Open Access Article
Shuoran Chen
a,
Fuming Chena,
Pengju Han
*a,
Changqing Ye
*a,
Suqin Huanga,
Lei Xua,
Xiaomei Wanga and
Yanlin Song
b
aResearch Centre for Green Printing Nanophotonic Materials, Jiangsu Key Laboratory for Environmental Functional Materials, Institute of Chemistry, Biology and Materials Engineering, Suzhou University of Science and Technology, Suzhou 215009, P. R. China. E-mail: yechangqing@mail.usts.edu.cn
bKey Laboratory of Green Printing, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China
First published on 8th November 2019
A ratiometric fluorescent sensor for the detection of Fe3+ ions is achieved based on triplet–triplet annihilation upconversion (TTA-UC) luminescence. A new anthracene derivative (named as DHTPA) is designed and synthesized and reveals similar optical properties to 9,10-diphenylanthracene (DPA) and is used as a stimuli responsive annihilator in a TTA-UC system due to its complexation ability. As a result, the UC emission can be significantly quenched by Fe3+ ions, while the phosphorescence (PL) emission of sensitizer palladium(II) octaetylporphyrin (PdOEP) remains nearly constant, which makes the PL signal an appropriate internal reference for the UC signal. The UC and ratio signals (IUC/IPL) both reveal a good linear relationship with Fe3+ ion concentration, which for the first time makes the TTA-UC system a perfect ratiometric sensor for Fe3+ ion detection. This sensing method will open a novel avenue to achieve ratiometric sensors in chemical and biological fields.
Among all the reported strategies on Fe3+ detection including electrochemical process,12 atomic absorption spectrometry,13 nanosensors14 and fluorescent spectrometry,15 molecular fluorescent probes have attracted great research attention due to their high simplicity, selectivity, sensitivity and response rate. Selective weak interaction or complexation may occur between molecular probes and Fe3+ ions, leading to the change of molecular structure of the probes and the corresponding varying of the fluorescent signals (e.g. fluorescence intensity, shift or lifetime).16
In the past decades, considerable efforts have been devoted to the development of fluorescent probes for Fe3+ ions.17 The majority of the reported probes are based on traditional down-converting fluorescence of dyes excited under UV or visible irradiation,18 which have drawbacks including low media penetration and potential harm to human health. Besides, autofluorescence derived from fluorescent proteins19 or other biological fluorescein20 in the biological samples will in turn interfere the detection signals of the probes.21 Whereas, all above issues can be solved by using photoluminescent probes based on frequency upconversion (UC),22 which is a process converting low energy photons to higher ones. The long wavelength excitation brings good penetrability, which makes UC a useful probe in many complicated application environments. Besides, it can avoid the harm from common UV excitation irradiation, either to organism or chromophore structure.23 Among all the present mechanisms of UC, triplet–triplet annihilation upconversion (TTA-UC) has drawn widely research interests due to its relatively higher (>10%) quantum yield (QY) and lower (<10 mW cm−2) threshold excitation intensity (Ith).24 Particularly, TTA-UC is a double-dye system consisting of triplet sensitizers and annihilators, which may simultaneously cause two photoluminescent emissions from the two kinds of dyes. Briefly, when exciting light of specific wavelength irradiating the TTA-UC system, the UC luminescence through a triplet–triplet energy transfer (TTET) process from sensitizer to annihilator and the phosphorescence luminescence (PL) of sensitizer itself occur at the same time.25 Interestingly, the UC and PL signals may show different responsive behaviours to the external stimulus or environment, which makes a perfect foundation for a ratiometric sensor. It is well-known that ratiometric sensors can eliminate most of the influences like optical properties of solution, concentration of the fluorescent materials and other experimental or instrumental factors.26 Great efforts have been made on developing TTA-UC system as a ratiometric platform for sensing oxygen27 and temperature.28 However, to the best of our knowledge so far, there is still no report on a ratiometric sensor based on TTA-UC for metal-ion detection. This new strategy elaborately utilizes the double-dye nature of the TTA-UC system and does not need to add an external reference, because the UC and PL signals can be internal reference for each other.
Herein, we designed and synthesized a novel annihilator DHTPA to form a TTA-UC system with sensitizer PdOEP. The system can also be exploited as a ratiometric sensor for the detection of Fe3+ ions. While the UC signal was significantly quenched and showed a good linear relationship with the Fe3+ concentration, the PL signal remained constant. This ratiometric sensor also revealed a high selectivity and sensitivity (7.26 × 10−7 M) to Fe3+ ions. This method will provide a new angle to build ratiometric sensors for applications in chemical and biological areas.
:
1, v/v). After refluxing for 48 h under nitrogen atmosphere, 9,10-anthracenediboronic acid bis(pinacol) ester was completely reacted. The mixture was then evaporated under reduced pressure and black powder was obtained. The crude powder was washed and extracted by saturated sodium chloride solution and dichloromethane, respectively. Column chromatography was used for separating the DHAPA after dehydrated by anhydrous sodium sulfate and the eluent was dichloromethane/petroleum ether (1
:
1, v/v). Yellow powder was eventually obtained after recrystallization (1.2 g, yield 60%). IR (KBr, cm−1): 3164s (–OH), 1700s (C
O) (Fig. S1†). 1HNMR (400 MHz, chloroform-d) δ 11.29 (d, J = 2.9 Hz, 2H), 10.11 (s, 2H), 7.83 (d, J = 8.0, 2.7 Hz, 2H), 7.72–7.66 (m, 4H), 7.41 (d, J = 6.9, 3.3 Hz, 4H), 7.23–7.13 (m, 4H) (Fig. S4†).
:
1, v/v) as eluent. 0.5 g faint yellow powder was obtained with yield of 37%. IR (KBr, cm−1): 3188s (–OH), 1635s (C
N) (Fig. S2†). MS (FT-ICR): C30H24N6O2S2 [M+] 564.14; found 565.15 (Mz) with the isotopic patterns for the corresponding molecular ions (Fig. S3†).1H NMR (400 MHz, DMSO-d6) δ 11.47 (s, 2H), 10.19 (s, 2H), 8.55 (s, 2H), 8.27–7.95 (m, 6H), 7.73–7.63 (m, 4H), 7.46 (d, J = 8.3 Hz, 4H), 7.02–6.82 (m, 4H) (Fig. S5†). Elemental analysis: measuring result (%): C (64.20), H (4.03), N (14.48), S (11.04); calculated result (%): C (63.83), H (4.29), N (14.88), S (11.33).For a contrast experiment, the typical fluorescence spectra of DHTPA excited by 398 nm UV light under different Fe3+ concentrations were also recorded after 10 min of reaction. The peak area integrations of fluorescent (455 nm) emissions in all the spectra were calculated.
The pH responsiveness of the TTA-UC ratiometric sensor was measured under different pH environment (pH = 4–11). The pH value was adjusted by adding different amount of hydrogen chloride or sodium hydroxide in the solution. All the UC spectra of different conditions were recorded and the peak area integrations of UC were calculated and compared.
The selectivity for Fe3+ ions was measured by adding other types of metal ions (Mn2+, NH4+, Zn2+, Mg2+, Cd2+, Pb2+, Li+, Na+, K+, Ag+, Ca2+) into the TTA-UC solution after 10 min of reaction, respectively. The concentration of different metal ions in these samples were all the same. It should be pointed out that except silver nitrate, soluble chlorides were also added in this step to avoid the influence of anions. All detection experiments were performed at room temperature. In order to avoid the influence of changing pH values, which are caused by different types of metal salts, on the UC intensities of the detecting sample, proper amount of buffer solution was added into the system.
The normalized absorption and steady-state photoluminescence spectra of DHTPA and PdOEP in DMF are shown in Fig. 2. There are three main peaks (344, 378 and 398 nm) in the absorption spectra of DHTPA (Fig. 2a). The probe molecule DHTPA exhibits one-peak fluorescent emission at 455 nm. Fig. 2b shows that as a classic metalloporphyrin complex sensitizer, PdOEP possesses a Soret absorption band at 395 nm and a Q-band at 547 nm and also reveals PL emission at 655 nm when excited by a 532 nm laser.
![]() | ||
| Fig. 2 Normalized absorption and steady-state photoluminescence spectra of (a) DHTPA and (b) PdOEP in DMF at room temperature. | ||
UC spectrum of DHTPA/PdOEP solution is shown in Fig. 3. The UC emission is at 458 nm under excitation of 532 nm, and meanwhile the PL emission of PdOEP is at 665 nm. To enhance the absolute intensity of UC emission from DHTPA and obtain a relatively higher SNR (signal to noise ratio) for the sensor, the ratio of PdOEP/DHTPA was investigated by fixing DHTPA concentration and increasing PdOEP concentration (Fig. S6†). The ratio of PdOEP/DHTPA was 1
:
2 when UC intensity reached the maximum. In order to eliminate the disturbance of pH changing during the detection of metal ions and to find an optimal operating condition, the integrated UC intensity of DHTPA/PdOEP system at different pH environments were measured and shown in the inset of Fig. 3. It is found that the UC intensity nearly remains constant and maximal under the pH from 6 to 9, which reveals that the sensor can be fully functional in a relatively broad neutral pH range, exhibiting a possibility of applications in biological field.
![]() | ||
| Fig. 3 UC emission spectrum of DHTPA/PdOEP system; inset: histogram of integrated UC intensity under different pH environments. | ||
The UC emission spectra of DHTPA/PdOEP system at environments of different concentration of Fe3+ ions are shown in Fig. 4a. All the spectra were recorded after the spectral signals are stable, since the reaction between DHTPA and Fe3+ ions would stop in 10 min (Fig. S7†). As a result, the Fe3+ ions have a great quenching effect on UC emission and meanwhile barely no influence on PL emission. Before adding Fe3+ ions, the blank sample displays purple emission light when excited by 532 nm laser. As the Fe3+ ions are added, the UC emission is effectively quenched and emission colour turn into red (insets of Fig. 4c). The obvious colour change can be easily distinguished by naked eyes. Interestingly, both the UC and PL emission intensities reveal good linear relationships with concentration of Fe3+ ions (Fig. 4b), which makes the DHTPA/PdOEP TTA-UC system a perfect candidate for ratiometric sensors. Particularly, the PL intensity shows nearly no change through the concentration increasing of Fe3+ ions, making it a very appropriate internal reference for UC signal. Finally, a good linear relationship (R2 = 0.995) between ratio intensity (IUC/IPL) and Fe3+ concentration (0–9 μM) is shown in Fig. 4c, yielding an effective ratiometric sensor for Fe3+ ion detection (Fig. 4d). As shown in Fig. 4d, the TTET process still existed after adding Fe3+ ions into the system, which can be verified by Fig. S8 and S9.† When varying the amount of added Fe3+ ions (0–10 μM), the absorption spectra of DHTPA are almost constant (Fig. S8†). The changing of PL lifetime of PdOEP can reflect the environments in the solution (Fig. S9†). When only PdOEP was added in the solution, the PL lifetime was relatively long. After adding DHTPA, the PL lifetime reduced obviously due to the emerging of TTET process. At last, Fe3+ ions (10 μM) were added into the solution, and the PL lifetime did not change much. If the TTET can be blocked by Fe3+ ions, the PL lifetime should increase obviously. In that case, the Fe3+ ions do not affect the TTET process, which also provides evidence to contant PL intensity.
The limit of detection (LOD) of this ratiometric sensor is 7.26 × 10−7 M, calculated by using eqn (S1).† Because of the presence of internal reference, ratiometric sensors can eliminate the negative influence from the devices, environment or probes themselves on the detecting results, improving the selectivity, sensitivity and stability of the sensor.29
In order to further prove the responsive nature of DHTPA to Fe3+ ions, the fluorescent emission of DHTPA dependent on Fe3+ ions is also investigated, and the results are shown in Fig. S10.† The fluorescence of DHTPA can also be quenched by Fe3+ ions (0–9 μM), and its intensity exhibits good linear relationship with Fe3+ concentration, yielding a normal one-channel Fe3+ sensor based on a fluorescent probe. The binding constant Ka of the complexing reaction derived from titration data in Fig. 4a and S6† are calculated based on Benesi–Hildebrand equation (Fig. S11†).30 The Ka from the UC signal is 2.218 × 104 M−1, while the Ka from the FL signal is 2.536 × 104 M−1. The similar Ka indicates that although different probes were used for Fe3+ sensing, the reaction between the metal ions and DHTPA is pretty much the same in the two situations.
The selectivity of the ratiometric sensor is shown in Fig. 5. The responsiveness of UC emission of DHTPA/PdOEP system to twelve types of metal ions (Fe3+, Mn2+, NH4+, Zn2+, Mg2+, Cd2+, Pb2+, Li+, Na+, K+, Ag+, Ca2+) is thoroughly studied. The results show that among those metal ions, only Fe3+ has a significant quenching effect on the UC emission (Fig. 5a). The quenching ratio of the Fe3+ ions is up to 64.8%, while no other metal ions are more than 4% (Fig. 5b), which shows a highly selectivity of the ratiometric sensor to Fe3+ among 12 types of metal ions.
![]() | ||
| Fig. 5 (a) UC emission spectra of DHTPA/PdOEP system at environments of different types of metal ions (10 μM); (b) histogram of quenching ratio calculated from UC emissions in (a). | ||
The mechanism of the responsiveness of UC emission to Fe3+ ions is due to the complexation between Fe3+ and DHTPA, which turned the fluorescent “D–π–D” structure into non-fluorescent “A–π–A” structure. The selectivity reveals that Fe3+ ions have stronger complex strength and faster complex reaction dynamics, yielding the DHTPA/PdOEP TTA-UC system a highly selective and effective ratiometric sensor for Fe3+ ions.
For the future perspective, since the oxygen sensitivity is an unavoidable issue in TTA-UC system, solutions must be considered to develop TTA-UC based ratiometric sensor with long term stability. So far great efforts have been made in solid-state UC materials and deoxygenating solvents,24 which will authentically make the TTA-UC material a promising candidate for sensing applications.
Footnote |
| † Electronic supplementary information (ESI) available. See DOI: 10.1039/c9ra06524e |
| This journal is © The Royal Society of Chemistry 2019 |