Open Access Article
This Open Access Article is licensed under a
Creative Commons Attribution 3.0 Unported Licence

Correction: The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements

Mikolaj Jan Jankowski *, Raymond Olsen , Yngvar Thomassen and Paal Molander
National Institute of Occupational Health, P.O. Box 8149, N-0033, Oslo, Norway. E-mail: mikolaj.jankowski@stami.no

Received 17th January 2018 , Accepted 17th January 2018

First published on 7th February 2018


Abstract

Correction for ‘The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements’ by Mikolaj Jan Jankowski et al., Environ. Sci.: Processes Impacts, 2016, 18, 810–818.


The reported ion-neutral collision rates (capture rate) were erroneously estimated using the PTR-MS drift tube temperature and not the effective temperature (Teff) resultant of the electric field in the drift tube. Thus, the reported collision rates for polar compounds are too high resulting in an overestimation of the instrument response factors and consequently leading to underestimated volume mixing ratios for methyl and ethyl isocyanate. Volume mixing ratios for ICA are unaffected by this error, as the PTR-MS was calibrated against an FT-IR spectrometer. However, the formula (eqn (4)) used for PTR-MS response correction is based on incorrect reaction rates. Fig. 4 is marginally affected. The error does not change the conclusion of the article.

 

• In the ninth sentence of the “PTR-MS measurements” section (p. 812), the values “1.68, 2.12, 2.24” replace “2.89, 4.11, 4.12”.

• In the Fig. 3 image: the legend should read:

m/z 44, kSC = 1.68 × 10−9 cm3 s−1

m/z 72, kSC = 2.24 × 10−9 cm3 s−1
and the equations for the linear fits are replaced by:
fm/z[thin space (1/6-em)]44 = 0.7950 − 0.0126 × AH

fm/z[thin space (1/6-em)]72 = 0.2904 − 0.0126 × AH

• Corrected eqn (4):

image file: c8em90007h-t1.tif

• Fig. 4: equation for the cubic fit replaced by: f(x) = 228 − 26.8x + 2.59x2 − 0.112x3

• Fig. 5: traces for m/z 58 and 72 are increased by a factor of 1.94 and 1.84, respectively.

• In the ninth sentence of the second paragraph of the “Thermal decomposition of polymers” section (p. 817), the values “2.2, 1.9” replace “1.3, 1.3”.

• In Table 1, the data in the PTR-MS columns for MIC and EIC are increased by a factor of 1.94 and 1.84, respectively.

 

The Royal Society of Chemistry apologises for these errors and any consequent inconvenience to authors and readers.


This journal is © The Royal Society of Chemistry 2018