Open Access Article
Bo Zhanga,
Rui Shi
b,
Weili Duana,
Zhonglong Luoa,
Zhong-yuan Lu
b and
Shuxun Cui
*a
aKey Lab of Advanced Technologies of Materials, Ministry of Education of China, Southwest Jiaotong University, Chengdu 610031, China. E-mail: cuishuxun@swjtu.edu.cn
bState Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University, Changchun 130023, China
First published on 5th July 2017
Sample preparation is crucial to the studies of polymers on surfaces and interfaces. For studies using single-molecule force spectroscopy (SMFS), sample preparation is the key to obtain high-quality data. In each of the previous SMFS studies, either physisorption or chemisorption was applied in the sample preparation. However, a direct comparison on the same polymer species with both of the two strategies has not been reported yet. With two methods (physisorption, “PS”, or chemisorption, “CS”) and two surfaces (AFM tip or quartz substrate), four types of samples of poly(ethylene glycol) (PEG) can be prepared from the polymer solution. The performance of these samples with the same species of PEG are directly compared by SMFS. It is found that among these samples, two of them, i.e., tip-CS and substrate-PS, are suitable for SMFS. The advantage of substrate-PS is the simple preparation. In contrast, the advantage of tip-CS is the higher rupture force and the lower sample consumption. The former feature will be time saving if a high rupture force is needed in the analysis. The latter feature will be economic when an expensive sample is used. The other two types of samples, i.e., tip-PS and substrate-CS show lower data yield and lower rupture force. In summary, the tip-CS and substrate-PS are recommended for sample preparation in SMFS. The tip-CS is the most promising protocol, if a functionalized polymer sample is available.
Chemisorption can be applied on surfaces of either the AFM tip or the solid substrate.13–15 Several protocols, such as thiol–gold chemistry and biotin–avidin recognition, have been developed to strongly tether a polymer chain to a surface under mild conditions.16–18 Chemisorption requires specific chemical bond to be formed and so is inherently specific to a certain surface/molecule system, whereas physisorption is generic and all kinds molecules roughly produce similar physisorbed results.
In each of the previous SMFS studies, either physisorption or chemisorption was applied in the sample preparation.19–24 However, a direct comparison on the same polymer species with both of the two strategies has not been reported yet. Here, we select poly(ethylene glycol) (PEG) as the model polymer to perform the direct comparison under similar conditions.25–27 Experimental results show that both of two methods have their own advantages. The results indicate that the chemisorption method is superior to physisorption on the aspects of rupture force and the concentration of the sample solution. The advantage of the physisorption method is the facile preparation.
CH-PEG5K) was purchased from Shanghai Sangon Biotech Ltd. PEG was dissolved in tetrahydrofuran (THF) to a certain concentration. Deionized (DI) water (>15 MΩ cm) was used when water is involved. Other chemicals were analytically pure and used without further treatment.
For the preparation of hydroxyl-group modified quartz substrate, the quartz slide was immersed in a hot piranha solution (98% H2SO4 and 30% H2O2, 7/3, v/v) for 30 min. After that, the substrate is thoroughly rinsed with abundant DI water, followed by drying with air flow.
![]() | ||
| Scheme 1 The chemisorption procedure (A) with three steps and the physisorption procedure (B) with two steps. | ||
![]() | ||
| Fig. 1 (A) Typical F–E curves of PEG sample of tip-CS obtained in nonane, and (B) the normalized F–E curves of those shown in (A). | ||
According to previous work in our group, we can use the QM-FRC model to quantitatively describe the single-chain elasticity of PEG obtained in nonane.11,27,33 In the QM-FRC model (see ESI† for details), the theoretical single-chain elasticity of PEG by ab initio quantum mechanical (QM) calculations is integrated into the freely rotating chain (FRC) model:34,35
| R/L0 = (L[F]/L0) × [1 − (kBT)/(2Flb)] | (1) |
During the elongation of PEG, L[F]/L0 is an ergodic value ranging from 1 to a number corresponding to the rupture of the polymer bridge. If the strength of a C–S bond (2800 pN, see Fig. S4 in ESI†) is set as the upper limit of the stretching force,17 the upper limit for L[F]/L0 is about 1.159, according to eqn (1). For a given value of lb, the fitting curve can be obtained when the value of L[F]/L0 is changed from 1 to 1.159.
As shown in Fig. 2A, the experimental F–E curve lies between the two fitting curves, indicating that the lb value for PEG is in the range of 0.1–0.3 nm. An analysis is carried out to find the optimum value for lb. The averaged deviation force, namely
, where n is the number of points in the compared range, is plotted against lb in Fig. S5.†33 The minimum force deviation is found at lb = 0.147 ± 0.001 nm, where the value of the averaged difference (19.1 pN) is very close to the standard deviation of the noise signal in the force measurements (15.4 pN). As shown in Fig. 2B, the entire region of the experimental F–E curve can be fitted well by the QM-FRC model with lb = 0.147 nm.11,33
Interestingly, the fitting result (0.147 nm) corresponds to the average bond length of the C–O–C– backbone of PEG, showing that the QM-FRC model is a structure-relevant model. The excellent fitting result in the entire force regime indicates that the QM calculations reflect the inherent single-chain elasticity of PEG, and the QM-FRC model is appropriate for PEG. These results indicate that chemisorption could be used to measure the inherent elasticity of a single PEG chain.
Previous studies showed that QM-FJC model, which was derived from the freely-jointed chain model, can also be used to describe the single-chain elasticity of polymers.36,37 Here in this study, we find that the single-chain elasticity of PEG can be described well by QM-FJC model, when lk = 0.294 nm (Fig. S6†). In the low force region (F < 40 pN), however, there is a remarkable difference between the fitting curves of QM-FJC model and QM-FRC model. These results are in accord with the previous finding that these two models are equivalent if lk = 2lb, when the stretching force is high enough.37 In fact, we find that when F > 40 pN (the noise level is ∼10 pN), the two fitting curves of PEG can be superposed well, see Fig. S6† for details.
Next, the factors that may influence the chemisorption were studied. When visible light or catalyst (Eosin Y) was absent in the sample preparation, respectively, no effective force signal of polymer could be obtained in the extensive force measurements (∼3000 times approaching–stretching cycles, see Fig. S7†). These control experiments demonstrate that both visible light and the catalyst are necessary in the chemisorption.31 We have also performed similar force measurements with different stretching velocity (0.5–5 μm s−1), and observed no velocity dependence, see Fig. S8.† This result indicates that the force measurements are carried out in the quasi-equilibrium condition.11,27
In addition, the force measurements have been carried out in PBS aqueous buffer. In this case, the F–E curve of PEG present a fingerprint plateau (see Fig. S9† for details), which is in accordance with the literature.25
000 F–E curves are collected for statistical analysis. The optimum concentration is defined as the concentration that corresponds to the maximum probability of single-chain event (i.e., the peak of the Gaussian fitting curve in Fig. 4A and B). For chemisorption, the optimum concentration is 131 ± 4 mg L−1, which is much lower than that for physisorption, 1249 ± 30 mg L−1. For both of the two sample preparation methods, the probability of the single-chain stretching event will be increased with the increasing of the PEG solution concentration, until a maximum is reached. Henceforth, the probability will be decreased if the PEG concentration is increased further. The possible reason could be that when the concentration of the solution is too high, the resultant concentration of the polymer chains on the sample surface will be increased so that the AFM tip would capture multiple-chains at the same time, which will lower the yield of the single-chain data (see Fig. S11†). Note that for the case of tip-CS, both of the solution volume and the concentration of the solution is reduced. In a typical case, the chemisorption method will save about 97% raw materials during sample preparation (see Fig. S1† for details). Thus, the chemisorption method is more efficient than the physisorption method. This advantage will be very valuable if the sample polymer (for instance, a synthetic peptide) is expensive.38
Furthermore, the statistical analysis shows that the rupture force (i.e., the peak force value at the end of polymer stretching) for tip-CS is 1092 pN (σ = 160 pN), which is higher than that for substrate-PS, 675 pN (σ = 140 pN), see Fig. 4. The enhanced rupture force for tip-CS is reasonable since one end of PEG is covalently tethered to the AFM tip, while for physisorption, neither ends are covalently tethered. Since the polymer bridge will be broken at the weakest point, the rupture forces correspond the desorption forces of the physisorbed end from the solid surface. Thus, the difference of the rupture forces between the CS sample and PS sample is not very large. For the case of substrate-PS, it is still possible (∼10% in the effective F–E curves) to obtain a high rupture force (1500–2100 pN), see Fig. 4C. The plausible reason is that the AFM tip is very sharp (tip radius of 10–20 nm), which will lead to a very high pressure (∼10 GPa) upon contact to the substrate (indentation force of ∼5 nN). With this high pressure, strong physisorption or even covalent bonds might be formed between the polymer chain and tip/substrate.34
In general, a relatively high force is needed to reflect more information of the sample molecules. For example, to observe the force induced ring-opening reaction in the gem-dibromocyclopropane-functionalized polybutadiene chain, the applied force should be higher than 1200 pN.39 It is clear that covalent bonds are stronger than the non-covalent ones at the single-molecule level. Thus, chemisorption would be a better choice when a high rupture force is required in the SMFS experiments. The advantage of physisorption is the simple preparation. If a large number of single-molecule pulling cycle can be carried out, the high rupture force can also be observed. In contrast, the chemisorption method is time saving in the force measurements.
For the sample of substrate-PS, the measured rupture force reflects the desorption force from either the AFM tip or the substrate. Note that in this case, both the AFM tip and the substrate are modified with hydroxyl groups. For the sample of tip-CS, one end of the PEG chain is covalently tethered to the AFM tip. The rest part of the chain is free for physisorption to the substrate upon contact. The desorption signal detected upon pulling reflects the desorption force of the physisorbed part from the hydroxyl-group modified substrate. The above section shows that the rupture force for the sample of tip-CS is much higher than that of the sample of substrate-PS. A plausible reason for this result could be that for the substrate-PS sample, the desorption force of PEG from the substrate is stronger than that from the AFM tip, though both of the surfaces are modified with hydroxyl groups. This is in good agreement with our experience in SMFS: after a series of pulling cycles (∼1000 times) on the substrate with physisorbed polymer, the AFM tip is often clean enough for further experiments on the same sample. Monte Carlo (MC) simulations also shows that this assumption is reasonable, see Section 3.4 for details.7
As what has been mentioned in the section of Sample preparation, we have 4 kinds of samples in total. In addition to the two kinds of samples that have been discussed above, we also evaluate the performance of the other two kinds of samples, i.e., the tip-PS sample and substrate-CS sample (Scheme S1, Fig. S12†).
For the tip-PS sample, a very low yield (∼1/800) of the effective F–E curve is observed. The rupture forces of these F–E curves mainly located around 450 pN (Fig. S13†), which is lower than that observed on the sample of substrate-PS (675 pN) and tip-CS (1092 pN). The lower rupture force and yield of data is rationalized as follows. For the sample of tip-PS, any part of the PEG chain could adsorb on the AFM tip surface by physisorption. Compared to the height of the AFM tip (∼6 μm), the length of the PEG chain (<300 nm) is much shorter. Thus, the PEG chain will have a very low possibility to extend out of the AFM tip (Scheme S1B†), which will result in a very low yield of data. Even if the polymer bridge is built between tip and substrate, there will be few anchor points on the substrate, which will lead to a low rupture force.
For the sample of substrate-CS, the most probable rupture force is 512 pN (σ = 69 pN), which is lower than that observed on the sample of tip-CS, see Fig. S14.† The yield of data (∼1/360) is also lower than that of the sample of tip-CS. The following factors may contribute to the lower data yield and rupture force. Since a very low concentration of the PEG solution is used, the surface concentration of PEG chains will be very low. AFM images that the typical surface coverage is about 0.9% for the substrate-CS sample, which is much lower than that for the substrate-PS sample (∼9.1%), see Fig. 5. It is expected that the distance between two spots (PEG chains) is much larger than the tip radius (10–20 nm), see Fig. 5B. Therefore, it is not easy to capture a PEG chain on the substrate in a short time (i.e., several pulling cycles). Even if a PEG chain is captured by the tip, it is likely that only a very short part of the chain is available for physisorption on the tip (due to the tiny size of the tip and short chain length of PEG). Thus, there will be few anchor points of PEG adsorbed on the tip during contact, which leads to a low rupture force upon pulling.
000 times. The random number X1 represents the desorption force of the physisorbed PEG chain from the substrate. The histogram shows that the random number X1 follows a very similar distribution to that of the force measurements, see Fig. S15.†
000 times. Each time we select the smaller number in X1 and X2 as the rupture force in that single pulling event, since the polymer bridge always breaks at the weakest point of the chain. The histogram shows the most probable rupture force value of 1006 pN, which is much higher than that obtained in the experiments (675 pN), see Fig. S16 and S17.† This marked discrepancy implies that the previous assumption is not reasonable. That is to say, the two distributions of the desorption forces of PEG, one from AFM tip and the other from the substrate, should be different.Then we try to generate random number X1 and X2 from two different Gaussian distributions, respectively, the first one with μ = 1092 pN and σ = 160 pN (represents the desorption force from substrate) and the second one with a smaller μ and similar σ value (represents the desorption force from AFM tip). After trial and error, we find that when a Gaussian distribution of μ = 675 pN and σ = 140 pN is used to represent the desorption force from AFM tip, the final result of the simulations agrees well with the results in the experiments, see Fig. 6. Note that the second distribution used in the MC simulations (μ = 675 pN and σ = 140 pN) is exactly the same to that of the experimental desorption force for the sample of physisorption. This result clearly shows that in the experiments, the desorption force from AFM tip (μ = 675 pN) is much lower than that from the substrate (μ = 1092 pN). This explains well why the desorption force for the sample of physisorption is much lower than that for the sample of chemisorption. On the other hand, this result predicts that a polymer chain prefers to stay on the substrate, when the surface components of the AFM tip and substrate are similar. This is in good agreement with our experience in SMFS: after a series of pulling cycles (∼1000 times) on the substrate with physisorbed polymer, the AFM tip is often clean enough for further experiments on the same sample.11,36
Note that in the case of physisorption, both the AFM tip and the substrate are modified with hydroxyl groups. The lower desorption force from the tip implies that other factors rather than the surface components influence the desorption force. The following factors may contribute to the lower desorption forces: the size and shape of the AFM tip are largely different from that of the flat substrate. In this case, the PEG chain may have less anchor points on the AFM tip, which lead to a lower binding force.
Footnote |
| † Electronic supplementary information (ESI) available: QM-FRC model, scheme for the SMFS experiments of physisorption and chemisorption, control experiments, results of various PEG concentrations, Monte Carlo simulations. See DOI: 10.1039/c7ra05779b |
| This journal is © The Royal Society of Chemistry 2017 |