Open Access Article
This Open Access Article is licensed under a Creative Commons Attribution-Non Commercial 3.0 Unported Licence

Poly(ether ether ketone) (PEEK)-based graft-type polymer electrolyte membranes having high crystallinity for high conducting and mechanical properties under various humidified conditions

Takashi Hamada , Shin Hasegawa , Hideyuki Fukasawa , Shin-ichi Sawada , Hiroshi Koshikawa , Atsumi Miyashita and Yasunari Maekawa *
Functional Polymer Group, Quantum Beam Science Directorate, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292, Japan. E-mail: maekawa.yasunari@jaea.go.jp; Fax: +81 27 346 9687; Tel: +81 27 346 9410

Received 21st July 2015 , Accepted 8th September 2015

First published on 8th September 2015


Abstract

Poly(ether ether ketone)-based graft-type polymer electrolyte membranes (PEEK-PEMs) with wide ion exchange capacity (IEC) ranges were prepared by radiation-induced graft polymerization for investigating the relative humidity (RH) dependence of their electrochemical and mechanical properties at 80 °C for fuel cell applications. The proton conductivity ranges of 1.73–3.08 mmol g−1 IECs at 30% and 95% RH were 0.001–0.009 and 0.108–0.431 S cm−1, respectively. Unlike aromatic hydrocarbon-type PEMs, PEEK-PEMs' conductivity exhibited less dependence on RH. PEEK-PEMs with IECs > 3.08 mmol g−1 exhibited a similar conductivity (0.009 S cm−1) under 30% RH and showed 1.4 times higher tensile strength (14 MPa) under 100% RH at 80 °C in comparison to Nafion 212. The MEA fabricated by the PEEK-PEM with IEC = 2.45 mmol g−1 showed the maximum power densities (Emax) of 860 and 826 mW cm−2 at 2140 and 2180 mA cm−2 under 100% and 30% RH, respectively. In particular, PEEK-PEM showed low RH dependence for Emax, which was 2.5 times higher than that of Nafion 212 at 30% RH. The X-ray scattering analyses revealed that the crystallinity of approximately 28–32% was maintained and propagated during the graft polymerization of graft-type PEEK-PEMs. The abovementioned unique structures were the origins of higher conductivity and tensile strengths compared with conventional PEMs.


Introduction

Polymer electrolyte membrane fuel cells (PEMFCs) can produce energy from hydrogen and oxygen without air pollution and have therefore attracted attention for use in next-generation energy applications such as fuel cell vehicles and stationary cogeneration systems to replace fossil fuel resources.1 The polymer electrolyte membrane (PEM) is a particularly important part of PEMFCs because it separates the two electrodes and transports protons from the anode to the cathode.2,3 Currently, sulfonated perfluoropolymers such as Nafion™ have been used mostly as PEMs. However, these materials cause several issues such as high fuel crossover and a limited operating temperature range of up to 80 °C (low glass transition temperature).4–6 Numerous sulfonated aromatic hydrocarbon-type polymers such as poly(ether ether ketone),7,8 poly(phenylene sulfone),9–12 poly(arylene ether ketone),13 polyimides,14–16 poly(phenylene),17,18 and polybenzimidazole19,20 have been designed and synthesized as alternatives to perfluorinated PEMs because of their rigid aromatic backbone, which gives them higher thermal stability and mechanical strength.

Recently, for PEMs, high proton conductivity and mechanical properties under low and high relative humidity (RH) conditions have become a main concern, respectively, because these properties control power generation efficiency and durability under the extreme operating conditions of fuel cell systems. One solution to this problem is to increase ion exchange capacity (IEC), which is related to PEM conductivity.19,21,22 However, PEMs with higher IEC exhibit severe damage in a hydrated state under flooding conditions. Unfortunately, PEMs based on hydrocarbon polymers show much lower proton conductivity at low RH compared with the perfluorinated PEMs, although their proton conductivities are almost the same in high-RH ranges. One promising strategy for improving conductivity even with fewer water molecules in PEMs is the use of multiblock-type aromatic hydrocarbon polymers that comprise hydrophilic and hydrophobic units, e.g., block-type poly(arylene ether sulfone)s and poly(phenylene) block copolymers.23–27 However, multiblock-type aromatic hydrocarbon polymers have critical issues that include insufficient durability and the fact that their conductivity significantly depends on RH. Another approach to overcome this problem is using aromatic hydrocarbon-based PEMs that have locally condensed sulfonic acid groups or perfluoroalkyl sulfonic acid groups, the so-called, superacid.28–30 Although these PEM materials show a pronounced hydrophilic/hydrophobic phase-separated morphology with well-interconnected proton transport pathways leading to high conductivity at low RH, the mechanical properties of PEMs were evaluated only at room temperature under relatively dry conditions but not under hydrated conditions at higher temperatures.

Graft-type PEMs, which are prepared by radiation-induced graft polymerization of monomers and the subsequent sulfonation reaction of the graft polymers, can overcome the abovementioned problems because the graft-type PEM comprises substrate films that have a mechanically tough crystalline phase and various functional grafted polymer phases directly bonded to the polymer main chain.31–44 Furthermore, the introduction of sulfonated graft side chains into the polymer main chain is an excellent approach to PEM preparation because the IEC values can be controlled by easily changing the degree of grafting. Recently, we studied the RH dependence of the electrochemical and mechanical properties of poly(styrene sulfonic acid) (PSSA)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membranes (ETFE-PEMs) over a wide IEC range.45,46 Unlike aromatic hydrocarbon-type PEMs, the proton conductivity of ETFE-PEMs has less RH dependence because hydrophilic grafted polymers provide clearer phase separation from the hydrophobic ETFE substrate, thereby maintaining conducting channels even under dry conditions. Therefore, ETFE-PEMs with IEC > 2.7 mmol g−1 exhibited higher conductivity (>0.009 S cm−1) at 30% RH and showed comparable tensile strength of approximately 10 MPa at 100% RH and 80 °C.45

To overcome the abovementioned trade-off relationship between conductivity and mechanical properties, we selected poly(ether ether ketone) (PEEK), which is one of the typical super engineering plastics that possess the highest mechanical and thermal properties, as the base substrate film. We succeeded in achieving radiation-induced graft polymerization of styrene and ETSS on low crystalline PEEK substrates via a three-step process, as shown in Scheme 1. The three steps are thermal graft polymerization of divinylbenzene (DVB) into the PEEK substrates and subsequent radiation-induced graft polymerization of ETSS, followed by hydrolysis of the ester group in the graft polymers. As a result, the prepared PSSA-grafted PEEK (PEEK-PEM) with an IEC of 1.36 mmol g−1 showed 1.3 times higher conductivity under the equilibrated hydration conditions and 3 times higher tensile strength under dry conditions at room temperature, compared with the corresponding values of Nafion 212.47 The well-balanced electrochemical and mechanical properties of PEEK-PEMs encouraged us to develop PEEK-PEMs with higher IEC ranges to improve proton conductivities under low RH conditions while retaining the mechanical properties to some extent under high RH conditions. In this study, we report the RH dependence of the electrochemical and mechanical properties of PEEK-PEMs in a wide IEC range in comparison with those of perfluorinated PEMs, as well as on fuel cell performance. Moreover, we carefully monitored changes in the crystallinity of the PEEK substrates during the preparation procedures such as DVB introduction, radiation-induced grafting, and hydrolysis using X-ray diffraction (XRD) to elucidate the origin of higher conductivity and mechanical strength.


image file: c5ta05567a-s1.tif
Scheme 1 Radiation induced-graft polymerization of ETSS onto PEEK substrates and subsequent hydrolysis of ethyl ester groups.

Experimental

Materials

PEEK films with a thickness of 16 μm and 11% crystallinity were purchased from Victrex plc, Japan and cut into a size of 10 × 9 cm. Ethyl 4-styrenesulfonate (ETSS) was provided by Tosoh Co., Japan and used as received. DVB (technical grade, 80%) was purchased from Sigma-Aldrich Co., Japan and used without purification. 1,4-Dioxane was purchased from Wako Pure Chemical Industries, Ltd and dried over molecular sieves before use. Other solvents were purchased from Wako Pure Chemical Industries, Ltd and used as received. Sodium chloride (NaCl), sodium hydroxide (NaOH), and hydrochloric acid of analytical grade were purchased from Wako Pure Chemical Industries, Ltd. Pure water was obtained from a Millipore Milli-Q UV system. Nafion 212 obtained from DuPont was pretreated by boiling for 1 h in a 3% H2O2 solution, washing in hot pure water for 1 h, boiling for 1 h in 1 M H2SO4, and final rinsing in hot water again for 1 h. Nafion perfluorinated ion-exchange resin, 20 wt% soln of lower aliphatic alcohols/H2O mixture was purchased from Sigma-Aldrich Co., Japan and used without purification. The Pt/C catalyst was purchased from Tanaka Kikinzoku kogyo Ltd, Japan.

Preparation of PEEK-PEMs

PEEK films were added to a dried Schlenk tube. After the air was removed and purged with argon, a solution of DVB/1,4-dioxane (25 vol%) was added to the Schlenk tube in an argon atmosphere and heated in a water bath at 50 °C for 24 h. The obtained films were washed with 1,4-dioxane and immersed in 100 mL of 1,4-dioxane at 50 °C for 12 h to remove residual monomers. The obtained films (PEEK-DVB) were dried in a vacuum at 40 °C for 24 h.

A PEEK-DVB film in a Schlenk tube was irradiated with 60Co γ-rays at a dose rate of 10 kGy h−1 for 16 h under an argon atmosphere at room temperature. Then, a solution of 15 mL of ethyl 4-styrenesulfonate and 15 mL of 1,4-dioxane was degassed by argon bubbling and added to the Schlenk tube containing the PEEK-DVB film. The mixture was heated at 80 °C under an argon atmosphere for 6–24 h. Grafted PEEK films were taken out, and washed with acetone. To remove residual ethyl 4-styrenesulfonate and the free polymer on the film surfaces, grafted PEEK films were soaked in a large amount of acetone overnight. The obtained films were dried in a vacuum at 40 °C for 24 h.

The hydrolysis of ethyl ester was carried out in distilled water at 95 °C for 24 h to obtain PEEK-PEM.

Electrolyte properties of PEEK-PEMs

Grafting degrees (GDs) were estimated from the mass weighting as follows:
 
image file: c5ta05567a-t1.tif(1)

In this equation, W0 and Wg are denoted as the weight of films before and after graft polymerization, respectively.

The degree of hydrolysis and ion exchange capacity was determined by a titration method. The dried films were immersed in 25 mL of an aqueous 3 M NaCl solution overnight (or 24 h) to reach equilibrium. Then, the remaining solution was titrated with 0.01 M NaOH solution by using an automatic titrator. The IEC was calculated according to the following equation (eqn (2)):

 
image file: c5ta05567a-t2.tif(2)
where VNaOH is the volume of 0.01 M NaOH solution and Wd is the weight of dried films. The weight of the membranes was quickly measured after the membranes were taken out.

The degree of hydrolysis, namely, the hydrolysis degree (HD) is calculated by the following equation (eqn (3)):

 
image file: c5ta05567a-t3.tif(3)

Water uptake (WU) was defined by the following equation (eqn (4)):

 
image file: c5ta05567a-t4.tif(4)

The membranes were fully hydrated in water at room temperature, and lightly wiped with Kimwipes to remove excess water on the surface. To measure the RH dependence of the WU and hydration number, the membranes were placed in a humidity controlled chamber under different RH conditions at 80 °C for 2 h. After the membrane was taken out, the membrane was put into a plastic bag and sealed to prevent vapor absorption or desorption and quickly weighed on a microbalance. The water uptake and hydration number were calculated using the following equations (eqn (5) and (6)), respectively.

 
image file: c5ta05567a-t5.tif(5)

The membrane was placed between two platinum electrodes, and the proton conductivity in the plane direction of the membrane was measured by impedance spectroscopy at room temperature. The membrane was placed in an ESPEC PR-2K temperature/humidity-controlled chamber under the RH ranging from 30 to 95% at 80 °C. The proton conductivity was calculated from the obtained resistance (R) according to the following equation (eqn (6)):

 
image file: c5ta05567a-t6.tif(6)
where d (cm) is the thickness of the membrane and S (cm2) is the contact area of two electrodes.

Characterization of PEEK-DVB, grafted PEEK, and PEEK-PEM

Thermogravimetric analysis (TGA) was performed on a TGA Thermal Plus/TG-DTA8120 (Rigaku, Japan) at a heating rate of 10 °C min−1 and a nitrogen flow rate of 50 mL min−1. Differential scanning calorimetry (DSC) was performed using a Thermo Plus2/DSC8230 with the specimen of 4–5 mg at a heating rate of 10 °C min−1 to the temperature of 900 °C. Tensile tests were performed using an STA-1150 (A&D Co., Ltd, Japan) and an Instron-4302 universal testing instrument. The mechanical properties of PEEK-PEMs were measured at 100% RH and 80 °C at a constant crosshead speed of 10 mm min−1. The tensile strength of PEEK-PEMs was calculated as an average of five samples. The XRD experiment was undertaken with a Rigaku SmartLab using CuK radiation (λ = 1.54 Å) at 40 kV and 45 mA in the 2θ range from 5 to 40°. The degree of crystallinity (DOC) of PEEK-PEMs was calculated using the following equation (eqn (7)):
 
image file: c5ta05567a-t7.tif(7)
where Icr and Iam are the integrated values of the PEEK crystalline peak and the amorphous peaks, respectively.

The degree of crystallinity of the PEEK phase in PEEK-PEMs (DOC′) was estimated by taking into account the introduction of poly(styrene sulfonic acid) and using the following equation (eqn (8)):

 
image file: c5ta05567a-t8.tif(8)

The membrane electrode assembly (MEA) fabrication and fuel cell test

200 mg of Pt/C and 0.2 mL of 20 wt% Nafion perfluorinated ion-exchange resin were dispersed in a mixture of 4.8 mL of water and 4.8 mL of methanol. The solution mixture was sonicated for 3 h and coated onto the gas diffusion media (3 cm × 3 cm) of carbon and Teflon by spraying to prepare the electrode. The obtained electrode was dried at 95 °C for 10 min. The Pt loading was estimated to be 0.4 mg cm−2 from the weight of the gas diffusion media before and after spraying the solution mixture. The PEEK-PEM (5.0 cm × 5.0 cm) was sandwiched by the electrode, and hot-pressed at 170 °C under 1 MPa for 1 min and cooled to room temperature to obtain an MEA with an active area of 5 cm2 and Pt loading of 0.4 mg cm−2. The MEA of the hybrid PEM was assembled into a cell holder. The fuel cell testing was performed at a cell temperature of 80 °C under different RH of 100% and 30% RH using a single fuel cell device (Micro equipment Inc. me-300FC). During the cell test, hydrogen and oxygen were supplied at a flow rate of 50 mL min−1 each to the anode and cathode, respectively. The IV curves were measured in the range of 0.9–0.3 with a step repeatedly, typically a few times, until the fuel cell performance reached the steady state.

Results and discussion

Preparation and characterization of PEEK-PEMs

PEEK-PEMs were prepared via a three-step process, as previously reported (Scheme 1). DVB was introduced into the PEEK substrates by thermal polymerization at 50 °C for 24 h in 1,4-dioxane. By TGA measurements, the amount of DVB incorporated into the PEEK substrates was estimated to be 2–3 wt%.34,35 Next, we used the DVB-containing PEEK films as base polymer films for further radiation-induced graft-polymerization. The PEEK film was irradiated with a dose of 160 kGy at room temperature. The graft polymerization of ETSS proceeded smoothly in a 50 vol% 1,4-dioxane solution at 80 °C. We controlled the GD range from 70% to 207% by employing grafting periods of 6–24 h, as listed in Table 1. This is because PEMs which possess both sufficient conductivity and mechanical properties under a wide RH range should have IECs ranging from 1.5 to 3.5 judging from the RH dependence of fluoropolymer-based ETFE-PEMs, which we previously reported.45 The grafted-PEEK films with GDs of 70–207% were hydrolyzed in water at 95 °C for 24 h to convert ethyl sulfonate into sulfonic acid in a yield range of 86–98%. Consequently, the prepared PEEK-PEMs showed IECs ranging from 1.73 to 3.08 mmol g−1. Since most of the graft-type PEMs prepared by radiation-induced graft-polymerization including PEEK-PEMs are insoluble in neither organic nor aqueous solutions, the chemical structure of the PEEK-PEMs had been characterized using ATR-IR and TGA-DSC analysis. The thermal stability of the PEEK-PEMs had also been investigated using TGA-DSC in the previous papers.34,36,47,48
Table 1 Radiation induced-graft polymerization and hydrolysis results and properties of PEEK-PEMs
GD of ETSS (%) HD (%) IEC (mmol g−1) (Cal.) IEC (mmol g−1) (Exp.) WU (%) σ (S cm−1)
70 89 1.78 1.73 25 0.068
85 98 2.09 2.22 38 0.103
124 97 2.65 2.49 58 0.134
134 84 2.75 2.36 44 0.119
142 89 2.84 2.64 80 0.154
171 86 3.10 2.74 88 0.170
207 90 3.36 3.08 120 0.210
Nafion 212 0.80 39 0.087


PEEK-PEMs with an IEC of 2.22 mmol g−1 exhibited a proton conductivity of 0.103 S cm−1, which is higher than that of Nafion 212. In particular, for PEEK-PEMs with an IEC of 3.08 mmol g−1, the proton conductivity reached 0.210 S cm−1, which is 3 times higher than that of Nafion 212. As expected, the large quantity of poly(styrene sulfonic acid) as the graft polymer led to a significant enhancement in conductivity. Furthermore, the water uptake, which ranged from 25% to 120%, increased with increasing IEC. In a previous report, we reported that ETFE-PEMs with IECs ranging from 0.52 to 3.3 mmol g−1 showed proton conductivities of 0.002–0.233 S cm−1 and water uptake of 2.7–168%.45 The proton conductivities of PEEK-PEMs were similar to those of ETFE-PEMs because of their similar IEC values. However, the water uptake of PEEK-PEMs was lower than that of ETFE-PEMs. PEEK-PEMs with an IEC of 2.22 mmol g−1 exhibited a WU of 38%, which was similar to that of Nafion 212 with an IEC of 0.8 mmol g−1 (39%). This unique property is important for PEMs because a high water uptake causes severe swelling of PEMs, which damages membranes during fuel cell operation. In particular, despite the presence of large amounts of hydrophilic sulfo groups (higher IECs), the PEEK-based PEMs suppressed swelling of the hydrophilic graft chain with water.

Proton conductivity of PEEK-PEMs under various RH

As mentioned in the Introduction, the RH dependence of proton conductivity and mechanical strength are currently the main concerns because these properties are directly related to the power generation efficiency and durability of fuel cells. Thus, we examined at 80 °C the RH (30–95% RH) dependence of the proton conductivity of the PEEK-PEMs with IECs of 1.73–3.08 mmol g−1 (GD = 70–207%) together with that of Nafion 212 as a reference, as shown in Fig. 1.
image file: c5ta05567a-f1.tif
Fig. 1 Relative humidity dependence of proton conductivity at 80 °C for PEEK-PEMs with IECs of 1.73–3.08 mmol g−1 and Nafion 212.

The PEEK-PEMs with various IECs covered a wide range of conductance with more than three orders of magnitude, ranging from 0.001 to 0.009 S cm−1 and from 0.108 to 0.431 S cm−1 at 30% and 95% RH, respectively. At RHs higher than 80%, the proton conductivity of PEEK-PEMs with IECs higher than 2.22 mmol g−1 was found to be comparable with or higher than that of Nafion 212. At 30% RH, the proton conductivity of the PEEK-PEM with an IEC of 3.08 mmol g−1 increased with increasing IEC and reached a value similar to that of Nafion 212.

The slopes in the plots of log[thin space (1/6-em)]σ as a function of RH were employed as feasible parameters for evaluating the RH dependence of conductance for PEMs, which were designed for achieving high conductivity under lower RH conditions. The slope of PEEK-PEMs became slightly steeper when IEC increased from 1.73 to 3.08 mmol g−1. The PEEK-PEM with the highest IEC (3.08 mmol g−1) showed a slope steeper than that of Nafion 212. However, the proton conductivity of PEEK-PEMs was less dependent on RH compared with the aromatic hydrocarbon-type PEMs such as aliphatic/aromatic polyimide and ethynyl-terminated sulfonated-fluorinated poly(arylene ether)s, the conductance of which changed by 4–5 orders of magnitude when the RH changed from 100% to 30%. The RH dependence of proton conductivity of the PEEK-PEMs with high IECs is similar to that of fluorinated polymer-based graft-type PEMs (ETFE-PEMs), which we previously reported. Two different types of graft-type PEMs showed much better RH dependence than conventional aromatic hydrocarbon PEMs. Hence, adequate phase separation of the ion channels composed of graft polymer chains should be ensured from the hydrophobic polymer substrates (ETFE and PEEK) in comparison with the less phase-separated hydrocarbon-type PEMs such as PEEK, as we have proved by SAXS and SANS measurements.47

The humidity dependence of water uptake and hydration number λ, which is defined as the number of water molecules per sulfo group in PEMs, was plotted as a function of RH for PEEK-PEMs with IECs ranging from 1.73–3.08 mmol g−1 at 80 °C, together with Nafion 212 as a reference, as shown in Fig. 2. At higher RH (95%), the PEEK-PEMs with IECs of 1.73, 2.36, and 3.08 mmol g−1 showed higher water uptakes (50%, 62%, and 102%) than Nafion 212. In high RH regions, the high water uptakes of PEEK-PEMs were attributed to high IECs compared with Nafion 212, which has an IEC of 0.8 mmol g−1. As previously reported for many hydrocarbon-type and graft-type PEMs,7–20 the water uptake of PEEK-PEMs decreased with decreasing RH and at 30% RH. The PEEK-PEMs with IECs of 1.73, 2.36, and 3.08 mmol g−1 showed water uptakes of 9.7%, 16%, and 17%, which corresponded to λ values of 3.1, 3.7, and 3.1, respectively. The λ values were relatively close to that of Nafion 212 (λ = 2.95). As many groups have already reported, PEM conductivity under low RH conditions was explained in terms of water uptake and the hydration number, λ. Contrary to conventional aromatic hydrocarbon-type PEMs with high IEC levels, which showed lower λ than Nafion under low RH conditions, the λ of the PEEK-PEMs was similar to that of Nafion. Accordingly, the λ of PEEK-PEMs with an IEC of 3.08 mmol g−1 was equal to that of Nafion even under 30% RH. Notably, not only high IEC levels but also high retention of water molecules affords high proton conductivity even under 30% RH and suppresses the humidity dependence of graft-type PEMs compared with other aromatic hydrocarbon-type PEMs. Recently, we clarified that ETFE-PEMs with IECs greater than 2.7 mmol g−1 possess ion channels composed of poly(styrene sulfonic acid) grafts located outside the crystallite network domains by small-angle X-ray scattering experiments. These ion channels are well interconnected around the crystallites, which endow ETFE-PEMs with high conductivity under low RH conditions. Similarly, PEEK-PEMs with high IECs should have similar well-interconnected ion channels, composed of poly(styrene sulfonic acid) of PEEK-PEMs.


image file: c5ta05567a-f2.tif
Fig. 2 Relative humidity dependence of water uptake (a) and hydration number (b) for PEEK-PEMs with IECs of 1.73, 2.36, and 3.08 mmol g−1 and Nafion 212 as a reference at 80 °C.

Mechanical properties of PEEK-PEMs under humidified conditions

The mechanical properties of PEMs under humid conditions such as flooding govern their durability under severe operating conditions of fuel cell systems because PEMs absorb large amounts of water, which induces large stresses in the membranes resulting in their degradation. Thus, we examined the TS and elongation at break of the PEEK-PEMs with IECs of 1.73–3.08 mmol g−1 at 80 °C under 100% RH. This was compared with Nafion 212 as a reference, as shown in Fig. 3. The PEEK-PEM with an IEC of 1.73 mmol g−1 showed higher TS (35 MPa) than Nafion 212 (10 MPa). In the IEC range of 1.73–3.08 mmol g−1, the TS of PEEK-PEMs gradually decreased with an increase in IEC, but it still remained 1.4 times higher than that of Nafion 212 (14 MPa). It was reported that the lower TS of graft-type PEMs with higher IECs was mainly because of higher water uptake but not because of the introduction of PSSA graft polymers. However, the TS of PEEK-PEMs across the entire IEC range was much higher than that of Nafion 212, and the PEEK-PEM with an IEC of 2.22 mmol g−1 showed the same level of conductivity but 2.6 times higher TS (26 MPa) compared with Nafion 212.
image file: c5ta05567a-f3.tif
Fig. 3 Tensile strength (a) and elongation at break (b) of PEEK-PEMs with IECs of 1.73–3.08 mmol g−1 and that of Nafion 212 (dotted lines as a reference) under 100% RH at 80 °C.

Several groups have measured the TS of aromatic hydrocarbon-type PEMs under humidified conditions, such as sulfonated poly(aryl ether nitrile) (18–41 MPa, hydrated state, r.t.),49 poly(aryl ether ketone) containing tetra-sulfonated side chains (25–46 Mpa, 50% RH, r.t.),50 sulfonated poly(sulfide sulfone imide) copolymers (13–29 MPa, hydrated state, r.t.),51 poly(arylene ether ether nitrile) (18–22 MPa, 50% RH, 20 °C),52 and poly(phenylene ether) (34–54 MPa, 50% RH, 20 °C).53 These values were measured under mild conditions such as low temperature or low RH even though the mechanical properties of membranes were influenced by water uptake; thus, TS decreased with increasing RH in most of the aromatic hydrocarbon-type PEMs. In our previous study, the ETFE-PEMs with an IEC of 2.9 mmol g−1 showed a TS of 32 and 8.0 MPa under dry and fully humid conditions (0 and 100% RH) at 80 °C, respectively. In particular, PEEK-PEMs with various IECs have higher TS compared with Nafion 212, graft-type ETFE-PEMs, and other aromatic hydrocarbon-type PEMs under severe conditions (80 °C, 100% RH). This is because the hydrophobic PEEK matrix, which prevents severe swelling, possesses high TS (65 MPa for pristine PEEK films) and maintains high TS because of less damage to PEEK substrates during the preparation procedures, thus resulting in better mechanical properties of even PEEK-PEMs with high IECs and containing large volumes of poly(styrene sulfonic acid) grafts.

Morphological changes of PEEK substrates by preparation procedures

We measured the XRD of the original PEEK, PEEK-DVB, grafted-PEEK with a GD of 70%, and a PEEK-PEM with an IEC of 1.73 mmol g−1 (sulfonic acid form of the grafted-PEEK). As shown in Fig. 4(a), the original PEEK with a crystallinity of 11% showed a broad peak centered at 1.3 Å−1, originating from an amorphous halo. New peaks at 1.45 Å−1 with two recognizable shoulder-like peaks at 1.48 Å−1 and 1.62 Å−1, assigned to the (110), (111), and (200) planes, appeared upon thermal polymerization of DVB, as shown in Fig. 4(b). In the grafted-PEEK with a GD of 70% and the corresponding PEEK-PEM with an IEC of 1.73 mmol g−1, new amorphous halos were observed with a peak-center at 1.15 Å−1, attributed to amorphous poly(ETSS) and PSSA graft chains, respectively (Fig. 4(c) and (d)).
image file: c5ta05567a-f4.tif
Fig. 4 XRD spectra of (a) PEEK, (b) PEEK-DVB, (c) grafted-PEEK (GD = 70%), and (d) PEEK-PEM with an IEC of 1.73 mmol g−1 (sulfonic acid form of the grafted-PEEK). The separated peaks attributed to the amorphous halo and (110), (111), and (200) planes of PEEK (a and b) with amorphous poly(ETSS) and PSSA graft peaks (c and d) are shown as dotted lines.

The XRD spectrum of the PEEK-DVB, grafted-PEEK with a GD of 70%, and the corresponding PEEK-PEM with an IEC of 1.73 mmol g−1 were well peak-separated into four peaks attributed to the amorphous halo and the (110), (111), and (200) planes by a curve-fitting method, as shown in Fig. 4. The morphological changes induced by PEM preparation procedures (thermal polymerization of DVB, radiation-induced graft-polymerization of ETSS, and hydrolysis of ethyl ester) were evaluated in terms of the degree of crystallinity (DOC), which was calculated using the separated peaks and eqn (7). As can be seen by comparing Fig. 4(a) and (b), thermal treatment for the polymerization of DVB into original PEEK films increased the DOC from 11 to 28%. The DOC of 28% is in good agreement with that obtained from the melting enthalpy of PEEK crystals in the DSC profile of PEEK-DVB. Because it has been reported that solvent-induced recrystallization of the amorphous PEEK solid proceeded at approximately 50 °C because of the lowering of the glass transition temperature (Tg), the amorphous phase in the PEEK substrate recrystallized during thermal graft polymerization of DVB.54–56 The DOCs of the grafted-PEEK and PEEK-PEM (22% and 18%) were lower than that of PEEK-DVB because of the introduction of amorphous poly(ETSS) and PSSA grafts. However, considering only a PEEK substrate area (in particular, subtracting the graft-polymer phases from the PEMs), the DOC′s of these films (namely, subtracting the graft-polymer phases from the PEMs) were 36% and 31%. Accordingly, the crystallinities of the PEEK substrates increased to some extent during radiation-induced grafting in ETSS/dioxane solution at 80 °C and hydrolysis in water at 95 °C.

The DOC and DOC′ of PEEK-PEMs were plotted as a function of the DOG in Fig. 5. The DOC based on whole membranes in PEEK-PEMs decreased linearly from 18% to 11% when the IECs increased from 1.73 to 3.08 mmol g−1, which correspond to GDs of 70% and 207%, because of the increase in the amounts of incorporated amorphous graft-polymers. However, the DOC′ determined on the basis of the PEEK substrate area in PEEK-PEMs increased slightly to approximately 31%. We reported that the crystallinity of ETFE-PEMs decreased during severe sulfonation in the dichloroethene solution of chlorosulfonic acid (strong acid) at 60 °C, and damage was induced in the lamellar crystals.45 However, the PEEK-PEM preparation process does not involve sulfonation, but only mild hydrolysis in water for preparing PEEK-PEMs. It should be noted that the amorphous phase in PEEK substrates was recrystallized during graft polymerization; thus, the crystallinity of the PEEK substrate in PEEK-PEMs was maintained because of the mild hydrolysis conditions compared with the severe sulfonation conditions that ETFE-PEMs were subjected to, resulting in the enhancement of tensile strength.


image file: c5ta05567a-f5.tif
Fig. 5 DOC (○) and DOC′ (●) of PEEK-DVB and PEEK-PEMs with IECs of 1.73–3.08 mmol g−1, which are estimated on the basis of PEEK-substrates and PEMs.

We have reported the RH dependence of the electrochemical and mechanical properties of ETFE-PEMs.46 In the report, SAXS experiments revealed that hydrophilic grafted polymers provide clearer phase separation from the hydrophobic ETFE substrate, thereby maintaining conducting channels even under lower RH conditions. Therefore, tentatively, we consider that the PEEK-PEMs with higher IECs should have similar ion-channels even at lower RH. Unfortunately, compared with the ETFE-PEMs, the aromatic hydrocarbon-based PEEK-PEMs have less information in the SAXS profiles. Thus, we are planning to investigate the morphology of PEEK-PEMs by the combination of SAXS and SANS with a contrast variation method under dry and wet conditions.

Oxidative stability of PEEK-PEMs

The oxidative stability of PEEK-PEMs with IECs = 1.73, 2.36, and 3.08 mmol g−1 was evaluated as the change in the weight of the membranes in Fenton's reagent (3% H2O2 aq., 2 ppm FeSO4) at 80 °C (Fig. S2). The PEEK-PEMs with high IECs showed low oxidative stability against Fenton's reagent. For example, the oxidative stabilities of poly(phenylene ether)s with sulfonic acid having alkyl side chains in Fenton's reagent (3% H2O2 aq., 2 ppm FeSO4) at 80 °C for 1 h were 81–94%.17 The PEEK-PEMs with higher IEC levels retained their weight in Fenton's reagent after 1 h, and their weights gradually decreased with increasing immersion time. Accordingly, the PEEK-PEMs showed superior oxidative stability than the conventional sulfonated aromatic hydrocarbon-type PEMs because the grafted poly(styrene sulfonic acid)s are well surrounded by PEEK chains, which suppress hydroxyl radical attacks.

Fuel cell performance

Membrane-electrode assemblies (MEAs) were fabricated using the PEEK-PEM with an IEC of 2.45 mmol g−1 (film thickness of 26 μm) and Pt (0.4 mg cm−2)-loaded gas diffusion layers as the anode and cathode catalyst layers, respectively. The fuel cell test of the MEAs was performed at 80 °C under dry and humid conditions (30% and 100% RH); the current–voltage (IV) polarization curves of the fuel cells are plotted in Fig. 6. Under the completely humidified condition, the PEEK-PEM-based MEA showed a maximum power density (Emax) of 860 mW cm−2 at 2240 mA cm−2. The Emax value is somewhat higher than that of other aromatic hydrocarbon-type PEMs and is comparable with that of Nafion 212 (932 mW cm−2), prepared by the same method, under the same operating conditions. This can be explained by the similar conductivity levels of the PEEK-PEM with an IEC of 2.45 mmol g−1 and Nafion 212 at 80 °C under 95% RH (0.223–0.261 and 0.155 S cm−2 in Fig. 6(a)).
image file: c5ta05567a-f6.tif
Fig. 6 Fuel cell performance of MEAs fabricated with a PEEK-PEM with an IEC of 2.45 mmol g−1 and Nafion 212: (a) 100% RH at 80 °C and (b) 30% RH at 80 °C.

At 30% RH, the Emax of the PEEK-PEM-based MEA was 826 mW cm−2 at 2180 mA cm−2, which is the 96% level compared with 100% RH, whereas that of the Nafion 212-based MEA markedly decreased to the 36% level (333 mW cm−2 at 771 mA cm−2), as generally seen in other aromatic hydrocarbon-type PEM-based MEAs. Apparently, the Emax of the PEEK-PEM-based MEA was 2.5 times higher than that of the Nafion 212-based MEA under 30% RH and 80 °C. As mentioned before, the conductivity of PEEK-PEMs exhibited less RH dependence; thus, at 30% RH, the PEEK-PEM-based MEA with an IEC of 2.45 mmol g−1 showed less RH dependence, thus affording higher maximum power densities compared with aromatic hydrocarbon-type PEMs. Contrary to the comparison with other aromatic hydrocarbon-type PEMs, it is difficult to explain the different power densities of PEEK-PEM- and Nafion 212-based MEAs because of their similar conductivities under 30% RH. One possible reason for the above difference should be the different diffusion rates of the water molecules being produced at the cathode, that is, Nafion 212 is well known as a membrane with a remarkably high diffusion coefficient of water, whereas in general, the coefficient is considerably lower in the case of hydrocarbon-type PEMs. Furthermore, as shown in Fig. 2(a), the water uptake of PEEK-PEMs having IECs of around 2.45 mmol g−1 was over 10% at low RH (30% and 80 °C), whereas the water uptake of Nafion 212 under 30% RH and 80 °C was approximately 4%. In other words, the PEEK-PEM-based MEAs contain larger amounts of water molecules because of higher water uptake and poorer diffusion properties than the Nafion 212-based MEAs.

Conclusions

PEEK-PEMs with IECs in the range of 1.73–3.08 mmol g−1 showed higher conductivities of 0.001–0.009 S cm−1 even under low RH conditions (30% RH). This is because the proton conductivities of PEEK-PEMs are less dependent on RH compared with other aromatic hydrocarbon-type PEMs. Therefore, the PEEK-PEMs with an IEC of 3.08 mmol g−1 exhibited a similar conductivity to that of Nafion 212 (0.009 S cm−1) even at 30% RH probably because of its 17% water uptake, which is higher than that of Nafion 212 (WU 4.3%).

Under humid conditions, which test flooding in fuel cells, the PEEK-PEM has 1.4 times higher tensile strength (14 MPa) than Nafion 212. This is because the hydrophobic PEEK matrix prevents severe swelling, which originates from the high tensile strength of pristine PEEK films, thus helping maintain high TS because of less damage to the PEEK substrates.

The MEA fabricated using the PEEK-PEM with an IEC of 2.45 mmol g−1 showed Emax values of 860 and 826 mW cm−2 under 100% and 30% RH, respectively. This implies that the Emax of the PEEK-PEM showed low RH dependence, resulting in 2.5 times higher Emax than that of Nafion 212 at 30% RH.

X-ray scattering analyses revealed that the crystallinity of approximately 28–32% was maintained and propagated during graft polymerization of the graft-type PEEK-PEMs. The abovementioned unique structures were the origins of higher conductivity and tensile strengths, respectively, compared with conventional PEMs. Accordingly, PEEK-based graft-type PEMs should have great potential as alternative PEMs for Nafion.

Acknowledgements

The authors would like to thank Enago for the English language review.

References

  1. B. C. H. Steele and A. Heinzel, Nature, 2001, 414(15), 345–352 CrossRef CAS PubMed.
  2. M. S. Whittingham, R. F. Savinell and T. Zawodzinski, Chem. Rev., 2004, 104, 4243–4244 CrossRef CAS.
  3. M. Winter and R. J. Brodd, Chem. Rev., 2004, 4245–4269 CrossRef CAS.
  4. R. Borup, J. Meyers, B. Pivovar, Y. S. Kim, R. Mukundan, N. Garland, D. Myers, M. Wilson, F. Garzon, D. Wood, P. Zelenay, K. More, K. Stroh, T. Zawodzinski, J. Boncella, J. E. McGrath, M. Inaba, K. Miyatake, M. Hori, K. Ota, Z. Ogumi, S. Miyata, A. Nishikata, Z. Siroma, Y. Uchimoto, K. Yasuda, K. Kimijima and N. Iwashita, Chem. Rev., 2007, 107, 3904–3951 CrossRef CAS PubMed.
  5. Q. Li, R. He, J. O. Jensen and N. J. Bjerrum, Chem. Mater., 2003, 15, 4896–4915 CrossRef CAS.
  6. B. Smitha, S. Sridhar and A. A. Khan, J. Membr. Sci., 2005, 259, 10–26 CrossRef CAS PubMed.
  7. S. Zhong, C. Liu and H. Na, J. Membr. Sci., 2009, 326, 400–407 CrossRef CAS PubMed.
  8. X. Wu, G. He, X. Li, F. Nie, X. Yan and L. Yu, J. Power Sources, 2014, 246, 482–490 CrossRef CAS PubMed.
  9. E. A. Weiber, S. Takamuku and P. Jannasch, Macromolecules, 2013, 46, 3476–3485 CrossRef CAS.
  10. M. Schuster, C. C. de Araujo, V. Atanasov, H. T. Andersen, K.-D. Kreuer and J. Maier, Macromolecules, 2009, 42, 3129–3137 CrossRef CAS.
  11. C. Wang and S. J. Paddison, Soft Matter, 2014, 10, 819–830 RSC.
  12. S. Takamuku, A. Wohlfarth, A. Manhart, P. Räder and P. Jannasch, Polym. Chem., 2015, 6, 1267–1274 RSC.
  13. J. Pang, S. Feng, Y. Yu, H. Zhang and Z. Jiang, Polym. Chem., 2014, 5, 1477–1486 RSC.
  14. Y. Yin, Q. Du, Y. Qin, Y. Zhou and K. Okamoto, J. Membr. Sci., 2011, 367, 211–219 CrossRef CAS PubMed.
  15. K. Miyatake, H. Furuya, M. Tanaka and M. Watanabe, J. Power Sources, 2012, 204, 74–78 CrossRef CAS PubMed.
  16. K. H. Lee, S. Y. Lee, D. W. Shin, C. Wang, S.-H. Ahn, K.-J. Lee, M. D. Guiver and Y. M. Lee, Polymer, 2014, 55, 1317–1326 CrossRef CAS PubMed.
  17. X. Zhang, L. Sheng, T. Hayakawa, M. Ueda and T. Higashihara, J. Mater. Chem. A., 2013, 1, 11389–11396 CAS.
  18. X. Zhang, L. Sheng, T. Higashihara and M. Ueda, Polym. Chem., 2013, 4, 1235–1242 RSC.
  19. F. Ng, D. J. Jones, J. Rozière, B. Bauer, M. Schuster and M. Jeske, J. Membr. Sci., 2010, 362, 184–191 CrossRef CAS PubMed.
  20. S. Angioni, D. C. Villa, S. D. Barco, E. Quartarone, P. P. Righetti, C. Tomasi and P. Mustarelli, J. Mater. Chem. A., 2014, 2, 663–671 CAS.
  21. L. Sheng, T. Higashihara, M. Ueda and T. Hayakawa, J. Polym. Sci., Part A: Polym. Chem., 2014, 52, 21–29 CrossRef CAS PubMed.
  22. K. H. Lee, S. Y. Lee, D. W. Shin, C. Wang, S.-H. Ahn, K.-J. Lee, M. D. Guiver and Y. M. Lee, Polymer, 2014, 55, 1317–1326 CrossRef CAS PubMed.
  23. S. Chen, R. Hara, K. Chen, X. Zhang, N. Endo, M. Higa, K. Okamoto and L. Wang, J. Mater. Chem. A, 2013, 1, 8178–8189 CAS.
  24. J. R. Rowlett, Y. Chen, A. T. Shaver, O. Lane, C. Mittelsteadt, H. Xu, M. Zhang, R. B. Moore, S. Mecham and J. E. McGrath, Polymer, 2013, 54, 6305–6313 CrossRef CAS PubMed.
  25. T. Hoshi, B. Bae, M. Watanabe and K. Miyatake, Bull. Chem. Soc. Jpn., 2012, 85, 389–396 CrossRef CAS.
  26. K. Miyatake, D. Hirayama, B. Bae and M. Watanabe, Polym. Chem., 2012, 3, 2517–2522 RSC.
  27. N. Li, S. Y. Lee, Y.-L. Liu, Y. M. Lee and M. D. Guiver, Energy Environ. Sci., 2012, 5, 5346–5355 CAS.
  28. Y. Chang, G. F. Brunello, J. Fuller, M. L. Disabb-Miller, M. E. Hawley, Y. S. Kim, M. A. Hickner, S. S. Jang and C. Bae, Polym. Chem., 2013, 4, 272–281 RSC.
  29. T. Shimura, M. Watanabe and K. Miyatake, RSC Adv., 2012, 2, 5199–5204 RSC.
  30. K. Nakabayashi, T. Higashihara and M. Ueda, Macromolecules, 2011, 44, 1603–1609 CrossRef CAS.
  31. J. Park, K. Enomoto, T. Yamashita, Y. Takagi, K. Todaka and Y. Maekawa, J. Membr. Sci., 2013, 438, 1–7 CrossRef CAS PubMed.
  32. K. Enomoto, S. Takahashi, R. Rohani and Y. Maekawa, J. Membr. Sci., 2012, 415–416, 36–41 CrossRef CAS PubMed.
  33. K. Enomoto, S. Takahashi, T. Iwase, T. Yamashiata and Y. Maekawa, J. Mater. Chem., 2011, 21, 9343–9349 RSC.
  34. J. Chen, D. Li, H. Koshikawa, M. Zhai, M. Asano, H. Oku and Y. Maekawa, J. Membr. Sci., 2009, 344, 266–274 CrossRef CAS PubMed.
  35. J. Chen, M. Zhai, M. Asano, L. Huang and Y. Maekawa, J. Mater. Sci., 2009, 44, 3674–3681 CrossRef CAS.
  36. S. Hasegawa, K. Sato, T. Narita, Y. Suzuki, S. Takahashi, N. Morishita and Y. Maekawa, J. Membr. Sci., 2009, 345, 74–80 CrossRef CAS PubMed.
  37. S. Hasegawa, Y. Suzuki and Y. Maekawa, Radiat. Phys. Chem., 2008, 77, 617–621 CrossRef CAS PubMed.
  38. J. Chen, M. Asano, Y. Maekawa and M. Yoshida, J. Membr. Sci., 2006, 277, 249–257 CrossRef CAS PubMed.
  39. J. Chen, M. Asano, T. Yamaki and M. Yoshida, J. Power Sources, 2006, 158, 69–77 CrossRef CAS PubMed.
  40. K. Sato, S. Ikeda, M. Iida, A. Oshima, Y. Tabata and M. Washio, Nucl. Instrum. Methods Phys. Res., Sect. B, 2003, 208, 424–428 CrossRef CAS.
  41. T. Yamaki, M. Asano, Y. Maekawa, Y. Morita, T. Suwa, J. Chen, N. Tsubokawa, K. Kobayashi, H. Kubota and M. Yoshida, Radiat. Phys. Chem., 2003, 67, 403–407 CrossRef CAS.
  42. L. Gubler, Adv. Energy Mater., 2014, 4, 1300827 Search PubMed.
  43. K. Jetsrisuparb, S. Balog, C. Bas, L. Perrin, A. Wokaun and L. Gubler, Eur. Polym. J., 2014, 53, 75–89 CrossRef CAS PubMed.
  44. S. A. Gürsel, L. Gubler, B. Gupta and G. G. Scherer, Adv. Polym. Sci., 2008, 215, 157–217 Search PubMed.
  45. T. T. Duy, S. Sawada, S. Hasegawa, Y. Katsumura and Y. Maekawa, J. Membr. Sci., 2013, 447, 19–25 CrossRef PubMed.
  46. T. D. Tap, S. Sawada, S. Hasegawa, K. Yoshimura, Y. Oba, M. Ohnuma, Y. Katsumura and Y. Maekawa, Macromolecules, 2014, 47(7), 2373–2383 CrossRef CAS.
  47. S. Hasegawa, S. Takahashi, H. Iwase, S. Koizumi, N. Morishita, K. Sato, T. Narita, M. Ohnuma and Y. Maekawa, Polymer, 2011, 52, 98–106 CrossRef CAS PubMed.
  48. S. Hasegawa, S. Takahashi, H. Iwase, S. Koizumi, M. Ohnuma and Y. Maekawa, Polymer, 2013, 54, 2895–2900 CrossRef CAS PubMed.
  49. Z. Pu, L. Chen, Y. Long, L. Tong, X. Huang and X. Liu, J. Polym. Res., 2013, 20, 281 CrossRef.
  50. J. Pang, S. Feng, Y. Yu, H. Zhang and Z. Jiang, Polym. Chem., 2014, 5, 1477–1486 RSC.
  51. K. H. Lee, S. Y. Lee, D. W. Shin, C. Wang, S.-H. Ahn, K.-J. Lee, M. D. Guiver and Y. M. Lee, Polymer, 2014, 55, 1317–1326 CrossRef CAS PubMed.
  52. L. Sheng, T. Higashihara, M. Ueda and T. Hayakawa, J. Polym. Sci., Part A: Polym. Chem., 2014, 52, 21–29 CrossRef CAS PubMed.
  53. X. Zhang, L. Sheng, T. Hayakawa, M. Ueda and T. Higashihara, J. Mater. Chem. A, 2013, 1, 11389–11396 CAS.
  54. E. J. Stober, J. C. Seferis and J. D. Keenan, Polymer, 1984, 25, 1845–1852 CrossRef CAS.
  55. M. A. Grayson and C. J. Wolf, J. Polym. Sci., Part B: Polym. Phys., 1988, 26, 2145–2167 CrossRef CAS PubMed.
  56. C. J. Wolf, J. A. Bornmann, M. A. Grayson and D. P. Anderson, J. Polym. Sci., Part B: Polym. Phys., 1992, 30, 251–257 CrossRef CAS PubMed.

Footnote

Electronic supplementary information (ESI) available. See DOI: 10.1039/c5ta05567a

This journal is © The Royal Society of Chemistry 2015