Open Access Article
Johnny Nguyena,
Sonia Conterab and
Isabel Llorente García*a
aDepartment of Physics and Astronomy, University College London, Gower St., London WC1E 6BT, UK. E-mail: i.llorente-garcia@ucl.ac.uk
bClarendon Laboratory, Dept. of Physics, University of Oxford, OX1 3PU, UK
First published on 20th April 2016
We demonstrate, for the first time, confinement of the orientation of micron-sized graphitic flakes to a well-defined plane. We orient and rotationally trap lipid-coated highly ordered pyrolytic graphite (HOPG) micro-flakes in aqueous solution using a combination of uniform magnetic and AC electric fields and exploiting the anisotropic diamagnetic and electrical properties of HOPG. Measuring the rotational Brownian fluctuations of individual oriented particles in rotational traps, we quantitatively determine the rotational trap stiffness, maximum applied torque and polarization anisotropy of the micro-flakes, as well as their dependency on the electric field frequency. Additionally, we quantify interactions of the micro-particles with adjacent glass surfaces with various surface treatments. We outline the various applications of this work, including torque sensing in biological systems.
In this paper, we demonstrate, for the first time, confinement of the orientation of graphitic micro-flakes to a well-defined plane using a novel magneto-electrical approach for fully controlling micro-particle orientation. We orient and rotationally trap soluble, biocompatible, lipid-coated micro-particles of highly ordered pyrolytic graphite (HOPG) in aqueous solution. Our scheme takes advantage of the anisotropic diamagnetic and electrical properties of HOPG micro-flakes (graphene layer stacks)12 to orient them parallel to a plane defined by two perpendicular fields: a vertical static magnetic field (∼240 mT); and a horizontal, linearly polarized electric field (∼2 × 104 V m−1) oscillating at frequencies above 10 MHz. Our inexpensive set-up is made from one permanent magnet and two thin wire electrodes, involving no micro-fabrication. While we demonstrate our scheme on HOPG, the impact of our results extends to other forms of carbon-based micro/nano-particles.
Current methods for large-scale vertical orientation of graphene-based particles such as, for instance, vacuum filtration8 and chemical vapour deposition,13 are involved and costly and do not provide full control of graphene plane orientation. As for magnetic and electrical orientation methods, only a handful of publications have reported the magnetic alignment of graphite/graphene micro/nano-particles in solution,1,2,6,14 and the use of electric fields to orient these particles has turned out to be more challenging than originally expected. Only very recently, the use of alternating-current (AC) electric fields has been reported as a successful method for the orientation of graphite/graphene flakes3–5 and carbon nanotubes.15,16 However, these methods also lack full control of particle orientation, since the use of a single orienting field (either magnetic or electric) still allows particles to freely rotate around the field direction.
Our results present a number of key novelties with respect to previous work. By simultaneously applying magnetic and AC electric fields in different directions, we restrict micro-particle rotations and confine particle orientation to the plane defined by these fields. Furthermore, we track and analyse the rotational motion of individual micro-particles, as opposed to monitoring ensemble averages. We detect micro-particle orientation using robust image processing techniques which improve the detection accuracy in comparison to indirect methods reported in previous studies.3–5 By tracking the rotation of the particles and analyzing their Brownian orientational fluctuations around equilibrium in the rotational traps, we quantitatively determine the rotational trap stiffness, maximum applied orientational torques and relevant polarization anisotropy factor for the micro-flakes, as well as how these depend on the frequency of the AC electric field. This is the first report of such measurements for lipid-coated HOPG micro-flakes. Additionally, we quantitatively characterize the interaction of the micro-flakes with nearby functionalized glass surfaces, reliably discriminating this interaction from the effect of the orienting fields in our analysis, and potentially opening a new route to measuring the strength of interfacial interactions. Crucially, rotational trapping (confinement to a plane) allows the powerful use of Brownian fluctuation analysis methods which enable precise quantitative measurements that cannot be found in previous studies.
Our achievement of controlled orientation paves the way for advances in a wide range of applications. As well as the applications mentioned above, the manipulation of individual biocompatible graphitic micro-particles can open up new exciting possibilities for biological and chemical sensing,17–19 and for fundamental biophysical and biochemical studies. Indeed, our ability to detect weak torques shows that our scheme could be applied to the precise sensing of biologically relevant torques. Our experiments contribute to the currently growing interest in the diamagnetic manipulation of micro/nano-particles,20 particularly within a biological context, where most matter is diamagnetic. The recent demonstration of magnetically controlled nano-valves21 is one excellent example of the enormous potential of diamagnetic manipulation.
We define a fixed laboratory frame of reference with axes (X, Y, Z), where Z is the vertical direction (Fig. 1). The static magnetic field B0 is along Z and the electric field E0 oscillates along the horizontal X direction. We also define a particle frame of reference with axes (x, y, z) fixed to the HOPG particle. The x–y plane corresponds to the HOPG graphene planes and z is normal to the graphene planes.
The magnetic manipulation of micro-particles in solution presents the advantages of being contactless, non-invasive, biocompatible, largely insensitive to the solvent's conductivity, ionic strength and pH, not accompanied by undesirable effects in solution (such as electrophoretic migration or electrochemical reactions in electro-manipulation), and cheap and simple thanks to the availability of strong NdFeB permanent magnets.20
The effective induced magnetic moment that a particle with magnetic susceptibility tensor χ2, immersed in a fluid with magnetic susceptibility tensor χ1, experiences in the presence of a uniform, static magnetic field, B0, is:25
![]() | (1) |
![]() | (2) |
The direction of the magnetic field B0 in the particle frame is specified by the spherical polar angles (θ, ϕ), with θ being the angle with respect to z and ϕ being the angle that the projection of B0 onto the x–y plane makes with the x axis [see Fig. 1(a)]. We can therefore write B0 = B0(sin
θ
cos
ϕ
+ sin
θ
sinϕŷ + cos
θẑ), where B0 is the amplitude of the applied magnetic field. In the presence of this field, the particle experiences a magnetic torque
m = meff × B0. The only non-zero components of this torque are
mx and
my, so that the particle will rotate around an in-plane axis until it reaches orientational equilibrium. The net magnetic torque around the in-plane (∥) axis is given by:
![]() | (3) |
Note that this torque relies on the intrinsic magnetic anisotropy of the particles [(χ⊥ − χ∥) ≠ 0] and is independent of the magnetic susceptibility of the surrounding fluid. The torque depends on the orientation of the graphene planes with respect to the applied field and on particle volume, but is independent of particle shape. This key aspect makes diamagnetic manipulation extremely versatile and powerful. Interestingly, the absolute value |χ⊥ − χ∥| for HOPG increases with decreasing temperature.22,26,27
The magnetic potential energy can be expressed as:
![]() | (4) |
The orientations of stable rotational equilibrium which satisfy ∂Um/∂θ and ∂2Um/∂θ2 > 0 depend on the sign of the particle's magnetic anisotropy (χ⊥ − χ∥), so that for diamagnetic HOPG, with (χ⊥ −χ∥) < 0 and χ⊥ < χ∥ < 0, the equilibrium orientations correspond to θ = ±90°. Therefore, the HOPG flakes rotate until their graphene planes align parallel to the direction of the applied magnetic field, in order to minimize the magnetic interaction energy, as depicted in Fig. 1(a).
The surrounding fluid has the effect of opposing the rotation of the particles through the contributions of rotational viscous drag and thermal rotational Brownian fluctuations. The magnetic field in our experiments (B0 ∼ 240 mT) is strong enough to overcome these contributions so that HOPG micro-particles can be quickly magnetically aligned and stably maintained into a vertical orientation.
Our HOPG micro-flakes are coated with a phospholipid layer to facilitate dispersion in aqueous solution. Phospholipid molecules are also diamagnetically anisotropic and tend to align perpendicular to applied magnetic fields, as evidenced by the magnetic deformation of phospholipid bilayers and liposomes in strong magnetic fields (>4 T).20,28–30 We neglect magnetic effects on our lipid layers given that we use modest magnetic fields up to 0.3 T, that the magnetic anisotropy of similar phospholipid molecules29,30 is two orders of magnitude lower than the value of (χ⊥ − χ∥) for HOPG, and that lipid layers on our particles are ∼100 times thinner than the HOPG particle size. Note that, by contrast, the lipid layer plays a major role in the AC electrical orientation of the HOPG particles, as detailed in the following section.
, where ε and σ are the relevant static relative permittivity and conductivity, respectively, ε0 is the permittivity of free space and ω = 2πf is the angular frequency of the applied AC electric field). The reader can refer to Asami et al.31 for details of how Laplace's equation can be solved to find out the electrical potential outside a layered ellipsoid in order to derive the effective dipole moment of the submerged particle and its dependency on the frequency of the AC electric field (see also Section 3.5 for an intuitive explanation of how this frequency dependency arises). The effective electric dipole moment components for a layered ellipsoid can be expressed as:| peff,k(t) = V2ε1ε0KkE0k(t), | (5) |
e = peff × E0.
In our experiments, E0 is applied once the micro-flakes have been pre-aligned with the vertical magnetic field. E0 is linearly polarised along the horizontal X direction and makes an angle α to the z axis [see Fig. 1(b)], so that E0 = E0(sin
α
+ cos
αẑ), where E0 is the field amplitude. In the presence of this field, the particles feel a time-averaged electric torque around the in-plane y direction, of the form:
![]() | (6) |
![]() | (7) |
Hence, we can write
e∥ = −
emax
sin(2α). Analogously to eqn (4), the electric interaction potential energy is:
![]() | (8) |
For the parameters in our experiments, with Re[K⊥ − K∥] < 0 and Re[K∥] > Re[K⊥] > 0, stable rotational equilibrium takes place for orientation angles α = ±90°, i.e., particles rotate until their graphene planes align parallel to the applied electric field direction. Once aligned, the particles are rotationally trapped as long as the electric field is on. For small-angle deviations from orientational equilibrium, the rotational trap can be considered approximately harmonic, i.e.,
e∥(α) = −
emax
sin(2α) ≈ −keα, where ke = 2
emax is the electrical rotational trap stiffness.
![]() | ||
| Fig. 2 Schematic of experimental set-up. The magnet generates a vertical magnetic field along Z. The wires generate a horizontal electric field along X. HOPG micro-flakes are vertically oriented parallel to the X–Z plane by the magnetic and electric fields as shown in the zoomed-in view and in more detail in Fig. 1. Micro-flake rotation is imaged from above the sample with a microscope onto a CCD camera (image plane parallel to X–Y plane). | ||
We have carried out measurements of magneto-electrical orientation on 10 individual lipid-coated HOPG particles with a narrow spread of particle sizes and shapes and with average dimensions ∼2 μm × 4 μm × 7 μm (0.5 μm standard deviations, see Appendix B). The vertical Z position of all micro-flakes imaged in experiments is approximately the same, with variations of order 0.5 μm.
e∥ = −
emax
sin(2φ) [see eqn (6)], with orientational equilibrium corresponding to φ = 0°.
The particle-rotation video sequences are analyzed using automated image processing algorithms in Matlab, in order to extract φ and the particle dimensions as described in Appendix B. This reproducible detection of the particle's orientation represents an improvement with respect to alternative indirect methods reported in the literature3–5 based on light-transmission levels through graphitic micro-particle dispersions.
emax and polarization anisotropy factor Re[K∥ − K⊥] for the HOPG micro-flakes as a function of frequency. This analysis reveals the presence of weak interactions between the micro-particles and the nearby glass surface, which we also quantify to discriminate their effect from that of the electric torque.
All experiments are carried out in the presence of the vertical magnetic field B0 ≈ 0.24 T. The maximum orienting magnetic torque [V2B02(χ⊥ − χ∥)/(2μ0) in eqn (3)] applied to the particles is ∼2.4 × 10−16 Nm, calculated for HOPG particles with average size ∼2 μm × 4 μm × 7μm using the values of χ∥ and χ⊥ given in Section 2.1. This strong magnetic torque is two orders of magnitude larger than the applied electric torque (see measurements below) and is crucial to ensuring our micro-flakes stay vertically aligned throughout the course of electro-orientation experiments.
![]() | ||
| Fig. 4 Measured rotation of a single HOPG micro-flake during electro-orientation. The electric field is turned on at t = 0. The micro-flake rotates until it aligns with the electric field direction (φ ≈ 0°). Data shown for electric field frequencies: 20 MHz, 40 MHz and 60 MHz, with E0 ∼ 2 × 104 V m−1. Solid lines: fits to eqn (10). | ||
The equation of motion for the electro-orientation of the micro-particles in solution is given by the balance of torques:
![]() | (9) |
e∥ is the applied electric torque [
e∥ = −
emax
sin(2φ), see eqn (6) and (7)]. The last term in eqn (9) corresponds to the stochastic rotational Brownian fluctuations at temperature T, where kB is Boltzmann's constant and W(t) is a random variable with Gaussian distribution of zero mean and unity variance.
The inertial term I∥
in eqn (9) can be neglected in comparison to the viscous drag term −C∥
. As a first approximation, we can neglect rotational Brownian fluctuations and solve C∥
= −
emax
sin(2φ) to find an analytical expression for the evolution of the micro-flake orientation in time:
![]() | (10) |
emax could be extracted from these fits using calculated values for C∥ (see Appendix D). However, we use a more accurate method which does not rely on pre-calculated C∥ values, as described in the following sub-section.
emax, ke and Re[K∥ − K⊥] at different electric field frequencies. Considering the effect of rotational Brownian fluctuations is essential in order to detect weak torques in environments dominated by thermal fluctuations. The Brownian motion of ellipsoidal particles was first theoretically described in 1934 by Perrin,36 but was not experimentally verified until 2006.37
The orientational fluctuations of the micro-flakes as they stay aligned with the electric field are monitored for 20–30 seconds. The electric field is then turned off and particles are recorded for a further 20–30 seconds to monitor their free rotational fluctuations in the absence of the electric field. Angular fluctuations derived from the measured video recordings are shown in Fig. 5 for a single HOPG micro-flake at ∼23 °C. Data corresponding to electric field frequencies 20 MHz, 40 MHz and 60 MHz are presented, together with data in the absence of the electric field. Fluctuations are clearly smaller in amplitude when the electric field is on, and decrease with increasing field frequency, as shown by the histograms on the right-hand side, evidencing rotational trapping and successful alignment.
The mean square angular displacement (angular MSD) is defined as 〈[Δφ(τ)]2〉, where Δφ(τ) = φ(t0 + τ) − φ(t0) are the orientational fluctuations over a time interval τ and t0 is the initial time. The angle brackets indicate averaging over all initial instants. For the case of free (untrapped) rotational diffusive behaviour, the angular MSD should depend linearly on τ as 〈[Δφ(τ)]2〉 = 2Dφτ, where Dφ = kBT/C∥ is the corresponding rotational diffusion coefficient.36 In the presence of rotational trapping, the angular MSD deviates from this linear behaviour. This is shown in Fig. 6(a), where the measured angular MSD corresponding to the orientational fluctuation data in Fig. 5 is presented.
![]() | ||
| Fig. 6 (a) Angular MSD (data points and envelope for error bars) for the orientational fluctuation data shown in Fig. 5. (b) Auto-correlation [data points and fits to eqn (13)] for the same fluctuation data. | ||
The non-linearity of the angular MSD due to rotational trapping is observed even when the electric field is off [Fig. 6(a)]. This is due to the fact that particles fall under gravity and interact non-negligibly with the nearby glass surface in a way that opposes their rotation. Both the small effect of these interactions with the glass and the strong alignment in the presence of the AC electric field are described theoretically as rotational traps with trap stiffness kglass and ke, respectively. For small-angle fluctuations, the electrical rotational trap is approximately harmonic so that
e∥(φ) = −
emax
sin(2φ) ≈ −keφ, with ke = 2
emax. A similar assumption is made for the trap due to interactions with the glass. Hence, the full equation of rotational motion becomes:
![]() | (11) |
![]() | (12) |
![]() | (13) |
The angular MSD data in Fig. 6(a) shows how the measured asymptotic values at long lag times [pre-factor 2kBT/ktotal in eqn (12)] decrease with increasing electric field frequency, indicating increased rotational trap stiffness and electric torques at higher frequencies. The corresponding measured auto-correlation R(τ) is shown in Fig. 6(b). The same trend of increasing trap stiffness with frequency is evidenced by the faster exponential decay and lower R(τ = 0) values observed at higher frequencies, as given by eqn (13).
emax = ke/2.For a given micro-flake, approximately five measurements are taken at a given frequency, which are averaged to obtain mean and standard deviation values at that frequency. The standard errors of the mean are used as error bars. The process is repeated for different frequencies in order to investigate the frequency dependency of the electric torque, which follows from eqn (7). Results are then corrected for the voltage variations with frequency that originate from the RF source and impedance mismatch effects explained in Section 3.6 and Appendix C.
Fig. 7(a) shows values of ke and kglass versus frequency for the electro-orientation of an individual lipid-coated HOPG micro-flake in solution near a glass surface passivated with polyethylene glycol (PEG)-silane. PEGylation, i.e., the coating of a surface with largely non-interacting PEG polymer chain brushes, is a well known technique for surface passivation.41 The resulting kglass is low and approximately constant in time (independent of frequency, as expected), which enables the reliable characterisation of interactions between micro-particle and glass. The electric rotational trap stiffness ke, and therefore
emax, decrease with decreasing frequency due to the electrically insulating effect of the lipid coating at low to medium frequencies. Data for the maximum electrical torque
emax measured for 10 different micro-flakes are presented in Fig. 7(b), including the overall mean and standard error for all measurements. Given the narrow spread of particle sizes and shapes chosen for our experiments, the trend with frequency remains clearly visible. From the 10 particles measured, 3 were on PEG-silane passivated glass slides, 4 on plasma cleaned slides and 3 on untreated glass.
In Fig. 7(b), the measured average
emax is in the range 0–0.6 × 10−18 Nm, depending on the applied electric field frequency, corresponding to an average torsional stiffness (ke) range of 0–1.2 × 10−18 Nm rad−1. In the theoretical expression for
emax in eqn (7), we have a frequency-independent pre-factor, V2ε1ε0E02/4, multiplying the frequency-dependent polarization anisotropy factor Re[K∥ − K⊥]. The pre-factor evaluates to ∼2 × 10−18 Nm, calculated using V2 = 4πabc/3 for our particles modeled as ellipsoids with semi-axis lengths a = 1 μm, b = 2 μm and c = 3.5 μm on average, ε0 = 8.85 × 10−12 F m−1, ε1 ≈ 80 for 20 mM NaCl at 23 °C (ref. 42) and E0 = 2 × 104 V m−1. Using the
emax measurements in Fig. 7(b) and this calculated pre-factor, we obtain a polarization anisotropy factor in the range ∼0–0.3 for our lipid-coated HOPG micro-flakes, for frequencies in the range 10–70 MHz. This is indicated by the right-hand-side axis in Fig. 7(b) and is a useful measurement for a number of HOPG electro-manipulation experiments.25
The reproducible frequency dependence of the orientational torque on the micro-flakes is a useful feature which enables frequency-control of micro-particle orientation for numerous applications. The turnover frequency at which electric torque values begin to increase can be altered, for instance, by modifying the thickness of the insulating lipid layer on the micro-flakes, the conductivity of the solution or the micro-flake aspect ratio, opening interesting control possibilities.
kglass is determined from the above mentioned measurements of rotational Brownian fluctuations acquired in the absence of the electric field as explained in the previous paragraphs in Section 4.2. Results for kglass from 282 measurements for 10 different particles on untreated glass, plasma-cleaned glass and PEG-silane passivated glass are compared in the histograms shown in Fig. 8. The histograms present clear differences, with PEG-silane passivation leading to the lowest kglass mean and spread values, i.e., to the weakest rotational trapping due to surface sticking. Untreated glass shows a wider distribution of kglass values than PEG-silane treated glass. Plasma-cleaned slides show an even larger kglass spread, as expected by the generation of charged groups on the glass surface during the plasma cleaning process. While measurements have been carried out using 10 different particles with a narrow spread of particle sizes and shapes (see Appendix B), differences in particle geometry and the various possible values of glass-particle contact area throughout the measurements contribute to the spread of the measured kglass values.
Our results demonstrate, for the first time, confinement to a well-defined plane of the orientation of graphitic micro-flakes in solution, with this new method exploiting the electrical and diamagnetic anisotropy of the particles via the application of simultaneous perpendicular magnetic and electric fields. The combination of magnetic and electric fields in different configurations can open up new ways of manipulating graphitic micro/nano-particles for their orientation, confinement and transport,25,43 with the use of time-varying fields enabling frequency-control of the magneto-electrical manipulation. The principles of our method extend to other carbon-based micro/nano-particles, such as graphene platelets or carbon-nanotubes, and our scheme has great potential for being scaled down via micro-fabrication. Alternative schemes could be devised to orient and confine graphitic micro-flakes to a plane making use of rotating electric/magnetic fields, or of fast time-switching between fields in two perpendicular directions, as demonstrated e.g. for the orientation of diamagnetic, anisotropic polymer and cellulose fibers.44,45
Applications in biochemistry and biological and medical physics are particularly relevant to our experiments. Our lipid-coated HOPG micro-particles are biocompatible and our results in NaCl aqueous solution easily extend to biocompatible solutions. Our particles can be functionalized and specifically bound to biomolecules such as antibodies, protein complexes and nucleic acids, and the lipids can be fluorescently labeled or conjugated to polymers, for instance to change the electrical properties of the coating.46 HOPG micro-particles of regular sizes could be generated using current micro-fabrication techniques, such as ion-beam milling. Our particles hence constitute a promising tool with the potential to function as carriers, labels or specific targets for biological and chemical sensing applications.17–19,47 Cells could be attached onto HOPG micro-plates which could be manipulated for versatile cell-to-cell interaction experiments, such as those involving immune response, virus transfer, neuron activity, etc. As another example, given their capability of absorbing infra-red light, graphitic micro-particles could also be good candidates for photo-thermal cell therapy (e.g. for cancer treatment) or for temperature-jump studies in vitro/in vivo.
Furthermore, our HOPG micro-particles in calibrated rotational traps of known torsional trap stiffness could be used for sensing biologically relevant torques. These are typically in the range 0.01–1 × 10−18 Nm (ref. 48) (e.g. 0.02–0.08 × 10−8 Nm for ATP synthase (F1-ATPase)49 or ∼0.01 × 10−18 Nm for RNA polymerase48). The rotational trap stiffnesses we have measured are 0–1.2 × 10−18 Nm rad−1 and can be controlled by varying particle size and electric field magnitude and frequency. These stiffness values are within the range of those in magnetic tweezer experiments with superparamagnetic micro-beads tethered to a surface.50 The torque resolution for sensing depends on the uncertainty of the angle detection via rotational tracking. We achieve ∼ 0.2 degrees (∼0.004 rad) in our experiments (see Appendix B), meaning that our reduced rotational trap stiffnesses would allow sufficient resolution for biological torque sensing. Most current single-molecule force and torque spectroscopy techniques suffer from the disadvantage of coupled torque and force sensing.48 The use of our HOPG micro-particles together with appropriately applied magnetic and electric fields to independently control rotational trapping and translational confinement, could result in the future in extremely useful, decoupled force and torque sensing schemes.
Fig. 9 shows atomic force microscopy (AFM) images of lipid-coated HOPG micro-particles of different sizes. The AFM image in solution [Fig. 9(a)] shows very round particles, corresponding to the external lipid bilayers forming a vesicle-like structure. Force versus indentation curves [Fig. 9(c)] reveal 4–5 indentation steps, suggesting that the particles are coated with several lipid bilayers.
000 repetitions.
Particle-dimension estimates are obtained for each micro-flake from the lengths of the minor and major axes of the fitted ellipses. For the 10 different individual lipid-coated HOPG micro-particles we have used in our measurements, the average dimensions are ∼2 μm × 4 μm × 7 μm (ellipsoid axis lengths with standard deviations ±0.5 μm).
Additionally, our amplified input voltage signal presents some variation with frequency. We can measure the input alternating voltage amplitude, Vin, into the electrode wires and the output voltage, Vout, transmitted through them [see Fig. 10(a)], as a function of frequency, and define Vr = Vout/Vin. By considering voltage signal reflection and transmission through two subsequent boundaries with impedances Z0 → Zw and Zw → Z0 at either side [see Fig. 10(a)], we can calculate the voltage amplitude at the sample as Vw = Vin [2Zw/(Z0 + Zw)]. The factor [2Zw/(Z0 + Zw)] corresponds to the voltage transmission coefficient through the input Z0 → Zw boundary. Zw can be calculated as
using the measured value of Vr at each frequency. We find no appreciable difference between voltage measurements in solution and in dry samples, within our measurement uncertainties, owing to the fact that our thin sample wires are insulated with an enamel coating. Fig. 10(b) shows the measured Vin and Vout amplitudes and calculated Vw as a function of frequency, normalised to the value of the input voltage amplitude at zero frequency, Vin,0 (typically ∼2.3 V). Five measurements are taken at each frequency, re-soldering the thin electrode wires each time, to check reproducibility upon re-connection. Mean values are shown as data points, with standard errors as error bars. Since, as given by eqn (7) with E0 = Vw/d and as shown by the data in Fig. 11, the electric torque is proportional to the square of the electric field modulus and, therefore, proportional to Vw2, a correction factor (Vw/Vin,0)−2 is used in our data analysis to multiply and scale our measured values of electric torque as a function of frequency, in order to correct for the above-mentioned effects.
![]() | (14) |
![]() | (15) |
Footnote |
| † Electronic supplementary information (ESI) available: Videos of HOPG micro-flakes in solution in the presence of a vertical orienting magnetic field, rotating to align with a horizontal AC electric field. See DOI: 10.1039/c6ra07657b |
| This journal is © The Royal Society of Chemistry 2016 |