Open Access Article
Ku Sun
Choung
,
Karen
Marroquin
and
Thomas S.
Teets
*
University of Houston, Department of Chemistry, 3585 Cullen Blvd., Room 112, Houston, TX 77204-5003, USA. E-mail: tteets@uh.edu
First published on 15th April 2019
Here we introduce a new class of ratiometric O2 sensors for hypoxic environments. Two-component structures composed of phosphorescent cyclometalated Ir(III) complexes and the well-known organic fluorophore BODIPY have been prepared by the 1
:
1 reaction of bis-cyclometalated iridium synthons with pyridyl-substituted BODIPY compounds. Two different cyclometalating ligands are used, which determine the relative energies of the iridium-centered and BODIPY-centered excited states, and the nature of the linker between iridium and BODIPY also has a small influence on the photoluminescence. Some of the conjugates exhibit dual emission, with significant phosphorescence from the iridium site and fluorescence from the BODIPY, and thus function as ratiometric oxygen sensors. Oxygen quenching experiments demonstrate that as O2 is added the phosphorescence is quenched while the fluorescence is unaffected, with dynamic ranges that are well suited for hypoxic sensing (pO2 < 160 mmHg).
Conventional designs for ratiometric oxygen sensors partner a fluorescent molecule or nanomaterial with a molecular phosphor; in the presence of O2 phosphorescence is quenched whereas fluorescence is unaffected. A schematic of this sensing mechanism is summarized in Fig. 1. The diagram in Fig. 1 assumes fluorophore emission which is higher energy (bluer) than the phosphor emission, but the opposite configuration is also possible, provided energy transfer from the phosphor to fluorophore can be minimized. Excitation of the construct could then be followed by energy transfer between the components, although in many cases energy transfer from the fluorophore to the phosphor is minimal, given the short lifetime of the fluorophore. Nevertheless, if both sites can be excited simultaneously, in the absence of O2 fluorescence and phosphorescence from the respective sites occur. When O2 is added, the triplet excited state of the phosphor is quenched, reducing the phosphorescence signal. Important criteria for effective sensor design include fluorescence and phosphorescence wavelengths that are far enough apart to be resolved, and minimal energy transfer between the two components to ensure that both emission signals are observed. Along these lines, recently reported designs for ratiometric O2 sensors include quantum dots decorated with phosphorescent metal complexes,12 metal–organic frameworks with both fluorescent and phosphorescent linkers,13 fluorescent polymers with covalently linked cyclometalated iridium complexes,14 and phosphorescent cyclometalated iridium complexes tethered to coumarin fluorophores.5 Other relevant designs feature platinum porphyrin phosphors, either physically embedded into15 polymer beads along with a naphthalamide fluorophore, or covalently attached to fluorescent polymers.16 In addition to organometallic and organic luminophores, lanthanide ions, which emit from metal-centered excited states, have been incorporated into ratiometric luminescent oxygen sensors.17 Cyclometalated iridium complexes are especially attractive as the phosphorescent component, offering a combination of color tunability, high photoluminescence quantum yield, and relatively long (ca. μs) lifetimes not found in any other class of molecular phosphor. These attributes of cyclometalated iridium(III) complexes have been outlined in many recent studies18–27 and have made these compounds prime candidates for a number of optoelectronic applications, including organic light emitting diodes (OLEDs)28–31 as phosphorescent chemosensors,32–44 and singlet oxygen (1O2) sensitizers.45–52
Despite their potential advantages, there are comparatively few reports using cyclometalated iridium complexes in ratiometric O2 sensors. One recent design which functioned well for intracellular oxygen sensing pairs a red-emitting cyclometalated iridium phosphor with a blue-emitting coumarin fluorophore, tethered to one another via a biologically compatible tetraproline linker.5 The complex linker was needed to minimize energy transfer between the components and allow simultaneous detection of both emission signals. Although this construct was ultimately effective as a ratiometric oxygen probe, synthesis of this sensor required at least 10 steps to prepare the fluorophore/linker construct, which was then coupled to the cyclometalated iridium fragment in 19% yield. There are some known constructs which combine bis-cyclometalated iridium complexes with BODIPY fluorophores,53–58 offering the advantages of BODIPY's high fluorescence quantum yields and biological compatibility,59–62 but these have not been developed as ratiometric oxygen sensors. Inspired by this previous work, here we introduce a class of ratiometric sensors prepared by a simple, modular approach, offering rapid access to several sensors with a range of emission profiles and ratiometric responses. These constructs pair bis-cyclometalated iridium fragments with BODIPY fluorophores, joined via variable pyridine-based linkers. The BODIPY and iridium precursors are each prepared in 1–3 steps from commercial precursors, and can be coupled to one another in yields ranging from 52% to 93%. This improved synthesis is enabled by a highly reactive cyclometalated iridium synthon recently disclosed by our group, and it is very easy to control the phosphorescence color by changing the cyclometalating ligand. Furthermore, the linker between the iridium and BODIPY influences the extent of energy transfer between the components, providing additional control over the photoluminescence output. By varying the cyclometalating ligand and linker it is possible to engender some of these compounds with dual luminescence. These dual-emitting compounds function effectively as ratiometric sensors for hypoxic environments, with high sensitivity and a large dynamic range for measuring oxygen partial pressure in abiological medium.
The structures of the [Ir(F2ppy)(CNArdmp)(BODIPY)](PF6) complexes 6a–8a were ascertained by single-crystal X-ray diffraction‡ and are shown in Fig. 2. Diffraction data and refinement details for complexes 6a–8a are summarized in Table S1 of the ESI.† The X-ray structures verify that the BODIPY attaches to the iridium center through a covalent bond with Ir–Npyridyl distances ranging from 2.173(5) Å to 2.222(8) Å. The nature of the linker between the iridium and the BODIPY has measurable effects on the relative orientation of the two components. The internuclear distance between the iridium and boron atoms are similar for 6a (9.38(1) Å, average of two independent molecules) and methylene-spaced 8a (9.140(6) Å), whereas the additional phenyl spacer in 7a results in a substantially longer distance of 13.73(1) Å. The alignment of the BODIPY relative to the iridium fragment also differs considerably in the three structures, as measured by the dihedral angle between the mean plane of the BODIPY and the mean plane of the F2ppy ligand trans to the BODIPY pyridyl. In complex 7a this angle is 7.2°, indicating a nearly parallel arrangement of the BODIPY, and it increases to 21.1° in 6a (average of two crystallographically independent molecules), and with the sp3 linker in 8a the angle is 73.9°.
![]() | ||
| Fig. 2 X-ray crystal structures of complex 6a–8a. Ellipsoids are drawn at the 50% probability level with counterions, solvent molecules, and hydrogen atoms omitted. | ||
The identities of [Ir(C^N)2(CNArdmp)(BODIPY)](PF6) complexes 6–8 were also confirmed by high resolution mass spectrometry (ESI), which clearly show the 1
:
1 combination of the bis-cyclometalated iridium fragment with the pyridyl-substituted BODIPY in each case. For each compound a strong molecular ion peak was located, the mass being a good match for the corresponding [M–PF6]+ ion. Fig. S27–S32 of the ESI† show the experimental data for the [M–PF6]+ ion juxtaposed with the simulated pattern. In each case, the isotope peaks are separated by 1 m/z unit, confirming the +1 charge of the ion, and there is a good match between the experimental and simulated isotopologue ratios. To summarize the characterization of the Ir–BODIPY constructs, the combination of X-ray crystallography and HRMS confirms the identity of the compounds, whereas multinuclear NMR validates their bulk purity.
000 M−1 cm−1) and λmax = 503 nm (ε = 82
000 M−1 cm−1) for 3 and 4, respectively. The absorption coefficient of methylene-spaced 5 (ε = 96
000 M−1 cm−1) at λmax (506 nm) is slightly larger than that of the analogues with aromatic spacers. All of organic chromophores 3–5 are fluorescent at room temperature, and the steady-state and time-resolved emission data are summarized in Table S2 of the ESI.† All three pyridyl-BODPYS have similar photoluminescence spectra, the notable difference being the quantum yields, which for methylene-spaced 5 is observed to be 0.99, compared to 0.30 (3) and 0.43 (4) for the aromatic pyridyl-BODIPYs. This exceptionally high quantum yield for complex 5 has also been observed in other solvents such as toluene (ΦPL = 1.0) and ethanol (ΦPL = 0.89), as well as in other BODIPYs with substituted benzyl substituents at the meso position.66 The fluorescence lifetimes for all of the free BODIPYs are in the ns range, with a slightly longer value for 5 (6.6 ns) when compared with 3 and 4 (1.9 and 2.7 ns, respectively). The free BODIPY compounds all have nearly identical radiative rate constants (kr), so the larger quantum yield and longer lifetime in 5 is attributed to a much smaller nonradiative rate constant (knr, see data in Table S2†). It has been established that knr is strongly influenced by rotation of the meso substituent, suggesting that the methylene-spaced substituent in 5 is more rigid than the aromatic groups in 3 and 4.
The UV-vis absorption spectra of all Ir–BODIPY conjugates 6–8 measured at room temperature in dichloromethane are shown in Fig. 3 and summarized in Table S3 of the ESI.† The UV-vis absorption spectra of the Ir–BODIPY constructs are dominated in the visible region by strong bands in the range of 504–510 nm originating from the BODIPY. The wavelengths of these visible absorption bands are very similar to the free BODIPYs, but the molar absorptivities (ε) are attenuated to a significant extent, especially in the piq series. The large attenuation of ε in the piq series is reproducible over multiple samples, though the origin is not clear. Such an effect has not been previously observed in other 5d metal complexes linked to BODIPY through the meso position.54,68–72 The UV and near-visible regions involve several overlapping bands, attributed to a combination of π → π* transitions involving the BODIPY (compare to Fig. S19†), and the expected bands73 from the [Ir(C^N)2]+ fragment that include C^N-centered π → π* transitions at higher energy and MLCT transitions at lower energy.
Overlaid photoluminescence spectra of complexes 6–8 are displayed in Fig. 4, and the data is summarized in Table 1. The spectra are excitation-wavelength dependent, and with 475 nm excitation, where only the BODIPY is expected to absorb, only fluorescence coming from the BODIPY fragment is observed. In most cases the fluorescence wavelength is nearly identical to the respective free BODIPY. However in complex 6a, where the [Ir(F2ppy)2(CNArdmp)]+ fragment is linked to the BODIPY via a short pyridyl spacer, the BODIPY fluorescence is significantly red-shifted to 549 nm, and while not as pronounced the fluorescence in the piq complex with the same linker (6b) red-shifts to 528 nm. This measurable red shift of the fluorescence upon coordination to iridium is similar to the effect we observed previously when Lewis acidic boranes were coordinated to BODIPY 3.65 Lifetimes for the fluorescence component are quite similar to the free BODIPYs 3–5 (Table S2†). In most cases the fluorescence quantum yields, determined when the BODIPY is selectively excited at 475 nm, are significantly lower than the free BODIPY and range from 7.4–66% across the series of compounds.
| λ em/nma | λ em/nmb | Φ PL | Φ PL | τ/nsd | τ/μse | |
|---|---|---|---|---|---|---|
| a Fluorescence only, excited at 475 nm. b Fluorescence and phosphorescence excited at 310 nm. c No phosphorescence for this compound. d Fluorescence lifetimes, excited at 455 nm. e Phosphorescence lifetime, excited at 330 nm. | ||||||
| 6a | 549 | 438, 465, 550 | 0.074 | 0.060 | 1.4 | 6.8 |
| 7a | 517 | 448, 472(sh), 521 | 0.30 | 0.13 | 2.7 | 5.6 |
| 8a | 516 | 517c | 0.66 | 0.65 | 5.2 | N.D.c |
| 6b | 528 | 527, 585(sh), 621 | 0.089 | 0.041 | 2.5 | 6.0 |
| 7b | 521 | 520, 576, 620 | 0.16 | 0.063 | 1.5 | 6.9 |
| 8b | 518 | 515, 574, 619 | 0.13 | 0.052 | 5.2 | 7.3 |
In contrast, with 310 nm excitation, where both the iridium phosphor and the BODIPY fluorophore absorb, two emission bands are observed in most cases. Iridium-centered phosphorescence, with wavelengths that depend on the identity of the cyclometalating ligand, is observed in addition to the BODIPY-centered fluorescence. This vibronically structured band occurs with λmax at ca. 440 and 467 nm in F2ppy complexes 6a and 7a, and λmax at ca. 575 and 623 nm for piq complexes 6b–8b. No phosphorescence is observed in complex 8a, where C^N = F2ppy and the BODIPY includes a methylene spacer, suggesting that in this case there is efficient energy transfer from the [Ir(F2ppy)2]2+ fragment to the BODIPY, and only BODIPY-centered fluorescence is observed at either excitation wavelength. The more efficient energy transfer in 8a seems to indicate that energy transfer does not involve electronic coupling through the meso position, which is expected to be minimal in 8a given the unconjugated linker. Thus the slight differences in energy transfer in 6a–8a are likely a function of the different spatial arrangements of the BODIPY acceptor relative to the iridium donor, as observed crystallographically in the solid state (see above). Energy transfer from BODIPY to Ir does not appear to occur, since the red phosphorescence in piq complexes 6b–8b is only observed when the Ir center is excited directly, and does not occur when only the BODIPY is excited at 475 nm. The photoluminescence quantum yields (ΦPL) of the Ir–BODIPY conjugates tend to be somewhat lower when both the Ir and the BODIPY are simultaneously excited at 310 nm, ranging between 6.0 and 65%. The one exception is complex 8a, which only exhibits fluorescence at both excitation wavelengths and has the same quantum yield in each case, again consistent with efficient energy transfer from Ir to BODIPY for this compound. For the rest of the compounds, the wavelength-dependence of the quantum yield suggests that phosphorescence from the iridium center is inherently less efficient than fluorescence from the BODIPY. In 6a and 7a it is difficult to evaluate whether excited-state energy transfer between the [Ir(F2ppy)2]2+ center and the BODIPY is occurring, though we presume there is some degree of energy transfer since the phosphorescence quantum yield in these compounds is much lower than we typically observe for isocyanide-bound [Ir(F2ppy)2]+ complexes.73,74 The phosphorescence lifetimes of all complexes (except 8a, which doesn't phosphoresce) fall in the narrow range of 5.6–7.3 μs.
The apparent dual emission with UV excitation persists and is identical in samples of the Ir–BODIPY complexes that have been purified multiple times by silica gel column chromatography and recrystallization, suggesting it is not a result of minor impurities. In addition, the excitation spectra for 6–8 (Fig. S21–S26†) overlay very well with the UV-vis absorption, indicating that both emission bands arise from the Ir–BODIPY conjugate. These investigations suggest that the orientation of the BODIPY chromophore relative to the iridium center, controlled by the nature of the linker between the fluorophore component and phosphor fragment, can play a role in the energy-transfer dynamics and photoluminescence properties. In general when C^N = F2ppy energy transfer can occur such that predominantly BODIPY fluorescence is observed, whereas when C^N = piq there is minimal energy transfer and dual emission occurs when both sites are excited. The relative amounts of phosphorescence and fluorescence do vary somewhat across the series as a function of the linker, although the ratio of phosphorescence to fluorescence is also excitation-wavelength dependent.
To more quantitatively evaluate the sensing response, photoluminescence measurements were carried out at varying pO2 levels, until the point when the phosphorescence signal no longer changed appreciably. These results are summarized in Fig. 5, which shows the spectral evolution for each compound as pO2 is gradually increased. All four of the complexes are able to sense low levels of oxygen below atmospheric content (pO2 ≤ 160 mmHg), indicating they are suitable for hypoxic environments. The right-hand plots of Fig. 5 (blue circles) show the sensing response plotted as the ratio of phosphorescence to fluorescence signal, determined from the intensities at the respective maxima, vs. pO2. These plots demonstrate that the ratiometric response spans a >3-fold range in each case, i.e. the signal ratio changes by more than a factor of three over the range of pO2 values tested.
To gain further insight into the oxygen sensing response, Stern–Volmer analysis on the phosphorescence lifetime was conducted. Eqn (1) shows the Stern–Volmer relationship,75,76 where Ksv is the Stern–Volmer constant, pO2 is the oxygen partial pressure, kq is the quenching rate constant, and τ0 and τ are the lifetimes in the absence and presence of oxygen, respectively.
![]() | (1) |
The Stern–Volmer plots and linear fits are overlaid with the ratiometric sensing data in in Fig. 5, and the Stern–Volmer parameters extracted from this data are summarized in Table 2. The Stern–Volmer constant Ksv can be obtained from the slope of the linear fit. Also, the quenching rate constant kq can be determined by using Ksv and τ0. The Stern–Volmer constants (Ksv) for bis-cyclometalated iridium–BODIPY complexes 6a, and 6b–8b were determined to be 3.0–8.1 × 10−2 mmHg−1, and from these values quenching rate constants (kq) were determined to vary from 4.4 × 103 s−1 mmHg−1 to 1.2 × 104 s−1 mmHg−1. To convert the unit of the quenching rate constant to s−1 M−1, which is more conventional for bimolecular quenching rate constants, we adopted the previously reported literature77 regarding to the solubility of oxygen into organic solvents. The solubility value of oxygen into dichloromethane at 298.2 K and 101.33 kPa (1 atm) is 7.09 × 10−4 M, and using this conversion factor kq ranges from 4.7 × 109 s−1 M−1 to 1.3 × 1010 s−1 M−1 in the four Ir–BODIPY conjugates evaluated as sensors. To contextualize these results, we see that all four sensors presented here are efficiently quenched by O2, with kq values approaching the diffusion limit. The Stern–Volmer kinetics seem to depend slightly on the C^N ligand, with the complexes in the piq series (6b–8b) quenching more efficiently than F2ppy complex 6a. For 6b–8b there are slight differences in Stern–Volmer parameters, indicating there may be a small dependence on the nature of the BODIPY spacer, but all three behave quite similarly overall. Comparing to previously described ratiometric oxygen sensors, the KSV values for the Ir–BODIPY constructs described here are larger than those of a recently described MOF-based nanosensor13 and a platinum porphyrin polymer sensor,16 both of which have Ksv = 1.7 × 10−2 mmHg−1, and comparable to a cyclometalated iridium-coumarin sensor with Ksv = 6.4 × 10−2 mmHg−1.5 Comparing to sensors with reported quenching rate constants, the complexes described here have kq values that exceed those of a nanocrystal sensor decorated with osmium phosphors (kq = 1.8 × 109 s−1 M−1)12 and protoporphyrin IX (kq = 4.0 × 102 s−1 mmHg−1),78 which functions as an endogenous turn-off O2 sensor. These comparisons demonstrate that the new ratiometric oxygen sensors described here compare favorably with well-known examples of biological oxygen sensors, with good sensitivity (kq up to 1.3 × 1010 s−1 M−1) and dynamic ranges suitable for hypoxic measurements (<160 mmHg).79,80
| Entry | K sv/mmHg−1 | k q/s−1 mmHg−1 | k q/s−1 M−1 |
|---|---|---|---|
| 6a | 3.0 × 10−2 | 4.4 × 103 | 4.7 × 109 |
| 6b | 5.0 × 10−2 | 8.3 × 103 | 8.9 × 109 |
| 7b | 8.1 × 10−2 | 1.2 × 104 | 1.3 × 1010 |
| 8b | 6.4 × 10−2 | 8.8 × 103 | 9.4 × 109 |
:
4 v/v) to get the desired product, which was further purified by recrystallization (dichloromethane/hexane).
:
4 (v/v) ethyl acetate/CH2Cl2 as the eluent, followed by recrystallization (dichloromethane/hexane).
Footnotes |
| † Electronic supplementary information (ESI) available: Crystallographic summary tables, NMR spectra for all new compounds, additional UV-vis absorption data, high-resolution mass spec data, and additional photoluminescence spectra. CCDC 1883526–1883528. For ESI and crystallographic data in CIF or other electronic format see DOI: 10.1039/c9sc00696f |
‡ 6a: CCDC 1883526, C49H39BF12IrN6P, M = 1173.84, monoclinic, P21/c, a = 18.512(5) Å, b = 18.686(5) Å, c = 32.097(8) Å; β = 91.307(3)°, Z = 8, 56 882 tot. refln., 23 916 ind. refln., Rint = 0.055, R1 = 0.076, wR2 = 0.242. 7a·1.5CH2Cl2: CCDC 1883527, C56.50H46BCl3F12IrN6P, M = 1377.32, triclinic, 1, a = 10.868(3) Å, b = 14.021(3) Å, c = 20.638(5) Å; α = 105.005(3), β = 92.613(3)°, γ = 95.539(3), Z = 2, 16 782 tot. refln., 12 744 ind. refln., Rint = 0.020, R1 = 0.084, wR2 = 0.311. 8a·CH2Cl2: CCDC 1883528, C51H43BCl2F12IrN6P, M = 1272.79, monoclinic, C2/c, a = 45.386(6) Å, b = 11.4399(14) Å, c = 20.573(3) Å; β = 102.781(1)°, Z = 8, 54 925 tot. refln., 11 935 ind. refln., Rint = 0.025, R1 = 0.062, wR2 = 0.154. |
| This journal is © The Royal Society of Chemistry 2019 |