DOI:
10.1039/C6RA14094G
(Paper)
RSC Adv., 2016,
6, 67409-67417
Synergistic effects between [Emim]PF6 and aluminum hypophosphite on flame retardant thermoplastic polyurethane
Received
31st May 2016
, Accepted 10th July 2016
First published on 11th July 2016
Abstract
This article mainly studies the synergistic flame retardant effects and smoke suppression properties of ionic liquid ([Emim]PF6) and aluminum hypophosphite (AHP) on thermoplastic polyurethane (TPU); AHP was used as the main flame retardant and [Emim]PF6 was used as the catalytic/synergistic agent. Then, the flame retardant effects of all TPU composites were tested using the limiting oxygen index (LOI), UL 94 test, cone calorimeter test (CCT), smoke density test (SDT), thermogravimetric analysis (TG) and thermogravimetric/Fourier transform infrared spectroscopy (TG-IR). Remarkably, with 0.0625 wt% content of [Emim]PF6 and 19.9375 wt% content of AHP, the sample reached a UL 94 V-0 rating, the LOI value increased by 35.75%, and the heat release and smoke production reached the minimum value among all samples. TG and TG-IR data reveal that AHP and [Emim]PF6 improve the thermal stability of samples at high temperature and reduce the production of some toxic gases.
1. Introduction
Thermoplastic polyurethane (TPU) is well known for its excellent mechanical properties (high tensility, excellent wear abrasion resistance, good hydrolytic stability, good flexibility over a wide range of temperatures, etc.) and is widely applied in the plastic field.1–3 However, the same as for many other thermoplastics, due to its flammability and melt-dropping during combustion, its applications in many fields are greatly limited. Therefore, the applications of effective and environmentally friendly flame retardants in TPU is quite important and urgent.4–7
Halogenated flame retardants used to be widely applied in polymers to improve the flame retardancy efficiently, but some of them have been prohibited in many fields because of releasing much toxic and corrosive gases during combustion.8,9 Recently, halogen-free flame retardants have attracted much more attention. Compounds based on phosphorus, nitrogen, silicon, and other elements gradually replaced the use of halogenated flame retardants.8 Metal hydroxide is widely used as a kind of cost-effective and environmentally friendly flame retardant. The most widely used metal hydroxide flame retardants include magnesium dihydroxide (MH) and aluminum trihydroxide (ATH). Pinto et al.4 found that TPU composites with 70 phr of ATH had good flame retardancy, and reached V-0 rating in UL 94 test. However very high addition levels of this category of flame retardants (generally beyond 50 wt%) are usually required, which is prone to cause deterioration of mechanical properties.10 Phosphorus-based compounds are another kind of effective and environmentally friendly flame retardants.8 Phosphorus-based flame retardants can volatilize into gaseous phase and form phosphoric radicals (PO2˙, PO˙, etc.), which can capture the radicals for combustion, and hence decrease or even stop the combustion reactions.11 Moreover, phosphorus-based flame retardants can catalyze the char formation of polymers.10 The char on the composite surface prevents heat and oxygen from transferring into the underlying polymer, and also prevents pyrolysis of the polymer from transferring to the flame zone, causing improvements in flame retardancy. Intumescent flame retardants (IFRs), which are composed of an acid source, carbonizing agent, and blowing agent, have received great attentions for its low smoke generation, low toxicity, non-dropping, low corrosion, high efficiency, etc., during their fire situation.12 In the process of polymer flame retardant, IFR preferably showed advantages of high efficiency, more carbon residue, little smoke, little molten drops and low toxicity for the flame retardancy of TPU composites.6,13–15
Metal salts of hypophosphorous acid have attracted a lot of interest recently because of their efficient and environmentally friendly flame retardancy.16 Hu et al. prepared flame retardant glass-fiber reinforced poly (1,4-butylene terephthalate) (GRPBT) using aluminum hypophosphite (AHP), polycarbonate and melamine, the composites reached UL 94 V-0 rating.17 Li et al. reported that AHP effectively promoted the char formation of PA6.18 Tang et al.19 incorporated AHP into PLA to prepare FR-PLA composites, finding that the FR-PLA composites showed excellent flame retardancy and reached UL 94 V-0 rating with 20 wt% AHP incorporation, and the pHRR value decreased by 48.2% when the content of AHP increased to 30 wt%. Xiao et al.20 found that TPU with the 30 wt% loading of AHP reached UL 94 V-0 rating, and the LOI value reached 30.2, the pHRR value decreased by 38.7% and AHP improved the formation of char residual. Though AHP endowed good flame retardancy for TPU, however, the 30 wt% loading is still very high. Adopting a highly efficient synergistic agent combined with AHP applied in TPU, and efficiently decreasing the content of AHP is an important research topic.
Designing novel flame retardants or introducing catalysts/synergists into the TPU/AHP systems may have good results to increase the flame retardant efficiency of AHP. Among all methods, adopting catalysts/synergists is more convenient and most of them are inorganic materials.21–25 Though these catalyst/synergists have good effects on flame retardancy, they are difficult to be dispersed uniformly into the resin because of their low content and poor compatibility. Ionic liquid is a kind of organic molten salt, which is consist of a relatively large volume structure asymmetric organic cation and a relatively small size of inorganic anion.26 Because of its excellent chemical stability and thermal stability, no ignition and flammable, low vapor pressure and high ionic conductivity characteristics, ionic liquid has attracted more and more attention in organic synthesis, catalysis and extraction processes as “green solvents”.27,28 Despite the ionic liquid has many excellent properties, the application inflame retardancy is quite few. Chen et al.29–31 found that polyoxometalate based ionic liquid (PIL) can behave as efficient catalyst in many reactions, also in flame retardant fields, they studied the synergistic effect of IFR and PIL in PP system, and found that the anion of PIL affected the flame retardant properties of PP greatly. Li et al.32 studied the effect of the ionic liquid [Bmim]OTM on flame retardancy, thermal degradation and char yield of PC, and found that when incorporating 0.1 wt% [Bmim]OTM into PC, sample reached to UL 94 V-0 rating, the LOI of PC reached up to 32%, and it could decrease the initial decomposition temperature of PC and promote the degradation of PC. Li et al.33,34 studied the flame retardant effect of imidazole ionic liquids on RPUF by researching the influence of varieties and amount of the ionic liquids on LOI and thermal decomposition properties, they found that imidazole ionic liquids have good flame retardancy on RPUF and the [Bmim]PF6 showed better flame retardancy and thermostability than [Bmim]BF4. Therefore, it is a feasible method to adopt an ionic liquid as catalysts/synergists for flame retardant TPU composites.
In this paper, a kind of imidazole ionic liquids ([Emim]PF6) was adopted as the catalytic/synergistic agent and combined with AHP as the main flame retardants in TPU composites. Then the flame retardant performance and thermal stability of TPU/AHP/[Emim]PF6 were characterized by LOI, UL 94 test, CCT, SDT, TG and TG-IR, respectively.
2. Experimental section
2.1 Materials
Thermoplastic polyurethane (TPU, Desmopan 9380A) with a density of 1.110 g cm−3 and 82 Shore A hardness, was supplied by Bayer Material Science (German). Aluminum hypophosphite (AHP, ≥99%) with particle size of 2000 mesh was provided by Chengdu Weili Flame Retardant Chemicals Industrial Co., Ltd. (China). 1-Ethyl-3-methylimidazolium hexafluorophosphate ionic liquid ([Emim]PF6) was obtained from Henan Lihua Pharmaceutical Co., Ltd. (China) with a purity more than 99.5 wt% and molecular weight of 256.13 g mol−1.
2.2 Sample preparation
TPU/AHP/[Emim]PF6 composites were prepared by melt-blending method. Before processing experiment, both AHP and TPU were dried in a drying oven at 80 °C for 12 h, [Emim]PF6 was kept under a vacuum at 80 °C for at least 3 days to reduce the moisture content and volatile compounds to negligible values. A certain amount of TPU was melted in the mixer at 180 ± 5 °C. Then a certain amount of AHP and [Emim]PF6 were added into the mixer, respectively. The blends were mixed for 10 min and hot pressed into sheets in the dimensions of 100 × 100 × 3 mm3 using the plate vulcanizing machine and then cut into suitable sample bars for LOI and UL 94 test. The formulations of flame retardant TPU composites are presented in Table 1.
Table 1 Formulations and LOI value and UL 94 rating of all samples
Sample |
TPU/wt% |
[Emim]PF6/wt% |
AHP/wt% |
LOI |
UL 94 |
TPU |
100 |
— |
— |
23.75 |
No rating |
AHP-1 |
80 |
— |
20 |
32.50 |
V-1 |
AHP-2 |
80 |
0.03125 |
19.96875 |
34.25 |
V-0 |
AHP-3 |
80 |
0.0625 |
19.9375 |
35.75 |
V-0 |
AHP-4 |
80 |
0.125 |
19.875 |
33.25 |
V-1 |
2.3 Measurements
Limiting oxygen index (LOI). LOI was carried out on an HC-2 oxygen index meter (Jiangning Analysis Instrument Company, China) according to the standard oxygen index test ASTM D2863. The samples used were of dimensions 100 × 6.5 × 3 mm3. And, five samples were carried out in the LOI test.
UL 94 test. The vertical burn test was measured by a CFZ-2-type instrument (Jiangning Analysis Instrument Company, China) according to the American National UL 94 test ASTM D3801 on sheets 100 × 13 × 3 mm3. And, three samples were carried out in the UL 94 test.
Cone calorimeter test (CCT). The cone calorimeter (Stanton Redcroft, UK) tests were performed according to ISO 5660 standard procedures. Each specimen of dimensions 100 × 100 × 3 mm3 was wrapped in aluminium foil and exposed horizontally to an external heat flux of 35 kW m−2 with the use of the “frame and grid”. And, three samples were carried out in CCT.
Smoke density test (SDT). A smoke density test machine (JQMY-2, Jianqiao Co, China) was used to measure the smoke characteristics according to ISO 5659-2 (2012). Each specimen with dimensions of 75 × 75 × 3 mm3 was wrapped in aluminum foil and exposed horizontally to an external heat flux of 25 kW m−2 with or without the application of a pilot flame. Two tests were carried out for each one sample.
Thermogravimetric analysis (TG). Thermogravimetric analysis of the sample was performed using a DT-50 (Setaram, France) instrument. About 10.0 mg of sample was put in an alumina crucible and heated from ambient temperature to 700 °C. The heating rate was set as 20 °C min (nitrogen atmosphere, flow rate of 20 mL min−1).
Thermogravimetric/Fourier transform infrared spectroscopy (TG-IR). The TPU/AHP/[Emim]PF6 composites was also tested by a thermogravimetric/Fourier transform infrared spectroscopy hyphenated technique. About 10.00 mg of composite was put in to an alumina crucible and heated from 260 °C to 700 °C at the rate of 20 °C min−1. The spectra of volatilized products at various time during the thermal degradation of samples was presented on the computer screen of Fourier infrared spectrum.
3. Results and discussion
3.1 Limiting oxygen index (LOI) and UL 94 test
LOI is defined as the minimum percentage of oxygen in an oxygen–nitrogen mixture that is just sufficient to sustain combustion of the sample after ignition. LOI and UL 94 test are widely used to evaluate the flame retardant properties of materials, especially for screening flame retardant formulations of polymers. Thus, Table 1 presents the related LOI and UL 94 data obtained from different content of AHP and [Emim]PF6. It is obvious that the LOI of TPU is only 23.75, and sample cannot pass UL 94 flammability rating test. When incorporating 20 wt% AHP into TPU, sample AHP1 reached UL 94 V-1 rating, and LOI value is as high as 32.50, much higher than that of TPU. Moreover, when [Emim]PF6 was added into TPU/AHP system, the LOI value of samples further increased. For example, the LOI value of AHP2, AHP3 and AHP4 reached 34.25, 35.75, 33.25, respectively. Among all samples, AHP3 with 0.0625 wt% [Emim]PF6 has the highest LOI value. All TPU/AHP/[Emim]PF6 samples passed UL 94 flammability rating test, AHP2 and AHP3 reached V-0 rating, and AHP4 reached V-1 rating. The LOI and UL 94 test illustrate that when a moderate content of [Emim]PF6 incorporated into the TPU/AHP system, a remarkable improvement of flame retardancy was observed.
3.2 Cone calorimeter test (CCT)
Although the LOI is a useful small-scale test for high-lighting and ranking flame retardant polymers, the cone calorimeter test (CCT) provides a wealth of information on the combustion behavior under ventilated conditions.35 The CCT is based on oxygen consumption principle, it truly simulates the combustion of the polymers in a real fire situation, showing great important significance in the research and development of new flame-retardant materials.36–38
Heat release rate (HRR). The HRR measured by cone calorimeter is a very important parameter as it expresses the intensity of a fire. HRR curves of all samples are presented in Fig. 1. It is clear that TPU burns rapidly without any retardant, and has a single sharp peak with a peak heat release (pHRR) value of 1272.6 kW m−2, which means that the fire intensity increases rapidly. With the incorporation of flame retardants AHP, the HRR values decreased significantly. For TPU/AHP sample, the pHRR value is 105.7 kW m−2 appeared at about 60 s, and decreased by 91.65% than that of neat TPU. Then after the first peak, the HRR reduced to below 10 kW m−2 rapidly, and later the second peak appeared, with the value of 104.4 kW m−2. The first peak is due to the decomposition of AHP to release some phosphoric acid and poly phosphoric acid,19 which promoted the formation of intumescent carbon layer as a physical barrier and increasing the difficulty of mass and heat transfer. The latter peaks are due to the fact that the heat broken through the intumescent carbon layer when polymers are continuous exposed to strong thermal radiation of the cone. When a proper content of [Emim]PF6 was incorporated into TPU/APP system, the HRR value further decreased. From Fig. 1, it can be seen that the first pHRR values of TPU/AHP/[Emim]PF6 are a little higher than that of TPU/AHP, it may be due to the ionic liquid [Emim]PF6 catalysis that promoted AHP and TPU matrix decomposition to releases some combustible gases at the initial of the combustion process.28,30 However, later the HRR values of AHP-2 and AHP-3 are apparent lower than that of TPU/AHP composites, especially at the time 100 s to 200 s, there is hardly heat release for the two samples. It suggests that the carbon layer is so dense and compact during the time that prevents the flammable gases released into the flame zone and the outside oxygen into the inside of polymer. As for AHP-4 with 0.125 wt% [Emim]PF6, the HRR curve is similar to that of AHP-1, and the HRR value is even higher, which illustrates that excessive amount of [Emim]PF6 goes against catalytic effect for TPU/AHP composites.
 |
| Fig. 1 Heat release rate of TPU composites at a flux of 35 kW m−2. | |
The synergistic effect of [Emim]PF6 on TPU/AHP system may be explained as follows: (1) the ionic liquid [Emim]PF6 can be well dispersed in TPU matrix as the organic phase, the phosphorus and fluorine element in ionic liquid [Emim]PF6 themselves have good flame retardancy; (2) both [Emim]PF6 and AHP can accelerate the cross-linking and char forming reaction of TPU by generating polyphosphoric acid and phosphorus oxide, and enhanced the structure and intensity of carbon layer as a good physical barrier.
Total heat release (THR). THR values represent the fire load of combustion under the test conditions,37 and the slope of the THR curves can be assumed to be representative of fire spread.39 Fig. 2 presents THR curves of all samples at a flux of 35 kW m−2. It is clear that the THR values and the slope of the THR curves significantly decrease with the addition of AHP and [Emim]PF6, TPU > AHP-4 > AHP-1 > AHP-2 > AHP-3. Among all samples, AHP-3 containing 0.0625 wt% [Emim]PF6 shows the lowest THR value and slope (decreased by 67.8% compared with that of neat TPU). It is suggested that there is an obvious improvement of flame retardancy between AHP and [Emim]PF6 in TPU composites. However, when the content of [Emim]PF6 increases to 0.125 wt%, the THR value is higher than that of AHP-1, but still much lower than that of neat TPU. It may be due to the fact that, when the content of [Emim]PF6 increased to 0.125 wt%, the catalytic role strengthen and promote the decomposition of polymer matrix, thus releasing more heat.
 |
| Fig. 2 Total heat release of TPU composites at a flux of 35 kW m−2. | |
MASS. An intumescent carbon layer may form on the surface of the materials during combustion, creating a physical protective barrier to restrain heat and mass transfers. The carbon layer would limit the oxygen diffusion into the underlying part of the material or isolate from heat and combustible gases, and further retard the pyrolysis of material.6 Fig. 3 presents the MASS curves for all TPU composites. It is very clear that the MASS of neat TPU decreases rapidly without any retardant, and only 7.04% mass residue. Whereas, with the incorporation of flame retardants AHP and IG, the mass residue of samples significantly increases, and the mass loss curves become more slowly and shows a low mass loss rate, which is in line with the behaviors of HRR curves, the mass residues are 46.81%, 58.33%, 59.62%, 40.32%, respectively. It can be ascribed to the formation of intumescent carbon layers on the surface of the materials during combustion, creating a physical protective barrier to restrain heat and mass transfer,40 and AHP-3 containing 0.125 wt% [Emim]PF6 shows the smallest mass loss rate and most mass residue. This can be concluded that [Emim]PF6 can improve the char residue weight in the combustion process. This result also means that there is catalyzing carbonization effect by [Emim]PF6 in the TPU/AHP system.
 |
| Fig. 3 Mass loss curves of TPU composites at a flux of 35 kW m−2. | |
Smoke production rate (SPR). Smoke performance of flame-retardant composites is a significant parameter in fire safety fields. The SPR curves of all samples are presented in Fig. 4. The peak SPR value (pSPR) of TPU is 0.069 m2 s−1. It is clearly seen that a significant decrease of the peak SPR value taken on with the addition of flame retardants. The peak SPR value of AHP-1 containing only AHP is greatly decreased, compared with that of neat TPU. However the time to reach peak SPR of flame-retardant TPU, is ahead of schedule than that of neat TPU, which may be attributed to the decomposition of AHP at low temperature to form some smoke particulates. Moreover, after adding 0.0625 wt% [Emim]PF6, the SPR value further decreases than that of TPU/AHP composites, especially at the time 100 s to 200 s, the SPR value is less than 0.005 m2 s−1 and the curve is very gentle. Such phenomenon can be described as follows, during combustion process, with the addition of AHP, an intumescent carbon layer was formed as a physical barrier, which can restrain the release of pyrolysis gases and smoke particle efficiently. Furthermore, a proper content of ionic liquids play a role of catalytic effect, which helps to promote charring and change the carbon layer structure, and thereby enhances the physical barrier effect. And the carbon layer still keeps good structure when continues exposed to strong thermal radiation.
 |
| Fig. 4 Smoke production rate of TPU composites at a flux of 35 kW m−2. | |
Total smoke release (TSR). Fig. 5 presents TSR curves of all samples at a heat flux of 35 kW m−2. It is clear that the TSR curves of flame-retardant TPU composites are much lower than that of TPU. For neat TPU, the TSR value is 754.05 m2 m−2, and from AHP-1 to AHP-4, the TSR values are 451.48, 378.77, 348.75 and 569.15 m2 m−2, respectively. Among all samples, AHP-3 containing 0.0625 wt% [Emim]PF6 shows the lowest TSR value, decreased by 53.75% compared with that of neat TPU.
 |
| Fig. 5 Total smoke release of TPU composites at a flux of 35 kW m−2. | |
Smoke factor (SF). SF value is the product of PHRR and TSP.41 The SF curves of all TPU composites under CCT are presented in Fig. 6. The SF value of neat TPU is up to 959.3 MW m−2, and the value of AHP-1 containing only AHP is just 48.2 MW m−2. It is very clear that the addition of flame retardant significantly reduces the SF values of TPU composites. Furthermore, TPU/AHP system with 0.0625 wt% [Emim]PF6 presents the lowest SF value, 44.83 MW m−2. This indicates the same conclusion as drawn from the above results of HRR and TSR.
 |
| Fig. 6 Smoke factor of TPU composites at a flux of 35 kW m−2. | |
Digital photos of carbon residue. The digital photos of char residues after CCT for all samples are shown in Fig. 7. The formation of an efficient carbon layer can prevent the heat an mass transfer between flame zone and burning substrate, and thus protect the underlying materials from further burning and pyrolysis of polymer composites.5 It is clear that the char residue of TPU is the lightest and loosest responding to the highest HRR and the least mass residue among all samples. This means that the viscosity of molten carbon layer cannot effectively bind the volatile substances during combustion process, resulting large amount of heat and smoke release. AHP-1 containing only AHP has relatively high and compact char residue. Moreover, with a low addition of ionic liquid [Emim]PF6 (0.03125 wt% and 0.0625 wt%), the char layer become further more dense and higher. However, when the content of [Emim]PF6 is up to 0.125 wt%, the residue char layer is not so good, and there are some collapses in the carbon layer.
 |
| Fig. 7 Digital photographs of char residues after CCT for all samples. | |
3.3 Smoke density test (SDT)
The smoke density test gives detailed information about the smoke production. Fig. 8(A and B) presents the luminous flux curves of all TPU composites with flame and without flame, respectively. It is clear from the figure that luminous flux decreases with the addition of AHP and [Emim]PF6 at the beginning of the test process (about 0–100 s for with flame and about 75–250 s for without flame). It means that the smoke density of AHP-1, AHP-2, AHP-3, and AHP-4 are higher than that of TPU during that time, which indicates that an early decomposition of the flame retardants occurs. The early decomposition of the flame retardants is necessary to increase the fire-proofing properties of the material. The samples with both AHP and [Emim]PF6 decompose earlier than AHP-1, which may be due to the fact that the ionic liquid [Emim]PF6 catalyzes to promote TPU/AHP system decompose at low temperature to form phosphorus oxide. However, after 100 s for with flame condition and after 250 s for without flame condition, the luminous flux curves of flame-retardant samples become much lower than that of neat TPU, which means less smoke density is observed for AHP-1 to AHP-4. And, at the end of the test (1200 s), AHP-3 containing 0.0625 wt% [Emim]PF6 has the highest luminous flux.
 |
| Fig. 8 Luminous flux curves of TPU composites with flame (A) and without flame (B). | |
3.4 Thermogravimetric analysis (TG)
TG is one of the most widely techniques used for evaluating thermal stability of different materials.6,42,43 TG and Derivative TG (DTG) curves of various flame retardant TPU composites under nitrogen atmosphere are shown in Fig. 9(A and B). As is known that, thermal degradation of TPU has two steps: the first step is responsible for the rupture of the TPU main chains, and the second step is attributed to the further destruction of the C–C and C–O bonds on the main chain.40 For TPU, the temperature at 5% mass loss (T−5%, taken as the onset of the degradation) is 330.1 °C, the maximum weight loss temperature (T−max) of TPU is 428.5 °C, and only 12.91% char residue remains at 700 °C. In the case of flame-retardant TPU composites, the T−5% is about 285–301 °C, and the T−max is about 380.6 °C, which is lower than that of TPU. Moreover, it is apparent that the thermal degradation of flame-retardant TPU composites comprises three steps corresponding to the temperatures of about 313, 378, and 469 °C. As usual, the three thermal degradation steps are identified as the decomposition of AHP,19 catalysis of the charring process, and further decomposition of the C–C and C–O bonds on the main chain of TPU. It can be seen that the addition of flame retardants reduces the temperature of the formation for carbon layer, so that it protects the TPU composites from further thermal degradation and combustion.44 As for the samples containing [Emim]PF6, the degradation of TPU composites is promoted at an earlier at an earlier period but is delayed at a later period than that of AHP-1. It can be explained by the fact that [Emim]PF6 as a kind of catalyst would promote the decomposition of AHP and the formation of protective carbon layer which results in lower decomposition temperature of the samples, and also induces the cross-linking reaction in PP composites at higher temperatures, improving the thermal stability of TPU composites. Compared with AHP-1, the mass residue at 700 °C of the samples with a moderate content of [Emim]PF6 is more, and AHP-3 has the most mass residue (41.71%), which is consistent with MASS values under CCT.
 |
| Fig. 9 TG (A) and DTG (B) curves of TPU composites at a constant heating rate of 20 K min−1. | |
3.5 Thermogravimetric analysis/infrared spectrometry (TG-IR)
In order to further study the volatilized products of samples during thermal decomposition process, the thermogravimetric/Fourier infrared spectrum analysis (TG-IR) technique was obtained under the nitrogen atmosphere.46 The TG-IR spectra of volatilized products of TPU, AHP-1 and AHP-3 during the thermal-decomposition process from 240 to 700 °C are presented in Fig. 10, respectively. It is clear from Fig. 10 that, peaks in the regions of around 3750–3600 cm−1, around 3150–2750 cm−1, around 2400–2250 cm−1, around 1800–1700 cm−1, around 1500–1000 cm−1, and around 750–500 cm−1 are prominent. Some of the volatilized products of TPU and flame-retardant TPU composites are confirmable identified by strong characteristic FTIR signals. The main share of the bands of the decomposition products can be attributed to the functional groups with characteristic, unambiguous band positions, such as H2O at 4000–3500 cm−1, N–H at 3370 cm−1, –CH3 and –CH2– at about 3000–2800 cm−1, CO2 at 2400–2300 cm−1, C
O at 1750 cm−1.45
 |
| Fig. 10 FTIR spectra of volatilized products at various times during the thermal degradation of TPU composites. | |
It is obvious that there are significant differences among the peak position and intensity of TPU, AHP-1 and AHP-3 during the thermal degradation process. Compared with that of neat TPU, the samples AHP-1 and AHP-3 have little and small peaks in the regions of around 3370 cm−1, 3000–2800 cm−1, 2350 cm−1, 1750 cm−1, 1500–750 cm−1, which means there are little decomposition compounds releasing for the flame-retardant samples. However, as for non-flammable gases H2O and CO2, they are released at lower temperature than those of neat TPU. For example, characteristic peak of CO2 (2350 cm−1) for neat TPU appears at 340 °C and significantly decreases at about 600 °C; the peaks for AHP-1 and AHP-3 appear at 320 °C and 300 °C and decreases at 520 °C, respectively. This may be due to the fact that AHP accelerates samples to release CO2 and H2O as non-flammable gas at lower temperature, and when [Emim]PF6 is incorporated the temperature future reduced. Meanwhile the intensity of CO2 peaks for AHP-1 and AHP-3 decrease significantly at high temperature, which means the incorporation of AHP and [Emim]PF6 improves the thermal stability of samples at high temperature. Moreover, the following characteristic peaks corresponding to the gas volatile products: unsaturated C–H structure (3018 cm−1), saturated C–H structure (2950 cm−1), C
O (1750 cm−1), the frame vibration of aromatic ring (1608–1450 cm−1), C–H bending vibration of aromatic ring (1264–927 cm−1) remarkably decrease for AHP-1 and AHP-3 compared with that of neat TPU. So the incorporation of AHP and [Emim]PF6 can not only improve the thermal stability of samples at the high temperature but also reduce the release of hazardous gases such as aromatic compounds.
4. Conclusion
LOI results indicate that the addition of AHP and [Emim]PF6 increases the flame-retardant level of TPU composites obviously. Data from CCT show that AHP can significantly reduce the heat release and smoke production of TPU composites during combustion process. And, a moderate content of [Emim]PF6 can further reduce the heat and smoke parameters. The SDT results indicate that the ionic liquid [Emim]PF6 can catalyze to promote TPU/AHP system decompose at low temperature to form phosphorus oxide, and thus reduces the smoke density at high temperature. TG results show that the [Emim]PF6 can further enhance the thermal stability of TPU/AHP system by making AHP catalytic decomposition to form protective carbon layer. And TG-IR techniques show that the addition of AHP and [Emim]PF6 can reduce hazardous and toxic gases releasing, and promote to release CO2 and H2O as nonflammable gases at low temperature during thermal degradation. In summary, synergistic effect between ionic liquid [Emim]PF6 and AHP on flame-retardant TPU is significant effective, and when [Emim]PF6 content is 0.0625 wt%, there is the best flame-retardant result.
Acknowledgements
The authors gratefully acknowledge the National Natural Science Foundation of China (No. 51106078, No. 51206084), and the University Research and Development Projects Shandong Province (J14LA13).
References
- A. Frick and A. Rochman, Polym. Test., 2004, 23, 413–417 CrossRef CAS
. - B. Finnigan, D. Martin, P. Halley, R. Truss and K. Campbell, Polymer, 2004, 45, 2249–2260 CrossRef CAS
. - H. Koerner, W. Liu, M. Alexander, P. Mirau, H. Dowty and R. A. Vaia, Polymer, 2005, 46, 4405–4420 CrossRef CAS
. - U. Almeida Pinto, L. L. Y. Visconte, J. Gallo and R. C. R. Nunes, Polym. Degrad. Stab., 2000, 69, 257–260 CrossRef
. - X. Chen, Y. Jiang and C. Jiao, J. Hazard. Mater., 2014, 266, 114–121 CrossRef CAS PubMed
. - X. Chen, Y. Jiang and C. Jiao, J. Therm. Anal. Calorim., 2014, 117, 857–866 CrossRef CAS
. - U. A. Pinto, L. L. Y. Visconte and R. C. Reis Nunes, Eur. Polym. J., 2001, 37, 1935–1937 CrossRef CAS
. - L. Chen and Y. Wang, Polym. Adv. Technol., 2009, 21, 1–26 CAS
. - A. Covaci, S. Harrad, M. A. Abdallah, N. Ali, R. J. Law, D. Herzke and C. A. de Wit, Environ. Int., 2011, 37, 532–556 CrossRef CAS PubMed
. - F. Laoutid, L. Bonnaud, M. Alexandre, J. M. Lopez-Cuesta and P. Dubois, Mater. Sci. Eng., R, 2009, 63, 100–125 CrossRef
. - C. Nguyen, M. Lee and J. Kim, Polym. Adv. Technol., 2011, 22, 512–519 CrossRef CAS
. - H. Qu, W. Wu, J. Xie and J. Xu, Polym. Adv. Technol., 2011, 22, 1174–1181 CrossRef CAS
. - R. Zhang, X. Xiao, Q. Tai, H. Huang and Y. Hu, Polym. Eng. Sci., 2012, 52, 2620–2626 CAS
. - B. Wang, X. Wang, G. Tang, Y. Shi, W. Hu, H. Lu, L. Song and Y. Hu, Compos. Sci. Technol., 2012, 72, 1042–1048 CrossRef CAS
. - S. Nie, M. Zhang, S. Yuan, G. Dai, N. Hong, L. Song, Y. Hu and X. Liu, J. Therm. Anal. Calorim., 2011, 109, 999–1004 CrossRef
. - U. Braun, B. Schartel, M. A. Fichera and C. Jäger, Polym. Degrad. Stab., 2007, 92, 1528–1545 CrossRef CAS
. - W. Yang, R. K. K. Yuen, Y. Hu, H. Lu and L. Song, Ind. Eng. Chem. Res., 2011, 50, 11975–11981 CrossRef CAS
. - Q. Li, B. Li, S. Zhang and M. Lin, J. Appl. Polym. Sci., 2012, 125, 1782–1789 CrossRef CAS
. - G. Tang, X. Wang, W. Xing, P. Zhang, B. Wang, N. Hong, W. Yang, Y. Hu and L. Song, Ind. Eng. Chem. Res., 2012, 51, 12009–12016 CrossRef CAS
. - S. Xiao, M. Chen, L. Dong, C. Deng, L. Chen and Y. Wang, Chin. J. Polym. Sci., 2013, 32, 98–107 CrossRef
. - Y. Shen, W. Gong, B. Zheng, X. Meng and L. Gao, Polym. Degrad. Stab., 2016, 129, 114–124 CrossRef CAS
. - C. Ma, J. Yu, B. Wang, Z. Song, J. Xiang, S. Hu, S. Su and L. Sun, Fuel Process. Technol., 2016 DOI:10.1016/j.fuproc.2016.01.018
. - X. Wang, Y. Song and J. Bao, J. Vinyl Addit. Technol., 2008, 14, 120–125 CrossRef CAS
. - J. Wu, Y. Hu, L. Song and W. Kang, J. Fire Sci., 2008, 26, 399–414 CrossRef CAS
. - B. Du, Z. Guo, P. A. Song, H. Liu, Z. Fang and Y. Wu, Appl. Clay Sci., 2009, 45, 178–184 CrossRef CAS
. - C. Xiao, X. Chu, B. Wu, H. Pang, X. Zhang and J. Chen, Talanta, 2010, 80, 1719–1724 CrossRef CAS PubMed
. - T. Welton, Mod. Chem. Ind., 2001, 35, 2625–2633 Search PubMed
. - T. Welton, Chem. Rev., 1999, 99, 2071–2084 CrossRef CAS PubMed
. - S. Chen, C. Wang and J. Li, Thermochim. Acta, 2016, 631, 51–58 CrossRef CAS
. - S. Chen, J. Li, Y. Zhu, Z. Guo and S. Su, J. Mater. Chem. A, 2013, 1, 15242–15246 CAS
. - Z. Shao, C. Deng, Y. Tan, M. Chen, L. Chen and Y. Wang, ACS Appl. Mater. Interfaces, 2014, 6, 7363–7370 CAS
. - S. Li and X. Dang, Polym. Bull., 2010, 11, 76–83 Search PubMed
. - Y. Li, G. Wang, J. Ye and Y. Li, Polyurethane Ind., 2012, 27, 5–8 Search PubMed
. - Y. Li, Z. Gui and J. Ye, Fire Sci. Technol., 2013, 32, 192–194 CAS
. - D. Price, K. Pyrah, T. R. Hull, G. J. Milnes, J. R. Ebdon, B. J. Hunt and P. Joseph, Polym. Degrad. Stab., 2002, 77, 227–233 CrossRef CAS
. - W. H. Park and K. B. Yoon, J. Therm. Sci., 2013, 22, 168–173 CrossRef CAS
. - B. Schartel and T. R. Hull, Fire Mater., 2007, 31, 327–354 CrossRef CAS
. - X. Wang, Y. Li, W. Liao, J. Gu and D. Li, Polym. Adv. Technol., 2008, 19, 1055–1061 CrossRef CAS
. - C. M. Jiao and X. L. Chen, Plast., Rubber Compos., 2010, 39, 445–448 CrossRef CAS
. - M. Lin, B. Li, Q. Li, S. Li and S. Zhang, J. Appl. Polym. Sci., 2011, 121, 1951–1960 CrossRef CAS
. - M. R. Ricciardi, V. Antonucci, M. Zarrelli and M. Giordano, Fire Mater., 2012, 36, 203–215 CrossRef CAS
. - X. Chen, C. Jiao, S. Li and Y. Hu, Fire Saf. J., 2013, 58, 208–212 CrossRef CAS
. - X. Chen and C. Jiao, Polym. Degrad. Stab., 2008, 93, 2222–2225 CrossRef CAS
. - M. Kannan, S. S. Bhagawan, S. Thomas and K. Joseph, J. Therm. Anal. Calorim., 2012, 112, 1231–1244 CrossRef
. - X. Chen, L. Huo, C. Jiao and S. Li, J. Anal. Appl. Pyrolysis, 2013, 100, 186–191 CrossRef CAS
. - N. Wu and Z. Xiu, RSC Adv., 2015, 5, 49143–49152 RSC
.
|