Ruiqian Lia,
Yuanyuan Houb,
Qiujing Donga,
Peibo Suc,
Pengfei Juc and
Jun Liang*b
aSchool of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, China
bState Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China. E-mail: jliang@licp.cas.cn
cShanghai Aerospace Equipment Manufacturer, Shanghai 200245, China
First published on 3rd January 2018
In this work, Co–P coatings were deposited from a chloride-based bath by direct current (DC), pulse current (PC) and pulse reverse current (PRC) methods, respectively. The effects of current modes on the microstructure, composition, microhardness, wear resistance and corrosion resistance of the Co–P coatings were explored. Results showed that the P content in the Co–P coatings increased and the surface roughness decreased in the sequence of DC, PC and PRC methods. The coatings with low P content deposited by DC and PC methods are crystalline with fcc and hcp structures, respectively, while the coating with high P content deposited by the PRC method is amorphous. Comparing to DC and PC methods, the PRC method can evidently improve the microhardness, wear resistance and corrosion resistance of Co–P coatings. The excellent wear and corrosion resistance of the Co–P coatings deposited by the PRC method could be attributed to its high P content, smooth surface and amorphous structure.
There are many factors that affect the P content and phase structures of Co–P coatings, such as electrical parameters (current modes and current density), plating bath composition (P source concentration, additive type and pH value) and bath temperature. Among these variables, current mode is a flexible and efficient variable to modify the P content and phase structures of alloy coatings. Ezhilselvi et al.1,7 demonstrated that the Co–P coatings deposited by PC method have better corrosion resistance than those by DC method. Pulse current (PC) and pulse reverse current (PRC) are the two most common types of pulsed method. In spite of the deposition of Co–P by DC and PC methods has been extensively studied,1–3,7 however, to the best of our knowledge, rarely attention has been paid to the deposition of Co–P alloy coating by PRC method. It was reported that alloy coatings deposited by PRC method exhibits higher corrosion resistance and wear resistance than that deposited by PC methods.8–12 The PRC mode contains two electrode reaction processes in a period, one is a cathode process, which is similar to that of PC mode; the other is an anode process, which not only inhibited the growth of grains, but also dissolved the unsteady phases. In the process of electrodeposition, a regular cathode and anode process are a best way to modify the composition and microstructures, and then improve the properties of alloy coatings. Generally, the Co–P coatings should satisfy both the wear resistance and corrosion resistance in the practical conditions. However, it's a great pity that the corrosion and wear resistance of Co–P coatings were rarely researched simultaneously.
In this work, Co–P coatings were electrodeposited by DC, PC and PRC methods on a copper substrate from chloride bath. The effect of current modes (DC, PC and PRC) on the microstructure, composition, corrosion and wear resistance of the Co–P coatings was investigated in detail.
Current types | Electrodeposition parameters |
---|---|
Direct current (DC) electrodeposition | |
Current density | 15 mA cm−2 |
![]() |
|
Pulse current (PC) electrodeposition | |
Peak current density | 15 mA cm−2 |
Pulse on-time | 400 μs |
Pulse off-time | 1600 μs |
![]() |
|
Pulse reverse current (PRC) electrodeposition | |
Peak current density of forward pulse | 15 mA cm−2 |
Peak current density of reverse pulse | 15 mA cm−2 |
Forward pulse on-time | 400 μs |
Forward pulse off-time | 1600 μs |
Reverse pulse on-time | 100 μs |
Reverse pulse off-time | 1900 μs |
Vickers microhardness test was carried out by a microhardness tester (HXD-1000B) at a load of 50 N for 5 s. Friction and wear tests sliding against an AS14 steel ball (Ø 6 mm) were performed with a ball-on-plate type wear tester (UMT, Tribolab) at room temperature with dry sliding conditions. The tests were performed at a constant applied load of 2 N and a sliding distance of 10 mm with a sliding frequency of 5 Hz for 30 min.
The corrosion behavior of the Co–P coatings were studied by potentiodynamic polarization (Tafel) and electrochemical impedance spectroscopy (EIS) on an Autolab PGSTAT302N electrochemical workstation in 3.5 wt% NaCl solution. An Ag/AgCl (saturated with KCl) reference electrode (SCE) and a Pt plate as counter-electrode were used in the tests. The impedance measurements were performed at open circuit potential (OCP) with an AC amplitude of 10 mV (peak to peak) in the frequency range of 30 kHz to 10 mHz. The specimens were immersed in the 3.5 wt% NaCl solution for about 60 min before Tafel and EIS tests to ascertain stable open circuit potentials. All the electrochemical measurements were repeated at least three times until good reproducibility of the data were obtained. All the electrochemical tests were carried out at room temperature (20 ± 2 °C).
Element | DC Co–P | PC Co–P | PRC Co–P |
---|---|---|---|
Co (wt%) | 98.7 | 96.6 | 88.0 |
P (wt%) | 1.3 | 3.4 | 12.0 |
The XRD patterns for the DC Co–P, PC Co–P and PRC Co–P coatings are presented in Fig. 2. It can be seen that there are three diffraction peaks at 44.6°, 51.5° and 75.7° assigned to the (111), (200) and (110) planes of Co for the DC Co–P coating. These peaks are in good agreement with those of the reference patterns for a mixed fcc/hcp phase with higher ratio of fcc phase structure. The highest intensity peak at 2θ of 75.7° indicates that the DC Co–P coating has a preferred orientation of (110) plane. The XRD pattern of PC Co–P coating show diffraction peaks at 41.7°, 44.8°, 47.5°, 90.3° and 98.8° corresponding to (100), (002), (101), (200) and (004) planes of hexagonal close packed (hcp) Co. It is evident that the PC Co–P coating is crystalline with the preferred orientation of (002) plane. The PRC Co–P coating shows an amorphous structure due to the higher phosphorous content.7 The average crystallite size of DC Co–P coating and PC Co–P coating evaluated from Debye–Scherrer equation are 24.6 and 15.7 nm, respectively. The refinement of grains could be attributed to the improvement of current distribution and mass transfer under PC condition. Based on the Tafel equation, a larger current density corresponds to a higher overpotential, which decreases the activation energy of nucleation, and causes an increased nucleation rate.13
The surface morphologies of Co–P coatings deposited by DC, PC and PRC methods are shown in Fig. 3a–c, respectively. It is clearly observed that the DC Co–P coating shows a spherical cluster structure with a size in the range of a few micrometers and some cracks and voids can be seen on the coating surface (Fig. 3a and a′). For the PC Co–P coating, the surface is characterized by irregular polyhedron structure and there are some small voids (Fig. 3b and b′). The Co–P coating deposited by PRC reveals a smooth and compact surface without any cracks and voids.
![]() | ||
Fig. 3 SEM images of surface morphology of Co–P coatings deposited by (a) DC, (b) PC and (c) PRC methods. |
The surface characterizations of the three types of Co–P coatings are further investigated by AFM. As shown in Fig. 4a, spherical protrusions are clearly visible on the surfaces of the DC Co–P coating with an average surface roughness (Ra) of about 97.2 nm. The PC Co–P coating, however, has smaller protrusions on the surface with Ra of ∼44.7 nm (Fig. 4b). The PRC Co–P coating exhibits more compact and smoother surface with the surface roughness (Ra) of about 8.5 nm (Fig. 4c). The decrease of roughness can be attributed to the pulse current breaking the normal growth of cobalt crystals and disrupting larger crystals from producing smaller nuclei.14 Furthermore, the PRC method dissolved the unsteady phases formed in the coating by anode pulse current (especially for the protrusions of the coating surface), resulting in a smooth surface.8 Correspondingly, the coatings show completely different glossiness (Fig. 5). The glossiness of DC Co–P, PC Co–P and PRC Co–P coating is 5.8, 30.6 and 518, respectively. The brighter surface of amorphous coating than nanocrystalline coating is due to the higher P content and more smooth surface.1,15
In order to study the thickness of Co–P coatings and the binding of Co–P coating with Cu substrate, the cross section images of three Co–P coatings are shown in Fig. 6. It is clearly seen that the thickness of DC Co–P, PC Co–P and PRC Co–P coatings are decreasing. Compared with PC Co–P and PRC Co–P coatings, however, the surface of DC Co–P coating is very rough and has large number of cracks and voids. These results are well agreed with the surface morphology as shown Fig. 3 and 4. From the EDS analysis it could be observed that the P content of all the three Co–P coatings remained almost same throughout the coating thickness, indicating that the composition distributing of Co–P coatings was homogeneous in thickness direction from surface to interior.
The friction coefficient of the DC Co–P, PC Co–P and PRC Co–P coatings as a function of the sliding time are shown in Fig. 8. It is noted that the DC Co–P coating exhibited higher friction coefficient (0.66) with a large fluctuation. The fluctuation of friction coefficient is due to the rough surface of the coating. The PC and PRC Co–P coating, however, shows a stable and lower friction coefficient (0.54 and 0.48, respectively). For the cobalt-based alloys, it was reported that the hcp structure exhibits lower friction coefficient and wear rate than the fcc structure.17–19 Therefore, the DC Co–P coating characterized by a mixed fcc/hcp structure with higher ratio of fcc shows a higher friction coefficient than the hcp structural PC Co–P coating. The PRC Co–P coating exhibits a lower friction coefficient than the PC Co–P coating, which is mainly due to its smooth surface and amorphous structure.20
The wear track is an important evidence to demonstrate the tribological mechanism. As shown in Fig. 9, the DC Co–P coating (Fig. 9a) is characterized by rough worn surface, plenty of wear debris and severe plastic deformation, indicating that the wear mechanism of the DC Co–P coating is mainly adhesive wear. The worn surfaces for PC Co–P coating (Fig. 9b) are characterized by abrasive grooves along the sliding direction, less wear debris and plastic deformation. It was the classical mixed mechanism of adhesive–abrasive wear. However, the PRC Co–P coating shows smoother worn surface with a small amount of wear debris and plastic deformation, indicating that the PRC Co–P coating with hcp structure has excellent anti-adhesive wear properties.17,21
The wear rates of the Co–P coatings deposited by DC, PC and PRC methods are shown in Fig. 10. It is noticed that the DC Co–P coating has the highest wear rate, suggesting that the wear resistance of the coating is rather weak due to the lower microhardness. Compared with the DC and PC Co–P coatings, the PRC Co–P coating exhibits the lowest wear rate, which is mainly dependent on the higher microhardness and lower friction coefficient.20 It reveals that the current mode can affect wear behaviors of Co–P coatings by changing crystal structure and P content of Co–P coatings.
![]() | (1) |
![]() | (2) |
![]() | ||
Fig. 11 The potentiodynamic polarization curves of Co–P coatings deposited by DC, PC and PRC methods. |
Specimens | Ecorr (V vs. Ag/AgCl) | icorr (A cm−2) |
---|---|---|
DC Co–P | −0.51 | 9.4 × 10−6 |
PC Co–P | −0.48 | 2.2 × 10−6 |
PRC Co–P | −0.39 | 1.8 × 10−7 |
The eqn (2) shows near steady-state barrier layer of hypophosphite anion. This layer in turn prevents the water to from reaching the electrode surface, thereby preventing the dissolution of cobalt.
The EIS tests are carried out to further investigate the corrosion resistance of the Co–P coatings. Fig. 12 shows the resulting EIS plots of various specimens in a non-deaerated 3.5 wt% NaCl solution. The Nyquist plot (Fig. 12a) exhibits depressed semicircle with a single capacitive loop in the high frequency region that indicates a charge controlled reaction. It is clear that the radius of capacitive loops decreases in sequence of PRC Co–P, PC Co–P and DC Co–P coatings, indicating that the PRC Co–P coating has a better corrosion resistance than the DC and PC coatings. It can be seen from Fig. 12a that the DC Co–P coating shows the lowest value of |Z|f → 0 (2.15 × 103 Ω cm2). Compared with the DC coating, the value of |Z|f → 0 of the PC Co–P coating (4.93 × 103 Ω cm2) is slightly increased, whereas the value of |Z|f → 0 of the PRC Co–P coating (5.87 × 104 Ω cm2) is more than one order of magnitude higher than that of the PC Co–P coating.
The impedance spectra for the Nyquist plots are analyzed by fitting the experimental data to the equivalent circuit model as shown in Fig. 12a. There is only one obvious extremum in the phase angle curves (Fig. 12c), which means that there is only one time constant. A good fit with this model was obtained with an average error of about 3%. In this equivalent circuit, Rs represents the solution resistance. Rct represents the charge transfer resistance, which is a measure of electron transfer across the surface and is inversely proportional to corrosion rate. Constant phase element (CPE) represents the capacitance of the double layer (Cdl), which provides information about the polarity and the amount of charge at the surface/electrolyte interface. The fitted results of circuit elements obtained from Zview software are summarized in Table 4. From the fitted data, it can be seen that the Rct of Co–P coating deposited by PRC method is much higher than that of the other coatings, indicating that the corrosion resistance of PRC Co–P coating is the best while the corrosion resistance of coatings deposited by DC is the worst. Furthermore, the fitted data showed that the CPE value became lower and lower in order of the DC Co–P, PC Co–P and PRC Co–P coatings, while the n value became higher and higher correspondingly. The lower value of CPE indicates the corrosion layers for the PRC Co–P coating is becoming less permeable and the higher n values suggests a homogeneous, smooth and pore-free deposits that results in a better corrosion resistance of the PRC Co–P coating.24 The results of corrosion resistance obtained from EIS plots are well consistent with the polarization tests.
Specimens | Rs (Ω cm2) | CPE(Y0)1 (S cm−2 sn) | n1 | Rct (kΩ cm2) |
---|---|---|---|---|
DC Co–P | 61.8 | 7.8 × 10−6 | 0.79 | 8.9 |
PC Co–P | 63.3 | 3.4 × 10−6 | 0.83 | 17.2 |
PRC Co–P | 67.4 | 8.2 × 10−7 | 0.95 | 63.7 |
This journal is © The Royal Society of Chemistry 2018 |