly dynamics, which might be caused by uncertainties in the flow profile, but mostly the difference in the number of fluorescent labels for each measured vimentin assembly. In principle, a ULF could contain from 1 up to 32 Atto-532 molecules, when each tetramer is labeled with 4 Atto-532 molecules.
When vimentin tetramers with a lower labeling ratio are assembled, the formation of ULFs is faster, as shown in Fig. 5c, where at a labeling ratio of 11%, a time constant of (26 ± 5) ms is obtained by the exponential growth fit. Once the ULFs are formed, the brightness is constant. This is a further demonstration of the two-step process of vimentin assembly: the lateral assembly, which occurs in the first 100 ms is clearly separated from the filament elongation on longer time scales.37,38,44,58 In this example, the brightness at t = 0 s is (41 ± 8) kcps, which is in agreement with the bulk measurement of the same vimentin tetrameric sample (B = (40 ± 5) kcps). The label copy number per vimentin subunit, see cyan diamonds in Fig. 5c, increases with time, starting from a value of 1.2 ± 0.2, which corresponds to the expected value for tetramers (1.2), up to a value of 4.5 ± 0.5, in agreement with the expected value for ULFs (4).
At this comparatively low labeling ratio (11%), the measured label copy number reflects the calculated copy number very accurately. However at higher labeling ratios the measured copy number tends to be lower than the expected values, as shown, for example, in Fig. 5b. In this case, the experimental number of labels per ULF is, on average, 6.3 ± 0.3 while the expected value is 7.5 at a labeling ratio of 24%. The discrepancy at higher labeling ratio might be caused by an effective lower brightness induced by self-quenching of the fluorophores within the ULF. In particular, at a labeling ratio of 24%, on average, 3.5 dye molecules are attached to the tails of vimentin monomers at each side of a single ULF, which has a diameter of 17 nm. Thus, on average, the dye molecules are separated from each other by a distance of 4.8 nm, which is small enough to see quenching effects.59
It has previously been reported that vimentin assembly is influenced by the labeling ratio.44 In fact, as shown in Fig. S1c,† when only labeled vimentin monomers are assembled without the addition of unlabeled protein, filaments are not formed at all. Thus, it is not surprising that vimentin assembles faster at a labeling ratio of 11%, τULF = 26 ms, compared to a labeling ratio of 24%, where the time scale for ULF formation τULF is 45 ms. At higher labeling ratios, the lateral assembly of vimentin is even slower, with τULF = 109 ms measured at a labeling ratio of 40%, as shown in Fig. S6.† In general, a trend of longer lateral assembly time for higher labeling ratios is found within our measured labeling ratios. We assume that at high labeling ratio the lateral assembly is slowed down because the fluorophores interfere with the interaction between two vimentin subunits. On the one hand, this effect might be due to steric hindrance, on the other hand, electrostatic or hydrophobic interactions between the fluorophore and the protein may play a role. Our setup could indeed be used to systematically study the influence of charges and hydrophobic groups carried by varying fluorophores.
If we consider all labeling ratios (varying from 11% to 40%) measured in 9 different experiments, on average we obtain an assembly time scale from tetramers to ULFs of 65 ms, which is in very good agreement with the value of 100 ms measured by static light scattering.37 Mücke et al. measure a peak of the 8mer signal after 7 ms, a peak of the 16mer signal at 66 ms and the signal of ULFs (32 mers) starting from 50 ms. At low labeling ratio, we obtain 8mers after 10 ms, 16 mers after 43 ms and ULFs after 54 ms, thus very much in agreement with the earlier study. The light scattering experiments on unlabeled protein employed a stopped-flow setup to start the assembly. Thus, the mixing strategy differs from our approach. With diffusive mixing, once the assembly is initiated, the positions in the channel can be translated into the time coordinates of the reaction with almost no dead time. However, due to the finite size of the vimentin central stream, uncertainties on the mixing time need to be taken into consideration. Considering the flow rates in our system, the focused vimentin stream has a width of 6 μm, thus the diffusion time of the KCl into the vimentin stream is on the order of 2.5 ms. By contrast, in the stopped-flow measurements, a defined starting point of the assembly process is achieved by turbulent mixing, which, however, introduces a dead time of about 10 ms. Thus, diffusive mixing is comparable to in vitro assembly via dialysis and stopped-flow relates to a “kick start” approach, which might lead to heterogeneities in the assembled vimentin subunits.26,37 In combination with slightly different buffer conditions, small differences in the results can be explained. Overall, both approaches, stopped-flow combined with light scattering and diffusive mixing combined with PCH, are complementary, and the results agree very well.
As the brightness increases, the average number of fluorescent objects in the observation volume, N, decreases, as shown in Fig. 5d. While the increase in brightness, B, can be entirely attributed to the assembly, the decrease of N is caused partly by the assembly and partly by the dilution of the protein stream by the injected buffer from the other inlets. To quantify the temporal evolution of N, we fit the data by an exponential decay. The average number of fluorescent objects in the observation volume decays consistently in different experiments, see orange and green data points in Fig. 5d. The time constants retrieved from the fits are comparable, confirming the reproducibility of our experiments.
All PCHs for vimentin molecules in the step device are analyzed by a two-component fit. The first component corresponds to the data shown in Fig. 5. The second component shows a constant brightness along the channel, as shown in Fig. S7a,† with a value 3 times higher than the expected brightness for ULFs. As is it also present when using the step device on vimentin without assembly buffer injected into the side channels (see, e.g.Fig. 5a), we can exclude that it is due to the assembly reaction. As it is present for flow in channels without the step, we assume it is also not due to the specific channel geometry. Moreover, the second component is not present in PCH measurements in flow of pure dyes, such as rhodamine 6G or Alexa-532 in flow or in vimentin samples measured in bulk at low protein concentrations. We speculate that it could be due to rare large and disordered protein aggregates present even before assembly, as also found by others.37–39 The average number of fluorescent objects in the observation volume for this second component is at least 20 times smaller than the values for the first component, as shown in Fig. S7b.† However, the second component does not compromise our measurements, since the brightness of this second component is very different from the brightness of vimentin assemblies.
With our approach, we are able to resolve the very first time points of assembly, as the lag time needed for mixing is below 3 ms and we clearly confirm that vimentin assembly is a two step process. We determine the time scales for the lateral assembly to be on the order of 65 ms, with a trend for slower assembly when more protein is labeled. Our approach can be generalized to study other biological and soft matter (self-)assembly processes, with a wide range of applications ranging from physiological assembly as in cytoskeletal structures to pathological aggregation processes like α-synuclein aggregation.
Footnote |
† Electronic supplementary information (ESI) available: Additional data and detailed methods. See DOI: 10.1039/d0lc00985g |
This journal is © The Royal Society of Chemistry 2021 |